Manualios.com

Siemens HC15 Getting Started Manual

Siemens HC15 Manual Online:

3.55, 1535 votes
Siemens HC15 User Manual
Siemens HC15 User Guide
Siemens HC15 Online Manual

Text of Siemens HC15 User Guide:

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 24 of 31 2007-01-22 Select the option Set up my connection manually and click Next. Select Connect using a dial-up modem and click Next. Select the modem driver that you want to use for the dial-up connection. Click Next to continue. Type an appropriate Connection name and click Next.

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 9 of 31 2007-01-22 2.4 Installing USB and Ethernet Drivers The HC15 driver package consists of three virtual devices, one by one automatically installed: • Siemens USB Com Port driver • Siemens Wireless Ethernet Adapter driver • Siemens HSDPA USB Modem driver During the installation, the HC15 USB interface will be assigned two virtual COM ports, one for the virtual modem port and one for the virtual application port. Windows will automatically allocate the next available COM port to each virtual interface. After plugging the USB cable Windows detects the HC1

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 12 of 31 2007-01-22 2.5 Installed Devices and Tools After successful installation, the devices listed below are available. Under Windows XP, you can use the Device Manager to check that all components are properly installed and configured. Siemens HSDPA USB Modem • AT command and data interface, also referred to as “Modem” port if queried using the AT^SQPORT command. • Intended particularly for HSDPA and GPRS data connections. • The virtual COM port Windows has assigned to the AT command and data interface is listed in the Device Ma

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 22 of 31 2007-01-22 Terminating the dial-up connection To stop a HSDPA or GPRS data connection disconnect the dial-up connection. This can be done in two ways: 1. Double-click the dial-up network connection icon in the system tray. In the resulting connection status dialog press the Disconnect button. 2. The other way is available on the Network Connections page of the Control Panel: Right- click the

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 26 of 31 2007-01-22 4.1.2 Configuring a Dial-up Connection Every newly created dial-up connection should be configured before using it to establish a PPP connection. Open the Control Panel, double-click Network Connections, select the dial-up connection you want to configure. In the resulting Connect… dialog, press the Properties button. On the General tab, select the mo

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 4 of 31 2007-01-22 1 Introduction HC15 is the first Siemens wireless module to offer UMTS and GSM capability on the same device. The benefit is that the HC15 includes HSDPA capability in a UMTS network and also all common mobile connectivity features like voice, short messages, GPRS and EGPRS. The HC15 modules need to connect to an adequate host device, such as the Evaluation Board DSB75. Designed to help application manufacturers and system i

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 6 of 31 2007-01-22 2.2 Installing Siemens Connection Manager and Preparing Driver Installation Before you start unpack the “HC15_01000_usb_ndis_driver.zip” file to a folder on your Windows XP system. Double-click the “autorun.exe” file from the dezipped driver package. The following installation sequence will run: Press Install to start the installation of the Connection Manager. The progress of the installation will be indicated. It is possible that there are up to 3 warning messages saying that the dr

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 15 of 31 2007-01-22 3 Using the HC15 Module The following examples show the basic steps required to register to the network, to select UMTS mode or GSM mode and to attach to HSDPA or GPRS. The examples are based on a UICC card provisioned by the German network operator T- Mobile. The used UICC card is capable of UMTS and GSM and enables the subscriber to switch back and forth between both networks. 3.1 AT Command Interpreter AT commands can be entered on two interfaces of the HC15 module: • Siemens HSDPA USB Com Port • Siemens HSDPA USB Modem Yet, we recommend that the Siemens

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 5 of 31 2007-01-22 2 Installation and Configuration 2.1 Technical Requirements for Running HC15 on DSB75 • HC15 module • HC15 driver package contained in a zipped file: “HC15_01000_usb_ndis_driver.zip”. Please follow the installation guidelines provided below: First install the Connection Manager and prepare the driver installation (see chapter 2.2), then connect the HC15 to the DSB75 (see chapter 2.3), finally install the drivers (see chapter 2.4). NOTE: If driver

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 19 of 31 2007-01-22 3.8 Making a Voice Call (MO) The commonly used GSM 07.07 dialing command ATD is fully applicable both in the UMTS and the GSM network. To make a mobile originated voice call enter ATD, type the destination number and add a semicolon. The result code OK will be returned immediately after dialing, prior to call setup. To end the call, use the AT+CHUP command (ATH is for data calls only). atd030111111111; OK at+clcc +CLCC: 1,0,0,0,0,"030111111111",129,"Tom" AT+CHUP OK at+clcc OK Th

  • Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 13 of 31 2007-01-22 Siemens USB Com Port • AT command interface, also referred to as “Application” port if queried using the AT^SQPORT command. • Mainly intended for controlling the HC15 module, for receiving URCs, can be used also for sending, receiving, writing and reading sh

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 16 of 31 2007-01-22 3.2 Switching on the HC15 The HC15 can be started by pressing the IGT key of the DSB75. Please wait approximately 2 seconds before using the module, for example before entering AT commands. Disconnecting and plugging the USB cable during operation is not supported. 3.3 Switching off the HC15 To shut down the HC15 module, enter the AT^SMSO command. This enables the ME to save all data and perform an orderly shutdown. AT^SMSO OK The ME switches off. The HC15 module can also be switched off by using t

  • Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 10 of 31 2007-01-22 Now the installation of the “Siemens Wireless Ethernet Adapter” will start. Click Next. The progress of the driver installation is indicated. It is possible that there are up to 3 warning messages saying that the drivers are not digitally signed. Please

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 7 of 31 2007-01-22 2.3 Installing the Hardware To properly connect the HC15 module and all accessories to the DSB75 Board follow these steps: • Check that the all switches of the DSB75 Board are set as described in the Appendix. • Attach the adapter board to the 80-pin header located on the DSB75 Board. Take gentle care that all pins are aligned correctly, then press down evenly on the adapter board until it is firmly seated. • Connect t

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 2 of 31 2007-01-22 Title: Getting Started with HC15 Version: 01 Date: January 22, 2007 DocId: HC15_startup_v01 Status: Confidential / Preliminary General note Product is deemed accepted by Recipient and is provided without interface to Recipient’s products. The Product constitutes Preview Release version and code and may be changed substantially before commercial release. The Product is prov

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 3 of 31 2007-01-22 Contents 1 Introduction .................................................................................................................4 1.1 Related Documents .......................................................................................... 4 2 Installation and Configuration....................................................................................5 2.1 Technical Requirements for Running HC15 on DSB75..........

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 29 of 31 2007-01-22 4.2 Abbreviations Abbreviation Description APN Access Point Name CHAP Challenge Handshake Authentication Protocol GPRS General Packet Radio Service HSDPA High-Speed Downlink Packet Access IP Internet Protocol ME Mobile Equipment MO Mobile Originated MT Mobile Terminated PAP Password Authentication Protocol PDP context Packet Data Protocol context TA Terminal Adapter TE Terminal Equipment UICC Universal Integrated Circuit Card UMTS Univ

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 18 of 31 2007-01-22 3.6 Attaching to the HSDPA or GPRS Network After PIN authentication, the HC15 module automatically tries to attach to the HSDPA or, accordingly, GPRS network. at+cgatt? +CGATT: 1 OK Querying the current service state. The ME is attached, depending on the selected network type (see AT+COPS), it is either attached to the HSDPA or GPRS service. 3.7 Defining the PDP Context Use the AT+CGDCONT command to configure the correct provider settings. The PDP context is stored non-volatile. Write command: AT+CGDCONT=<cid>[,

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 25 of 31 2007-01-22 In the Phone number box, put the dial string *99***1# commonly used to access the GPRS network. Note: The number “1” added before the hash determines that the first PDP context shall be used. The number must be identical to the <cid> value set with AT+CGDCONT (see Chapter 3.7) Depending on the network, you may be required to put a User name and a Password for the dial-up con

  • Siemens HC15, Getting Started with HC15 Confidential / Preliminary s HC15_startup_v01 Page 23 of 31 2007-01-22 4 Appendix I 4.1 Adding and Configuring a New Dial-Up Connection This chapter describes how to create and configure a new dial-up connection when using the installed Siemens HSDPA USB Modem to access the GPRS or HSDPA network: 4.1.1 Adding a New Dial-up Connection Open the Control Panel, double-click Network Connections, select Create a new connection on the left side of the panel. The Network Connection Wizard opens. Click N

Related Products and Documents (GPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 KitchenAid KBNU487TSS00 Parts list kitchenaid/kbnu487tss00-K86.pdf 12 Nov 2023 4
2 Sony XM-1252GTR - Power Stereo Amplifier Operating instructions manual sony/xm-1252gtr-power-stereo-amplifier-9I3.pdf 11 Aug 2023 19 2.48 Mb
3 AT&T E2811 Operation & user’s manual at-t/e2811-9Z5.pdf 30 Jan 2023 65 5.73 Mb
4 Tekvox TekTouchPad Installation manual tekvox/tektouchpad-6CS.pdf 15 May 2023 4
5 Fuji Xerox DocuColor 5065II Operation & user’s manual fuji-xerox/docucolor-5065ii-99S.pdf 11 Apr 2023 416
6 Digitus DN-60021-1 Operation & user’s manual digitus/dn-60021-1-5C2.pdf 05 Oct 2022 5

Similar Resources:

  • Alpine

    INA-W900

    (157 pages)
    Designed by ALPINE Japan68-14470Z66-AENFRESIN-DASH GPS NAVIGATION RECEIVERINA-W900• OWNER’S MANUALPlease read before using this equipment.• MODE D’EMPLOIVeuillez lire avant d’utiliser cet appareil.• MANUAL DE OPERACIÓNLéalo antes de utilizar este equipo.RRALPINE ELECTRONICS MARKETING, INC.1-1-8 Nishi Gotanda,Shinagawa-ku,Tokyo 141-0 …
  • C-LOGIC

    3400

    (2 pages)
    Comprobador de redes de comunicaciónC-LOGIC 3400SKU: CLOGIC3400CBINTMANUAL DE INSTRUCCIONESESPAÑOL ESPEl C-LOGIC 3400 es una comprobador de cables de red portátil e ideal para la instalación, comprobación, mantenimiento e inspección de cables coaxiales (BNC) y cables UTP y STP. También ofrece la comprobación rápida y cómoda del estado de líneas t …
  • Sony

    Cybershot,Cyber-shot DSC-T50

    (3 pages)
    VGN-UX280P7VAIO®UX Series Micro PCSony Electronics Inc. • 16530 Via Esprillo • San Diego, CA 92127 • 800.222.7669 • www.sony.comSpecificationsGeneralComputer Type: Micro PCType of Use: Ultra PortableAction Buttons: Mouse Left, Mouse Right, Scroll,Magnify Screen (Zoom In/Out), Capture, Center Button, Wireless LAN, On/Off,VAIO Touch LauncherKeyboard: …
  • Eagle

    CUDA 250 - ADDITIONAL

    (172 pages)
    Pub. 988-0152-101 www.eaglesonar.com & Cuda 250i S/MapFish-finding Sonar & GPSInstallation and OperationInstructionswww.Busse-Yachtshop.de email: [email protected]
  • Alpine

    INE-W940

    (97 pages)
    Designed by ALPINE Japan68-25285Z01-AENFRESThank you for purchasing this Alpine product. Please take a moment to protect your purchase by registering your product now at the following address: www.alpine-usa.com/registration.You will be informed of product and software updates (if applicable), special promotions, news about Alpine, and entered for a chance t …
  • Kantronics

    KML-5000 TraveLog

    (23 pages)
    DWG ID: 181-0104-00Date: 2006-01-24KANTRONICSKML-5000 TraveLogUSER MANUALKantronics Co., Inc.3115 West 6th Street, Suite ALawrence, Kansas 66049Phone: 785-842-7745Fax: 785-842-2031Web: http://www.kantronics.com …

Comments, Questions and Opinions: