  • 466-2338A • October 2009 © 2009 GE Security, Inc. g NX-6V2-Control Panel Installation Instructions Introduction This is the GE NX-6V2-Control Panel Installation Instructions. Installations should only be done by trained professionals. Use this document to install the system with default settings that comply with UL requirements. To install the keypad, other peripherals, and sensors, re

  • GE NetworX NX-6V2, NX-6V2-Control Panel Installation Instructions 2 Module list Table 3 shows the modules that are compatible with the NX- 6V2 system. Additional information and a catalog listing all system components is available from GE Customer Support. Note: The NX-6V2 control panel sends a trouble condition once each hour if it senses that no devices have been enrolled. This report shows expander trouble--device zero (0). Control panel programming Programming the control panel requires you to enter program mo

  • GE NetworX NX-6V2, 3 Loading factory defaults To load factory defaults, enter program mode, enter the device address and number and then enter 9, 1, 0, #. The keypad beeps three times indicating that loading is in progress. The process takes about six seconds. You cannot exit the location until loading is completed. Enrolling modules and keypads The NX-6V2 automatically finds and stores all keypads, zone expanders, wireless receivers, and other modules connected to the data terminal into the NX-6V2 memory. This allows the modules to be supervised by the control panel. To enroll the modules, do the following: 1. Enter program mode and program the

  • GE NetworX NX-6V2, NX-6V2-Control Panel Installation Instructions 4 Location 3 - Phone 1 dial attempts/backup control Location 3 has two segments of numerical data. Segment 1 - Phone 1 dial attempts Program the number of dial attempts (1 to 15) the communi- cator makes to phone 1 before ending the notification process. The default is 8, which means that the communi- cator makes eight attempts to the first number. Segment 2 - Phone 1 backup control Program the backup control for phone 1. The default is 0. • Program a 0 in segment 2 to cause the NX-6V2 to make the designated number of attempts to phone 2 before setting the f

  • GE NetworX NX-6V2, 5 Underwriters laboratories information The NetworX NX-6V2 holds the following listings from Under- writers Laboratories (US and Canadian): 4. Follower with autoby- pass disabled This zone is instant when the system is armed and no entry or exit delays are being timed. It is delayed 1 time during entry and exit. This zone does not automatically bypass even if enabled in segment 1. 5. Interior follower with autobypass This zone is instant when the system is armed and no entry or exit delay is being timed. It is delayed 1 time durin

  • GE NetworX NX-6V2, NX-6V2-Control Panel Installation Instructions 6 When installing an NX-6V2 in compliance with Underwriters Laboratories, the following instructions must be observed: • Initiating and indicating devices must be rated at 11.5 to 12.4 VDC residential, 12.0 VDC commercial. • Force arming and auto arming must not be enabled. • For residential fire applications, the indicating devices shall be a Wheelock 34T-12 or equivalent. •The listen in feature shall not be enabled. • The siren/bell test must be enabled. The auxiliary outputs controlling the audible device require a minimum cutoff time of 15 minutes for commercial burglary, four minutes for residential appl

  • GE NetworX NX-6V2, 7 Minimum system configurations for UL installations The following requirements apply to residential fire, residen- tial burglary, and commercial burglary installations. • The NetworX NX-6V2 panel is necessary to initiate resi- dential and commercial installations. • At least one compatible keypad is needed for all applica- tions. • The AD10-12 bell and UL Approved bell-housing shall be used for all applications. • Commercial UL applications require the NX-003-C metal enclosure. Supplied screws to be used. • A minimum of two

  • NX-6V2-Control Panel Installation Instructions 8 ANSI/SIA CP-01 requirements CP-01 feature descriptions and specifications are listed in Table 7. The following are requirements for compliance with ANSI/SIA CP-01 standards. Note: Where a conflict exists, UL requirements take precedence over ANSI/SIA requirements. • Minimum system requirements: • One control pan

Related Products and Documents (Control Panel):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Manitowoc K00344 Installation instructions manitowoc/k00344-352.pdf 04 Mar 2023 2
2 Axis 540 series Quick installation manual axis/540-series-YWL.pdf 21 Dec 2023 11 0.29 Mb
3 Akiyama MC-Club Instruction manual akiyama/mc-club-3C4.pdf 14 Apr 2023 12
4 Bella 13267 Panini Grill Instruction manual and recipe booklet bella/13267-panini-grill-8I4.pdf 23 Dec 2023 28
5 Toshiba E-studio 2051c Troubleshooting manual toshiba/e-studio-2051c-K16.pdf 26 Aug 2023 118 12.35 Mb
6 Maytag MDB7759AWW4 Installation instructions manual maytag/mdb7759aww4-3TX.pdf 12 Oct 2023 44

Similar Resources:

  • Johnson Controls

    IFC-200

    (24 pages)
    IFC-200 Technical Manual 444Operating Instructions SectionTechnical BulletinIssue Date 1293© 1993 Johnson Controls, Inc.1Order No. 444-090Operating Instructions Page 3●Switch Functions 3- Acknowledge/Step 3- Alarm Silence 3- Drill 4- System Reset 4●LED Indicators 4- AC Power 4- Fire Alarm 4- Prealarm Warning 4- Supervisory 4- Alarm Silence 5- System Tro …
  • mr. steam

    SMART/TWO

    (6 pages)
    S t3 /VI r-Stea SMART/REMOTE COMPATIBLE SMART/TWO CONTROL INSTALLATION & OPERATION INSTRUCTIONS SMART/TWO BOX CONTENTS 1. SMART/TWO CONTROL 4. INSTALLATION & OPERATION 6. WHITE DECAL 2. CONTROL CABLE INSTRUCTIONS 7. BLACK DECAL 3. TUBE OF SILICONE 5. TEMPLATE 1. LOCATING THE CONTROL INSIDE OR OUTSIDE THE STEAMBATH ENCLOSURE: The SMART …
  • Resolution

    RE656 CryptiX

    (4 pages)
    RE656_Helix-Compatible_HeliPAD_Instructions.doc Page 1 of 4 26-Feb-15 24-Hour Tech Support Line: (715)808-0164 www.ResolutionProducts.com Installation Guide RE656 CryptiX™-Compatible Helipad™ Features • Secure, 4 to 10 digit code to disarm • 1-button arming • 2-way RF, Shows system status • Mounts on wall via VHB® tape, or screws � …
  • Kieback&Peter

    TPC70

    (8 pages)
    Kieback&Peter GmbH & Co. KGTempelhofer Weg 50, 12347 Berlin/GermanyTelefon: +49 30 60095-0, Telefax: +49 30 60095-164www.kieback-peter.de, [email protected] 2.60-10.070-01-ENTPC70Issue 2017-09-13AÄnderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingenvoor …
  • AERMEC

    VMF-E2H

    (28 pages)
    AVMFE2H 1004 - 6795760_00VMF-E2HVMF systemPANNELLO COMANDI ELETTRONICO PER VENTILCONVETTORIELECTRONIC CONTROL PANEL FOR FAN COILSPANNEAU DE COMMANDE ELECTRONIQUE POUR VENTILO-CONVECTEURSELEKTRONISCHE BEDIENTAFEL FÜR GEBLÄSEKONVEKTORENTABLERO DE MANDOS ELECTRÓNICO PARA FAN COILSMANUALE D’USO E INSTALLAZIONEUSE AND INSTALLATION MANUALMANUEL D’UTILIS …
  • Actulux

    SVM EI 24V-5A

    (13 pages)
    Installation instructionControl Panel for Fire VentilationSVM EI 24V-5A / SVM EI 24V-8AFire ventilation Comfort ventilation24VDC max. 5A/8A 1 re ventilation group, 1 comfort group Connection for manual control points, wind- and rain sensor, comfort switches, smoke detectors and Fireman’s Priority Switch.Possibility for bus connection of 35 control pan …

Comments, Questions and Opinions: