ANTAIRA LNX-802AG-S10-T Operation & User’s Manual
|
ANTAIRA LNX-802AG-S10-T, FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no guarantee that interference will
Content Introduction ................................................................ 1 Feature ..................................................................... 1 Package Contents .................................................... 3 Hardware Description ............................................... 4 Physical Dimension .................................................. 4 F
ANTAIRA LNX-802AG-S10-T, 1 Introduction The 6 10/100/1000TX + 2G fiber industrial switch is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. By using fiber port can extend the connection distance that increases the network elasticity and performance. And also support wide operation temperature and green power features. Feature Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3z Gigabit fiber IEEE 802.3x Flow Control and Back Pressure LED Indicat
2 MAC address 8K MAC address table with Auto learning function Power Supply DC 12~48V, Redundant power and removable terminal block 24VAC (18~30V) Power Consumption 9.3 Watt (Max) Ventilation Fanless Operating Temperature -40℃~75℃ -40℃~60℃ (non-air-flow environment) Operating Humidity 5% to 95% Storage environment -40℃~85℃
ANTAIRA LNX-802AG-S10-T, 3 ■ EN61000-4-8 (Magnetic Field) ■ EN61000-4-11 (Voltage Dip) ■ EN61000-4-12 (Oscillatory waves) ■ EN61000-3-2 (Harmonics Current) ■ EN61000-3-3 (Voltage Fluctuation & Flickers) Safety ■ UL508 ■ Class 1 Division 2 Stability Testing ■ IEC60068-2-32 (Free fall) ■ IEC60068-2-27 (Shock) ■ IEC60068-2-6 (Vibration) Package Contents Please refer to the package content list below to verify them against the checklist. 6 10/100/1000TX + 2 Gigabit fiber industrial switch
ANTAIRA LNX-802AG-S10-T, 4 Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. Physical Dimension 6 10/100/1000TX + 2G fiber industrial switch dimension (W x D x H) is 59.6mm x 105mm x 152mm
ANTAIRA LNX-802AG-S10-T, 5 Front Panel The Front Panel of the 6 10/100/1000TX +2G fiber industrial switch is shown as below: Front Panel of the industrial switch Top View The top panel of the 6 10/100/1000TX + 2G fiber industrial switch has one terminal block connector of two DC power inputs. Top Panel of the industrial switch
ANTAIRA LNX-802AG-S10-T, 6 LED Indicators There are diagnostic LED indicators located on the front panel of the industrial switch. They provide real-time information of system and optional status. The following table provides description of the LED status and their meanings for the switch. LED Status Description Per Unit PWR1(Green) On Power input 1 is active Off Power input 1 is inactive BLK -- PWR2(Green) On Power input 2 is active Off Power input 2 is inactive BLK -- P-FAIL(Red) On Power1/Power2 is inactive Off Power1 and Power2 are both active, or no power input BLK -- Link/Active for Fiber(Gre
ANTAIRA LNX-802AG-S10-T, 7 Off 100Mbps BLK -- Green Ethernet The 6 10/100/1000TX + 2G fiber industrial switch has a special function. The switch will automatically detect Ethernet ports status and Cable Length and adjust power efficiency. Below table shows 6 10/100/1000TX + 2G fiber industrial switch power consumption. Link Up: Cable Length 20m Green power (off/on) Consumption (Watts) OFF 6.9 ON 5.85 Gap 0.34 Saving % 5.49%
ANTAIRA LNX-802AG-S10-T, 1 Hardware Installation In this paragraph, we will describe how to install the 6 10/100/1000TX + 2G fiber industrial switch and the installation points to be attended to it. Installation Steps 1. Unpack the Industrial switch 2. Check if the DIN-Rail is screwed on the Industrial switch or not. If the DIN-Rail is not screwed on the Industrial switch, please refer to DIN-Rail Mounting section for DIN- Rail installation. If user wants to wall mount the Industrial switch, then please refer to Wall Mount Plate Mounting section for wall mount plate installation. 3. To hang the Industrial switch on the DIN-Rail track or wall, please refer to the Mounting Installation
ANTAIRA LNX-802AG-S10-T, 2 less than 100 meters (328 ft.) long. Fiber segment using single-mode connector type must use 9/125µm single-mode fiber cable. User can connect two devices in the distance up to 10 Kilometers. Fiber segment using multi-mode connector type must use 50/125 or 62.5/125 µm multi-mode fiber cable. User can connect two devices up to 550m distances. Wiring the Power Inputs Please follow the steps below to wire the power cord which from the other compliant external DC power supplier. 1. Insert the positive and negative wi
ANTAIRA LNX-802AG-S10-T, 3 Wiring the P-Fail Alarm Contact The P-Fail alarm contact is in the middle of terminal block connector as the picture shows below. Inserting the wires, will detect the P-Fail status including power failure or port link failure (managed industrial switch only) and from a Normally Close circuit. Please refer to the diagrams below for the P-Fail alarm contact, and the application example for the P-Fail alarm operation. Insert the wires into the P-Fail alarm contact. Note The wire gauge for the terminal block should be in the range between 12~
5 3. Check if the DIN-Rail is tightened on the track or not. 4. To remove the industrial switch from the track, reverse steps above. Wall Mount Plate Mounting Follow the steps as below to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN- Rail. 2. Place the wall mount plate on the re
ANTAIRA LNX-802AG-S10-T, 7 Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch is shown as below.
ANTAIRA LNX-802AG-S10-T, 8 Troubles shooting Verify that is using the right power cord/adapter (DC 12-48V), please don’t use the power adapter with DC output higher than 48V, or it will burn this converter down. Select the proper UTP cable to construct user network. Please check that is using the right cable. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps connections or 100Ω Category 5/5e cable for 100Mbps connections or 100�
ANTAIRA LNP-2004G-SFP Series Network Router Operation & user’s manual
LNP-2004G-SFP Series |
ANTAIRA LNX-800AG Network Router Operation & user’s manual
LNX-800AG |
ANTAIRA LMX-0702G-SFP-V2 Series Network Router Hardware manual
LMX-0702G-SFP-V2 Series |
ANTAIRA STE-6104C-T-V2 Network Router Quick installation manual
STE-6104C-T-V2 |
ANTAIRA LMP-0501-24-V2 Series Network Router Hardware manual
LMP-0501-24-V2 Series |
ANTAIRA LNP-C500G-T Network Router Operation & user’s manual
LNP-C500G-T |
ANTAIRA LNP-0500G-BT Series Network Router Quick installation manual
LNP-0500G-BT Series |
ANTAIRA LNP-2804GN-SFP-T Network Router Operation & user’s manual
LNP-2804GN-SFP-T |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | JVC | CA-MXSK1 | Instructions manual | jvc/ca-mxsk1-2B6.pdf | 01 Nov 2023 | 116 | |
2 | Nokia | NOKIA N97 mini | Operation & user’s manual | nokia/nokia-n97-mini-588.pdf | 20 Oct 2023 | 130 | |
3 | Asko | W8844XL W | Installation instructions manual | asko/w8844xl-w-1B9.pdf | 14 Aug 2022 | 8 | |
4 | Maytag | MVWB450WQ - Bravos 5.0 cu. Ft. IEC Capacity Washer | Energy manual | maytag/mvwb450wq-bravos-5-0-cu-ft-iec-capacity-washer-N96.pdf | 16 Jan 2023 | 2 | |
5 | Makita | UH4261 | Instruction manual | makita/uh4261-DNH.pdf | 18 Aug 2023 | 48 | |
6 | Vicon | VM621-5 | Manual | vicon/vm621-5-2W1.pdf | 16 Nov 2022 | 13 |
D-Link
DSA-3200 Wireless Service Gateway User Manual © 2005 D-Link Systems Co., Ltd. DSA-3200 Wireless G Public/Private Gateway User Manual (2/8/2005)
…
DSA-3200(113 pages) |
HP
HP FlexFabric 12900 Switch Series Layer 2—LAN Switching Configuration Guide Part number: 5998-7268 Software version: R103x Document version: 6W100-20150116
…
FlexFabric 12900 series(243 pages) |
Grandstream Networks
Grandstream Networks, Inc. Analog IP Gateway GXW-410x 4 or 8 FXO Ports w/Video Surveillance GXW-410x User’s Manual www.grandstream.com Firmware Version 1.0.0.32 [email protected]
…
GXW-410x(34 pages) |
Belkin
WI-FI PROTECTED ACCESS (WPA) ADDENDUM (FOR XP USERS)802.11g Wireless Notebook Network Card (F5D7010)802.11g Wireless Desktop Network Card (F5D7000)OverviewWPA is a new standards-based wireless security solution developed by the Wi-Fi Alliance. It alsosupports the legacy security standard called WEP (Wired Equivalent Privacy). To use WPA security,your clients …
F5D7000(2 pages) |
Huawei
Huawei Technologies Proprietary HUAWEI 1. Getting Started 2. Port 3. VLAN 4. Network Protocol 5. Routing Protocol 6. Multicast Protocol 7. QoS/ACL 8. STP 9. Security 10. Reliability 11. System Management 12. PoE 13. Appendix Quidway S6500 Series Ethernet Switches Command Manual Release 3000 Series
…
Quidway S6500 Series(845 pages) |
Zte
ZXR105900ESeriesAllGigabit-PortIntelligentRoutingSwitchHardwareManualVersion2.8.23.BZTECORPORATIONZTEPlaza,KejiRoadSouth,Hi-TechIndustrialPark,NanshanDistrict,Shenzhen,P .R.China518057Tel:(86)75526771900Fax:(86)75526770801URL:http://ensupport.zte.com.cnE-mail:[email protected]
…
ZXR10 5900E Series(35 pages) |
Hawking Adapter HGU1Hawking Product User Guide: HGU1 PDF Quick installation manual - U5K3GD HGU1, 12 |
Beckhoff Network Card FC9001-0010Beckhoff Product Guide: FC9001-0010 PDF Installation and operating instructions manual - 259TX1 FC9001-0010, 43 |
KOBE Ventilation Hood CH2230SQKOBE Ventilation Hood CH2230SQ Installation instructions and operation manual CH2230SQ, 31 |
Blodgett Kitchen Appliances SB-10E-6KSB-10E-6K (Kitchen Appliances ePDF Guide, #16O33P) SB-10E-6K, 2 |
Armchair TV Accessories TV PicShareArmchair TV Accessories Operation & user’s manual (File: armchair-tv-picshare-tv-accessories-48, Sunday 20-08-2023) TV PicShare, 48 |
Maytag Dryer MEDZ600TB0Maytag Product Manual: MEDZ600TB0 PDF Parts list - 34U3NK MEDZ600TB0, 8 |
Delfield Refrigerator F15MC48DManual: Delfield F15MC48D (21T897, Upd.04.09.2023) F15MC48D, 2 |
Alto Enclosure MS12AOwner's manual for Alto MS12A Enclosure MS12A, 16 |
KitchenAid Refrigerator KUIC15NHZSKUIC15NHZS Quick start manual - 3863X3 KUIC15NHZS, 2 |
Panasonic Accessory Viera TC-L32X2Panasonic Viera TC-L32X2 Guide (Doc Type: Accessory Start here) Viera TC-L32X2, 1 |
Ryobi Vacuum Cleaner VC722VC120VC722VC120 Operator's manual - 85B64S VC722VC120, 2 |
Peterson Software StroboSoft 2.0Peterson Software Owner's manual (File: peterson-strobosoft-2-0-owner-s-manual-62, Mon 11.2023) StroboSoft 2.0, 62 |