Manualios.com

Exalt EX-5i-DS3-GigE Installation And Management Manual

  • EX-5i-DS3-GigE Radio
  • matNqCXJ6BaDc
  • Installation And Management Manual
  • PDF / Adobe Acrobat Reader
  • 133

Exalt EX-5i-DS3-GigE Manual Online:

3.8, 2732 votes
Exalt EX-5i-DS3-GigE User Manual
Exalt EX-5i-DS3-GigE User Guide
Exalt EX-5i-DS3-GigE Online Manual

Text of Exalt EX-5i-DS3-GigE User Guide:

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 108 202675-005 2011-08-30 Regulatory Compliance As of this printing, Exalt Communications, Inc. has approvals for the products that are covered by this manual in the USA (FCC) and Canada (IC). If your application is for a different country, check with your Sales Representative for the current status. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled enviroment. This equipment should be installed and operated with minimum distance 677cm between the radiator & your body.

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios viii 202675-005 2011-08-30 About this Document This manual provides a complete description of the EX-i Series FDD family of Exalt Digital Microwave Radios and related software. This manual provides planners, engineers, installers, system administrators, and technicians general and specific information related to the planning, installation, operation, management, and maintenance of these devices. Revision History Icons T

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 33 2011-08-30 • Green indicates the system is communicating and all functions are normal • Yellow indicates a minor non-traffic affecting alarm condition • Red indicates a major traffic affecting alarm condition The left panel summarizes the alarm conditions of the local radio (the radio that matches the IP address). The information displayed is the IP address and the endpoint identifier (Radio A or Radio B). The right

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 50 202675-005 2011-08-30 Ethernet Interface Configuration Page This page allows the administrator to set the muting, alarm, and duplex settings of the ETH1, ETH2, and ETH3 connections, and allows determination of the management information for in-band (carried over the air and available from both Ethernet connectors on either end of the link) or out-of-band (not carried over the air and only available from the local PoE connector). Figure 32 Ethernet Interface Configuration page The managemen

  • Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 58 202675-005 2011-08-30 MHS Configuration Page This page provides the capability to configure the system for Monitored Hot Standby (MHS). These configurations implement a second terminal at one or both ends of the link for hardware protection and/or path protection. MHS cannot be configured

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 107 2011-08-30 Changes or modifications not expressly approved in writing by Exalt may void the user’s authority to operate this equipment. This device must be professionally installed. To comply with regulations, the output power of this device may need to be adjusted in accordance to the associated transmission system. See RF Output Power Setting for details. The antenna associated with this device shall be mounted in a location that is at least 10.5'/32m away from humans who may be subject to long-term or continuous exposure. Canada Compliance The 6 and 11GHz EX-i Series FDD radios oper

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 110 202675-005 2011-08-30 Licensing 6 and 11GHz Models Frequency coordination for EX-i Series FDD radios is normally required by local regulations. To obtain and maintain licensing, consult the licensing authorities. United States In the US frequency coordination is often conducted by a Certified Frequency Coordinator (CFC), who coordinates spectrum allocation for the Federal Communications Commission (FCC). CFCs assist applican

  • Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 71 2011-08-30 design goals, and compare actual performance to these expectations to determine if any improvements are necessary or if other problems may be causing excessive ES. • Unavailable Seconds (also called UAS) are similar to ES, but this counter keeps track of every second wher

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 97 2011-08-30 • New construction nearby either end of the link, or along the path • Tree growth, flooded fields, or changes in rivers/lakes along the path Verify that configurations are set as follows: • Frequency pair matches (oppositely) at each end of the link • Mode (Modulation) matches at each end of the link • Bandwidth matches at each end of the link • Ethernet interfaces are enabled, as desired • Ethernet interfaces are selected for Traffic, Management, or Traffic plus Management, as desired • T1/E1 enabling matches at each end of the link �

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 40 202675-005 2011-08-30 • Radio Reboot Trap: This trap is sent after any radio reboot to inform the manager of the reboot status. • Local Link Status Trap: This trap is sent when Link is in an errored state (equivalent to the Link LED on the radio front panel or the Link status bar in the upper-left of the Exalt GUI window). Independent traps can be set for the main and diversity links (when configured for space diversity). •

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 112 202675-005 2011-08-30 RFS SPF2-52A 2-foot Dish 27.9 6.2 RFS SPF3-52A 3-foot Dish 31.4 4.2 RFS SPF4-52A 4-foot Dish 33.9 3.1 RFS SPF6-52A 6-foot Dish 37.4 2.1 RFS SDF4-52A 4-foot HP Dish 33.9 3.1 RFS SDF6-52A 6-foot HP Dish 37.4 2.1 Table 7 Supported 5GHz antennas (Continued) Manufacturer Model # Description Midband Gain (dBi) 3dB (Azimuth/Elevation) Beamwidth (degrees)

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 1 2011-08-30 Introduction Exalt Communications, Inc. thanks you for your purchase. Our goal is to build the highest quality, highest reliability digital microwave radio products. This commitment to quality and reliability extends to our employees and partners alike. We appreciate any comments on how we can improve our products, as well as your sales and Customer Care experience. Related Documentation and Software This manual makes reference to other documentation an

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 30 202675-005 2011-08-30 Make Connections It is recommended that one radio at a time be configured, on a bench, before taking the radios to the field for installation. Terminate the RF connector with a 50-Ohm termination or a fixed attenuator of at least 20dB (see Power ). Once connected to the radio using Ethernet, log in to the Exalt GUI. Log In Use the following steps to log in to the Exalt GUI. 1 Open a browser window. Microsoft Internet Explorer is the recommended browser. Netscape, Mozilla, and Firefox

  • Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 57 2011-08-30 Figure 37 External (remote) loopback Figure 38 External (local) loopback When a local TDM port is configured for External (remote) loopback, it is the same as configuring the remote radio for External (local) loopback. Note: For DS3 interfaces, the implementation is slightly dif

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 12 202675-005 2011-08-30 Record Keeping After installation, record the following items for ongoing maintenance and future troubleshooting. Keep a record for each end of the radio link and store a copy of these records at the radio location, at the opposite end radio location, and a central record storage location. • GPS coordinates for antenna locations at each site • Antenna heights above ground level (AGL), as mounted • Antenna model numbers, serial numbers, and specifications • Antenna polarization as mounted • Length/type of primary transmission lines at each site

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 63 2011-08-30 Syslog Configuration Page Syslog serves as a remote means to receive event log messages (configuration and alarm state changes) for network management and/or record keeping. Figure 43 Syslog Configuration page To enable the syslog, check the Remote host logging option and input the IP address for the remote host. See Event Log Page for filter descriptions.

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 3 2011-08-30 pairs, antenna polarization, and other aspects of the link. Also, it is required that any regulations that may apply to peripheral equipment, installation, and cabling of the system that may be regulated for human safety, electrical code, air-traffic control, and other safety-related categories be examined and complied with. In almost all cases, the product itself must be authorized for use in your country. Either Exalt or

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 72 202675-005 2011-08-30 When ACM is enabled on the System Configuration Page, the Performance page lists ACM statistics (Figure 49). Figure 49 Performance page with ACM statistics The ACM Performance table provides a reference of the maximum and minimum modulation settings that are selected on the System Configuration Page and their associated throughput. The Active column illustrates the current radio configuration. Note: Resetti

  • Exalt EX-5i-DS3-GigE, Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 73 2011-08-30 ATPC Statistics Page This page provides timer information for the Automatic Transmit Power Control (ATPC) function (Figure 50). Regulations require timers for ATPC and ATPC may not operate over the authorized time (up to 5 minutes at maximum allowed power without returning to target RSL). In addition to providing statistics, the timer can be reset. Figure 50 ATPC Statistics page

  • Exalt Installation and Management Guide EX-i Series FDD Digital Microwave Radios 202675-005 115 2011-08-30 PERSONAL INJURY, OR SEVERE PHYSICAL OR ENVIRONMENTAL DAMAGE. EXALT AND ITS SUPPLIERS AND LICENSORS SPECIFICALLY DISCLAIM ANY EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR ANY HIGH-RISK USES LISTED ABOVE. c. REGARDLESS OF WHETHER ANY REMEDY SET FORTH HERE

Related Products and Documents (Radio):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Line 6 Helix 2.0 Owner's manual line-6/helix-20-N2C.pdf 12 Apr 2023 59
2 Dimplex DF3015 Parts and service manual dimplex/df3015-252.pdf 18 May 2023 16
3 AUDIOLINE Watch & Care V110 Operating instructions manual audioline/watch-care-v110-327.pdf 08 May 2023 28
4 Asus A88X-PLUS Operation & user’s manual asus/a88x-plus-D29.pdf 05 Jul 2023 70 5.38 Mb
5 Destinator 6 Operation & user’s manual destinator/6-555.pdf 13 Oct 2022 45 4.14 Mb
6 SURF Communication Solutions Orion-MCU Operation & user’s manual surf-communication-solutions/orion-mcu-C3E.pdf 15 Sep 2023 58

Similar Resources:

  • Renkforce

    1404214

    (82 pages)
    BedienungsanleitungDAB5 DAB+ Radio Best.-Nr. 1404214 Seite 2 - 21 Operating InstructionsDAB5 DAB+ Radio Best.-Nr. 1404214 Page 22 - 41 Mode d´emploiRadioDAB+ DAB5 Best.-Nr. 1404214 Page 42 - 61 GebruiksaanwijzingDAB5 DAB+ radio Best.-Nr. 1404214 Pagina 62 - 81 …
  • Oregon Scientific

    WR103NX

    (2 pages)
    QUICK START GUIDENATIONAL WEATHER SERVICEThe National Weather Service (NWS) is one of the six scientific agencies that make up the National Oceanic and Atmospheric Administration (NOAA). It provides weather, hydro-logic, and climate forecasts and warnings for the United States, its territories, adjacent waters and ocean areas. NOAA All Ha …
  • Mercury

    Sable 2008

    (2 pages)
    MERCURYMARINERHybrid2008NAVIGATIONSYSTEM (if equipped) � …
  • Aluratek

    321

    (1 pages)
    3216549870OKStream Internet Radio from your WiFi / wireless 802.11 B / G routerConnect your local CAT5 Ethernet cable to stream Internet RadioPlug in any USB Drive and listen to your music filesBCABCA1CONNECT2LISTEN Built-in WiFi OR ORIntegrate the AIRMM01Finto your home theatersystem via the RCA jacksRemote includedSimply connect to your receiver or externa …
  • UNIMO Technology

    PJ-400NW

    (10 pages)
    -1-USER'S MANUALRead this information before using your product.Acknowledging Special Precautions and the FCC Notice Cautions.Modifications not expressly approved by the party responsible for compliance could void theuser's authority to operate the equipment.FCC compliance InformationThis device complies with part 15 of FCC Rules.Operation is subje …
  • RuarkAudio

    R2 mk3

    (256 pages)
    User guideBrugervejledningBedienungsanleitungGuía del usuarioGuide de l’utilisateurManuale dell’utenteGebruikershandleiding Brukerveiledning사용자 가이드ENDADE ES FRITNLNOKRTabletop StereoR2 mk3User guideEN …

Comments, Questions and Opinions: