HP ProCurve MSM765zl Reference Manual
|
HP ProCurve MSM765zl, CLI commands WAN IP interface context 2-95 end Supported on: MSM710 E-MSM720 MSM760 MSM765zl end Switches to parent context. pppoe auto-reconnect Supported on: MSM710 E-MSM720 MSM760 MSM765zl pppoe auto-reconnect The controller will automatically attempt to reconnect if the connection is lost. no pppoe auto-reconnect The controller will not automatically attempt to reconnect if the connection is lost. pppoe mru Supported on: MSM710 E-MSM720 MSM760 MSM765zl pppoe mru <bytes>
HP ProCurve MSM765zl, CLI commands IPsec context 2-131 peer ip address Supported on: MSM710 E-MSM720 MSM760 MSM765zl peer ip address (<ip address>| any ) Sets the peer ip address for this policy. perfect forward secrecy Supported on: MSM710 E-MSM720 MSM760 MSM765zl perfect forward secrecy Enables PFS. no perfect forward secrecy Disables PFS. preshared key Supported on: MSM710 E-MSM720 MSM760 MSM765zl preshared key <secret> Sets the preshared key. no preshared key Removes the preshared key.
HP ProCurve MSM765zl, CLI commands SNMP notification receiver context 2-143 SNMP notification receiver context Path: View > Enable > Config > SNMP notification receiver Use this context to configure SNMP notification receivers. community Supported on: MSM710 E-MSM720 MSM760 MSM765zl community <community> Specifies the community for this SNMP notification receiver. end Supported on: MSM710 E-MSM720 MSM760 MSM765zl end Returns to a previous context. port Supported on: MSM710 E-MSM720 MSM760 MSM765zl port <number> Specifies the UDP port use for this SNMP notifica
HP ProCurve MSM765zl, CLI commands Virtual AP context 2-104 wireless filters rule input Supported on: MSM710 E-MSM720 MSM760 MSM765zl wireless filters rule input <rule> Adds a custom filter definition for incoming wireless traffic. Use this command to define custom security filters for incoming wireless traffic. Filters are specified using standard pcap syntax (http://www.tcpdump.org/tcpdump_man.html) with the addition of a few HP-specific placeholders. These placeholders can be used to refer to specific MAC addresses and are expanded by the controller when the filter is activated. Once expanded, the
xiv session page .........................................................................................................2-73 transport page......................................................................................................2-73 welcome url.....................................................................................................
HP ProCurve MSM765zl, CLI commands Enable context 2-9 show users Supported on: MSM710 E-MSM720 MSM760 MSM765zl show users [<filter>] Displays all users on this controller. show discrete pin Supported on: MSM710 E-MSM720 MSM760 MSM765zl show discrete pin Displays the state of the discrete pin. config Supported on: MSM710 E-MSM720 MSM760 MSM765zl config Switches to the config context. show all config Supported on: MSM710 E-MSM720 MSM760 MSM765zl show all config Displays all configuration settings that apply to this devic
CLI commands LLDP agent context 2-189 basic-tlv-enable system_name Supported on: MSM710 E-MSM720 MSM760 MSM765zl basic-tlv-enable system_name Enables the system name TLV. no basic-tlv-enable system_name Disables the system name TLV. dot3-tlv-enable Supported on: MSM710 E-MSM720 MSM760 MSM765zl dot3-tlv-enable Enables the 803.3 MAC/PHY TLV. no do
HP ProCurve MSM765zl, 1-3 Management tool This guide uses specific syntax when directing you to interact with the management tool user interface on the controller. Key user-interface elements are identified as follows: end [force] Items enclosed in square brackets are optional. You can either include them or not. Do not include the brackets. In this example you can either include “force” or omit it. firewall mode (high|low|none) Items enclosed in parenthesis and separated by a vertical line indicate a choice. Specify only one of the items. In this example, you must specify ’high’, ’low’, or ’none’. Example Description Example directions in this guide What to do in the user interface S
HP ProCurve MSM765zl, CLI commands Controlled APs base group context 2-150 Controlled APs base group context Path: View > Enable > Controlled APs base group Use this context to configure the base controlled APs group. execute action Supported on: MSM710 E-MSM720 MSM760 MSM765zl execute action (synchronize | accept-suspicious | accept-product | rediscover) Execute an action on the entity’s devices. show config factory Supported on: MSM710 E-MSM720 MSM760 MSM765zl show config [factory] Displays the current configuration as a list of CLI commands. config Supported on: MSM710 E-MSM720 MSM760
HP ProCurve MSM765zl, CLI commands Network profile context 2-187 Network profile context Path: View > Enable > Config > Network profile Use this context to configure network profiles. end Supported on: MSM710 E-MSM720 MSM760 MSM765zl end Go to previous context. name Supported on: MSM710 E-MSM720 MSM760 MSM765zl name <string> Changes the name of current network profile. vlan Supported on: MSM710 E-MSM720 MSM760 MSM765zl vlan Enables a VLAN ID for this network profile. no vlan Disables the VLAN ID for this network profile. vlan Supported on: MSM710 E-MSM720 MSM760 MSM765zl vlan <number>
HP ProCurve MSM765zl, CLI commands Virtual AP context 2-100 ingress interface Supported on: MSM710 E-MSM720 MSM760 MSM765zl ingress vlan <name> Sets the specified interface as the ingress interface traffic will be accepted on. This command takes a selector as its input. A selector is used to differentiate traffic, and decide which parameters should be used to select the VAP (VSC) this user/traffic applies to. egress unauthenticated Supported on: MSM710 E-MSM720 MSM760 MSM765zl egress ( unauthenticated | authenticated | intercepted ) ( default | vlan <vlan- name> | gre &l
HP ProCurve MSM765zl, CLI commands Config context 2-13 New show lacp Supported on: E-MSM720 show lacp Displays E-MSM720 LACP information. New show mac-address Supported on: E-MSM720 show mac-address [<port>] Displays the MAC forwarding table. New show mac-address count Supported on: E-MSM720 show mac-address count Displays the number of entries in the MAC forwarding table. New show trunks Supported on: E-MSM720 show trunks Displays trunking information. New show vlans Supported on: E-MSM720 show vlans Displays VLAN inf
HP ProCurve MSM765zl, CLI commands Virtual AP context 2-102 authentication server access controller Supported on: MSM710 E-MSM720 MSM760 MSM765zl authentication server access controller Use the access controller to authenticate 802.1X or WPA logins. authentication server accounting Supported on: MSM710 E-MSM720 MSM760 MSM765zl authentication server accounting Enables RADIUS accounting for this VSC (VAP). no authentication server accounting Disables RADIUS accounting for this VSC (VAP). authentication server accounting radius profile Supported on: MSM710 E-MSM720 MSM760 MSM765zl authentication server
HP ProCurve MSM765zl, Entering strings 1-8 CLI> Entering strings When entering a value that contains spaces, you must enclose it in quotation marks. For example, if the command syntax is: ssid <name> You must specify one of the following: ssid ANameWithNoSpaces ssid "A name with spaces"
HP ProCurve MSM765zl, CLI commands Default user session profile context 2-75 Default user session profile context Path: View > Enable > Config > Default user session profile Use this context to define default settings for user sessions. Most of these attributes can be overridden by adding settings to a user’s RADIUS account. In this context, all commands add an attribute to the list, in some cases (access-list & mac- address) several entries are added. The "no" form will remove the attributes. ac
HP ProCurve MSM765zl, viii snmp-server version 1.........................................................................................2-29 snmp-server version 2c.......................................................................................2-30 snmp-server version 3.........................................................................................2-30 snmp-server access interface vlan ....................................................................2-30 snmp-server access interface gre ......................................................................2-30 snmp-server access port-1..........................
CLI commands Controlled APs context 2-148 contact Supported on: MSM710 E-MSM720 MSM760 MSM765zl contact <name> Modify the contact. location Supported on: MSM710 E-MSM720 MSM760 MSM765zl location <name> Modify the location. product type Supported on: MSM710 E-MSM720 MSM760 MSM765zl product type (map-320 | map-330 | map-625 | map-630 | msm410 | e-msm430 | e- msm460 |
HP ProCurve MSM765zl, CLI commands Config context 2-53 dynamic key interval Supported on: MSM710 E-MSM720 MSM760 MSM765zl dynamic key interval (5m | 10m | 15m | 30m | 1h | 2h | 4h | 8h | 12h) Specifies how often (in minutes or hours) that the group (broadcast) key is changed for 802.1X and WPA. key chain Supported on: MSM710 E-MSM720 MSM760 MSM765zl key chain <name> Switch to the specified key chain or create a new key chain. no key chain <name> Remove the specified key chain. config-version Supported on: MSM710 E-MSM720 MSM760 MSM765zl config-version <string> Sets a string to identify the user configuration version. radius-server accounting sessio
HP ProCurve MSM765zl, CLI commands Internet port interface context 2-90 ipsec vlan interface Supported on: MSM710 E-MSM720 MSM760 MSM765zl ipsec vlan interface <name> Specifies which VLAN is used by IPsec. no ipsec vlan interface Do not use a VLAN for IPsec.
HP ProCurve MSM765zl, xiii paypal password..................................................................................................2-65 paypal signature...................................................................................................2-65 paypal user-id .......................................................................................................2-65 ads presentation with frameset .........................................................................2-65 authentication http ..............................................................................................2-66 authentication https ......
CLI commands MAC addresses list context 2-186 MAC addresses list context Path: View > Enable > Config > MAC addresses list Use this context to manage the MAC address lists. Each list can contain the MAC addresses of one or more devices. The lists can be assigned to the MAC filter option on a switch port, permitting you to limit switch port access to a specific devices based o
HP ProCurve MSM765zl, CLI commands Session profile context 2-81 idle timeout Supported on: MSM710 E-MSM720 MSM760 MSM765zl idle timeout <number> Sets the default idle time out for all users that do not have a specific limit set in their profile. use idle timeout Use this attribute. no use idle timeout Removes this attribute. intercept traffic Supported on: MSM710 E-MSM720 MSM760 MSM765zl intercept traffic Turn on legal traffic interception. no intercept traffic Turn off legal traffic interception. use intercept traffic Use l
HP ProCurve MSM765zl, CLI commands VLAN interface context 2-120 VLAN interface context Path: View > Enable > Config > VLAN interface View > Enable > Config > Internet port interface > VLAN interface View > Enable > Config > LAN port interface > VLAN interface Use this context to configure VLANs. end Supported on: MSM710 E-MSM720 MSM760 MSM765zl end Switches to parent context. ip address Supported on: MSM710 E-MSM720 MSM760 MSM765zl ip address <ip address>/<mask> Sets a static IP address for the VLAN. Parameters <address> IP address. </mask> Subnet mask in CIDR format. Specifies the number of bits in the ma
HP Compaq 6715b Controller Maintenance and service manual
Compaq 6715b |
HP Officejet Pro 7500 Series Controller Datasheet
Officejet Pro 7500 Series |
HP NEOVIEW 544530-001 Controller Technical documentation
NEOVIEW 544530-001 |
HP Compaq tc4400 Controller Operation & user’s manual
Compaq tc4400 |
HP Pro100B Controller Installation manual
Pro100B |
HP CD-WRITER Plus Controller Operation & user’s manual
CD-WRITER Plus |
HP 615N - JetDirect Print Server Controller Setup manual
615N - JetDirect Print Server |
HP ProLiant BL660c Controller Manual
ProLiant BL660c |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Vizio | E701i-A3E | Operation & user’s manual | vizio/e701i-a3e-W27.pdf | 08 Mar 2024 | 67 | 10.7 Mb |
2 | Sun Microsystems | Sun Fire X4140 | Service manual | sun-microsystems/sun-fire-x4140-6RV.pdf | 11 Feb 2023 | 168 | |
3 | LG | 29FS2ALX | Service manual | lg/29fs2alx-9BM.pdf | 06 Mar 2024 | 31 | |
4 | NEFF | S5443X2GB | Operating instructions manual | neff/s5443x2gb-53U.pdf | 01 Jul 2022 | 27 | |
5 | Kenmore | 66575776891 | Installation instructions manual | kenmore/66575776891-395.pdf | 02 Sep 2023 | 17 | |
6 | Chef's Choice | JNR4 Series | Owner's manual | chef-s-choice/jnr4-series-YMW.pdf | 11 Mar 2024 | 37 |
ABB
MODEL SHOWN: ACS 320 VFD KEYPADS IN E-BOXSUPPLEMENTAL MANUAL FACTORY-INSTALLED ABB VARIABLE FREQUENCY DRIVES (VFD) IN RENEWAIRE(ERV) VENTILATORSRENEWAIRE.COMTABLE OF CONTENTS Product info ............................ 2Installation ........................... 3-9Operation ......................... 10-16VFD KEYPADS IN E-BOX
…
ACS320 series(16 pages) |
SEW-Eurodrive
Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ ServicesAC Motors DR/DV/DT/DTE/DVE, Asynchronous Servo Motors CT/CVOperating InstructionsA6.C01Edition 08/200411291613 / EN
…
DR Series(72 pages) |
Resol
DeltaSol® BSwww.resol.deThanks for buying a RESOL.Read this manual carefully to get the best perfomance from this unit.RESOL DeltaSol® BSMountingConnectionHandlingFault localizationExamples
…
DeltaSol BS(20 pages) |
Goldline
Above-Ground Pool Automationby 888-921-POOLwww.goldlinecontrols.comQuestions? Refer to www.goldlinecontrols.com for latest manualrevisions, additional information and helpful service. Or, youmay visit your local Authorized Aqua Trol® Dealer or call 888-921-POOL (7665) for assistance.ELECTROLYTIC CHLORINE GENERATORBASIC POOL MAINTENANCE REQUIREMENTSNorth K …
aqua trol(20 pages) |
Green Air Products
English Description Recommended for indoor use only. The THC-1 Total Humidity Controllers is specifically designed to manage humidifying and dehumidifying equipment, including fans in an indoor environment or zone. The THC-1 switches easily between humidify and dehumidify control. Safety Instructions • Mount unit on a wall or support structure using mounti …
THC-1(2 pages) |
Ltech
54. M203 Remote:175mm44mm170mm30mmRUNM 1 2 M203 RemoteRemoteRemote holderController60mm104mm14mm63mm108mmDMX-SPI-203 Controller:DMX-SPI-203LED ControllerDMX-SPI-203 controls LED with the following compatible ICs: UCS6909, UCS6912, LPD8803, LPD8806, TM1803, TM1804, TM1809, TM1812, UCS1903, UCS1909, UCS1912, UCS2903, UCS2909, UCS2912, TLS3001, …
DMX-SPI-203(3 pages) |
HP Laptop 820820 Operation & user’s manual - 328I3G 820, 115 |
COP-USA Security Camera CB24COP-USA CB24 User Manual (Doc Type: Security Camera Specifications) CB24, 1 |
Elo TouchSystems Monitor IDS 6553LMonitor Operation & user’s manual (Elo TouchSystems IDS 6553L) IDS 6553L, 37 |
Life Fitness Home Gym Pro 2 Series PSTESEHome Gym PDF Parts manual Pro 2 Series PSTESE, 18 |
HP Laptop Jornada 430User Manual: HP Jornada 430 (9Z9994, Upd.Wednesday 13-09-2023) Jornada 430, 16 |
Wilson Electronics Antenna 301134#1Y57N5: 301134 Antenna Installation manual 301134, 4 |
Vertex Standard Radio VX-6000Radio PDF Specifications VX-6000, 6 |
Voipac Telephone NetPhone NP210PDF Manual (@69D282), Voipac NetPhone NP210 Telephone (05th Oct 2023) NetPhone NP210, 34 |
Mitsubishi Monitor Diamond Scan 90EMitsubishi Monitor Diamond Scan 90E Operation & user’s manual Diamond Scan 90E, 31 |
Electrolux Dryer 60006000 (Dryer ePDF Manual, #31795N) 6000, 84 |
jWIN CD Player JX-CD492jWIN CD Player JX-CD492 Owner's manual JX-CD492, 16 |
BALAY Dishwasher 3VK730XC - annexe 13VK730XC - annexe 1 Instruction manual - 279397 3VK730XC - annexe 1, 24 |