ATTACK ELECTRIC 08 User Manual Manual
|
ATTACK ELECTRIC 08, Stamp, signature of the service organization: .................................... Obligatory service inspection after the 1st year of operation Date: ............................. Obligatory service inspection after the 2nd year of operation Stamp, signature of the service organization: ....................................Date: ............................. Data of the customer: (legibly) Name and surname: ........................................................................... Street: ................................................................ ZIP code, town: ..........................
ATTACK ELECTRIC 08, ATTACK, s.r.o. – 08/2016 ATTACK, s.r.o. Dielenská Kružná 5020 038 61 Vrútky Slovak republic Tel: +421 43 4003 103 Fax: +421 43 3241 129 E-mail: [email protected] Web: www.attack.sk Výrobca ATTACK, s.r.o. si vyhradzuje právo technických zmien výrobkov bez predchádzajúceho upo- zornenia. •ATTACK, s.r.o. producer reserves the right to change technical parameters and dimensions of boilers without previous warning. •Der Hersteller ATTACK, s.r.o. behält sich das Recht der technischen Veräderungen an Produkten ohne
ATTACK ELECTRIC 08, 12 Circuit diagram for connection of the boiler EK09K,EK12K, EK 15K to supply electrical net 3x230V/400V Legend: NTC OV -NTC sensor heating water NTC OUT - NTC outside temperature sensor NTC ROOM - NTC room temperature sensor TER - room thermostat 24V FLOOR - underfloor heating nd 2.ST - external input lightening control 2 level st 1.ST - external input lightening control 1 leve l HDO - mass remote controlí GSM - GSM modem HT - emergency thermostat TS - pressure switcher TUV - service utility water
ATTACK ELECTRIC 08, 32 10. Enclosures 10.1 Installation of the room thermostat, see picture 8. Claims If you have functional and face defects on your boiler, please do not repair it by yourselves. Please apply your claim by the company which put your boiler into operation or by guarantee repair companies stated in the list of guarantee place. Apply condition stated in the guarantee list. Your claim is not valid without fulfilled guarantee list. 9. Way of liquidation Solid waste recycling molid board PE
ATTACK ELECTRIC 08, 10 signal of relay lightening in the second level potentional free switcher HDO (mass remote control) signal potentional free switcher signal HDO (mass remote control) activation of “working zero” N breakdown signal of floor overheating potentional free switcher breakdown signal of overheating 230 V breakdown signal of pressure loss 230 V signal of GSM mode Control unit controls: mode relay heating elements mode relay pump mode TUV (sanitary water) three ways valve for TUV 1.7.4 Antifreeze protection of the boiler Antifreeze protection of the boi
ATTACK ELECTRIC 08, 11 Circuit diagram for connection of the boiler EK18K, EK24K to supply electrical net 3x230V/400V 1.8 Circuit diagram Legend: NTC OV - NTC sensor heating water NTC OUT - NTC outside temperature sensor NTC ROOM - NTC room temperature sensor TER - room thermostat 24V FLOOR - underfloor heating nd 2.ST - external input lightening control 2 level st 1.ST - external input lightening control 1 leve l HDO - mass remote controlí GSM - GSM modem HT - emer gency thermostat TS - pressure switcher TUV - service utility water (sanitary water) KM1 - contactor X1, X2 - switchboard HV - main swi
31 dependent on the demand of regulation and the safety traffic and heat systém. The pump has antiblocking function. More detailed information are stated in the chatter No. 1.7.4 “ Protection function of the boiler”. Time running out of the pump make possible to take away heat accumulated in the boiler body in time of switching off
ATTACK ELECTRIC 08, 20 Temperature of heating water for heating will be automatically calculated on the basis of the outdoor temperature according to the curve chosen and change of starting point (parameter P9) without dependency of heating water temperature setting. Steps for setting are described in a chapter “Setting of parameters”. Disconnecting of equitermic regulation is necessary to carry out with the parameter P8 and with decreasing of the equitermic curve number value under the value “1” till the text “NE” is displayed. 2.3.2 Mode TUV
ATTACK ELECTRIC 08, 15 Circuit diagram TUV ZOV (sanitary water, storage water tank) of the boiler EK 24K Legend: NTC OV -NTC sensor heating water NTC OUT - NTC outside temperature sensor NTC ROOM - NTC room temperature sensor TER - room thermostat 24V FLOOR - underfloor heating nd 2.ST - external input lightening control 2 level st 1.ST - external input lightening control 1 leve l HDO -mass remote controlí GSM - GSM modem HT - emer gency thermostat TS - pressure switcher TUV - service utility water (sanitary water) KM1 -contactor X1, X2 - switchboard HV - main switcher Č - pump ZM - earthing bridg
ATTACK ELECTRIC 08, 30 The graph is determined for thermal drop 80/60 °C and there are 3 curves with pressures of system in cold stage 0,5 and 1 and 2 bars. In case that minimal volume requested of the expansion vessel is bigger than 8l, it is necessary to connect an additional expansion vessel into the heating system to have volume of vessels counted bigger than minimal (according to the graph). In both expansion vessels there are necessary to have a same pressure of nitrogen filling. Curves are valid for using of safety valve set on 3 bars. Filling overpressure of exp
ATTACK ELECTRIC 08, 22 max. output according to parameter P35 max. boiler output according to parameter P35 Parameter marking Information/value displayed in English Importance Setting value Factory setting Autorization Min. version of the boiler - HW setting Setting of heating water tempeature, going to "summer" opeation mode under 30 °C (symbol of summer = tap) 30 to 80, step 1 60 User 1 - DHW setting Setting of sanitary (domestic hot water) tempeature, going to switch off mode under 30°C ("-" is lihtening on the display instead of temperature value) 30 to 65, step 1 50 User 2 - Room setting Setting of
5 Mounting of the boiler could be carried out only by authorized company or persons. On the boiler and 100mm before the boiler there is not allowed a placement of things from flammable materials. The boiler mounted on the wall is not able to be moved or placed to another place. Boiler connection is allowed only with nut with flat ring sealing. It is n
25 This parameter could be set only by authorized service technique! Operation of the boiler in HT is possible only on the basis of permission of official electricity network distributor! P23-Selection of maximal output for heating of TUV (sanitary water) with high price tariff (HT), (0 - 22,5 kW). Using this parameter you are able to limit output of the boiler for heating into t
ATTACK ELECTRIC 08, 29 Other bushings PG9, PG7 are for other signals of the room thermostat and the 3-ways valve. 3.4.2 Installation of the room thermostat Connection of the room thermostat is necessary to do with twin core cable with recommended diameter min. Cu 0,5 mm2 and length to 25 m. The cable for the room thermostat is not allowed to be placed in the same way with supply cord or another electric or industrial installation. Minimal separation is 10 cm. The switch board for the room thermostat connection (24V) is placed in the right part of the control unit from the front face, the clamp with marking TER, the room thermostat has clamps
ATTACK ELECTRIC 08, 16 2. Maintenance 2.1 Control panel information display - temperature setting in the reference room change of the requested parameter - change of the requested parameter + - sanitary water temperature setting - information about instantaneous stage - going to mode STAND-BY - parameters enter - selection confirmation i 0 0 C 0 --0 C 0 --0 C ZI 22,5 kW - going from the mode STAND-BY the mode of heating + - Thermomanometer
19 Without the room thermostat connected Regulation is depended on the temperature of boiler water requested by the user and hysteresis set by the parameter P20 in the scale 1 - 10 °C. (This parameter could be set only by authorized service person). Steps for temperature setting of heating water: Set the temperature requested by pushing , on the control panel , on the disp
ATTACK ELECTRIC 08, 14 Circuit diagram for connection of the boiler EK 05K, EK 06K, EK 08K to supply electrical net 1x230V Legend: NTC OV - NTC sensor heating water NTC OUT - NTC outside temperature sensor NTC ROOM - NTC room temperature sensor TER - room thermostat 24V FLOOR - underfloor heating nd 2.ST - external input lightening control 2 level st 1.ST - external input lightening control 1 leve l HDO - mass remote controlí GSM - GSM modem HT - emer gency thermostat TS - pressure switcher TUV - service utility water (sanitary water) KM1 - cont
ATTACK ELECTRIC 08, 24 P8- Equithermic regulation (NO, 1 to 10) this function actives the boiler regulation on the basis of dependency of heating water temperature calculated and outdoor temperature according to an equitermic curve and its movement. NO equitermic regulation is not active Number 1- 10 number selection of a optimal curve for heating system. Description of equitermic regulation see the point 2.3.1 P9- Selection of equitermic curve start-point movement (20 - 30 °C) You set the start-point of the curve, it means that it is possible to increase the temperature till for 10 °C. The
26 For this possibility of remote GSM control of the boiler it is necessary to buy a GSM model! GSM module works only in the nets with standartized GSM protocol. P31-Selection of the user No. 2 responsible for remote GSM communication with the boiler Using this parameter it has to be inserted GSM mobile phone number of the user responsible for remote GSM commu
ATTACK DP25 Boiler Technical manual
DP25 |
Ideal Boilers Logic Combi C Boiler Manual
Logic Combi C |
ATTACK SLX20 Boiler User manual manual
SLX20 |
ATTACK DPX15 Boiler User manual manual
DPX15 |
ATTACK FD20 Boiler User manual manual
FD20 |
HTP T50M Boiler Installation manual
T50M |
ATTACK EKO Boiler User manual manual
EKO |
ATTACK DP STANDARD Boiler User manual manual
DP STANDARD |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Pyle | PHMD3 | Instruction manual | pyle/phmd3-VOW.pdf | 19 Aug 2022 | 15 | |
2 | Thermal Dynamics | A80 CUTMASTER | Operating manual | thermal-dynamics/a80-cutmaster-653.pdf | 10 Oct 2022 | 110 | |
3 | ProForm | 831.293040 | Operation & user’s manual | proform/831-293040-XQ3.pdf | 10 Sep 2022 | 27 | |
4 | Telex | XO-1 | User instructions | telex/xo-1-358.pdf | 29 Jan 2024 | 2 | 0.41 Mb |
5 | Yamaha | NS-P400 | Owner's manual | yamaha/ns-p400-ZB2.pdf | 29 Jan 2023 | 18 | 0.25 Mb |
6 | Cam Spray | 1450SHDE | Operator's manual | cam-spray/1450shde-X48.pdf | 22 Feb 2023 | 13 |
CAC / BDP
OIL FIRED CAST IRONHOT WATER BOILER INSTALLATION, OPERATION & MAINTENANCE MANUALBW4BAH-91 BW4RAH-91BW5BAH-91BW5RAH-91BW4BAH-105BW4RAH-105BW5BAH-105BW5RAH-105BW4BAH-140 BW4RAH-140BW5BAH-140BW5RAH-140BW4BAH-126BW4RAH-126BW5BAH-126BW5RAH-126BW4BAH-175BW5RAH-175BW5BAH-175BW5RAH-175BW4BAH-210BW4RAH-210BW5BAH-210BW5RAH-210Models (Series C)BW4BAH-168BW …
BW4BAH-91(32 pages) |
Beretta
1EXCLUSIVEGREENC.S.I. - R.S.I. eTTTTTelepítői és felepítői és felepítői és felepítői és felepítői és felhasználói kelhasználói kelhasználói kelhasználói kelhasználói kézézézézézikikikikikönönönönönyvyvyvyvyvMagyarManual de instalare si utilizareManual de instalare si utilizareManual de instalare si utilizareManual de instal …
EXCLUSIVE GREEN 25 CSI(100 pages) |
Lochinvar
Service ManualModels: 1.5 - 2.0 - 2.5 - 3.0 - 3.5 This manual must only be used by a qualified heating installer / service technician. Read all instructions, including this manual and the Crest Installation and Operation Manual, before installing. Perform steps in the order given. Failure to comply could result in severe personal injury, death, or substan …
Crest 1.5(56 pages) |
Truma
Boiler50°70°Boiler BS 10/BS 14Truma Gerätetechnik GmbH & Co. KGPostfach 1252D-85637 PutzbrunnServiceTelefon +49 (0)89 4617-142Telefax +49 (0)89 4617-159e-mail: [email protected] per l’uso Pagina 11Da tenere nel veicolo!GebrauchsanweisungSeite 2Im Fahrzeug mitzuführen!Operating instructions Page 5To be kept in the vehicle!Mode d� …
BS 10(28 pages) |
Gabarron
43210 INSTRUCCIONES DE INSTALACIÓN Y USO INSTALLATION INSTRUCTIONS AND USER GUIDE MATTIRA CALDERAS ELÉCTRICAS MODULANTES DIGITALES DIGITAL MODULATING ELECTRIC BOILERS PARA CALEFACCIÓN / FOR CENTRAL HEATING MAS18 MAS15 Por favor, lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez. Estas instruccion …
MATTIRA MAS18(44 pages) |
Baxi
Setting Parameters:The editable parameters are those between 504 and 652. Proceed as follows to accessthese parameters:1. Simultaneously press keys 1 and 4 on the QAA73 controller forapproximately 3 seconds. The message “Initializing BMU parameters”appears on the display.2. Simultaneously press keys 1 and 2 for approximately 3 seconds. Parameter504 will …
LUNA HT 1.650(11 pages) |
Steven Runners Heart Rate Monitor SR-383Steven Runners SR-383 Guide (Owner's manual), @5LNF3L SR-383, 32 |
Planet Switch VC-820M#HF397I VC-820M: Planet Switch Owner Documentation VC-820M, 2 |
DigiDesign Software DigiRack Plug-insDigiDesign DigiRack Plug-ins User Guide (Manual ), @9WNZ73 DigiRack Plug-ins, 143 |
Alcatel Cell Phone Onetouch Pixi3Alcatel Cell Phone Quick start manual (File: alcatel-onetouch-pixi3-quick-start-manual-17, Thursday 04-01-2024) Onetouch Pixi3, 17 |
3Com Switch IntelliJack NJ200#LC6945: IntelliJack NJ200 Switch Operation & user’s manual IntelliJack NJ200, 58 |
Vaillant Boiler ecoTEC plus 612ecoTEC plus 612 Instructions for installation and servicing - 35JZ2A ecoTEC plus 612, 184 |
Belkin Adapter G+Belkin Product Manual: G+ PDF Operation & user’s manual - 9KS5Q3 G+, 228 |
Proficient Protege Speakers C851Proficient Protege Speakers Owner's manual (File: proficient-protege-c501-speakers-4, Friday 08-09-2023) C851, 4 |
Cooper Lighting Indoor Furnishing Fenestra 174Fenestra 174 Specification sheet - 473241 Fenestra 174, 1 |
Lenovo Laptop T40Laptop #AUZH35 T40, 8 |
Cuisinart Oven RTO-20Oven PDF Instruction and recipe booklet RTO-20, 21 |
NETGEAR Network Router GS108P-100NASNETGEAR GS108P-100NAS Network Router Installation manual GS108P-100NAS, 2 |