Manualios.com

Baer UniMod GSM-3 Operation Manual

Baer UniMod GSM-3 Manual Online:

3.35, 2080 votes
Baer UniMod GSM-3 User Manual
Baer UniMod GSM-3 User Guide
Baer UniMod GSM-3 Online Manual

Text of Baer UniMod GSM-3 User Guide:

  • E122001606063 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH Rathsbergstraße 23 D-90411 Nürnberg Germany Phone +49 911 970590 Fax +49 911 9705950 Internet: www.baer-gmbh.com

  • Baer UniMod GSM-3, Page 2 of 12 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 Contents Page 1. Requirements.................................................................................................. 3 2. Safety Precautions for the User..................................................................... 3 3. Power Supply Unit .......................................................................................... 3 4. Interfaces..........

  • Baer UniMod GSM-3, UniMod GSM-3 Operation Manual Page 3 of 12 Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 UniMod GSM-3 The world-wide GSM radio networks (GSM = Global System for Mobile communication) provide be- sides digital voice communication the possibility to transmit data. In that operation mode is it possible to send fax, data (CSD: Circuit Switched Data connection), GPRS: General Packet Radio Service) and short messages (SMS). The universal radio modem UniMod GSM-3 is supposed for remote inquiry of measurement data of any kind, especially however for

  • Baer UniMod GSM-3, Page 4 of 12 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 4. Interfaces Communication is possible with many standard protocols, like SCTM, LSV1, DLMS, IEC1107, IEC60870 (transparent reading) etc. The interface for connecting the target device can be specified by plugging the appropriate interface module. The following module types are available now: • CS (20 mA current loop) interface module, active (supplies current for 4 devices max.) or passive • RS232 interface module (uses signals RxD, TxD, CTS, RTS, GND, DTR, DCD/DSR) • RS485 interface module •

  • Baer UniMod GSM-3, UniMod GSM-3 Operation Manual Page 5 of 12 Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 7. Programming the Modem Before installing the modem it has to be programmed in order to meet the demands. The baud rate and data format for connecting the target device and the transmission mode and transmission rates must be adjusted. On delivery the following default parameters are active: Data rate 9600 Bit/sec (if not differen

  • Baer UniMod GSM-3, Page 6 of 12 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 Alternative: parametering adapter with 9 pole plug (standard RS232). Now you have to set your terminal program to the fixed, local data rate and data format of the UniMod. (Default values: 9600 Bit/sec, 7,E,1) Use one of the AT commands (e.g. ATS0?, ATI, AT&V) in order to check whether the modem answers. If you see the answer on the screen, the interface is working correctly. Note: Simply typing „AT“ does not result in an answer, beca

  • Baer UniMod GSM-3, UniMod GSM-3 Operation Manual Page 7 of 12 Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 AT+CPIN? code OK SIM card inquiry (code = ERROR: no/faulty SIM card code = +CPIN: SIM PIN: waiting for PIN code = +CPIN: READY: PIN active) AT+CPIN="n" OK Enter PIN, switches modem active. e.g. AT+CPIN="1234" (if PIN is 1234) AT+CLCK= "SC",0,"n" OK Disable PIN lock after power off. (n = PIN) e.g. AT+

  • Baer UniMod GSM-3, Page 8 of 12 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 Example: • Establish connection PC to modem (e.g. using the parametering adapter) • Insert SIM card • Switch on UniMod GSM-3, wait 15 to 30 sec: till first LED is on • Start the UniModSet software • Read the equipment configuration • Adjust the parameter • Write the configuration • Check the signal quality: possible only by CSD-Mode Testing the connection For easier diagnosis of connection problems it is possible to display extended result codes for incom-

  • Baer UniMod GSM-3, UniMod GSM-3 Operation Manual Page 9 of 12 Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 Unusual reaction using "7" data bits and "Even Parity" during data retrieval. Depending on certain circumstances (software configuration, hardware configuration of the PC, con- nection of the modem to the PC, operating system,...) the communication software of your application might issue a message like: wrong parity. In the most cases a switch of

  • Baer UniMod GSM-3, Page 10 of 12 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 10. SMS Optional it is possible to activate SMS. This function is monitoring of on/off state changes of DTR input (terminal 8 and 9): Standard RS232: Function DCD/DTR SMS: Function UA/UE Example: 20mA interface with two meters and SMS input (contact): 1 1098765432 UniMod GSM-3 Interface: 20mA Baudrate: 9600 7e1 GSM 85 - 26

  • Baer UniMod GSM-3, UniMod GSM-3 Operation Manual Page 11 of 12 Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 11. Technical Data Housing: Wall-mounted housing Degree of protection: IP52 (IEC) Dimensions: W = 105 mm, H = 179 mm D = 72 mm Protection class: 2 Supply voltage: AC: 80 V – 270 V DC: 60 V – 375 V Power consumption: 4 VA max. (depends upon supply voltage, kind of interface module and operating status of transmission unit) Interfaces: Pluggable modules; available are: - RS232 (supports signals

  • Page 12 of 12 UniMod GSM-3 Operation Manual Bär Industrie-Elektronik GmbH ⋅ Rathsbergstr. 23 ⋅ D-90411 Nürnberg ⋅ Phone +49 911 970590 ⋅ Fax +49 911 9705950 12. Inserting the Interface Modules When inserting the interface modules their component side must be at the left side and wired accord- ing the picture. In the following sketch the components are at the left side.

More Instructions:

DOWNLOAD

Related Products and Documents (Modem):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 IKEA sewing machine Instruction manual ikea/sewing-machine-T24.pdf 15 Feb 2023 81
2 Fostex AP1020 Owner's manual fostex/ap1020-2EO.pdf 18 Sep 2022 10 0.26 Mb
3 Garland MCO-25L Specifications garland/mco-25l-5K9.pdf 07 Sep 2023 2 0.25 Mb
4 VTech 5801 Operation & user’s manual vtech/5801-U35.pdf 27 Oct 2023 44 1.6 Mb
5 Dukane 8766 Operation & user’s manual dukane/8766-OKM.pdf 07 Jul 2023 38 2.79 Mb
6 Haier FCD-JTHSA80-III Operation & user’s manual haier/fcd-jthsa80-iii-2J6.pdf 02 Dec 2022 6 1.99 Mb

Similar Resources:

  • Kathrein

    27445

    (2 pages)
    Modem-SteckdosenModem socketsPrises modemQFür interaktive CATV-/HFC-NetzeQSehr hohe Entkopplung zwischen Modem-Anschluss und TV-/FM-Anschluss verhindert Störungen des TV-/Radio-Empfanges durch das ModemQIngress Noise Blocking-Funktion verhindert die Einstrahlung von unerwünschten Störsignalen über die Teilnehmer-EndgeräteQSelektive Signal-Aufteilung au …
  • Sierra Wireless

    compass series

    (32 pages)
    Compass™ Series USB Modemwww.sierrawireless.comQuick Start GuideSchnellstart-HandbuchGuide de démarrage rapideGuida rapidaGuía de inicio rápido Pierwsze krokiStručná příručkaクイック スタート ガイド …
  • Zte

    Winknet UUZ300

    (2 pages)
    3. Insert the microSD card into the microSD card slot. Notes:This modem only supports microSD card. Insert your microSD card into the microSD card slot, shown as the following picture.4. Putthefrontcoverofthemodematlyuponthebodyofmodem.Directthe front cover towards the locking catches on the sides of the mod …
  • Square One Industries

    5614HP

    (30 pages)
      � …
  • AT&T

    Wireless Home Phone Base

    (2 pages)
    Getting to Know Your Device For more information, refer to your User Guide, visit att.com/devicehowto, or call AT&T Support at 1-800-331-0500.Before You BeginThe AT&T Home Base uses the AT&T cellular network and DOES NOT use your home phone wall jacks.Your device should be located:•   Where you have a strong signal from a c …
  • Paradyne

    3800PLUS

    (2 pages)
    You have accessed an older version of aParadyne product document.Paradyne is no longer a subsidiary ofAT&T. Any reference to AT&T Paradyne isamended to read Paradyne Corporation. …

Comments, Questions and Opinions: