  • Siemens Advance Network Gateway, ii •• Table of Contents 2000590-001 Table of Contents, Continued Parts Catalog 57 Introduction 57 Available Parts 58 Power Supply Assembly Removal 59 Data Hiway Testing 61 Definitions of Important Terms 63 Chapter 5: Appendix Glossary

  • Siemens Advance Network Gateway, 2000590-001 Installation •• 17 Wiring Connections All input ac power and communications connections are made to con- nectors located on the chassis power supply assembly. To gain access to the assembly, open the front panel of the ANG_EN. For Zone 1 units refer to the Figure 1-4, Zone 1 Outline Drawing. Advance Data Hiway Port 1& 2 AC Power Power ON/OFF Switch ANCB (Advance Network Communications Board) Ethernet Port Two removable wiring access plates permit all the wiring to be made through the bottom section (wall units

  • Siemens Advance Network Gateway, 2000590-001 Preface •• iii/iv Preface This manual is intended to introduce users to the Advance Network Gateway Ethernet (ANG_EN) unit that uses the ANCB Communications Board P/N 2020951-001. The manual includes complete instructions for proper and safe installation of the ANG_EN by installation personnel. The manual provides the following information: Topic Page Chapter 1. Advance Network Gateway 1 Chapter 2. Installation 9 Chapter 3. Data Communication Setup 25 Chapter 4. Troubleshooting 47 Chapter 5. Parts Catalog 57 Appendix. Data Hiway Testing 61 Glossary 63 Audience & Purpose Chapter Contents

  • Siemens Advance Network Gateway, 2000590-001 Installation •• 23 Ethernet Connections The DataNET Gateway connects to the Ethernet local area network via the RJ-45 STP connector located on the topside of the ANCB. Read the following notes. 1. The 10BASE-T data cable requires a minimum of two twisted pair (transmit pair and a receive pair). Wire used should conform to the AT&T D-inside wire (DWI&PDS), or IBM Type 3 or better twisted-pair cable specifications, or Category 3 or 5 data grade cabling or better. 2. The maximum length of a 10BASE-T data cable can not exceed 328 feet (100 meters). Typically to increase the distance each ANG_EN will connect to a

  • Siemens Advance Network Gateway, 10 •• Installation 2000590-001 Unpacking & Inspection After opening the carton containing the unit, remove the unit from the carton and inspect it for damage that my have occurred during transportation. Points of inspection are: • Inspect exterior of unit for dents, chipped paint, scratches, etc. • Open unit and visually inspect interior mounted assemblies, con- nectors and printed circuit boards for damage. If there is any damage, notify your local Siemens Applied Automation repre- sentative. Keep all shipping materials as evidence of damage, for carrier’s inspection. Siemens Applied Automation will arrange for immediate repair or repl

  • Siemens Advance Network Gateway, 38 •• Data Communications Setup 2000590-001 Editing the Address Translation Table The Advance Network Gateway (ANG_EN) monitors the “local” ADH bus for messages with a “remote” destination address. The ANG_EN determines if the message destination is “remote” by searching it’s Address Translation Table (ATT). If the destination address is located remotely, the ANG_EN encapsulates the ADH message within the data portion of an IP packet and sends the message out the Ethernet port. The Address Translation Table (ATT) records all known units that reside on the Advance Data Hiway (ADH).

  • 12 •• Installation 2000590-001 Pre Installation Planning, Continued Figure 2-2 illustrates how a ANG_EN can be used to physically extend a sin- gle loop of the Advance Data Hiway (ADH) by providing a conversion from the ADH media to Ethernet, and back to the ADH media. All segments of the system labeled “Advance Data Hiway” are according to standard installation practices (9182 B

  • Siemens Advance Network Gateway, 2000590-001 Installation •• 15 CE Installations This section should be used for installation sites that must conform to CE (Conformite Europeene) Certification. Typically, this does not apply to installations outside the EC unless the equipment was purchased with the explicit requirements and expectations that it shall conform to EC Electromagnetic and Radio Frequency Interference (EMI/RFI) rejection specifications. Available from Siemens Applied Automation CE Installation Kit P/N 2020264-001. This kit has all the parts for all the installations r

  • Siemens Advance Network Gateway, viii •• Safety Practices and Precautions 2000590-001 Safety Practices and Precautions, Continued Before switching on the power, check that the operating voltage listed on the equipment agrees with the available line voltage. Any interruption of the grounding conductor inside or outside the equip- ment or loose connection of the grounding conductor can result in a dan- gerous unit. Intentional interruption of the grounding conductor is not permitted. If it is determined that the equipment cannot

  • Siemens Advance Network Gateway, 2000590-001 Installation •• 19 AC Power (Mains) Connections, Continued Step Action 6. Locate the power-input connector on the power supply as- sembly. Loosen the wire retaining screws on top of con- nector. Strip the insulation ¼ -inch back from each of the power supply leads. Insert each lead in the correct location, and tighten down retaining screws. 7. Locate the ANG_EN chassis ground lug and connect wire from it to the building’s ground connection. 8. Inspect all connections for shorts or loose connections. 9. You are now ready to connect the Data Hiway cable; con- tinue with Data Hiway Connections, page

  • Siemens Advance Network Gateway, 2000590-001 Troubleshooting •• 47 Chapter 4 Troubleshooting Introduction This chapter provides installation personnel with troubleshooting infor- mation to solve problems associated in the setup of the Advance Net- work Gateway. Before beginning the installation process read through this Chapter to familiarize yourself with the information provides. Topic See Page ANCB Description 48 ANCB’s LEDs Description & Operation 49 Ethernet Troubleshooting Guide 52 Guide to Network Health 54 Obtaining Diagnostic Information 55 Ove

  • Siemens Advance Network Gateway, 2000590-001 Data Communications Setup •• 43 Firmware Updates Periodically we will provide our ANG_EN users with firmware upgrades. Perform the following instructions to download a new ANG_EN firmware upgrade to the Communications board. A firmware upgrade will take ap- proximately 5 minutes. The following procedure assumes that the Windows Hyper Terminal pro- gram residing on your PC has been configured, the ANG_EN is opera- tional and the PC is connected to the ANG_EN. 1. Log on to the ANG_EN. 2. At the >> prompt type: download You should see the following response on the screen. At this point the ANG_EN Communications bo

  • Siemens Advance Network Gateway, 2000590-001 Installation •• 21 Data Hiway Connections, Continued For technical information on the Data Hiway refer to Appendix A in the Optichrom Advance Library Set, Volume 2, Board Installation and Strap- ping Manual. Step Action 1. Place the ANG_EN AC Power Supply (Mains) circuit breaker to OFF. On the ANG_EN Power Supply Assembly place toggle ON/OFF switch to OFF. WARNING Placing the Power Supply Assembly toggle ON/OFF switch to OFF does not remove the main voltage to the J1 termi- nals. To remove all input power to the ANG_EN, the AC Power (Mains

  • 2000590-001 Installation •• 9 Chapter 2 Installation Introduction This chapter is intended for installation personnel. After completing the pro- cedures, within this Chapter, the Advance Network Gateway will be ready for operation. Ensure that all AC Power (Mains) Specification requirements and advisories are met. Failure to do so, and operating the equipment

  • Siemens Advance Network Gateway, 2000590-001 Data Communications Setup •• 37 Assigning an IP Address Each Advance Network Gateway (ANG_EN) unit on a network must be assigned an IP address. This 32-bit number defines each ANG_EN’s network ID and host ID. The IP address is assigned by the user before the Gateway is physically connected to a network. See Setting Network Address & Loop and Unit Numbers, for instructions on how to enter the IP address. The IP Address consists of a 32-bit number divided into four 8-bit fields. Each field is expressed as a decimal number from 1 to 255 with each field separated by periods. This is r

  • Siemens Advance Network Gateway, 52 •• Troubleshooting 2000590-001 Ethernet Troubleshooting Guide The most common problems associated with the Ethernet and how to correct them are given in the table below. Fault Probable Cause Collisions Excessive collisions are most often caused by a physical media problem such as: 1. missing or incorrect terminators (10Base2) 2. impedance discontinuities (such as defec- tive connectors, cable stubs, crushed ca- bles, incorrect cable types) 3. defective network interface cards (NIC) 4. too many network devices on a single colli- sion domain Late Collisions Causes of Late Collisions are faulty NIC card or a network that is physically too long. A network

  • Siemens Advance Network Gateway, 2000590-001 Data Communications Setup •• 33 Setting Network Address & Loop and Unit Numbers This section provides instructions to configure an Advance Network Gateway (ANG_EN) with its own Network Address. 1. Open Windows Hyper Terminal program on your PC; reference Con- figuring Your PC, page 26. 2. Connect and Log on to ANG_EN; reference Establishing a Con- nection, page 26. Familiarize yourself with the following definitions. address ip: This is the 12-digit address that defines each ANG_EN’s network ID and host ID. The IP ad- dress must be assigned before the ANG_EN is placed on-line to the network. Typically the cus- tomer’s

  • 54 •• Troubleshooting 2000590-001 Guide to Network Health There are no magic numbers for good, or bad, network parameters (such as: utilization and collisions). The parameters that are acceptable for a healthy network are determined by many variables. 1. Utilization should average less than 40%. If you have extended peaks of greater than 70% you may want t

  • Siemens Advance Network Gateway, 48 •• Troubleshooting 2000590-001 ANCB Description The ANCB (Advance Network Communication Board) is the communica- tions electronics for the unit. The ANCB plugs into to PCI slot located on the power supply assembly. A bracket fastens it to the chassis. See Fig- ure 2-4 Power Supply/ANCB Assembly. J12 J4 10Base2 10BaseT ADH-A J10 DataNET- ADH-B J11 DataNET-B Config Port RS232 57.6 KB Board RESET Operation LEDS J5 J2 (N/A for ANG-EN Operation) Jumpers J10 & J11 select the ANG_EN network interface provided to connector

  • 2000590-001 Advance Network Gateway •• 7 Specifications, Continued P K L M N O c/l S T TOP K 0 P c/l R BOTTOM C Q LEFT G H I J c/l Q RIGHT D A E F FRONT B Figure 1-4 Description Metric (mm) U.S. (inches) A Overall enclosure height 523 20 9/16 B Overall enclosure width 431 16 15/16 C Overall enclosure depth from wall mounting 271 10 11/16 D Vertical distance between wall mo

  • Siemens Advance Network Gateway, 2 •• Advance Network Gateway 2000590-001 Introduction, Continued The Advance Network Ethernet Gateway is available in the following configu- rations: Description SAA Part Number CSA/NRTL, Div 2, ADH to Ethernet, Wall Mount, CE (Copper) 2015840-001 CSA/NRTL, Div 2, ADH to Ethernet, Rack Mount, CE (Copper) 2015838-001 CENELEC, ZONE 1, ADH to Ethernet, Wall Mount, CE (Copper) 2015850-001 Available Configurations

Related Products and Documents (Gateway):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Mio Cyclo series Operation & user’s manual mio/cyclo-series-KS7.pdf 16 Oct 2023 24
2 Vive Comfort TP-N-631 Operation manual vive-comfort/tp-n-631-ABL.pdf 07 Oct 2022 4
3 HP ProLiant SL165z - G6 Server Maintenance and service manual hp/proliant-sl165z-g6-server-7HA.pdf 16 Sep 2023 80 4.37 Mb
4 Minuteman V10 Pro Plus User manual and parts manual minuteman/v10-pro-plus-T57.pdf 02 Jun 2023 20
5 Potterton Performa 24 Eco HE Installation and service instructions manual potterton/performa-24-eco-he-O43.pdf 30 Jul 2023 48
6 SVP DC-12D Specifications svp/dc-12d-PG6.pdf 04 Aug 2023 1

Similar Resources:

  • ICP DAS USA

    SMS-531

    (8 pages)
    SMS-531 Quick Start v1.0 2013/01 1/8 Quick Start Jan. 2013 Version 1.0 Package checklist The package includes the following items:  One SMS-531 hardware module  One GSM Antenna (ANT-421-02)  One RS-232 cable (CA-0910)  One Quick Start  One software utility CD  One screw driver  One Micro SD card Note: If any o …
  • AudioCodes

    Mediant Series

    (48 pages)
    Version 6.8 / 7.0 May 2016 Quick Setup Guide BroadCloud SIP-Trunking Service using AudioCodes Mediant BRI/PRI Gateway BRI/PRI Media Gateways AudioCodes Mediant™ Series …
  • Novell

    ACCESS MANAGER 3.1 SP1 - ADMINISTRATION

    (112 pages)
    Novell®www.novell.comnovdocx (en) 13 May 2009AUTHORIZED DOCUMENTATIONNovell Access Manager 3.1 SP1 Agent GuideAccess Manager3.1 SP 1July 15, 2009 J2EE* Agent Guide …
  • FingerTec

    TA100C

    (2 pages)
    Back Plate4 feet / 1.2 meter(recommended)ResetTCP/IP PORTPOWER PORTUSB PORT..............Step 1Determine the Location and Positioning of the Installation• Avoid installing the terminals in locations that has contact with a strong light source (e.g direct sunlight, spotlight, fluorescent light, etc)• Avoid installing the terminals in locations wi …
  • G-Tek

    BTG-100

    (13 pages)
    1 Table of Contents Introduction……………………………………………………………………..3 Installation……………………………………………………………………....6 Pairing Bluetooth headset with the Gateway……………………………..8 Making a call………………………………………………� …
  • Rotronic

    RMS-GW-868

    (4 pages)
    www.rotronic.comEnglish12.1067.0103ERMS-GW-868/915 Short Instruction Manual1 GENERAL DESCRIPTIONCongratulations on your new RMS gateway. The gateway transmits the data of the wireless data loggers continuously to the RMS software by Ethernet. These short instructions describe the main functions of the device.Please read this short manual and the instruction …

Comments, Questions and Opinions: