  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 5 Model(Single) AOU-1800VRDC3A AOU-1845VRDC3A AOU-1908VRDC3A AOU-1962VRDC3A Model(Combined) AOU-560VRDC3A + AOU-615VRDC3A + AOU-615VRDC3A AOU-615VRDC3A +AOU-615VRDC3A +AOU-615VRDC3A AOU-280VRDC3A +AOU-450VRDC3A +AOU-560VRDC3A +AOU-615VRDC3A AOU-280VRDC3A +AOU-504VRDC3A +AOU-560VRDC3A +AOU-615VRDC3A Model(Single) AOU-2016VRDC3A AOU-2072VRDC3A AOU-2028VRDC3A AOU-2184VRDC3A Model(Combined) AOU-280VRDC3A +AOU-560VRDC3A +AOU-560VRDC3A +AOU-615VRDC3A AOU-280VRDC3A +AOU-560VRDC3A +AOU-615VRDC3A +AOU-615V

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 43 4.6.4 Communication address Auto addressing technology is adopted for AOU IDU and ODU. No need to set address codes manually. Only the addresses of master unit and central control are needed to be set (address of central control is only needed when there are multiple refrigeration systems). Note: When installing remote monitor or central controller, displacement on indoor units’ project codes must be made. Otherwise, there will be collision malfunction of the project codes. For detail operation methods, please refer to the AOU Installation and Maintenance M

  • DC Inverter VRF 44 Fig. 4.7.2 Connection of modular units Note: ① For modular outdoor units, if there are multiple outdoor modules, then the master unit must be the first outdoor module on the communication wire and should not connect with IDU (master unit is set by SA8 of the outdoor main board). ② For modular outdoor units, if there are multiple outdoor modules, then indoo

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 20 Outdoor Model Gas pipe size(mm) Liquid pipe size(mm) AOU-960VRDC3A Φ38.1 Φ22.2 AOU-1010VRDC3A Φ41.3 Φ22.2 AOU-1065VRDC3A Φ41.3 Φ22.2 AOU-1130VRDC3A Φ41.3 Φ22.2 AOU-1180VRDC3A Φ41.3 Φ22.2 AOU-1235VRDC3A Φ41.3 Φ22.2 AOU-1300VRDC3A Φ41.3 Φ22.2 AOU-1350VRDC3A Φ41.3 Φ22.2 AOU-1410VRDC3A Φ44.5 Φ22.2 AOU-1460VRDC3A Φ44.5 Φ22.2 AOU-1515VRDC3A Φ44.5 Φ22.2 AOU-1580VRDC3A Φ44.5 Φ22.2 AOU-1630VRDC3A Φ44.5 Φ22.2 AOU-1685VRDC3A Φ44.5 Φ22.2 AOU-1750VRDC3A Φ44.5 Φ22.2 AOU-1800VRDC3A Φ44.5 Φ22.2 AOU-1845VRDC3A Φ44.5 Φ22.2 AOU-1908VRDC3A Φ51.4 Φ25.4

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 13 ( 2 ) Anti-monsoon installation requirements for unit connecting exhaust duct: Fig. 3.2.10 3.2.5 Take snow into consideration when installing the outdoor unit Fig. 3.2.11 3.3 Piping Work Requirements Refer to the table below for piping work requirements. R410A Refrigerant System Outer Diameter (mm) Wall Thickness (mm) Type Φ6.35 ≥ 0.8 0 Φ9.52 ≥ 0.8 0 Φ12.70 ≥ 0.8 0 Φ15.9 ≥ 1.0 0 Φ19.05 ≥ 1.0 1/2H Φ22.2 ≥ 1.5 1/2H Φ25.40 ≥ 1.5 1/2H Φ28.60 ≥ 1.5 1/2

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 31 Fig. 4.3.7 (5) Thermal insulation for pipeline 1) To avoid condensate or water leakage on connecting pipe, the gas pipe and liquid pipe must be wrapped with thermal insulating material and adhesive pipe for insulation from the air. 2) For heat pump unit, liquid pipe should bear 70 ℃ or above, and gas pipe should bear 120 ℃ or above. For cooling only unit,both liquid pipe and gas pipe should bear 70 ℃ or above. Example: Polyethylene foam can bear 120 ℃ above and f

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 24 Basic Module(single module) Pipe between ODU and the first branch of IDU Gas Pipe(mm) Liquid Pipe(mm) AOU-224VRDC3A Φ19.05 Φ9.52 AOU280VRDC3A Φ22.2 Φ9.52 AOU-335VRDC3A Φ25.4 Φ12.7 AOU-400VRDC3A Φ25.4 Φ12.7 AOU-450VRDC3A Φ28.6 Φ12.7 AOU-504VRDC3A Φ28.6 Φ15.9 AOU-560VRDC3A Φ28.6 Φ15.9 AOU-615VRDC3A Φ28.6 Φ15.9 For multiple modules, the piping from ODU to the first branch of IDU is based on the total rated capacity of outdoor modules. Fig. 4.2.12 Total rated capacity of outdoor modules (multi-modular system) Pipe between OD

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 4 2.1 Names of Main Parts Fig. 2.1.1 NO. ① ② ③ ④ ⑤ Name Fan, Motor Electric Box Assembly Valve interface Power cord through-hole Communication code through-hole Note: The picture is only used for reference and the actual product prevails. 2.2 Combinations of Outdoor Units Model(Single) AOU-680VRDC3A AOU-730VRDC3A AOU-785VRDC3A AOU-850VRDC3A Model(Combined) AOU-280VRDC3A + AOU-400VRDC3A AOU-280VRDC3A + AOU-450VRDC3A AOU-280VRDC3A + AOU-504VRDC3A AOU-280VRDC3A + AOU-560VRDC3A Model(Single) AOU-900VRDC3A AOU-960VRDC3A AOU-101

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 29 Fig. 4.3.2(b) (2) Manifold has serveral pipe sections with different pipe size, which facilitates to match with various copper pipe. Use pipe cutter to cut in the middle of the pipe section with different pipe size and deburr as well. See Fig. 4.3.3. Fig. 4.3.3 (3) Y-type manifold can be installed vertically or horizontally. Confirm the position and then weld the manifold pipe. See the Fig. 4.3.4(a). T-type manifold must be installed horizontally with inclination, see the Fig. 4.3.4(b). Fig. 4.3.4(a) Fig. 4.3.4

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 50 Check Items Conditions Might Happen Check Has the pipe length and refrigerant charging amount been recorded? The refrigerant charging amount is not accurate. Is the address code of outdoor modules correct? The unit can not run normally. Communication malfunction might happen. Is the address code of indoor units and wired controller correct? The unit can not run normally. Communication malfunction might happen. Has the communication line been connected correct? The unit can not run normally. Communication malfunction might h

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 54 Description of each stage of debugging progress —— Debugging code Progress code Status code Meaning progress LED1 LED2 LED3 Code Display status code Display status Code Display status 16_Heating debugging db light 16 light AH light Debugging is enabled in heating mode (debugging mode, auto-selected by system). db light 16 light Error code light Error occurs during debugging in heating mode. db light 16 light J0 light Error of other modules occurs during debugging in heating mode. db light 16 light U9 light Ou

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 39 Wiring method for the power cord of AOU-504VRDC3A, AOU-560VRDC3A and AOU-615VRDC3A Fig. 4.5.3 4.6 System Communication 4.6.1 Communication system include: (1) Communication among outdoor basic modules; (2) Communication between ODU and IDU; (3) Communication among IDUs; (4) Communication between IDU and wired controller; (5) Connection between IDU and light board receiver; (6) Communication between different refrigeration systems; (7) Graphics of general communication connection

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 46 When two wired controllers control multiple IDUs, the wired controller can be connected to any one IDU, provided that the connected IDU is of the same series. Meanwhile, one and only one of the wired controllers must be set as a slave controller. At most 16 IDUs can be controlled by wired controllers and the connected IDUs shall be within a same IDU network. No matter when unit is turned on or off, slave controller can be set. How to set a slave controller: hold “function” button on the designated controller for 5s, and tempera

  • DC Inverter VRF 27 Total capacity of downstream indoor unit(s) C(kW) Dimension of the pipe of indoor branch Gas Pipe(mm) Liquid Pipe (mm) C ≤ 5.0 Φ12.7 Φ6.35 5.0 < C ≤ 14.2 Φ15.9 Φ9.52 14.2 < C ≤ 22.4 Φ19.05 Φ9.52 22.4 < C ≤ 28.0 Φ22.2 Φ9.52 28.0 < C ≤ 40.0 Φ25.4 Φ12.7 40.0 < C ≤ 45.0 Φ28.6 Φ12.7

  • DC Inverter VRF 14 4 Installation Instruction 4.1 Physical Dimension of the Outdoor Unit and Mounting Hole Outline and Physical Dimention of AOU-224VRDC3A and AOU-280VRDC3A unit Unit: mm Fig. 4.1.1

  • DC Inverter VRF 2 Never fail to comply with the nitrigen charge requirements.Charge nitrogen when welding pipes. Never short-circiut or cancel the pressure switch to prevent unit damage. Please firstly connect the wired controller before energization, otherwise wired controller can not be used. Before using the unit, please check if the piping and wiring are corre

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 49 4.8.2 External wiring diagram of modular connection Fig. 4.8.2 Note: maximum number of ODU (N) and maximum number of IDU (n) are based upon the combination type of ODU. For details, please refer to the introduction of units’ combination. 5 Check Items after Installation and Trial Run 5.1 Check Items after Installation Check Items Conditions Might Happen Check Has the unit been fixed firmly? The unit may drop, shake or emit noise. Have you done the gas leakage

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 42 Fig. 4.6.5 Fig. 4.6.6 (2) All communication wires of AOU are connected by screws. Fig. 4.6.7 (3) If a single communication wire is not long enough and needs to be connected, the connected joint must be welded or pressure-welded. Do not simply twist the wires together.

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 65 7 Error Indication Inquiry method of malfunction display: combine division number and content number to check the corresponding malfunction. Indoor: Error Code Content Error Code Content L0 Malfunction of IDU d2 Malfunction of lower water temperature sensor of water tank L1 Protection of indoor fan d3 Malfunction of ambient temperature sensor L2 Auxiliary heating protection d4 Malfunction of entry-tube temperature sensor L3 W

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 25 Total rated capacity of outdoor modules (multi-modular system) Pipe between ODU and the first branch of IDU Gas Pipe(mm) Liquid Pipe(mm) AOU-1350VRDC3A Ф38.1 Ф19.05 AOU-1410VRDC3A Ф41.3 Ф19.05 AOU-1460VRDC3A Ф41.3 Ф19.05 AOU-1515VRDC3A Ф41.3 Ф19.05 AOU-1580VRDC3A Ф41.3 Ф19.05 AOU-1630VRDC3A Ф41.3 Ф19.05 AOU-1685VRDC3A Ф41.3 Ф19.05 AOU-1750VRDC3A Ф41.3 Ф19.05 AOU-1800VRDC3A Ф41.3 Ф19.05 AOU-1845VRDC3A Ф41.3 Ф19.05 AOU-1908VRDC3A Ф44.5 Ф22.2 AOU-1962VRDC3A Ф44.5 Ф22.2 AOU-2016VRDC3A Ф44.5 Ф22.2 AOU-2072VRDC3A Ф44.5 Ф22.2 AOU-2128VRDC3A Ф44.5 Ф22.2 AOU-2184V

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 47 Note: ① Wired controller and light board remote receiver can be used at the same time. ② When light board remote receiver is used, please use remote controller at the same time. 4.7.4 Communication connection of central controlling units Note:The centralized controller can be installed when it is necessary. Port connection G1 and G2 on the wiring board XT2 of master unit among each multi VRF system (see below) Fig. 4.7.8

  • AlpicAir DC Inverter Multi VRF System, DC Inverter VRF 12 3.2.4 Take seasonal wind into consideration when installing the outdoor unit ( 1 ) Anti-monsoon installation requirements for unit not connecting exhaust duct: Fig. 3.2.9

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Garmin GPS III Owner's manual garmin/gps-iii-3F1.pdf 08 Dec 2023 63 0.71 Mb
2 Zte MF190A Quick start manual zte/mf190a-2SN.pdf 30 Nov 2022 2
3 Volvo S60 - ANNEXE 931 Wiring diagram volvo/s60-annexe-931-941.pdf 15 Jul 2023 242 25.8 Mb
4 Sony CCD-TRV107E Operating instructions manual sony/ccd-trv107e-O65.pdf 24 Aug 2022 132 2.62 Mb
5 Singer 20U43 Parts list singer/20u43-47F.pdf 16 Oct 2022 8 0.46 Mb
6 TRENDnet TEW-222CF Operation & user’s manual trendnet/tew-222cf-S48.pdf 26 Feb 2024 53 1.34 Mb

Similar Resources:

  • Mitsubishi Electric

    MXZ-3A54VA

    (100 pages)
    РусскийINSTALLATION MANUALFOR INSTALLERCONTENTS1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FORSAFETY ........................................................................................... 22. INSTALLATION DIAGRAM & ACCESSORIES ................................ 23. SELECTING THE INSTALLATION LOCATION ................................ 34. OUTDOOR …
  • Haier

    HSU-09LH13

    (8 pages)
    No.001050Installation Manual of Room Air ConditionerRead this manual before installation1.Driver2.Hacksaw3.Hole core drill4.Spanner(17,19 and 26mm)5.Torque wrench(17mm,22mm,26mm)6.Pipe cutter7.Flaring tool8.Knife9.Nipper 12.Reamer10.Gas leakage detector or soap-and-water solution11.Measuring tapeExplain sufficiently the operating means to the useraccordi …
  • innovair

    Inverter FLEX24 SEV2040H2R18

    (121 pages)
    FLEX24HEAT PUMP SPLIT SYSTEMSERVICE MANUAL• The information contained in the manual is intended for use by a qualified service technicianfamiliar with safety procedures and equipped with the proper tools and test instruments• Installation or repairs made by unqualified persons can result in hazards to you and others.• Failure to carefully read and foll …
  • Venmar

    41502

    (18 pages)
    VB0069VB0074These products earned the ENERGY STAR® by meeting strict energy efficiency guidelines set by Natural Resources Canada and the US EPA. They meet ENERGY STAR requirements only when used in Canada.06010A rev. 17INSTALLATION GUIDE FORVENMAR AVS UNITSCONSTRUCTO 1.0 HRV AND CONSTRUCTO 1.0 ERVModel no.: 41502 (HRV with top ports)Model no.: 41500 (HRV w …
  • Samsung

    AS09W8WE/XAP

    (24 pages)
    E§§HNIKAENGLISHOWNER’S INSTRUCTIONSMANUAL DE INSTRUCCIONESMANUEL D’UTILISATIONISTRUZIONI PER L’USOMANUAL DE INSTRUÇÕESGEBRAUCHSANWEISUNG√¢∏°π∂™ Ã∏™∆∏Split-type Room Air Conditioner (Cool)Aire acondicionado doméstico sistema Split (Refrigeración)Climatiseur de type Séparé (Refroidissement)Condizionatore d’aria per ambient …
  • Carrier

    24ACB3

    (34 pages)
    24ACB3Comfortt13 Series Air Conditionerwith Puronr Refrigerant1---1/2 To 5 Nominal Tons (Size 18 To 60)Product Datathe environmentally sound refrigerantCarrier ’s Air C o n d itioners with P u ro n r refrigerant provide acollection of features unmatched by any other family of equipment.Th e 24 AC B has b een d esign ed u tilizing Carrier ’s Puro nrefrige …

Comments, Questions and Opinions: