  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Installation and Connection MCI series 35 You should always make sure that the wall socket is properly fused and that a protective earth conductor connection is established. Furthermore, the load/s can in general be connected to the UPS with a corre- sponding power cord. Please ensure that the protective earth connection and the relevant protection of the loads are established. If the UPS is connected via a permanent, fixed connection (e.g. MCI 3000 XS), please see the following connection diagram and the connection values listed below. Fig. 5-3 Connection diagr

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Technical Data MCI series 59 Device protection Overload, total discharge, over-charging Measurements W x D x H [mm] 145x400x220 145x400x220 192x460x347 192x460x347 Weight [kg] 13 13 31 31 UPS category VFI-SS-111 Device protection class IP20 Integrated communica- tion RS232, USB (not simultaneously usable) Communication (option) Intelligent interface cards: SNMP, contact interface Standards / Guidelines Safety:

  • MCI 700, 1000, 2000, 3000 VA (XL) Device Description MCI series 28 Load data (UPS output): The output load is displayed as percentage rela- tive to the max. possible power output. The unit in W (watt) or VA is displayed which is predomi- nates at that moment. VA with higher idle power users, W with higher active power. During overload situa

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Device Description MCI series 19 Normal operating mode (INVERTER-MODE) The normal operating mode is characterized here by the typical double conver- sion. The mains power supply is converted into the DC intermediate circuit, which in turn feeds the UPS output via the inverter (DC/AC converter). In this mode, the BYPASS is inactive. Fig. 3-2 Operating mode: Normal operation. Back-up or autonomous mode (BATTERY-MODE) In the event of a temporary mains failure, the inverter feeds directly from the ac- cumulator bank and supplies the UPS-output without interruption this way. The autonomous mode is limited by the capacity o

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Safety Instructions MCI series 12 2. Safety Instructions 2.1 Introduction The UPS is a device that has been produced according to the rules and regula- tions of technology for an uninterruptible power supply. The device is safe when used properly and under consideration of the safety re- quirements and instructions provided in this operating manual. 2.2 Proper Use The UPS and its related components may only be used for purposes in accord- ance with i

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Table of contents MCI series 4 8. Signals, Error Codes and Troubleshooting Measures ........................................ 49 9. Troubleshooting .................................................................................................... 52 10. Service-Hotline....................................................................................................... 52 11. Software ...............................................................................

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Accessories MCI series 63 For additional information about this product and the associated software please contact our sales and service centers. 15.4 Communication adapter, relay card (Z0C/AS400) The relay card is also an intelligent extension card and is used for the direct and floating coupling with external controls and/or machines. This allows for the UPS status to be transmitted to higher-level controls in real time. Fig. 15-4 Relay card AS400 or real-time monitoring of the UPS. The following signals a

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Installation and Connection MCI series 38 Pin Sub-D: Description: Function: 2 TxD Send (output) 3 RxD Receive (input) 5 PE PE 5.3.3 EPO connector (EMERGENCY POWER OFF), dropping of loads The EPO can be used as an external emergency/off function. EPO, emergency/off contact: Use the supplied double-pole plug for this and connect one opener contact to it (e.g. emergency/off button). When the button is activated, the UPS outlet is switched off (dropped). If no emergency/off button or anything similar is being used, the contact must be linked directly at the connector. Lock the conn

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Device Description MCI series 18 3. UPS Device Description This UPS-unit is an ONLINE-UPS according to the double conversion principle. The UPS receives the classification "Class 1 (VFI-SS-111) due to the excellent operating performance pursuant to EN62040-4. Consequently, any appliances connected via the unit can be ideally supplied, regardless of the performance of the primary energy source (mains power supply). Malfunctioning like: mains failure, low voltage on the mains power supply, grid overvoltage, short-term grid

  • MCI 700, 1000, 2000, 3000 VA (XL) Installation and Connection MCI series 31 5. UPS Installation and Connection All thresholds listed in the technical specifications regarding ambient and oper- ating conditions must be met, to ensure proper operation of the UPS. The system may only be installed and connected by trained authorized electri- cians in accordance with

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Error messages MCI series 52 9. Troubleshooting Over the course of time malfunctioning or failures of the UPS, the accumulator bank or their periphery may occur. Should this be the case, please contact our customer service (service hot-line) as soon as possible. When you contact the service center, please provide the following information to ensure swift resolution: – Model number, serial number and configuration of the equipment; – Date on which the issue first occurred and process; – Control panel L

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Error messages MCI series 50 Error messages of the UPS The following list shows the error messages of the individual operating modes of the UPS in a table: Error status: Report number (FAULT): Additional symbols: Internal Bus fault 05 x INVERTER error 06 x Overload at output 07 x Over temperature error 08 x INVERTER short circuit 14 x Internal Bus short circuit 28 x Cause of error and trouble

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Introduction MCI series 5 1. Introduction 1.1 Preface Dear Operator, This manual is required for the operation of the uninterruptible power supply described herein. It should give you support for working responsibly and provide basic infor- mation about the uninterruptible power supply, namely on how it operates, its application and in addition, what you should do in the event of malfunctioning. Furthermore, this operating manual contains instructions for the transport and storage as well as the handling and installation of the uninterruptible power supply. The planning

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Introduction MCI series 7 Text that is marked with WARNING! provides a warning about hazards. If ac- cident prevention measures are not taken, these dangers may result in seri- ous (irreversible) injuries or even death! Text that is marked with CAUTION! provides a warning about hazards. If acci- dent prevention measures are not taken, these dangerous situations can lead to slight or medium reversible injuries. Text that is marked with NOTICE! contains very important instructions for situ- ations that, if acciden

  • MCI 700, 1000, 2000, 3000 VA (XL) Accessories MCI series 62 Fig. 15-1 UPS mode Fig. 15-2 BYPASS mode In this case, maintenance and service tasks of the UPS or the accumulator bank can be performed in a fast and safe manner. On rare occasions, the UPS or its components can also be replaced without in- terruption of the loads. In addition, usi

  • MCI 700, 1000, 2000, 3000 VA (XL) Device Description MCI series 23 MCI 3000 MCI 3000 XL  (1) EPO port;  (7) Load port (UPS output);  (2) USB-port;  (7b) Load port (16 Ampere);  (3) RS232 port;  (8) Fuse(s) load port;  (4) Fan unit (FAN);  (9) Port for external accumulator bank;  (5) Fuse (mains connection); �

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Operation MCI series 47 After starting the UPS it will only switch to ECO mode very slowly (approx. 20 s), as several tests are run internally. Please have patience. Setting the operating mode "BYPASS": ✓ The starting position for the equipment is STANDBY mode! • Press the selection key to reach the selection mode; • Press the selection key again several times until you reach the pa- rameter "BYPASS ENABLE", that parameter should be blinking; • Press the enter key, to co

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Introduction MCI series 8 Specific warning: Warning about dangerous electrical voltage! Warning about proper handling of accumulators! Instruction symbols: Take note of the provided documentation(s) and/or instructions! Disconnect prior to additional work! Environment protection symbols: Identifies instructions for recycling. Identifies components that are subject to the Electronic Scrap Regulation. Identifies components or parts that must be disposed of. Do not discard these with household waste.

  • MCI 700, 1000, 2000, 3000 VA (XL) Safety Instructions MCI series 14 2.6 Positioning Only operate the UPS in well ventilated rooms, within the specified ambient tem- perature range (according to 13 Technical Data). The UPS may not be placed in the vicinity of heat sources. Always take the operating position into account when positioning the device. Main

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Installation and Connection MCI series 33 For this reason, the UPS system should be equipped with an external by-pass, as that allows for the complete system to be replaced without interruption of the load voltage, should it become necessary. For connection details please see the relevant operating manual (external by- pass). You can also find additional information in this manual in chapter 15 Op- tional accessories or please contact our sales and customer service department at EFFEKTA Regeltechnik GmbH. 5.2 Linkup Prior to connecting the equipment, the following ambient conditions have to be

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Operation MCI series 42 Often, a forced switch to autonomous mode is performed on purpose to text the duration of the autonomous period (backup time) or the UPS equipment. 6.1.4 Direct switching to autonomous mode (COLD START) Even if no connection to the mains power supply is established, the UPS can be switched directly into autonomous mode. Follow the following instructions for this process: ✓ Initial state, the equipment is completely turned off, there is no connection to the mains power supply! • Now press the ON button. Always keep the button pressed until the selection is confirmed by an acous- tic

  • Effekta ACX11CIS70000000, MCI 700, 1000, 2000, 3000 VA (XL) Device Description MCI series 24 3.3.2 The port area, back side of the UPS The Figure shows the UPS input (6, mains IEC connector) and an input circuit breaker (5). The connection is labeled as "AC INPUT" and can dif- fer between the individual models. The MCI 3000 XL model even has a permanent connection. The same is true for the input breaker "BREAKER", which consequently shows different values. The U

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lenovo IdeaCentre B520e Hardware maintenance manual lenovo/ideacentre-b520e-6FR.pdf 18 Jul 2022 61
2 MartinLogan Odyssey Operation & user’s manual martinlogan/odyssey-W2D.pdf 01 Jun 2023 28
3 Gianni Industries GS-200 Specification sheet gianni-industries/gs-200-EX7.pdf 16 May 2023 3 0.9 Mb
4 Breville BBL500 User manual manual breville/bbl500-AKS.pdf 27 Mar 2023 19 0.46 Mb
5 EverFocus EHD360 Operation instructions manual everfocus/ehd360-6LP.pdf 04 Dec 2023 7 0.44 Mb
6 MAXDATA PLATINUM User manual all efforts have been made to offer a maxdata/platinum-N83.pdf 30 Sep 2023 64

Similar Resources:

  • Tripp Lite

    SMART1500CRMXL

    (6 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART1500CRMXLSmartPro 1.5kVA Line Interactive Sine Wave UPS, 1440w, Extended-run & SNMPWEBCARD options, 2URack/Tower, USB, Serial, EPO, 120V Highlights1.5kVA / 1500VA / 1440W line interactive UPS, 0.96 power factor120V output, Corrects …
  • Tripp Lite

    SU1000XL

    (18 pages)
    200408112 93-22801111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comOwner’s Manual1111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comImportant Safety Instructions2Quick Installation3Basic Operation5Storage and Service11Specifications12SmartOnline™Intelligent, True …
  • INFOSEC

    X4 RM PLUS Series

    (28 pages)
    600/800/1000/2000/3000 VA User guide _____________________ 2 Notice d’utilisation _____________ 10  _________________ 19 …
  • Dell

    PowerVault DL2000

    (2 pages)
    Dell™ PowerVault™ DL Backup to Disk Appliance Physical Disk Placement for Automatic Disk ConfigurationIf your Dell™ PowerVault™ MD1000 enclosure is shipped with eight SATA physical disks in slots 7 through 14, move the disk in slot 7 to slot 0 before attaching the MD1000 to the Dell PowerVault DL Backup to Disk Appliance. This will allow you to take …
  • CyberPower

    CPS1000EI

    (2 pages)
    CPS1000EI/CPS2000EI User’s Manual K01-C000003-00 IMPORTANT SAFETY INFORMATION (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate th …
  • Tripp Lite

    SU80KX2

    (5 pages)
    SmartOnline 80kVA Modular 3-Phase UPS System,On-line Double-Conversion International UPSMODEL NUMBER: SU80KX2 DescriptionTripp Lite SU80KX2 80kVA SmartOnline Modular 3-Phase Intelligent, True On-Line Double-Conversion UPSSystem provides 100% system availability with N+1 modular architecture and parallel capability. In N+1configurations, SU80KX2 provides 4 …

Comments, Questions and Opinions: