  • SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 5 Advanced Setup Dial Backup SIEMENS 47 Dial Backup Use the Dial Backup option to configure a backup connection to the Internet through an internal V.90 (model 5835 only) or an external asynchronous modem connected to the console port. This backup connection can be activated in the event of WAN service i

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 5 Advanced Setup QoS SIEMENS 44 5. In Source IP, select one of the following: • From/To: Enables source address checking. Specify the source IP address or range of IP addresses that must match for this policy to be used. • Do not care: Disables source address checking. 6. In Dest IP, select one of the following: • From/To: Enables destination address checking. Specify the destination IP address or range of IP addresses that must match for this policy to be used. • Do not care: Disables destination address checking. 7. In Protocol, select one

  • Siemens 5935, SIEMENS 29 Chapter 4 User Setup This chapter describes how to set up users on the router and control their access to router functions and to the Internet. The features that control users and their access are listed below. To access one of these options, click the link on the left navigation pane of the Router Information page. User Management When you select User Management from the left navigation pane of the Router Information page, the User Management page is displayed. Use this page to add, delete, edit, and view user accounts. You can also use this page to configure secur

  • SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 6 Security Setup Stateful Firewall SIEMENS 65 Stateful Firewall Stateful Firewall varies from the IP Filtering Firewall in that it gathers and maintains state information about each session. IP Filtering Firewall examines the packet’s header information and matches it against a set of defined rules.

  • SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 5 Advanced Setup Switch Management SIEMENS 51 Switch Mirror Configuration The router supports traffic mirroring on the Ethernet switch. This means that Ethernet traffic from any of the Ethernet ports is mirrored to a target port for analysis. This function facilitates the unobtrusive monitoring of source port activity. To

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 3 Easy Setup Select Protocol SIEMENS 24 Point-to-Point Protocol over Ethernet over RFC1483 If you selected Point-to-Point Protocol over Ethernet over RFC 1483 from the Wan Interface page, the Point-to-Point Protocol over Ethernet over RFC 1483 page is displayed when you click Next. To configure Point-to-Point Protocol over Ethernet over RFC 1483: 1. Enter PPPoE User Name and Password to use for authentication when establishing a WAN connection using PPPoE protocol. 2. In Service Name, enter the domain name of your network ser

  • Siemens 5935, SIEMENS 1 Chapter 1 Product Specifications Front Panel for 5930 The following table explains the LEDs that appear on the front panel of the Siemens 5930 Business Gateway. Back Panel for 5930 The following table describes the various connections on the back panel of the Siemens 5930 Business Gateway. Light Color Indications Power Green Off Power is ON Power is OFF Test Yellow: Yellow flashing: Green: (2 sec blink) Off: Running Power On Self Test Self Test Failure Self Test successful (heartbeat) Router is shut down WAN Yellow: Yellow flashing: Green: Off: Establishing DSL modem link Establishing DSL throughput DSL modem link successful DSL modem link is sh

  • SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 4 User Setup Change Password SIEMENS 37 Change Password User passwords are changed from the Change Password page. To change a user password: 1. Click Change Password from the left navigation pane on the Router Information page. This displays the Change Password page. 2. Enter the new password for the Current User in

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 5 Advanced Setup Router Clock SIEMENS 40 Router Clock Use the Router Clock option to set the date and time on the router. To set the current date and time on the router: 1. Click Router Clock on the left navigation pane of the Router Information page. This displays the Current Date and Time page. 2. The current date and time from your PC are displayed in the field labeled Current Date and Time. To synchronize the date and time on your router with the current date and time displayed, click Synchronize Router Clock.

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 2 Installation PC Configuration SIEMENS 12 PC Configuration Your PC must be configured to use the TCP/IP protocol suite over the Internet, and to accept Dynamic Host Configuration Protocol address assignments from the router. Although this is the default settings for the PC, it is a good idea to verify that they have not been changed. Each supported PC Operating System varies slightly in how the configuration windows are presented. Select the Operating System installed on the PC connected to the router from the list below and follow the associated procedure. Windows 98/ME 1. Click Start >Control Pan

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 7 Monitoring Router Diagnostics SIEMENS 85 Interface Information Select Interface information from the drop down menu and click Execute to display interface information. ATM Statistics Select ATM Statistics from the drop down menu and click Execute to display ATM statistics.

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 5 Advanced Setup Dial Backup SIEMENS 48 Internal Modem The following Dial Backup Configuration page is displayed during Dial Backup configuration if you selected Internal Modem for the connection. To configure the internal modem for dial backup: 1. In Backup Failover Timeout, enter the number of minutes that must pass during a WAN link failure before switching to the backup port. This guards against too frequent switching back and forth between the WAN link and the backup port. The default minutes is 3. 2. In Retry WAN Timer, enter the number of minutes that must pass before

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 6 Security Setup Secure Shell SIEMENS 62 Load Keys Diffie-Hellman is the key exchange system used for authentication in the establishment and maintenance of SSH connections. The key exchange requires a Public Key and a Private Key. This key pair can either be loaded from a source file or generated by the router. This section describes how to load the key pair from a source file. Refer to the section title Key Generator for details on generating the key pair on the router. To load the key pair from a source file: 1. Click Load Keys on the left navigation pane of the Secure Shell (SSH) Confi

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 6 Security Setup SNMP SIEMENS 58 SNMP Simple Network Management Protocol (SNMP) exchanges messages between a management client and a management agent. Messages contain requests to get and set variables that exist in network nodes, thus allowing a management client to obtain statistics, set configuration parameters, and monitor events. Communication with the SNMP agent can occur over the LAN or WAN connection. To configure SNMP: 1. Click SNMP on the left navigation pane of the Router Information P

  • Siemens 5935, • Siemens Subscriber Networks’s limit of liability under the limited warranty shall be the actual cash value of the product at the time the end user returns the product for repair, determined by the price paid by the end user for the product less a reasonable amount for usage.Siemens Subscriber Networks shall not be liable for any other losses or damages. • The end user will be billed for any parts or labor charges not covered by this limited warranty. The end user will be responsible for any expenses related to reinstall

  • SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 6 Security Setup Stateful Firewall SIEMENS 70 Delete Firewall Rules To delete firewall rules: 1. Click Firewall Rules from the left navigation pane of the Stateful Firewall Configuration page. This displays the Firewall Rule Configuration page. 2. Click Delete. This expands the Firewall Rule Configuration page. 3. Sele

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 4 User Setup User Management SIEMENS 34 Configure the Radius Server Remote Authentication Dial In User Service (RADIUS) is client-server based access control and authentication feature. The RADIUS client resides locally on the router and works in conjunction with a variety of RADIUS Server applications. • The client is responsible for passing user information to designated RADIUS servers, then acting on the returned response. • RADIUS serve

  • Siemens 5935, SIEMENS 39 Chapter 5 Advanced Setup This chapter describes how to configure advanced features on the router. Advanced features are listed below. To configure one of these features, click the link on the left navigation pane of the Router Information page. Router Clock Set the date and time on your router. DHCP View and configure the current DHCP settings. Quality of Service (QoS) Configure QoS, which actively manages network resources to sustain service levels for priority applications. Routing Table Co

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 5 Advanced Setup Dial Backup SIEMENS 49 External Modem The following Dial Backup Configuration page is displayed during Dial Backup configuration if you selected External Modem for the connection. To configure the external modem for dial backup: 1. In Backup Failover Timeout, enter the number of minutes that must pass during a WAN link failure before switching to the backup port. This guards against too frequent switching back and forth between the DSL link and the backup port. The default minutes is 3. 2. In Retry DSL Timer, enter the number of minutes that must pass before checking to see if the DSL link ha

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 7 Monitoring Router Diagnostics SIEMENS 84 Diagnostics The Diagnostic feature provides information about various components of your system that might help in diagnosing a problem. To run diagnostics, click Diagnostics on the left navigation pane of the Router Information page. This displays the Run Diagnostics page. From the Run Diagnostics page, you can view information for the following: • PPPoE session • Interface information • ATM statistics • Routing Table information • Files information • Memory usage • List all co

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 6 Security Setup IKE/IPSec Configuration SIEMENS 76 IKE IPSec Proposals Definition IKE IPSec Proposals specify how packets will be encrypted/authenticated for the final SA. To define a new IKE IPSec proposal: 1. Click Create next to IKE IPSec Proposals from the Advanced IKE/IPSec Setup page. This displays the IKE IPSec Proposal Definition page. 2. In IPSec Proposal Name, enter the logical name for the IKE IPSec Proposal Definition. This n

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 3 Easy Setup Select Protocol SIEMENS 25 RFC 1483 If you selected RFC 1483 from the Wan Interface page, the RFC 1483 Networking page is displayed when you click Next. To configure RFC 1483: 1. Select one or more of the following RFC 1483 networking options: • Bridging Enabled: Forward all traffic for remote hosts that is not routed to the WAN (non-IP). If bridging is enabled, you can optionally select Only bridge PPPoE traffic. If selected, only PPPoE traffic is bridged; all other traffic is stopped. • IP Routing Enabled: Routes

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 1 Product Specifications Front Panel for 5935 SIEMENS 5 Front Panel for 5935 The following table explains the LEDs that appear on the front panel of the Siemens 5935 Business Gateway. Back Panel for 5935 The following table describes the various connections on the back panel of the Siemens 5935 Business Gateway. Light Color Indications Power Green Off Power is ON Power is OFF Test Yellow: Yellow flashing: Green: (2 sec blink) Off: Running Power On Self Test Self Test Failure Self Test successful (heartbeat) Router is shut down WAN Yellow: Yellow

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 1 Product Specifications Hardware Specifications for 5930 SIEMENS 2 Hardware Specifications for 5930 Physical Specifications • Dimensions: – 11.75W x 6D x 2.25H inches – 29.8W x 15.2D x 5.7H cm • Weight: –1.5 lbs. – .68 Kg. Operational Environment • Temperature:40°F to 105°F • 5°C to 40°C • Humidity:20% to 80% non-condensing Power Requirements • AC Voltage:100 to 120V AC or 220 to 240V AC • Frequency:50/60 Hz • Consumption:10W maximum Processor • Motorola ® MPC855T • 8 MB DRAM, 4 MB Flash Memory • Mot

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 1 Product Specifications Software Specifications for 5935 SIEMENS 8 IP Address Translation • Network renumbering (RFC 1631) • Network Address Translation (NAT/PAT) • LAN servers supported with NAT • Support for NAT inside an IPSec tunnel Protocol Conformance Testing • RFC 1483 (Bay Networks™, Cabletron™, Cisco™, RedBack™) • PPP over ATM (Cisco, Escalate™, RedBack) (RFC 2364) PPP (RFC 1661) • Data compression of up to 4:1 (STA

  • Siemens 5935, SIEMENS 5930/5935 Business Gateway User’s Guide Chapter 3 Easy Setup Select Protocol SIEMENS 23 Point-to-Point Protocol over Ethernet over PPPoA If you selected Point-to-Point Protocol over Ethernet over PPPoA from the Wan Interface page, the Point- to-Point Protocol over Ethernet over PPPoA page is displayed when you click Next. To configure Point-to-Point Protocol over Ethernet over PPPoA: 1. Enter PPPoE User Name and Password to use for authentication when establishing a WAN connection using PPPoE protocol. 2. In Service Name, enter th

  • Siemens 5935, SIEMENS 81 Chapter 7 Monitoring Router This chapter describes how to monitor the health of your router connections. Router health can be monitored using the following functions. System Summary To view system summary information, click System Summary on the left navigation pane of the Router Information page. This displays the System Summary page. From the System Summary page, you can view information for the following: • Ethernet interface • Remote connections • IP Routing • System System Summary View status and statistical information. Diagnostics Run diagnostic programs t

Related Products and Documents (Gateway):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 White 1740 Instruction book white/1740-4S4.pdf 20 Oct 2023 41 2.89 Mb
2 Hoover SteamVacuum Owner's manual hoover/steamvacuum-ZA3.pdf 05 Nov 2022 16 1.42 Mb
3 Asus G51VX Operation & user’s manual asus/g51vx-386.pdf 26 Apr 2023 30 2.03 Mb
4 Bel Canto PRe6 Operation & user’s manual bel-canto/pre6-IYC.pdf 14 Dec 2023 16 0.52 Mb
5 TerraTec EWS 64 XXL Product information terratec/ews-64-xxl-X4T.pdf 21 Sep 2023 2 0.08 Mb
6 Minolta Magicolor 2300 DL Reference manual minolta/magicolor-2300-dl-BEI.pdf 19 Mar 2024 64

Similar Resources:

  • Dell

    Dimension 4600

    (28 pages)
    www.dell.com | support.dell.com0C1553A01 CAUTION: A CAUTION indicates a potential for property damage, personal injury, or death.Removing the Back Fan Assembly CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your System Information Guide for complete information abo …
  • NI

    C Series

    (40 pages)
    USER GUIDE AND SPECIFICATIONSNI 9795 WSN C Series GatewayThis user guide describes how to use the NI 9795 Wireless Sensor Network gateway and lists specifications. The NI 9795 combines with NI WSN-32xx nodes to form a wireless sensor network. Figure 1. NI 9795 WSN Gateway …
  • Sangoma

    Europa Vega 50 BRI and Elastix

    (16 pages)
    http://www.elastix.orgSangoma Europa Vega 50 BRIand Elastix ServerSetup Guidehttp://www.elastix.orgSangoma Europa Vega 50 BRIand Elastix ServerSetup Guidehttp://www.elastix.orgSangoma Europa Vega 50 BRIand Elastix ServerSetup Guide …
  • Arris

    Touchstone TG862

    (2 pages)
    VERSION: 2014.01.31Wi-Fi SETUP ARRIS TG862 CABLE MODEMwww.tkscable.comGETTING STARTED CHECKLIST Your easyConnect Internet and phone service must be activated and fully functional. First setup a standard “wired” connection to assure that everything is working correctly.  Your computer or mobile device must be equipped with a WLAN or Wi-Fi adap …
  • Media5

    Mediatrix 4104

    (2 pages)
    Discover the Power of 5© 2011, Media5 Corporation Product Version 5.0 – Document Revision 07Mediatrix 4104Installation – MGCP/NCSWarning: In the following installation procedures, do not disconnect the Mediatrix 4104 while the LEDs are flashing.Thank you for choosing the Mediatrix 4104. This Quick Start will help you to properly connect all of the cable …
  • Siemens

    SIMATIC TI505

    (66 pages)
                � …

Comments, Questions and Opinions: