Amprobe AT-7000 Operation & User’s Manual
|
Amprobe AT-7000, 27 Figure 4.10b Figure 4.10c 7. PRESS ENTER when complete to return to home screen. *Note: For best results, keep the receiver at least 3 feet from the transmitter and its test leads to minimize signal interference and improve wire tracing results. 4.11 Locating Loads (Signal Clamp) The clamp accessory can be used to map loads to specific breakers on both energized and de-energized systems. There is no need to disconnect power. 1. Clamp the SC-7000 around the wire at the breaker panel. 2. Set up the transmitter and receiver as described
Amprobe AT-7000, 12 3.1 Tracing Energized Wires SMART SENSOR The SMART SENSOR enables easier wire tracing by showing the direction and position of the wire and is the recommended method for tracing energized wires (does not work on de-energized circuits, use de-energized TIP SENSOR for that application). Connecting transmitter test leads 1. Connect green and red test leads to the transmitter (polarity does not matter) 2. . Connect red lead to energized hot wire (on the load side of the system). The signal will ONLY be transmitted between the outlet to which the transmitter is connected and the source of power (see Figure 3a). 3. Connect green wire
Amprobe AT-7000, 4 Symbols used in this product Battery status – Displays the remaining battery charge Home – Return to home screen when selected Help – Enters to the help mode when selected Settings – Enters to the settings menu when selected Volume– Displays the volume in four levels Sensitivity indicator – Displays the sensitivity level from 1 to 10. Icon indicating energized system Icon indicating de-energized system 99 SIGNAL Signal strength indicator – Shows the strength of the signal from 0 to 99 MAN/AUTO Shows whether the sensitivity adjustment is in Manual or Automat
Amprobe AT-7000, AT-7000 Advanced Wire Tracer AT-7020 AT-7030 User Manual 10/2017, 4394127 Rev B ©2017 Amprobe Test Tools. All rights reserved. English www.GlobalTestSupply.com Find Quality Products Online at: [email protected]
25 4.7 Tracing Underground Wires The AT-7000 can trace wires underground, the same way it can locate wires behind walls or floors. Perform tracing as described in Energized SMART SENSOR mode or Energized / De-Energized TIP SENSOR modes. You can use a hot sick attachment to make tracing more ergonomic and convenient. Connect the transmitter as shown in the diagram. AT-70
Amprobe AT-7000, 11 • �IMPORTANT NOTICE, PLEASE READ BEFORE YOU START TRACING Avoiding signal cancellation problems with a separate ground connection The signal generated by the transmitter creates an electromagnetic field around the wire. This field is what is detectable by the receiver. The clearer this signal, the easier it is to trace the wire. If transmitter is connected to two adjacent wires on the same circuit (for example, hot and neutral wires on a Romax cable), the signal travels in one directions through the first wire and then returns (with opposite direction) through the second one. This causes creation of two electromag
21 4. Step 2 - 2 LOCATE a) Select LOCATE mode by using the directional arrows to highlight this operating mode and pressing the yellow “ENTER” button. b) Scan each breaker again for a half second each by touching it with the Tip Sensor. Active red arrow indicates scanning process. Make sure the groove on the Tip Sensor is parallel to the breaker leng
Amprobe AT-7000, 13 Using AT-7000-R Receiver 1. Press ‘ON/OFF’ push button to turn on the receiver and wait for the home screen (boot up time is around 30 seconds). 2. Select SMART SENSOR mode by using the directional arrows to highlight this operating mode and pressing the yellow ENTER button. 3. Hold the receiver with the Smart Sensor on the rear of the unit facing the target area. If the screen flashes a “?” in a red target then no signal is detected. Move the Smart Sensor closer to the target area until the signal is detected and you see a directional arrow. If no signal is detected increase the sensitivity using the “+” button on the receiver. (see Figure 3
Amprobe AT-7000, 19 Step 1 - 1 SCAN: 1. The unit will automatically start in 1 SCAN mode as shown in Figure 3.3b. 2. Scan each breaker for a half second by touching it with the Tip Sensor. Make sure the groove on the Tip Sensor is parallel to the breaker lengthwise (See Figure 3.3d) 3. To assure sufficient time between the scans, wait for active green arrow and audible alert (2-beeps) before moving to the next breaker. 4. Scan all breakers – the order of scanning does not matter. You can scan breakers multiple times. The recei
Amprobe AT-7000, 5 This manual contains information and warnings that must be followed for operating the tester safely and maintaining the tester in a safe operating condition. If the tester is used in a manner not specified by the manufacturer, the protection provided by the tester may be impaired. This tester meets water and dust protection IP40 per IEC60529 Ed 2.1 (2001). Do not use in rainfall! The tester is double insulated for protection per EN61010-1:2010 3rd Ed to CAT IV 600V. (AT-7000-R) and CAT IV 300V MAX (AT-7000-T) CAUTION: Do not connect the Transmitter to a separate ground in
Amprobe AT-7000, 26 4.10 No Access to Bare Conductors (Signal Clamp) The clamp accessory is used for applications where there is no access to the bare conductor to connect transmitter test leads. When clamp is connected to the transmitter, it enables the AT-7000-T to induce signal to energized or de-energized wire through the insulation. The signal will travel through the wire both directions and it will affect all the branches. This method is safe to use for any sensitive electronic equipment. Connect the clamp 1. Connect the
Amprobe AT-7000, 1 AT-7000 Series CONTENTS 1. PRECAUTIONS AND SAFETY MEASURES ............................................................. 2 2. KIT COMPONENTS ................................................................................................. 5 2.1 AT-7000-R Receiver ........................................................................................................6 2.2 AT-7000-T Transmitter ...................................................................................................8 2.3 TL-7000 Test Lead & Accessory Kit ................................................................................9 2.4 SC-7000 Signal Clamp (AT-7030 Kit) ..................
Amprobe AT-7000, 28 5. MAINTENANCE Changing battery for transmitter: The battery compartment on the back of the AT-7000-T is designed to make it easy for the user to change the battery. A screw is added to secure the battery in case the unit is dropped. 6 AA rechargeable batteries or 6 AA alkaline batteries may be used. 6 x AA batteries Screws Battery Cover 1. Make sure that the Transmitter is turned off. 2. Use the star screw driver to unscrew the holding screws. 3. Remove the battery cover. 4. Install Batteries using the battery clip. 5. Replace the battery cover and secure it with the provided screw. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]
7 ENERGIZED: DE-ENERGIZED: -- Main applications Setting menu Help guide Buzzer volume adjustment Sensitivity adjustment Figure 1a: Overview of all elements on home screen Home menu Figure 1b: Overview of all elements on the setting menu Language English, French, German, Spanish, Italian Backlight 25%, 50%, 75%, 100% Setting DEFAULT : Restore default set
14 3.1 Tracing Energized Wires TIP SENSOR TIP SENSOR mode is used for the following applications: pinpointing a wire in a bundle, tracing in corners and confined spaces such as junction boxes or inside enclosures. Connecting transmitter test leads 1. Connect green and red test leads to the transmitter (polarity does not matter) 2. Connect red lead to energized hot wire (on the load side
Amprobe AT-7000, 17 Using AT-7000-R Receiver 1. Press ‘ON/OFF’ push button to turn on the receiver and wait for the home screen (boot up time is around 30 seconds). 2. Select De-Energized TIP SENSOR mode by using the directional arrows to highlight this operating mode and pressing the yellow “ENTER” button. Screen will appear as shown in Figure 3.2c 3. Hold the receiver with the Tip Sensor facing the target area.* 4. Scan target area with Tip Sensor to find highest signal level. While tracing, periodically adjust sensitivity to keep signal strength near 75. Increase or decrease sensitivity by pressing + or – on the keypad. If si
Amprobe AT-7000, 29 Changing receiver battery: The battery compartment on the back of the AT-7000-R is designed to make changing batteries easy. Four (4) AA 1.5V alkaline or 1.2V rechargeable batteries may be used. 4 x AA batteries Screws Battery Cover Figure 5.2: Changing receiver battery 1. Make sure that the Receiver is turned off. 2. Use screw driver to unscrew the captive screw. 3. Remove the battery cover. 4. Install batteries using the battery clip. 5. Replace the battery cover and secure it with the provided screw. 5. MAINTENANCE www.GlobalTestSupply.com Find Quality Products Online at: [email protected]
Amprobe AT-7000, 31 6. SPECIFICATIONS AT-7000-R AT-7000-T SC-7000 LCD size 3.5" 1.77" NA LCD Dimensions 2.76 x 2.07 1.1 x 1.38 in NA LCD Resolution (pixels) 320 x 240 128 x 160 NA LCD type TFT RGB x TFT NA Color LCD Yes Yes NA Backlight Yes Yes NA mDDR 64 MB 64 MB NA FLASH memory 128 MB 128 MB NA Audio 95 dB No NA Operating Temperature range 0 to 120F (-17.77C to 49C) 0°F to 120°F (-17.77°C to 49°C) 0°F to 120°F (-17.77°C to 49°C) Storage Temperature (-40 to 150F) (-40 to 65.5C) -40°F to 150°F (-40°C to 65.5°C) -40°F to 150°F (-40°C to 65.5°C) Operating Humidity 95% R.H max 95% R.H max 95% R.H max Operati
Amprobe AT-7000, 16 3.2 Tracing De-energized Wires TIP SENSOR De-energized TIP SENSOR mode is used for general wire tracing, pinpointing wires in bundles, tracing in tight corners and confined spaces such as junction boxes or inside enclosures. Connecting transmitter test leads 1. Connect green and red test leads to the transmitter (polarity does not matter) 2. Connect red lead to de-energized hot wire (on the load side of the system). In de-energized mode the signal will be injected to ALL branches of the circuit, not just between the outlet and the
Amprobe AT-7000, 3 �Warnings: Read Before Using To avoid possible electric shock or personal injury: • Use the Meter only as specified in this manual or the protection provided by the instrument might be impaired. • Avoid working alone so assistance can be rendered. • Never measure ac current while the test leads are inserted into the input jacks. • Do not use the Meter in wet or damp environments. • Do not use the Meter if it appears damaged. Inspect the Meter before use. Look for cracks or missing plastic. Pay particular attention to the insulation around the connectors. • Inspect the test leads be
DOWNLOAD |
Amprobe NCV-1020 GPS Operation & user’s manual
NCV-1020 |
Amprobe TMA10A GPS Operation & user’s manual
TMA10A |
Amprobe PQ55A GPS Operation & user’s manual
PQ55A |
Amprobe ACD - 50NAV GPS Operation & user’s manual
ACD - 50NAV |
Amprobe CO2-100 GPS Operation & user’s manual
CO2-100 |
Amprobe ACD-400 GPS Operation & user’s manual
ACD-400 |
Amprobe TIC 300 PRO GPS Operation & user’s manual
TIC 300 PRO |
Amprobe AT-6020 GPS Operation & user’s manual
AT-6020 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Foxconn | MARS | Operation & user’s manual | foxconn/mars-YDL.pdf | 08 Apr 2023 | 110 | 2.33 Mb |
2 | Crate | GX-60C | Owner's manual | crate/gx-60c-1M2.pdf | 08 Aug 2022 | 4 | 2.06 Mb |
3 | Elo TouchSystems | ET1525C | Operation & user’s manual | elo-touchsystems/et1525c-635.pdf | 02 Nov 2023 | 48 | 0.36 Mb |
4 | RCA | DRC300iH | Information sheet | rca/drc300ih-BZP.pdf | 02 May 2023 | 1 | 0.11 Mb |
5 | Toastmaster | TBR20H | Use and care manual | toastmaster/tbr20h-F1B.pdf | 20 Dec 2022 | 64 | 0.94 Mb |
6 | OPTICOM | SR5800D-8 | Datasheet | opticom/sr5800d-8-24R.pdf | 30 Oct 2022 | 2 |
LITE-In
Bluetooth GPS Receiver GSF3000 Directory LGSF3000 Bluetooth GPS Receiver Express Directory 7. 7, 2006 V1.0 LITE-In Tech. Co., Ltd., 4F, No. 20, Lane 50, Sec. 3, Nangang Rd., Taipei 115, Taiwan, R.O.C. Phone:+886-2-2786-3636 Fax:+886-2-2783-0909 E-Mail:[email protected] Web:http: …
LGSF3000(9 pages) |
gtt systems
GTTSystems B.V. Herfordstraat 16 7418 EX Deventer T 0570 605075 F 0570 677755 E [email protected] W www.gtts.eu Brief Installation Manual GTTS-2000B V1.3 GTTS-2000B Iridium Global Tracking & Tracing System Prior to mechanical installation the GTTS unit shall be activated in the Iridium Satellite Network. Send an email to [email protected] with …
GTTS-2000B(2 pages) |
Garmin
GPSMAP 230The Home Theatre Of GPS ChartplottingThe new GARMIN GPSMAP 230 offers boaters advanced GPSperformance on a 7.1" diagonal, track up display that’s sure to setthe standard for big-screen chartplotting. Add in simple, menu-driven operation, G-chart cartography with seamless Navionicscharts, and a powerful, 12 parallel channel GPS receiver, and …
GPSMAP230(2 pages) |
Holux
GPS Receiver May. 28, 2003 HOLUX Technology,.Inc 8F-11, 26, Tai Yuen St., Chu Pei, Hsin Chu, Taiwan Phone: +886-3-5526268 Fax: +886-3-5526108 E-Mail: [email protected] Web: www.holux.com.tw All Right Reserved User’s Guide GM-210 HOLUX
…
GM-210(14 pages) |
Lantronix
Application Note Improving Asset Tracking Through Untethered Dead Reckoning with FOX3-3G-DR Part Number APP-0008 Revision A October 2019
…
FOX3-3G-DR(10 pages) |
Edgetech
EdgeTech 4 Little Brook Road West Wareham, MA 02576 Tel: (508) 291-0057 Fax: (508) 291-2491 www.EdgeTech.com USBL BROADBAND ACOUSTIC TRACKING SYSTEM (BATS) USER HARDWARE MANUAL 0018257_REV_A November 2017
…
USBL BROADBAND ACOUSTIC TRACKING SYSTEM(102 pages) |
Dyson Vacuum Cleaner DC 05PDF Guide (@WH8O7G), Dyson DC 05 Vacuum Cleaner (Tuesday 12-09-2023) DC 05, 10 |
Kramer Repeater VS-40FWKramer Repeater VS-40FW Operation & user’s manual VS-40FW, 13 |
Phanteks Computer Accessories Enthoo EVOLV ITXComputer Accessories PDF Operation & user’s manual Enthoo EVOLV ITX, 14 |
Toshiba Storage MG03ACA400#T7F353 MG03ACA400: Toshiba Storage Owner Documentation MG03ACA400, 2 |
Roper Oven B4607B0Oven PDF Use and care manual B4607B0, 12 |
Braun Clock Radio BNC010-RCBraun BNC010-RC Clock Radio User instructions BNC010-RC, 4 |
Indesit Washer/Dryer WIDL146User Guide: Indesit WIDL146 (HU467X, Upd.14/01/2024) WIDL146, 36 |
Paxar Printer Monarch Pathfinder Ultra Platinum 6039Printer #UQD63I Monarch Pathfinder Ultra Platinum 6039, 2 |
NEFF Other B12M32N0EUB12M32N0EU (Other ePDF Manual, #RII2ZG) B12M32N0EU, 48 |
Samsung Speaker System HT-SB1GOperation & user’s manual for Samsung HT-SB1G Speaker System HT-SB1G, 25 |
Atlas Inverter MG2500#1P25C9: MG2500 Inverter Operation manual MG2500, 22 |
Intel Motherboard D925XHYProduct manual for Intel D925XHY Motherboard D925XHY, 68 |