Barnett Engineering B1277-HSPA Installation & Operation Manual
|
Barnett Engineering B1277-HSPA, Installation & Operation Manual March 2017 Rev. 4.1 #200, 550 – 71 st Avenue SE Phone: (403) 255-9544 Calgary, Alberta, Canada Fax: (403) 259-2343 T2H 0S6 www.barnettprotalk.com email: [email protected]
Barnett Engineering B1277-HSPA, TABLE OF CONTENTS TABLE OF CONTENTS ......................................................................... 3 1. INTRODUCTION ................................................................................ 1 2. BEFORE YOU BEGIN ........................................................................ 2 3. POWER REQUIREMENTS ............................................................... 3 4. INSTALLATION ................................................................................. 4 WIRING
Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 19 6** Group Configuration Cv3: "Program Group" Cv3: "Group Count is . . ." You: X** Enter new value (0 or 2 - 4) #** Exit to Main Menu ** Next Setting Cv3: "Group N" Cv3: "Acknowledge Code is . . ." You: X** Enter a new DTMF code ##** Erase #** Exit to Main Menu ** Next setting Cv3: "Interrogate Code is . . ." You: X** Enter a new DTMF code ##** Erase #** Exit to Main Menu
Barnett Engineering B1277-HSPA, GLOSSARY PAGE 38 Digital Input – an input type that, when asserted, generates an alarm condition. Dipole Antenna – an RF antenna with a simple structure. The dipole antenna included with the Cv3 is intended for indoor use only and has limited range. Directory – a list of callout instructions that are executed sequentially when an alarm occurs. Each directory line may specify a telephone number to call, a radio transmission with paging tones, a mobile number to send a text message to, or an email address to receive alarm announcements. DTMF – Dual Tone Multiple Frequency; a series of aud
Barnett Engineering B1277-HSPA, INSTALLATION PAGE 4 4. INSTALLATION The B1277 Cv3 should be installed in a clean, dry location suitable for electronic equipment. Caution: Power and antenna cables should be connected only after the installation is complete. In order to communicate with neighbouring cellphone towers, you will need to attach an antenna to the Cv3. The air interface for this phone is an SMA connector on the side of case. A dipole antenna was included in the purchase of this product. This antenna is suitable for indoor use only and is limited in its range. P
Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 18 You: x** Enter a new value 0 = NO contacts 1 = NC contacts #** Exit to Main Menu ** Next setting Cv3: "Output Scale is . . ." You: x** Enter new value 1 = seconds 2 = minutes #** Exit to I/O Configuration ** Next Setting Cv3: "Output Time is . . ." You: x** Enter new value 1 to 65535 #** Exit to Main Menu ** Next Setting
Barnett Engineering B1277-HSPA, POWER REQUIREMENTS PAGE 2 2. BEFORE YOU BEGIN The Cv3 is an alarm reporting unit with an embedded HSPA transceiver. Included with this device are the following: • 16 pin terminal block for wiring sensor inputs • 16 pin terminal block for wiring relay outputs/radio/power • USB cable for PC programming • Programming software CD-ROM • SMA to TNC Antenna Adapter May also include: • Carrier specific SIM Card • Dipole Antenna System Requirements The Cv3 is designed to operate on an HSPA network. In order to operate on a wireless network, you will require an account with a local wireless provider who will provide you with a Mobi
PROGRAMMING PAGE 22 9** Cellular Module Status Cv3: "Phone Interrogate" Cv3: "Signal Strength is . . ." 0 to 15; 3=poor, 6=good You: #** Exit to Main Menu. ** Next item. Cv3: "Roaming status is . . ." 0 or 1; 0=Off, 1=On You: #** Exit to Main Menu. ** Exit to Main Menu.
Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 24 * ** Query Version Cv3: "Module Number is . . ." You: #** Exit to Main Menu You: ** Next Cv3: "Hardware version is . . ." You: #** Exit to Main Menu You: ** Next Cv3: "Firmware version is . . ." You: #** Exit to Main Menu You: ** Next Cv3: "Options are . . ." You: #** Exit to Main Menu You: ** Exit to Main Menu
Barnett Engineering B1277-HSPA, OPERATIONS PAGE 26 7. OPERATIONS This chapter gives a detailed description of exactly how the Cv3 will operate after the start-up programming has been completed. Parameters which may be altered are pointed out, with reference to the appropriate Program Code section. Alarm Sequence When the B1277 detects an alarm condition, it dials the first telephone number stored in the directory. When the telephone call is answered, the B1277 will announce its Site ID, the list of any alarms present, and prompt the user to “Enter Acknowledge Code”. It will repeat this message a
Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 15 Cv3: "Report Every . . ." You: X** Enter time between reports 0 + digits = hours (06, 08 or 012 hours) 1 to 7 digits = days (1 = Monday, 2 = Tuesday…) #** Exit to Main Menu ** Next setting Cv3: "Status Report Text Message Number is . . ." You: X** Enter new destination phone number 0** Erase phone number (disabled) #** Exit to Main Menu ** Next setting Cv3: "Status Report Phone Number is . . ." You: X** Enter new phone number 0** Erase phone number (disabled) #** Exit to Main Menu ** Next setting
PROGRAMMING PAGE 23 0** Cellphone Programming The B1277 contains a HSPA based module that is pre-configured at the factory except for the assigned Mobile Number. Cv3: "Program Phone" Cv3: "SIM Card Number is . . ." + 19 or 20 digit number You: #** Exit to Main Menu ** Next item. Cv3: "Mobile Number is . . ." + 10 digit pho
Barnett Engineering B1277-HSPA, INTRODUCTION PAGE 1 1. INTRODUCTION The ProTalk Cv3, model B1277-HSPA, is a device used to monitor sensors at an unattended site and provide scheduled reports or announce alarm conditions over a cellular network and/or a two-way radio or public address system. It is compatible with many temperature, humidity, and fluid level sensors as well as smoke, fire, intrusion, and other discrete sensors. The device also has four relay outputs that can be operated automatically or manually (by using a remote telephone) for control of external equipment. Configuration of the ProTalk Cv3 can be accomplished using the dedicated PC application. Additionally, limited pro
Barnett Engineering B1277-HSPA, WARRANTY STATEMENT PAGE 42 14. WARRANTY STATEMENT Barnett Engineering Ltd. warrants that all equipment supplied shall be free from defects in material or workmanship at the time of delivery. Such warranty shall extend from the time of delivery for a period of one year. Buyer must provide written notice to Barnett Engineering Ltd. within this prescribed warranty period of any defect. If the defect is not the result of improper usage, service, maintenance, or installation and equipment has not been otherwise damaged or modified after delivery, Barnett Engineering Ltd. shall either replace or repair
Barnett Engineering B1277-HSPA, PROGRAMMING PAGE 8 5. PROGRAMMING Programming With A PC In order to program your Cv3 using a PC, you will need to install the appropriate programming software. A complimentary copy of our Windows-based software was included in the purchase of the product. Simply insert the disk into your CD/DVD ROM drive, select Software Installation from the CD Menu and follow the InstallShield instructions. Be sure to keep the disk in the drive until your initial programming is complete. Once the installation of the programming software is complete, you will need to co
Barnett Engineering B1277-HSPA, INSTALLATION PAGE 7 Wiring Your Outputs Refer to Figure 2 for details of output pinouts. Figure 2 Output Connections The four output relays can be programmed for either manual remote control or to automatically indicate an internal status of the Cv3. Internal statuses available are ‘new alarm present’, ‘any alarm present’, a pulsed output when an acknowledgement is received or as a system alarm. When used for status indicators, specific relays are assigned as follows: • Relay 1 New Alarm • Relay 2 Any Alarm • Relay 3 Acknowledge Received • Relay 4 System Error Two contacts from each relay are brough
Barnett Engineering B1277-HSPA, INSTALLATION PAGE 5 Wiring Your Inputs Connections The Cv3 has ten inputs for connection to customer alarm signals. Each input can be independently programmed to accept either a digital or analog signal. Refer to Figure 1 for details of the connector pinouts. Contacts and Other Digital Alarm Inputs When programmed for digital operation, the high (or open) state is provided by a switched internal pullup resistor connected to a +5 volt source. The low state is when the input voltage is below +2 volts. For most applications, this is done by a closure to ground using either a relay contact or an op
Fortress Technologies S1 Security System Manual
S1 |
AOR AR-STV Security System Operating manual
AR-STV |
Extel WESV 87053 Security System Installation and user manual
WESV 87053 |
YOKOGAWA SL1400 ScopeCorder LITE Security System Operation & user’s manual
SL1400 ScopeCorder LITE |
Barnett Engineering ProTalk Cv3 Security System Installation instructions manual
ProTalk Cv3 |
Barnett Engineering PRO TALK CV2 Security System Instruction manual
PRO TALK CV2 |
Fluke LinkSprinter 100 Security System Getting started manual
LinkSprinter 100 |
Hach orbisphere C1100 Security System Operation & user’s manual
orbisphere C1100 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Daewoo | KOR-167ES | Operating instructions & cook book | daewoo/kor-167es-995.pdf | 12 Nov 2022 | 32 | 0.54 Mb |
2 | Antec | Notebook Cooler 200 | Specifications | antec/notebook-cooler-200-164.pdf | 16 Jan 2023 | 1 | 0.17 Mb |
3 | American DJ | Theatrix PRO 48 LED | User instructions | american-dj/theatrix-pro-48-led-4Q1.pdf | 01 Mar 2023 | 12 | 1.37 Mb |
4 | Glyph | DV-Project | Specification | glyph/dv-project-9C3.pdf | 31 May 2023 | 2 | 0.58 Mb |
5 | RoyalTek | MEB-1315 | Operation & user’s manual | royaltek/meb-1315-TS6.pdf | 08 Sep 2022 | 24 | 2.01 Mb |
6 | CDA | HVN93 | Manual for installation, use and maintenance | cda/hvn93-WBY.pdf | 12 Jul 2023 | 9 | 0.82 Mb |
LG
ESPAÑOLESPAÑOLModels: PQNUD1S00LGControlador de funcionesManual de usuario/ instalaciónImportante• Lea completamente este manual de installación antes de instalar el producto.• Las tareas de instalación deben realizarse de acuerdo con la Normativa Eléctrica Nacional y sólo puede llevarlas a cabo personal autorizado.• Conserve este manual de inst …
PQNUD1S00(25 pages) |
Foscam
ShenZhen Foscam Intelligent Technology Co., Limited www.foscam.com How to upgrade firmware for MJPG camera Suitable for MJPG camera: FI8903W, FI8904W, FI8905W, FI8907W, FI8908W, FI8909W, FI8910W, FI8916W, FI8918W, FI8919W. Plug in the Ethernet cable to upgrade firmware, not via wireless. Upgrade the system firmware firstly and web UI secondly …
FI8903W(5 pages) |
United Security Products
EM-900 WA User Manual What’s Inside: • EM-900 WA (with built-in rechargeable battery.) • AC-2P power adaptor • Cradle What’s needed: • 900 MHz spread spectrum transmitters • Sensors (See list in Addendum A) Thank You for Purchasing The EM-900 WA from USP! USP has made every effort to make The EM-900 WA the finest Monitorin …
EM-900 WA(20 pages) |
GE Security
)*(,QWHUORJL[CODEEMERGENCYHOME CONTROLHOME SECURITYBypassSystemStatusDoors &WindowsMotionSensorsArmDisarm9/05/63/4 7/81/2On OffSensorMotion TimeDoorsLightsChimeAUXTest WeeklyPOLICEFIREUser Guide466-1871 Rev FSeptember 2002Simon® Security SystemPart No:60-875
…
Simon(36 pages) |
Marmitek
PROGUARD80020180 / 20111101 • PGPR811TM+ KR814TM© ALL RIGHTS RESERVED MARMITEK ®USER MANUAL 2GEBRAUCHSANLEITUNG 5GUIDE UTILISATEUR 8MODO DE EMPLEO 11MANUALE D’ISTRUZIONI 14GEBRUIKSAANWIJZING 17PROGUARD800™SERIESPR811 PANIC REMOTE ANDKR814 KEYFOB REMOTE
…
PROGUARD 800 Series(24 pages) |
Kidde
1TRUSENSE COMBOUser GuideCombination Multi-Criteria Optical Sensor Smoke & Carbon Monoxide Alarm with Voice and Hardwire InterconnectModel 2070-VASCR HARDWIRE INTERCONNECT FRONT LOAD BATTERY BACKUP VOICE ALARMCOMBINATION ALARM P/N: 2566-7201-00 Rev AHelps Reduce CookingNuisance AlarmsUL 217 8th Ed.
…
Truesense Combo(29 pages) |
Sony Cassette Player WALKMAN WM-GX808#3EJ1C3: WALKMAN WM-GX808 Cassette Player Operating instructions WALKMAN WM-GX808, 2 |
VDO Car Receiver TR712UB-BU#9P6V1S TR712UB-BU: VDO Car Receiver Owner Documentation TR712UB-BU, 20 |
AT&T Headsets Mirage CIB 3144AT&T Headsets Mirage CIB 3144 Instruction manual Mirage CIB 3144, 6 |
Applied Energy Battery Charger WorkHorse Series 1Guide: Applied Energy WorkHorse Series 1 (3H3Y68, Upd.20th Feb 2024) WorkHorse Series 1, 6 |
Eiki Projector AH-55001#646BGR AH-55001: Eiki Projector Owner Documentation AH-55001, 2 |
Fujitsu Server Primergy RX300 S3User Manual: Fujitsu Primergy RX300 S3 (BSC6K8, Upd.Wednesday 31-01-2024) Primergy RX300 S3, 113 |
Toyota Automobile Corolla 2002Owner's manual for Toyota Corolla 2002 Automobile Corolla 2002, 253 |
Antelope TV Converter Box Zodiac GoldZodiac Gold (TV Converter Box ePDF Guide, #7KDB72) Zodiac Gold, 15 |
Tripp Lite Network Cable N308-05MTripp Lite Product User Manual: N308-05M PDF Specification sheet - PDYNQ4 N308-05M, 2 |
Z-Com Network Router ZMAX-8210-ENetwork Router PDF Operation & user’s manual ZMAX-8210-E, 49 |
Merlin Gate Opener G900Installation instructions for Merlin G900 Gate Opener G900, 2 |
CompuLab Desktop FIT-PC4CompuLab Desktop Owner's manual (File: compulab-fit-pc4-owner-s-manual-9, 05/01/2024) FIT-PC4, 9 |