Manualios.com

Amprobe AT-7000 Operation & User’s Manual

Amprobe AT-7000 Manual Online:

3.7, 722 votes
Amprobe AT-7000 User Manual
Amprobe AT-7000 User Guide
Amprobe AT-7000 Online Manual

Text of Amprobe AT-7000 User Guide:

  • Amprobe AT-7000, 27 Figure 4.10b Figure 4.10c 7. PRESS ENTER when complete to return to home screen. *Note: For best results, keep the receiver at least 3 feet from the transmitter and its test leads to minimize signal interference and improve wire tracing results. 4.11 Locating Loads (Signal Clamp) The clamp accessory can be used to map loads to specific breakers on both energized and de-energized systems. There is no need to disconnect power. 1. Clamp the SC-7000 around the wire at the breaker panel. 2. Set up the transmitter and receiver as described

  • Amprobe AT-7000, 12 3.1 Tracing Energized Wires SMART SENSOR The SMART SENSOR enables easier wire tracing by showing the direction and position of the wire and is the recommended method for tracing energized wires (does not work on de-energized circuits, use de-energized TIP SENSOR for that application). Connecting transmitter test leads 1. Connect green and red test leads to the transmitter (polarity does not matter) 2. . Connect red lead to energized hot wire (on the load side of the system). The signal will ONLY be transmitted between the outlet to which the transmitter is connected and the source of power (see Figure 3a). 3. Connect green wire

  • Amprobe AT-7000, 4 Symbols used in this product Battery status – Displays the remaining battery charge Home – Return to home screen when selected Help – Enters to the help mode when selected Settings – Enters to the settings menu when selected Volume– Displays the volume in four levels Sensitivity indicator – Displays the sensitivity level from 1 to 10. Icon indicating energized system Icon indicating de-energized system 99 SIGNAL Signal strength indicator – Shows the strength of the signal from 0 to 99 MAN/AUTO Shows whether the sensitivity adjustment is in Manual or Automat

  • Amprobe AT-7000, AT-7000 Advanced Wire Tracer AT-7020 AT-7030 User Manual 10/2017, 4394127 Rev B ©2017 Amprobe Test Tools. All rights reserved. English www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

  • 25 4.7 Tracing Underground Wires The AT-7000 can trace wires underground, the same way it can locate wires behind walls or floors. Perform tracing as described in Energized SMART SENSOR mode or Energized / De-Energized TIP SENSOR modes. You can use a hot sick attachment to make tracing more ergonomic and convenient. Connect the transmitter as shown in the diagram. AT-70

  • Amprobe AT-7000, 11 • �IMPORTANT NOTICE, PLEASE READ BEFORE YOU START TRACING Avoiding signal cancellation problems with a separate ground connection The signal generated by the transmitter creates an electromagnetic field around the wire. This field is what is detectable by the receiver. The clearer this signal, the easier it is to trace the wire. If transmitter is connected to two adjacent wires on the same circuit (for example, hot and neutral wires on a Romax cable), the signal travels in one directions through the first wire and then returns (with opposite direction) through the second one. This causes creation of two electromag

  • 21 4. Step 2 - 2 LOCATE a) Select LOCATE mode by using the directional arrows to highlight this operating mode and pressing the yellow “ENTER” button. b) Scan each breaker again for a half second each by touching it with the Tip Sensor. Active red arrow indicates scanning process. Make sure the groove on the Tip Sensor is parallel to the breaker leng

  • Amprobe AT-7000, 13 Using AT-7000-R Receiver 1. Press ‘ON/OFF’ push button to turn on the receiver and wait for the home screen (boot up time is around 30 seconds). 2. Select SMART SENSOR mode by using the directional arrows to highlight this operating mode and pressing the yellow ENTER button. 3. Hold the receiver with the Smart Sensor on the rear of the unit facing the target area. If the screen flashes a “?” in a red target then no signal is detected. Move the Smart Sensor closer to the target area until the signal is detected and you see a directional arrow. If no signal is detected increase the sensitivity using the “+” button on the receiver. (see Figure 3

  • Amprobe AT-7000, 19 Step 1 - 1 SCAN: 1. The unit will automatically start in 1 SCAN mode as shown in Figure 3.3b. 2. Scan each breaker for a half second by touching it with the Tip Sensor. Make sure the groove on the Tip Sensor is parallel to the breaker lengthwise (See Figure 3.3d) 3. To assure sufficient time between the scans, wait for active green arrow and audible alert (2-beeps) before moving to the next breaker. 4. Scan all breakers – the order of scanning does not matter. You can scan breakers multiple times. The recei

  • Amprobe AT-7000, 5 This manual contains information and warnings that must be followed for operating the tester safely and maintaining the tester in a safe operating condition. If the tester is used in a manner not specified by the manufacturer, the protection provided by the tester may be impaired. This tester meets water and dust protection IP40 per IEC60529 Ed 2.1 (2001). Do not use in rainfall! The tester is double insulated for protection per EN61010-1:2010 3rd Ed to CAT IV 600V. (AT-7000-R) and CAT IV 300V MAX (AT-7000-T) CAUTION: Do not connect the Transmitter to a separate ground in

  • Amprobe AT-7000, 26 4.10 No Access to Bare Conductors (Signal Clamp) The clamp accessory is used for applications where there is no access to the bare conductor to connect transmitter test leads. When clamp is connected to the transmitter, it enables the AT-7000-T to induce signal to energized or de-energized wire through the insulation. The signal will travel through the wire both directions and it will affect all the branches. This method is safe to use for any sensitive electronic equipment. Connect the clamp 1. Connect the

  • Amprobe AT-7000, 1 AT-7000 Series CONTENTS 1. PRECAUTIONS AND SAFETY MEASURES ............................................................. 2 2. KIT COMPONENTS ................................................................................................. 5 2.1 AT-7000-R Receiver ........................................................................................................6 2.2 AT-7000-T Transmitter ...................................................................................................8 2.3 TL-7000 Test Lead & Accessory Kit ................................................................................9 2.4 SC-7000 Signal Clamp (AT-7030 Kit) ..................

  • Amprobe AT-7000, 28 5. MAINTENANCE Changing battery for transmitter: The battery compartment on the back of the AT-7000-T is designed to make it easy for the user to change the battery. A screw is added to secure the battery in case the unit is dropped. 6 AA rechargeable batteries or 6 AA alkaline batteries may be used. 6 x AA batteries Screws Battery Cover 1. Make sure that the Transmitter is turned off. 2. Use the star screw driver to unscrew the holding screws. 3. Remove the battery cover. 4. Install Batteries using the battery clip. 5. Replace the battery cover and secure it with the provided screw. www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

  • 7 ENERGIZED: DE-ENERGIZED: -- Main applications Setting menu Help guide Buzzer volume adjustment Sensitivity adjustment Figure 1a: Overview of all elements on home screen Home menu Figure 1b: Overview of all elements on the setting menu Language English, French, German, Spanish, Italian Backlight 25%, 50%, 75%, 100% Setting DEFAULT : Restore default set

  • 14 3.1 Tracing Energized Wires TIP SENSOR TIP SENSOR mode is used for the following applications: pinpointing a wire in a bundle, tracing in corners and confined spaces such as junction boxes or inside enclosures. Connecting transmitter test leads 1. Connect green and red test leads to the transmitter (polarity does not matter) 2. Connect red lead to energized hot wire (on the load side

  • Amprobe AT-7000, 17 Using AT-7000-R Receiver 1. Press ‘ON/OFF’ push button to turn on the receiver and wait for the home screen (boot up time is around 30 seconds). 2. Select De-Energized TIP SENSOR mode by using the directional arrows to highlight this operating mode and pressing the yellow “ENTER” button. Screen will appear as shown in Figure 3.2c 3. Hold the receiver with the Tip Sensor facing the target area.* 4. Scan target area with Tip Sensor to find highest signal level. While tracing, periodically adjust sensitivity to keep signal strength near 75. Increase or decrease sensitivity by pressing + or – on the keypad. If si

  • Amprobe AT-7000, 29 Changing receiver battery: The battery compartment on the back of the AT-7000-R is designed to make changing batteries easy. Four (4) AA 1.5V alkaline or 1.2V rechargeable batteries may be used. 4 x AA batteries Screws Battery Cover Figure 5.2: Changing receiver battery 1. Make sure that the Receiver is turned off. 2. Use screw driver to unscrew the captive screw. 3. Remove the battery cover. 4. Install batteries using the battery clip. 5. Replace the battery cover and secure it with the provided screw. 5. MAINTENANCE www.GlobalTestSupply.com Find Quality Products Online at: [email protected]

  • Amprobe AT-7000, 31 6. SPECIFICATIONS AT-7000-R AT-7000-T SC-7000 LCD size 3.5" 1.77" NA LCD Dimensions 2.76 x 2.07 1.1 x 1.38 in NA LCD Resolution (pixels) 320 x 240 128 x 160 NA LCD type TFT RGB x TFT NA Color LCD Yes Yes NA Backlight Yes Yes NA mDDR 64 MB 64 MB NA FLASH memory 128 MB 128 MB NA Audio 95 dB No NA Operating Temperature range 0 to 120F (-17.77C to 49C) 0°F to 120°F (-17.77°C to 49°C) 0°F to 120°F (-17.77°C to 49°C) Storage Temperature (-40 to 150F) (-40 to 65.5C) -40°F to 150°F (-40°C to 65.5°C) -40°F to 150°F (-40°C to 65.5°C) Operating Humidity 95% R.H max 95% R.H max 95% R.H max Operati

  • Amprobe AT-7000, 16 3.2 Tracing De-energized Wires TIP SENSOR De-energized TIP SENSOR mode is used for general wire tracing, pinpointing wires in bundles, tracing in tight corners and confined spaces such as junction boxes or inside enclosures. Connecting transmitter test leads 1. Connect green and red test leads to the transmitter (polarity does not matter) 2. Connect red lead to de-energized hot wire (on the load side of the system). In de-energized mode the signal will be injected to ALL branches of the circuit, not just between the outlet and the

  • Amprobe AT-7000, 3 �Warnings: Read Before Using To avoid possible electric shock or personal injury: • Use the Meter only as specified in this manual or the protection provided by the instrument might be impaired. • Avoid working alone so assistance can be rendered. • Never measure ac current while the test leads are inserted into the input jacks. • Do not use the Meter in wet or damp environments. • Do not use the Meter if it appears damaged. Inspect the Meter before use. Look for cracks or missing plastic. Pay particular attention to the insulation around the connectors. • Inspect the test leads be

More Instructions:

DOWNLOAD

Related Products and Documents (GPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Foxconn MARS Operation & user’s manual foxconn/mars-YDL.pdf 08 Apr 2023 110 2.33 Mb
2 Crate GX-60C Owner's manual crate/gx-60c-1M2.pdf 08 Aug 2022 4 2.06 Mb
3 Elo TouchSystems ET1525C Operation & user’s manual elo-touchsystems/et1525c-635.pdf 02 Nov 2023 48 0.36 Mb
4 RCA DRC300iH Information sheet rca/drc300ih-BZP.pdf 02 May 2023 1 0.11 Mb
5 Toastmaster TBR20H Use and care manual toastmaster/tbr20h-F1B.pdf 20 Dec 2022 64 0.94 Mb
6 OPTICOM SR5800D-8 Datasheet opticom/sr5800d-8-24R.pdf 30 Oct 2022 2

Similar Resources:

  • LITE-In

    LGSF3000

    (9 pages)
    Bluetooth GPS Receiver GSF3000 Directory LGSF3000 Bluetooth GPS Receiver Express Directory 7. 7, 2006 V1.0 LITE-In Tech. Co., Ltd., 4F, No. 20, Lane 50, Sec. 3, Nangang Rd., Taipei 115, Taiwan, R.O.C. Phone:+886-2-2786-3636 Fax:+886-2-2783-0909 E-Mail:[email protected] Web:http: …
  • gtt systems

    GTTS-2000B

    (2 pages)
    GTTSystems B.V. Herfordstraat 16 7418 EX Deventer T 0570 605075 F 0570 677755 E [email protected] W www.gtts.eu Brief Installation Manual GTTS-2000B V1.3 GTTS-2000B Iridium Global Tracking & Tracing System Prior to mechanical installation the GTTS unit shall be activated in the Iridium Satellite Network. Send an email to [email protected] with …
  • Garmin

    GPSMAP230

    (2 pages)
    GPSMAP 230The Home Theatre Of GPS ChartplottingThe new GARMIN GPSMAP 230 offers boaters advanced GPSperformance on a 7.1" diagonal, track up display that’s sure to setthe standard for big-screen chartplotting. Add in simple, menu-driven operation, G-chart cartography with seamless Navionicscharts, and a powerful, 12 parallel channel GPS receiver, and …
  • Holux

    GM-210

    (14 pages)
    GPS Receiver May. 28, 2003 HOLUX Technology,.Inc 8F-11, 26, Tai Yuen St., Chu Pei, Hsin Chu, Taiwan Phone: +886-3-5526268 Fax: +886-3-5526108 E-Mail: [email protected] Web: www.holux.com.tw All Right Reserved User’s Guide GM-210 HOLUX …
  • Lantronix

    FOX3-3G-DR

    (10 pages)
    Application Note Improving Asset Tracking Through Untethered Dead Reckoning with FOX3-3G-DR Part Number APP-0008 Revision A October 2019 …
  • Edgetech

    USBL BROADBAND ACOUSTIC TRACKING SYSTEM

    (102 pages)
    EdgeTech 4 Little Brook Road West Wareham, MA 02576 Tel: (508) 291-0057 Fax: (508) 291-2491 www.EdgeTech.com USBL BROADBAND ACOUSTIC TRACKING SYSTEM (BATS) USER HARDWARE MANUAL 0018257_REV_A November 2017 …

Comments, Questions and Opinions: