Manualios.com

ANTAIRA LNX-802AG-S10-T Operation & User’s Manual

  • LNX-802AG-S10-T Network Router
  • maFuu0K33TP8g
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 18

ANTAIRA LNX-802AG-S10-T Manual Online:

3.15, 2361 votes
ANTAIRA LNX-802AG-S10-T User Manual
ANTAIRA LNX-802AG-S10-T User Guide
ANTAIRA LNX-802AG-S10-T Online Manual

Text of ANTAIRA LNX-802AG-S10-T User Guide:

  • ANTAIRA LNX-802AG-S10-T, FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions. However, there is no guarantee that interference will

  • Content Introduction ................................................................ 1 Feature ..................................................................... 1 Package Contents .................................................... 3 Hardware Description ............................................... 4 Physical Dimension .................................................. 4 F

  • ANTAIRA LNX-802AG-S10-T, 1 Introduction The 6 10/100/1000TX + 2G fiber industrial switch is a cost-effective solution and meets the high reliability requirements demanded by industrial applications. By using fiber port can extend the connection distance that increases the network elasticity and performance. And also support wide operation temperature and green power features. Feature Standard IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX IEEE 802.3ab 1000Base-T IEEE 802.3z Gigabit fiber IEEE 802.3x Flow Control and Back Pressure LED Indicat

  • 2 MAC address 8K MAC address table with Auto learning function Power Supply DC 12~48V, Redundant power and removable terminal block 24VAC (18~30V) Power Consumption 9.3 Watt (Max) Ventilation Fanless Operating Temperature -40℃~75℃ -40℃~60℃ (non-air-flow environment) Operating Humidity 5% to 95% Storage environment -40℃~85℃

  • ANTAIRA LNX-802AG-S10-T, 3 ■ EN61000-4-8 (Magnetic Field) ■ EN61000-4-11 (Voltage Dip) ■ EN61000-4-12 (Oscillatory waves) ■ EN61000-3-2 (Harmonics Current) ■ EN61000-3-3 (Voltage Fluctuation & Flickers) Safety ■ UL508 ■ Class 1 Division 2 Stability Testing ■ IEC60068-2-32 (Free fall) ■ IEC60068-2-27 (Shock) ■ IEC60068-2-6 (Vibration) Package Contents Please refer to the package content list below to verify them against the checklist.  6 10/100/1000TX + 2 Gigabit fiber industrial switch 

  • ANTAIRA LNX-802AG-S10-T, 4 Hardware Description In this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling information, and wiring installation. Physical Dimension 6 10/100/1000TX + 2G fiber industrial switch dimension (W x D x H) is 59.6mm x 105mm x 152mm

  • ANTAIRA LNX-802AG-S10-T, 5 Front Panel The Front Panel of the 6 10/100/1000TX +2G fiber industrial switch is shown as below: Front Panel of the industrial switch Top View The top panel of the 6 10/100/1000TX + 2G fiber industrial switch has one terminal block connector of two DC power inputs. Top Panel of the industrial switch

  • ANTAIRA LNX-802AG-S10-T, 6 LED Indicators There are diagnostic LED indicators located on the front panel of the industrial switch. They provide real-time information of system and optional status. The following table provides description of the LED status and their meanings for the switch. LED Status Description Per Unit PWR1(Green) On Power input 1 is active Off Power input 1 is inactive BLK -- PWR2(Green) On Power input 2 is active Off Power input 2 is inactive BLK -- P-FAIL(Red) On Power1/Power2 is inactive Off Power1 and Power2 are both active, or no power input BLK -- Link/Active for Fiber(Gre

  • ANTAIRA LNX-802AG-S10-T, 7 Off 100Mbps BLK -- Green Ethernet The 6 10/100/1000TX + 2G fiber industrial switch has a special function. The switch will automatically detect Ethernet ports status and Cable Length and adjust power efficiency. Below table shows 6 10/100/1000TX + 2G fiber industrial switch power consumption. Link Up: Cable Length 20m Green power (off/on) Consumption (Watts) OFF 6.9 ON 5.85 Gap 0.34 Saving % 5.49%

  • ANTAIRA LNX-802AG-S10-T, 1 Hardware Installation In this paragraph, we will describe how to install the 6 10/100/1000TX + 2G fiber industrial switch and the installation points to be attended to it. Installation Steps 1. Unpack the Industrial switch 2. Check if the DIN-Rail is screwed on the Industrial switch or not. If the DIN-Rail is not screwed on the Industrial switch, please refer to DIN-Rail Mounting section for DIN- Rail installation. If user wants to wall mount the Industrial switch, then please refer to Wall Mount Plate Mounting section for wall mount plate installation. 3. To hang the Industrial switch on the DIN-Rail track or wall, please refer to the Mounting Installation

  • ANTAIRA LNX-802AG-S10-T, 2 less than 100 meters (328 ft.) long.  Fiber segment using single-mode connector type must use 9/125µm single-mode fiber cable. User can connect two devices in the distance up to 10 Kilometers.  Fiber segment using multi-mode connector type must use 50/125 or 62.5/125 µm multi-mode fiber cable. User can connect two devices up to 550m distances. Wiring the Power Inputs Please follow the steps below to wire the power cord which from the other compliant external DC power supplier. 1. Insert the positive and negative wi

  • ANTAIRA LNX-802AG-S10-T, 3 Wiring the P-Fail Alarm Contact The P-Fail alarm contact is in the middle of terminal block connector as the picture shows below. Inserting the wires, will detect the P-Fail status including power failure or port link failure (managed industrial switch only) and from a Normally Close circuit. Please refer to the diagrams below for the P-Fail alarm contact, and the application example for the P-Fail alarm operation. Insert the wires into the P-Fail alarm contact. Note The wire gauge for the terminal block should be in the range between 12~

  • 5 3. Check if the DIN-Rail is tightened on the track or not. 4. To remove the industrial switch from the track, reverse steps above. Wall Mount Plate Mounting Follow the steps as below to mount the industrial switch with wall mount plate. 1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN- Rail. 2. Place the wall mount plate on the re

  • ANTAIRA LNX-802AG-S10-T, 7 Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application. A sample application of the industrial switch is shown as below.

  • ANTAIRA LNX-802AG-S10-T, 8 Troubles shooting  Verify that is using the right power cord/adapter (DC 12-48V), please don’t use the power adapter with DC output higher than 48V, or it will burn this converter down.  Select the proper UTP cable to construct user network. Please check that is using the right cable. Use unshielded twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections: 100Ω Category 3, 4 or 5 cable for 10Mbps connections or 100Ω Category 5/5e cable for 100Mbps connections or 100�

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 JVC CA-MXSK1 Instructions manual jvc/ca-mxsk1-2B6.pdf 01 Nov 2023 116
2 Nokia NOKIA N97 mini Operation & user’s manual nokia/nokia-n97-mini-588.pdf 20 Oct 2023 130
3 Asko W8844XL W Installation instructions manual asko/w8844xl-w-1B9.pdf 14 Aug 2022 8
4 Maytag MVWB450WQ - Bravos 5.0 cu. Ft. IEC Capacity Washer Energy manual maytag/mvwb450wq-bravos-5-0-cu-ft-iec-capacity-washer-N96.pdf 16 Jan 2023 2
5 Makita UH4261 Instruction manual makita/uh4261-DNH.pdf 18 Aug 2023 48
6 Vicon VM621-5 Manual  vicon/vm621-5-2W1.pdf 16 Nov 2022 13

Similar Resources:

  • D-Link

    DSA-3200

    (113 pages)
    DSA-3200 Wireless Service Gateway User Manual © 2005 D-Link Systems Co., Ltd. DSA-3200 Wireless G Public/Private Gateway User Manual (2/8/2005) …
  • HP

    FlexFabric 12900 series

    (243 pages)
    HP FlexFabric 12900 Switch Series Layer 2—LAN Switching Configuration Guide Part number: 5998-7268 Software version: R103x Document version: 6W100-20150116 …
  • Grandstream Networks

    GXW-410x

    (34 pages)
    Grandstream Networks, Inc. Analog IP Gateway GXW-410x 4 or 8 FXO Ports w/Video Surveillance GXW-410x User’s Manual www.grandstream.com Firmware Version 1.0.0.32 [email protected]
  • Belkin

    F5D7000

    (2 pages)
    WI-FI PROTECTED ACCESS (WPA) ADDENDUM (FOR XP USERS)802.11g Wireless Notebook Network Card (F5D7010)802.11g Wireless Desktop Network Card (F5D7000)OverviewWPA is a new standards-based wireless security solution developed by the Wi-Fi Alliance. It alsosupports the legacy security standard called WEP (Wired Equivalent Privacy). To use WPA security,your clients …
  • Huawei

    Quidway S6500 Series

    (845 pages)
    Huawei Technologies Proprietary HUAWEI 1. Getting Started 2. Port 3. VLAN 4. Network Protocol 5. Routing Protocol 6. Multicast Protocol 7. QoS/ACL 8. STP 9. Security 10. Reliability 11. System Management 12. PoE 13. Appendix Quidway S6500 Series Ethernet Switches Command Manual Release 3000 Series …
  • Zte

    ZXR10 5900E Series

    (35 pages)
    ZXR105900ESeriesAllGigabit-PortIntelligentRoutingSwitchHardwareManualVersion2.8.23.BZTECORPORATIONZTEPlaza,KejiRoadSouth,Hi-TechIndustrialPark,NanshanDistrict,Shenzhen,P .R.China518057Tel:(86)75526771900Fax:(86)75526770801URL:http://ensupport.zte.com.cnE-mail:[email protected]

Comments, Questions and Opinions: