  • Casa Med Classic FS 14 Issued: 25.07.2007 NURSING BEDS Patient pole Patient pole 1 x patient pole with strap and handhold only for nursing beds with Trendelenburg’s position: 1 x rechargeable battery (Accumulator box) with metal support and fixing screw Accumulator box Extent of delivery Hand setDepending on nursing bed version: 1 x (5) Hand set, without pushbutton for Tr

  • Days Casa Med Classic FS, Casa Med Classic FS 54 Issued: 25.07.2007 NURSING BEDS Testing plan 12.3 Testing intervals Testing intervals are dependant on the type of usage for Days Healthcare nursing beds. • Days Healthcare prescribes testing intervals of two years for safety inspections in accordance with MPBetriebV (Germany) under normal environmental and operating conditions. • If being brought back into use, inspections should take place before every new usage (after being assembled at the patient’s location) and then every two years. • Testing i

  • Days Casa Med Classic FS, Casa Med Classic FS 45 Issued: 25.07.2007 NURSING BEDS 4 a Insert the socket spanner Key functions bedframe head and foot section head section foot section Trendelenburg´s position „Programme setting“ hand set Operation 9.4.6 Programming the function keys During programming, the key rows can be individually blocked / enabled for operation. The locking settings of the function keys are shown by the LED´s (2) at the hand set. LED on = function key enabled LED off = function key locked To program: ➨ Insert socket spanner in rotary knob. ➨ Turn the rotary knob markin

  • Casa Med Classic FS 19 Issued: 25.07.2007 NURSING BEDS 2,06 m 1,01 m 7.1 Location selection and space requirements Accident hazard! • Only carry out assembly work using suitable tools. • Only carry out assembly work if you are used to working with the tools required. When selecting the bed’s location, ensure that: • there is enough space to nurse the patient in the

  • Days Casa Med Classic FS, Casa Med Classic FS 31 Issued: 25.07.2007 NURSING BEDS 7.14 Installing the patient pole Insert the patient pole (1) in the attachment (2) fixed to the bedframe at the required bed side. ➨ Installing the patient pole NOTE: The guide groove at the end of the patient pole tube (1) must be located over the pins in the attachment (2). Push the handgrip strap loop (3) onto the patient pole tube. ➨ Bed rails on foot end Setting up the nursing bed Fixing the bed rail at the foot end: ➨ Press the plasti

  • Days Casa Med Classic FS, Casa Med Classic FS 62 Issued: 25.07.2007 NURSING BEDS Storage Pull both quick-release bolts (8 + 9) out of the receptacle and remove mattress support motor (10). ➨ Remove the accumulator box from the nursing bed (only nursing beds with Trendelenburg’s position). ➨ Remove mattress support motor Remove accumulator box Disconnect the plugsUnlock the tension relief by pressing in the side clamps (7) and remove. Disconnect the following electrical component plugs from the control unit: 2 = Hand set 4 = mattress support motor for foot section adjustment 5 = Cable for lift motor; foot se

  • Days Casa Med Classic FS, Casa Med Classic FS 11 Issued: 25.07.2007 NURSING BEDS Hazards due to electrical and mechanical faults! • Always remove faulty nursing beds from operation and secure them against unauthorised use (remove mains plug). • Only use original spare parts supplied by Days Healthcare. • Always carry out the prescribed maintenance work at the intervals stated. • Do not carry out any alterations to the electrical or mechanical fittings supplied with the bed unless authorised to do so by the manufacturer. Any manufacturer’s guarantee liability

  • Days Casa Med Classic FS, Casa Med Classic FS 50 Issued: 25.07.2007 NURSING BEDS Engage all wheel brakes (a).➨ Opening the transport safety device After moving: Operation Remove the mains plug from the safety strap. To open the safety device, press the side tabs (2) on the locking device and pull back the lock. Plug the mains plug into the socket (see information in chapter 9.2). ➨ ➨ 9.9 Adjusting the slatted frame springiness The springiness for the individual slats can be adjusted using the six bars (1) fixed to the centre of the slatted frame. This enables the slatted frame to be adjusted to

  • Days Casa Med Classic FS, Casa Med Classic FS 15 Issued: 25.07.2007 NURSING BEDS Assembling the nursing beds 5.1 Bed rails The bed rails (1) are fixed to the head end and foot end on the bed using plastic sliders. Both the upper lock for lowering and the lower lock for removing the bed rails can be unlocked using the fastening knob (2). 5.0 Fittings: bed frame bed rails Bed rails Hand set Patient pole Bed rails Mattress support 4.0 Components Bed end (head section) Bed end (foot section)

  • Days Casa Med Classic FS, Casa Med Classic FS 9 Issued: 25.07.2007 NURSING BEDS Possible danger through altering patient’s position! • Always lock all hand set adjustment functions on the hand set which could cause danger to the patient’s health if adjusted (consult doctor). • Always take into account the patient’s condition before locking the adjustment options Safety information 1.5 Notes for nursing personnel, attendants and operator Accident hazard! • Do not use electrical medical appliances on patients in these nursing beds. • Do not use the nursing bed in the vicinity

  • Days Casa Med Classic FS, Casa Med Classic FS 3 Issued: 25.07.2007 NURSING BEDS All Days Healthcare nursing beds are manufactured using the most modern technical facilities to ensure the highest lying and operating comfort possible. Furthermore, the construction has been designed placing great value on simple handling and operation. The nursing beds described in this manual are constructed to the following standards: DIN EN 1970 - 2000 (standard for nursing beds) and DIN EN 60601-2-38 (standard for hospital beds) in addition. Since the nursing bed motor system has a control system with a clo

  • Days Casa Med Classic FS, Casa Med Classic FS 64 Issued: 25.07.2007 NURSING BEDS 14.2 Placing the components in the transport and storage system (TLSU) Storage Fix the bed ends to the TLSU as follows: (1.) Push the TLSU (1) onto the bed end guides. ➨ Fix the connection by tightening the clamping screws (2). ➨ Push the mattress support head section (4) onto the TLSU guides and secure by tightening the hand levers. ➨ Push the mattress support foot section (3) into the TLSU guides and secure by tightening the hand levers. ➨ Push the patient pole into the TLSU mounting (6). ➨ NOTE: The mountings (a) with the clamping screws must be pointing in th

  • Days Casa Med Classic FS, Casa Med Classic FS 26 Issued: 25.07.2007 NURSING BEDS Setting up the nursing bed Open the quick-release bolt retainer (1).➨ Insertion direction = The mattress support motor with the motor housing (2) is fixed under the mattress support pointing towards the head end (observe label on nursing bed). 7.8 Inserting the mattress support motor for foot section adjustment Foot Pass the receptacle of the motor side (2) between the mattress support frame tabs (3). Insert the quick-release bolt (4) and secure by closing the retainer. Pass the second receptacle (5) between the foot end adjustment frame tabs (6). Insert the quick-release bolt (7) and secure by closing the retainer. �

  • Casa Med Classic FS 67 Issued: 25.07.2007 NURSING BEDS Nameplates 16.2 Specifications: Drive system Power supply _ 230 VAC 50 Hz Safety class _____________ II Ingress protection______ IP44 Noise level ______ < 65 dB(A) Maximum continuous operation _________ 2 minutes Minimum pause after operation ____ 18 minutes Lift - lying area motor Head section _______

  • Days Casa Med Classic FS, Casa Med Classic FS 55 Issued: 25.07.2007 NURSING BEDS Description Visible inspection of all frames and housing parts for deformation, damage, wear and corrosion: Mattress support and its plastic elements ❐❐ Bedframe side panels ❐❐ Bedframe head and foot ❐❐ Backrest adjustment guides ❐❐ Bed rails ❐❐ All lifting device components ❐❐ Track rollers ❐❐ Check all connecting elements (e.g. nuts, bolts, ❐❐ rivets..) for completeness, function and correct seating. all casings ❐❐ existing casing seals ❐❐ casing bolt seating ❐❐ patient pole attachment ❐❐ all patient pole components ❐❐ Assessment OK defective

  • Days Casa Med Classic FS, Casa Med Classic FS 37 Issued: 25.07.2007 NURSING BEDS 9.3 Raising or lowering the bed rails Lowering the bed rails: Raising the bed rails: Lowering the bed rails Pull the bed rails up until the top fastening knob (1) engages. ➨ Raise the bed rail slightly. Press the fastening knob (1) in and lower the bed rail. ➨ ➨ Caution! Do not allow bed rails to fall unsecured onto the bottom locking clip! • When lowering the bed rail, use your other hand to lower it as far as the locking clip. Always place the head and foot end of the siderail in the same posi

  • Days Casa Med Classic FS, Casa Med Classic FS 23 Issued: 25.07.2007 NURSING BEDS Setting up the nursing bed Plug arrangement Insert tension protection Plug the electrical component plugs into the jack sockets as shown in the following diagram. The labels on the plug arrangement shown in the photo correspond to those on the control unit. Plug arrangement: 1 = Not in use 2 = Hand set 3 = Mattress support motor (pre-fitted on the control unit) 4 = mattress support motor for foot section adjustment 5 = Cable for lift motor; foot section 6 = Cable for lift motor; head section 7 = Accumulator box (only nursing beds with Trendelenburg’s position) ➨ *NOTE Jack sockets not in use must be closed using dummy

  • Days Casa Med Classic FS, Casa Med Classic FS 61 Issued: 25.07.2007 NURSING BEDS Pull both quick-release bolts (4 + 5) out of the receptacle and remove mattress support motor (6) complete with control unit. ➨ Remove the hand set cable from the tension protection (3) on the bed frames. ➨ Loosen the anti-kink and tension protectors (2) for the mains cable from the bed frames (spanner size 19 mm). ➨ Storage Remove mains cable Remove hand set cable Remove mattress support motor with control unit

Related Products and Documents (Indoor Furnishing):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Celestron NexStar 6SE Instruction manual celestron/nexstar-6se-V6W.pdf 28 Jan 2023 52 3.56 Mb
2 Logitech 967300-0403 - Cordless MX Duo Installation manual logitech/967300-0403-cordless-mx-duo-DG8.pdf 26 Jul 2022 2
3 Holland Grill BH421-SS-2 Instruction manual holland-grill/bh421-ss-2-ZU4.pdf 02 Nov 2023 12
4 Husqvarna 325P5X-series Operator's manual husqvarna/325p5x-series-33D.pdf 22 Dec 2023 32
5 Lumex FREEDOM 80500 Operation & user’s manual lumex/freedom-80500-3ST.pdf 02 Aug 2022 2
6 Silvercrest Z30342 Operation and safety notes silvercrest/z30342-HVT.pdf 12 Dec 2023 21

Similar Resources:

  • Cooper Lighting

    QCM504RMMH

    (1 pages)
    DESCRIPTIONCatalog # TypeProjectComments DatePrepared bySPECIFICATION FEATURESwww.cooperlighting.com12.00”9.48”5.20”12.00”Up to 1-3/8”CeilingCut-Out7.10”dia.A ...HousingConstructed of 18 gauge CRS with flat black powder coated internal finish.Adjustable trimless mesh plate and swing-out retaining brackets can accommodate up to 1-3/8” ceiling …
  • Enwork

    PROXI

    (8 pages)
    Programmable Remote Control Model – Rev 1Model of Applicable Control Unit: M1.1/M2.1/M2.2/M1.3/M2.3Compatible with Solano VT & Solano VT2Revised 09/19PROXI PROGRAMMABLE REMOTE CONTROL USER GUIDEHEIGHT ADJUSTABLE TABLETI0041 …
  • Gunnebo

    GlasStile GSR

    (42 pages)
    ............................. CCEC/ OM Manual GlasStile GSR 1.6 EN 07.2009 GlasStile GSR Installation Operation and Maintenance Manual …
  • Madison Park

    Driscoll 2-Door Cabinet

    (2 pages)
    Assembly Procedures:Pre-assembly:Remove all parts and hardware from box along with any plastic protective packaging.Do not discard any contents until after assembly is complete to avoid accidentally discarding small parts orhardware.Important safety instructions:Please carefully read all instructions before assembling the chest.For your safety and ease, asse …
  • Cooper Lighting

    1487

    (1 pages)
    14871487COOPER LIGHTINGFAIL-SAFE®CLEANROOMDIMENSIONS• Lens is clear extrudedwith prisms positionedinside fixture and smoothsurface on the outside foreasy cleaning• Flush mounted, stainlesssteel machine screws• Nominal 5” deeprecessed one-piece 20 ga.CRS housing• Unique, Particulock™lens retention system.Lens is hermeticallysealed to door frame� …
  • Next

    OHARA 330678

    (15 pages)
    330678330678-2019-V1.OHARA 6 TO 8 EXTENDING DINING TABLEActual product sizeAssembly instructionsIMPORTANT - RETAIN FOR FUTURE REFERENCEProduced in China for Next Retail Ltd. Need Help ?With: Assembly instructionMissing or damaged parts CALL: 0333 777 8999H75 x W160 x D90cmH75 x W200 x D90cm …

Comments, Questions and Opinions: