  • Bio Bronpi HYDROPOLAR-21, 7.3.4 Menu 3. Set up Clock It sets up the time and date. The card has a lithium battery that allows the clock to work during 3/5 years. 7.3.5 Menu 4. Programme Setting IMPORTANT: Before proceeding to set up the boiler, please check that the time and the date shown are correct; otherwise, the selected programming would be set up depending on the time and date set by default and this could not satisfy your needs. In order to set up our boiler, we need to access the programming menu by pressing button no.3 “SET” only once. With buttons no.5 and no.6 we can move through the menu no.2 “Programme Setting”: To confirm this option, press again button no. “SET”;

  •  Installation Safety Devices It is COMPULSORY to have a pressure gauge to visualize the water pressure during the installation. Warning!!! The closed expansion tank of the installation should have a dimension between 4 and 6% of the total volume of installation; this is why the standard closed expansion tank could be inadequate in case

  • Bio Bronpi HYDROPOLAR-21, 7.3.6 Menu 5. Select Language It allows selecting the languages between those available (Italian, French, English, German, Portuguese, and Spanish.) 7.3.7 Menu 6. Stand-by Mode When the “Stand-by Mode” is “OFF” the boiler will work depending on the water temperatura set selected. Therefore, it will not attend posible demands from the room thermostat of the installation. In the case the “Stand-by Mode” is “ON” the boiler will work depending on the demands from the room thermostat. When activating the “Stand-by Mode” in the boiler, it will show up two different situations dep

  • Bio Bronpi HYDROPOLAR-21, - Combustion chamber control Please check that there are no objects inside the combustion chamber and place inside the appropriate burner for the chosen working mode of the boiler as it is shown in the following pictures. Note that the incorrect placement of the burner may cause problems in the combustion. - Burner - Plug in Once all these points have been checked, please connect the socket with a grounded socket base of ~230V/ 10A retarded.

  • Bio Bronpi HYDROPOLAR-21, 7.6.4 Switching-off Failure during Working Phase .......................................................................................................................................... 32 7.6.5 Pressure Alarm .................................................................................................................................................................................................. 33 7.6.6 Damaged Smoke Extraction Fan Alarm .................................................................................................................................................... 33 7.6.7 Worm Gear Failure Alarm ...........................................................

  • therefore, it stops the transmission to the heating circuit until the first one has reached the point of demand. The installer or Technical Assistance Service, during the ignition of the boiler and inside the technical menu (MENU 10), will have to choose the power (1, 2, 3, 4 or 5) that the boiler must have under the hot sanitary water demand according to the power

  • Bio Bronpi HYDROPOLAR-21, 8 Maintenance and Care The maintenance operations guarantee a proper working of the product during a long time. Not making these maintenance operations will affect the security of the product. 8.1. Burner Cleaning The cleaning of the burner should be made daily: - Remove the burner from its place and unblock the holes with the corresponding poker, which comes together with the boiler. draw excess, fuel type.) AL 8 DEPRESSION The combustion chamber is on depression. Verify that the chamber is hermetic : check locks, gaskets… etc. Check that the gas install

  • Bio Bronpi HYDROPOLAR-21, CLEANING TASKS Daily Weekly Monthly Yearly Technici an User Move away the burner from the compartment and clean up the holes using the poker provided. Hoover the ashes with a vacuum. * * Hoover the ashes settled in the burner compartment. * * Scrapers cleaning. * Empty the ash pan or hoover the ashes compartment when necessary. * * Vacuum the bottom of the pellet tank whenever necessary. * * Clean up the interior of the combustion chamber by hoovering the walls with an appropriate vacuum. * * Clean up the smoke extraction motor, the entire

  • Bio Bronpi HYDROPOLAR-21, INDEX 1 Index ........................................................................................................................................................................................................................... 2 2 Symbol Description .................................................................................................................................................................................................. 4 3 Safety Recommendations ..........................................................................................................................................

  • Bio Bronpi HYDROPOLAR-21, 7.6.7 Worm Gear Failure Alarm It goes off in the event of the endless breakdown. If this happens, the boiler stops and the display will show up the following alarm. Right after, the turn-off stage will be immediately activated. Alarm Code Description Problem Possible Solution AL1 BLACK OUT The boiler has been temporarily without electric current. Press button 4 for a few seconds and let the final cleaning stage to finish. The boiler will come back to the turn-off status. AL 2 SMOKE PROBE Problem with the smoke probe. Check the probe c

  • Bio Bronpi HYDROPOLAR-21, - Use a vacuum to get rid of the ashes in the burner. - Hoover the ashes which are inside the burner place. 8.2. Use of the Scraper A clean smoke chamber guarantees a constant thermal performance during a long time. This type of maintenance should be done, at least, once a day. To do so, you just need to use the corresponding scrapers by activating the handle placed in the side part of the boiler making a backward-forward movement repeatedly. 8.3. Ash Pan Cleaning T

  • Bio Bronpi HYDROPOLAR-21, We need to confirm the access to this programme by pressing button no.3 “SET” and it should show up the following screen: We modify the value “OFF” and select “ON”: Finally, we introduce the times to start and stop to complete the desired setting up. As in the daily programme, if we need to set up only one time to start and stop, the options START 2 and STOP 2 should indicate “OFF.” It is also possible to set up one time to start (START 1: 08.00 h) and stop the boiler manually (STOP 2: “OFF.”) In the same

  • Bio Bronpi HYDROPOLAR-21, Temperature ON/OFF Decreases the ambient thermostat temperature value. 3 Menu (Set) - Access the menu. MENU Access the following level in the submenu. PROGRAMMING Confirms the selected value and move to the following option in the menu. 4 ON/OFF Unblocking WORKING It switches on or off the boiler during 2 seconds, as appropriate. UNBLOCKING Unblocks the boiler and switches it off. MENU / PROGRAMMING Goes back to the previous level menu and saves t

  • By pressing buttons no. 1 and no. 2 we modify the value “OFF” and we set the time of the first start: In this same way we can proceed to set the first time to stop: 09:00 M - 4 - 2 - 02 START 1 DIA OFF M - 4 - 2 - 03 STOP 1 DAY 14:30 M - 4 - 2 - 03 STOP 1 DAY 09:00 M - 4 - 2 - 02

  • Bio Bronpi HYDROPOLAR-21, 7.5.2 Power Supply Failure (Black Out) In the event of a power supply cut-off, when the boiler restarts up it goes straight to the Final Cleaning stage until the boiler temperature reaches the appropriate cooling temperature. Once the final cleaning has finished, the boiler will turn off until the user ignite it again. 7.6 Alarms In case of an anomaly during the working, the electronics of the boiler intervenes and highlights the regularities that have taken place in the different ways of working, depending on the type of fault. Therefore, the boiler could show up different alarms. Every alarm situation makes t

  • Bio Bronpi HYDROPOLAR-21, Minimum fuel consumption Kg/h 1,5 - 1,9 - 2,5 - Maximum fuel consumption Kg/h 4,9 5,6 6 6,5 7,6 8,3 Tank capacity (Kg) 48 54 100 110 100 110 Minimum/maximum power autonomy (h) 32 / 9,8 9,6 53 / 16 17 40 / 13 32 Recommended draw at maximum usable power (Pa) ± 12 ± 12 ± 12 ± 12 ± 12 ± 12 Recommended draw at minimum usable power (Pa) ± 12 - ± 12 - ± 12 - Power consumption (W) 150-250 150-250 150-250 Power consumption during ignition (W) 500 500 500 Water inlet/outlet connection diameter 1" 1&quo

  • Bio Bronpi HYDROPOLAR-21, 7.6.5 Pressure Alarm Circuit hydraulic pressure It goes off when the pressure transducer detects a wrong pressure, either lower than 0.4 bars or higher than 2.5 bars. The system does automatically interrupt the pellet supply and the display will show up in the screen an alarm. Right after, the turn-off stage is activated. Combustion chamber pressure It happens when there is a pressure change in the combustion chamber. The pellet supply is interrupted and the turn-off stage will be immediately acti

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kawasaki FX801V - Datasheet kawasaki/fx801v-6VM.pdf 04 Mar 2023 1
2 Sanyo EM-SL50GRILL Instruction manual sanyo/em-sl50grill-274.pdf 16 Feb 2023 16 0.28 Mb
3 Days HP-3DX Escape Operation & user’s manual days/hp-3dx-escape-SF7.pdf 13 Jun 2023 13
4 Dr.HD D15 Operation & user’s manual dr-hd/d15-W7B.pdf 31 May 2023 69
5 NETGEAR FVX538v1 - ProSafe VPN Firewall Dual WAN Planning manual netgear/fvx538v1-prosafe-vpn-firewall-dual-wan-8NA.pdf 13 Jul 2023 26
6 Optoma PT105 Specification optoma/pt105-194.pdf 19 Dec 2023 3

Similar Resources:

  • Green Mountain

    GMHB227

    (84 pages)
    Co n d ensin g Wal l M o unte d Gas FiredINSTALLATION, OPERATION & MAINTENANCE MANUALManufactured by: ECR International Inc. 2201 Dwyer Avenue, Utica, NY 13501 Tel. 800 253 7900 www.ecrinternational.com PN 240012369 REV. A [08/31/2018]Models GMHB227GMHB380 …
  • A.O. Smith

    HWG-140

    (20 pages)
    PRINTED 0610 315823-001Instruction ManualPLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE.HOT WATER GENERATING SYSTEMS Thank you for buying this water heater. We appreciate your confidence in our products.VERTICAL AND HORIZONTAL MODELS HWG-140 THRU HWG-1000INSTALLATION - OPERATION - SERVICE - MAINTENANCE - LI …
  • Pennant

    PNCH

    (44 pages)
    WARNINGIf the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any e …
  • HydroTherm

    KN-2

    (28 pages)
     is manual is intended only for use by a quali ed heating installer/technician. Read and follow this manual, all supplements and related instructional information provided with the boiler. Install, start and service the boiler only in the sequence and methods given in these instructions. Failure to do so can result in severe personal injury, death or …
  • IBC

    SFT-199

    (7 pages)
    120-241E1| 1 NoteIfconvertingfromnaturalgastopropane,orderthepropaneconversionpartskit(IBCPart#P-802)fromyourauthorizedIBCdistributor.Usethenaturalgasconversionpartskitifthefuelsourceatthesiteusesnaturalgasandthemodulatingtanklessw …
  • Prestige

    Solo 110

    (76 pages)
    Warranty Registration Card must be filled out by the customer and mailed within thirty (30) days of installa-tion in order to gain warranty coverage.When receiving the PRESTIGE Solo unit, any claims for damage or shortage in shipment must be filedimmediately against the transportation company by the consignee.Leave all documentation received with appliance w …

Comments, Questions and Opinions: