Manualios.com

Barnett Engineering B1277-HSPA Installation & Operation Manual

  • B1277-HSPA Security System
  • maaApXL.Rmywk
  • Installation & Operation Manual
  • PDF / Adobe Acrobat Reader
  • 45

Barnett Engineering B1277-HSPA Manual Online:

4.35, 980 votes
Barnett Engineering B1277-HSPA User Manual
Barnett Engineering B1277-HSPA User Guide
Barnett Engineering B1277-HSPA Online Manual

Text of Barnett Engineering B1277-HSPA User Guide:

  • Barnett Engineering B1277-HSPA, Installation & Operation Manual March 2017 Rev. 4.1 #200, 550 – 71 st Avenue SE Phone: (403) 255-9544 Calgary, Alberta, Canada Fax: (403) 259-2343 T2H 0S6 www.barnettprotalk.com email: [email protected]

  • Barnett Engineering B1277-HSPA, TABLE OF CONTENTS TABLE OF CONTENTS ......................................................................... 3 1. INTRODUCTION ................................................................................ 1 2. BEFORE YOU BEGIN ........................................................................ 2 3. POWER REQUIREMENTS ............................................................... 3 4. INSTALLATION ................................................................................. 4 WIRING

  • Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 19 6** Group Configuration Cv3: "Program Group" Cv3: "Group Count is . . ." You: X** Enter new value (0 or 2 - 4) #** Exit to Main Menu ** Next Setting Cv3: "Group N" Cv3: "Acknowledge Code is . . ." You: X** Enter a new DTMF code ##** Erase #** Exit to Main Menu ** Next setting Cv3: "Interrogate Code is . . ." You: X** Enter a new DTMF code ##** Erase #** Exit to Main Menu

  • Barnett Engineering B1277-HSPA, GLOSSARY PAGE 38 Digital Input – an input type that, when asserted, generates an alarm condition. Dipole Antenna – an RF antenna with a simple structure. The dipole antenna included with the Cv3 is intended for indoor use only and has limited range. Directory – a list of callout instructions that are executed sequentially when an alarm occurs. Each directory line may specify a telephone number to call, a radio transmission with paging tones, a mobile number to send a text message to, or an email address to receive alarm announcements. DTMF – Dual Tone Multiple Frequency; a series of aud

  • Barnett Engineering B1277-HSPA, INSTALLATION PAGE 4 4. INSTALLATION The B1277 Cv3 should be installed in a clean, dry location suitable for electronic equipment. Caution: Power and antenna cables should be connected only after the installation is complete. In order to communicate with neighbouring cellphone towers, you will need to attach an antenna to the Cv3. The air interface for this phone is an SMA connector on the side of case. A dipole antenna was included in the purchase of this product. This antenna is suitable for indoor use only and is limited in its range. P

  • Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 18 You: x** Enter a new value 0 = NO contacts 1 = NC contacts #** Exit to Main Menu ** Next setting Cv3: "Output Scale is . . ." You: x** Enter new value 1 = seconds 2 = minutes #** Exit to I/O Configuration ** Next Setting Cv3: "Output Time is . . ." You: x** Enter new value 1 to 65535 #** Exit to Main Menu ** Next Setting

  • Barnett Engineering B1277-HSPA, POWER REQUIREMENTS PAGE 2 2. BEFORE YOU BEGIN The Cv3 is an alarm reporting unit with an embedded HSPA transceiver. Included with this device are the following: • 16 pin terminal block for wiring sensor inputs • 16 pin terminal block for wiring relay outputs/radio/power • USB cable for PC programming • Programming software CD-ROM • SMA to TNC Antenna Adapter May also include: • Carrier specific SIM Card • Dipole Antenna System Requirements The Cv3 is designed to operate on an HSPA network. In order to operate on a wireless network, you will require an account with a local wireless provider who will provide you with a Mobi

  • PROGRAMMING PAGE 22 9** Cellular Module Status Cv3: "Phone Interrogate" Cv3: "Signal Strength is . . ." 0 to 15; 3=poor, 6=good You: #** Exit to Main Menu. ** Next item. Cv3: "Roaming status is . . ." 0 or 1; 0=Off, 1=On You: #** Exit to Main Menu. ** Exit to Main Menu.

  • Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 24 * ** Query Version Cv3: "Module Number is . . ." You: #** Exit to Main Menu You: ** Next Cv3: "Hardware version is . . ." You: #** Exit to Main Menu You: ** Next Cv3: "Firmware version is . . ." You: #** Exit to Main Menu You: ** Next Cv3: "Options are . . ." You: #** Exit to Main Menu You: ** Exit to Main Menu

  • Barnett Engineering B1277-HSPA, OPERATIONS PAGE 26 7. OPERATIONS This chapter gives a detailed description of exactly how the Cv3 will operate after the start-up programming has been completed. Parameters which may be altered are pointed out, with reference to the appropriate Program Code section. Alarm Sequence When the B1277 detects an alarm condition, it dials the first telephone number stored in the directory. When the telephone call is answered, the B1277 will announce its Site ID, the list of any alarms present, and prompt the user to “Enter Acknowledge Code”. It will repeat this message a

  • Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 15 Cv3: "Report Every . . ." You: X** Enter time between reports 0 + digits = hours (06, 08 or 012 hours) 1 to 7 digits = days (1 = Monday, 2 = Tuesday…) #** Exit to Main Menu ** Next setting Cv3: "Status Report Text Message Number is . . ." You: X** Enter new destination phone number 0** Erase phone number (disabled) #** Exit to Main Menu ** Next setting Cv3: "Status Report Phone Number is . . ." You: X** Enter new phone number 0** Erase phone number (disabled) #** Exit to Main Menu ** Next setting

  • PROGRAMMING PAGE 23 0** Cellphone Programming The B1277 contains a HSPA based module that is pre-configured at the factory except for the assigned Mobile Number. Cv3: "Program Phone" Cv3: "SIM Card Number is . . ." + 19 or 20 digit number You: #** Exit to Main Menu ** Next item. Cv3: "Mobile Number is . . ." + 10 digit pho

  • Barnett Engineering B1277-HSPA, INTRODUCTION PAGE 1 1. INTRODUCTION The ProTalk Cv3, model B1277-HSPA, is a device used to monitor sensors at an unattended site and provide scheduled reports or announce alarm conditions over a cellular network and/or a two-way radio or public address system. It is compatible with many temperature, humidity, and fluid level sensors as well as smoke, fire, intrusion, and other discrete sensors. The device also has four relay outputs that can be operated automatically or manually (by using a remote telephone) for control of external equipment. Configuration of the ProTalk Cv3 can be accomplished using the dedicated PC application. Additionally, limited pro

  • Barnett Engineering B1277-HSPA, WARRANTY STATEMENT PAGE 42 14. WARRANTY STATEMENT Barnett Engineering Ltd. warrants that all equipment supplied shall be free from defects in material or workmanship at the time of delivery. Such warranty shall extend from the time of delivery for a period of one year. Buyer must provide written notice to Barnett Engineering Ltd. within this prescribed warranty period of any defect. If the defect is not the result of improper usage, service, maintenance, or installation and equipment has not been otherwise damaged or modified after delivery, Barnett Engineering Ltd. shall either replace or repair

  • Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 8 5. PROGRAMMING Programming With A PC In order to program your Cv3 using a PC, you will need to install the appropriate programming software. A complimentary copy of our Windows-based software was included in the purchase of the product. Simply insert the disk into your CD/DVD ROM drive, select Software Installation from the CD Menu and follow the InstallShield instructions. Be sure to keep the disk in the drive until your initial programming is complete. Once the installation of the programming software is complete, you will need to co

  • Barnett Engineering B1277-HSPA, INSTALLATION PAGE 7 Wiring Your Outputs Refer to Figure 2 for details of output pinouts. Figure 2 Output Connections The four output relays can be programmed for either manual remote control or to automatically indicate an internal status of the Cv3. Internal statuses available are ‘new alarm present’, ‘any alarm present’, a pulsed output when an acknowledgement is received or as a system alarm. When used for status indicators, specific relays are assigned as follows: • Relay 1 New Alarm • Relay 2 Any Alarm • Relay 3 Acknowledge Received • Relay 4 System Error Two contacts from each relay are brough

  • Barnett Engineering B1277-HSPA, INSTALLATION PAGE 5 Wiring Your Inputs Connections The Cv3 has ten inputs for connection to customer alarm signals. Each input can be independently programmed to accept either a digital or analog signal. Refer to Figure 1 for details of the connector pinouts. Contacts and Other Digital Alarm Inputs When programmed for digital operation, the high (or open) state is provided by a switched internal pullup resistor connected to a +5 volt source. The low state is when the input voltage is below +2 volts. For most applications, this is done by a closure to ground using either a relay contact or an op

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Daewoo KOR-167ES Operating instructions & cook book daewoo/kor-167es-995.pdf 12 Nov 2022 32 0.54 Mb
2 Antec Notebook Cooler 200 Specifications antec/notebook-cooler-200-164.pdf 16 Jan 2023 1 0.17 Mb
3 American DJ Theatrix PRO 48 LED User instructions american-dj/theatrix-pro-48-led-4Q1.pdf 01 Mar 2023 12 1.37 Mb
4 Glyph DV-Project Specification glyph/dv-project-9C3.pdf 31 May 2023 2 0.58 Mb
5 RoyalTek MEB-1315 Operation & user’s manual royaltek/meb-1315-TS6.pdf 08 Sep 2022 24 2.01 Mb
6 CDA HVN93 Manual for installation, use and maintenance cda/hvn93-WBY.pdf 12 Jul 2023 9 0.82 Mb

Similar Resources:

  • LG

    PQNUD1S00

    (25 pages)
    ESPAÑOLESPAÑOLModels: PQNUD1S00LGControlador de funcionesManual de usuario/ instalaciónImportante• Lea completamente este manual de installación antes de instalar el producto.• Las tareas de instalación deben realizarse de acuerdo con la Normativa Eléctrica Nacional y sólo puede llevarlas a cabo personal autorizado.• Conserve este manual de inst …
  • Foscam

    FI8903W

    (5 pages)
    ShenZhen Foscam Intelligent Technology Co., Limited www.foscam.com How to upgrade firmware for MJPG camera Suitable for MJPG camera: FI8903W, FI8904W, FI8905W, FI8907W, FI8908W, FI8909W, FI8910W, FI8916W, FI8918W, FI8919W. Plug in the Ethernet cable to upgrade firmware, not via wireless. Upgrade the system firmware firstly and web UI secondly …
  • United Security Products

    EM-900 WA

    (20 pages)
    EM-900 WA User Manual What’s Inside: • EM-900 WA (with built-in rechargeable battery.) • AC-2P power adaptor • Cradle What’s needed: • 900 MHz spread spectrum transmitters • Sensors (See list in Addendum A) Thank You for Purchasing The EM-900 WA from USP! USP has made every effort to make The EM-900 WA the finest Monitorin …
  • GE Security

    Simon

    (36 pages)
    )*(,QWHUORJL[CODEEMERGENCYHOME CONTROLHOME SECURITYBypassSystemStatusDoors &WindowsMotionSensorsArmDisarm9/05/63/4 7/81/2On OffSensorMotion TimeDoorsLightsChimeAUXTest WeeklyPOLICEFIREUser Guide466-1871 Rev FSeptember 2002Simon® Security SystemPart No:60-875 …
  • Marmitek

    PROGUARD 800 Series

    (24 pages)
    PROGUARD80020180 / 20111101 • PGPR811TM+ KR814TM© ALL RIGHTS RESERVED MARMITEK ®USER MANUAL 2GEBRAUCHSANLEITUNG 5GUIDE UTILISATEUR 8MODO DE EMPLEO 11MANUALE D’ISTRUZIONI 14GEBRUIKSAANWIJZING 17PROGUARD800™SERIESPR811 PANIC REMOTE ANDKR814 KEYFOB REMOTE …
  • Kidde

    Truesense Combo

    (29 pages)
    1TRUSENSE COMBOUser GuideCombination Multi-Criteria Optical Sensor Smoke & Carbon Monoxide Alarm with Voice and Hardwire InterconnectModel 2070-VASCR HARDWIRE INTERCONNECT FRONT LOAD BATTERY BACKUP VOICE ALARMCOMBINATION ALARM P/N: 2566-7201-00 Rev AHelps Reduce CookingNuisance AlarmsUL 217 8th Ed. …

Comments, Questions and Opinions: