  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 18 4.5.2 Installing the Drain Pipes (1). For determining the position of the drain hose, perform the following procedures. (2). Insert the drain pipe to the drain outlet of the unit and then tighten the clamp securely with tape. (Fig.4.21) (3). Connect the extension drain pipe to the drain pipe and then tighten the clamp with tape. 1 2 3 1 2 Drain pan Seal Drain hose ≤ 4mm Fig.4.21 Fig.4.22 Fig.4.23 Tighten the clamp until the sc

  • DC Inverter U-match Series Floor Ceiling Type Unit 20 4). Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal screw using a screwdriver. (2). For strand wiring (Fig.4.26) 1). Cut the wire end with a wire cutter or wire-cutting pliers, then strip the insulation about 25 mm (15/16")  . 2). Using a screwdriver, remove th

  • DC Inverter U-match Series Floor Ceiling Type Unit 19 Ceiling type Floor type Fig.4.25 4.6 Electrical Wiring 4.6.1 Wiring Precautions WARNING ! ① . Before obtaining access to terminals, all supply circuits must be disconnected. ② . The rated voltage of the unit is as shown as Table 3.4 and Table 3.5. ③ . Before turning on, verify that the voltage is within the 198~

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 4 3.2 Selection of the Installation Location WARNING! The unit must be installed where strong enough to withstand the weight of the unit and xed securely, otherwise the unit would topple or fall off. CAUTION! ① . Do not install where there is a danger of combustible gas leakage. ② . Do not install the unit near heat source, steam, or ammable gas. ③ . Children under 10 years old must be supervised not to operate the unit. Decide the installation location with the customer as follows: 3.2.1 Indoor Unit (1). Install the unit at a place where is strong enough to withstand the weight of the u

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 6 3.3 Connection Pipe Requirement CAUTION! The maximum length of the connection pipe is listed in the table below. Do not place the units between which the distance exceeds the maximum length of the connection pipe. Table 3.3 Size of Fitting Pipe(Inch) Max. Pipe Length (m) Max. Height Difference between Indoor Unit and Outdoor Unit (m) Drainage pipe(Outer Diameter × wall thickness) (mm) Liquid Gas 1/4 1/2 20 15 φ17×1.75 3/8 5/8 30 15 φ17×1.75 3/8 5/8 30 15 φ17×1.75 3/8 5/8 50 30 φ1

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 27 2. Clean the ler screen Clean the filer screen by a vacuum cleaner or wash it by ashing water. If the oil stain on the lter can not be removed or cleaned up, wash it by warm water meld with the detergent. Dry the filer in the shadow. Note: ① . Never use hot water over 45°C in case of color fading or turning yellow. ② . Never dry it by fire so as to prevent the filter caught re or deformation. 3. Disassemble the left and right side board ① . After the grille is removed, use a screwdriver to remove the screws shown on the picture. ② . Push the side plat

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 10 ◆ Ceiling type 40 Ceiling Suspension bolt Spring washer Nut Nut Hanger Right side panel Left side panel Fig.4.4 (6). Adjust the height of the unit to make the drain pipe slant slightly downward so that the drainage will become much smoother. 4.1.4 Leveling The water level test must be done after installing the indoor unit to make the unit is horizontal, as shown below. Horizontal tester Fig.4.5 4.2 Installation of the Outdoor Unit WARNING ① . Install the unit where it will not be tilted by more than 5°. ② . During installation, if the outdoor unit has to be exposed to strong wind, it must be xed securely.

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 23 Power lines should go along the right side plate and be fixed to the fixation hook with binding wires to keep no contact with pipelines. Communication lines between indoor and outdoor units also should go along the right side plate and keep away from power lines. Routing of External Power Lines Fig.4.32 5 Installation of Controllers Refer to the Installation Manual of the controller for more details. 6 Test Running 6.1 Trial Operation and Testing (1). The meaning of error codes as shown below: Table 6.1 Number Error code Error Remarks 1 E1 Compressor high p

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 13 4.3.3 Connecting the Pipe at the Indoor Unit Side Detach the caps and plugs from the pipes. CAUTION! ① . Be sure to apply the pipe against the port on the indoor unit correctly. If the centering is improper, the flare nut cannot be tightened smoothly. If the flare nut is forced to turn, the threads will be damaged. ② . Do not remove the are nut until the connection pipe is to be connected so as to prevent dust and impurities from coming into the pipe system. When connecting the pipe to

  • Air-Con ASKCI4H4R18, 1 Safety Precautions ..........................................................................................1 2 Outline of the Unit and Main Parts ...................................................................2 3 Preparative for Installation ...............................................................................3 3.1 Standard Accessory Parts ..........................................................................3 3.2 Selection of the Installation Location ..........................................................4 3.3

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 8 4 Installation of the Unit 4.1 Installation of the Indoor Unit 4.1.1 Indoor unit dimension WARNING ! ① . Install the indoor unit in a location which can withstand a load of at least ve times the weight of the main unit and which will not amplify sound or vibration. ② . If the installation location is not strong enough, the indoor unit may fall and cause injuries. ③ . If the job is done with the panel frame only, there is a risk that the u

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 7 accessible. ③ . The specications of the breaker and power cable listed in the table above are determined based on the maximum power (maximum amps) of the unit. ④ . The specifications of the power cable listed in the table above are applied to the conduit- guarded multi-wire copper cable (like, YJV copper cable, consisting of PE insulated wires and a PVC cable jacket) used at 40°С and resistible to 90°С(see IEC 60364-5-52). If the working condition changes, they should be modied according to the related national standard. ⑤ . The specifications o

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 17 an oil bend should be employed for every 6 meters. Oil bend Oil bend Indoor Outdoor 6m Fig.4.18 4.5 Installation of the Drain Pipe 4.5.1 Precautions When Doing the Piping Work (1). Keep piping as short as possible and slope it downwards at a gradient of at least 1/100 so that air may not remain trapped inside the pipe. (2). Keep pipe size equal to or greater than that of the connecting pipe. (3). Install the drain piping as shown and take measures against condensation. Improperly rigged piping could lead to leaks and eventually wet furnitur

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 1 1 Safety Precautions WARNING! This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user. CAUTION! This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user, or damage to property. WARNING! (1). For operating the air conditioner pleasantly, install it as outlined in this installation manual. (2). Connect the indoor unit and outdoor unit with the room air conditioner piping and cord available from our standard parts. This installation manual describes the correct connections using the installation set a

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 21 (4). Electric wiring between the indoor and outdoor units Single-phase units(18/24/36/48K) ASKCI4H4R18 + ASKEL4H4R18 ① . Power cord 3×1.5mm 2 (H07RN-F) ② . Power cord 3×1.0mm 2 (H05RN-F) ③ . Communication Cords 2×0.75mm 2 (H05RN-F) ASKCI4H4R24 + ASKEL4H4R24 ASKCI4H4R36 + ASKEL4H4R36 ① . Power cord 3×2.5mm 2 (H07RN-F) ② . Power cord 3×1.0mm 2 (H05RN-F) ③ . Communication Cords 2×0.75mm 2 (H05RN-F) ASKCI4H4R48 + ASKEL4H4R48 ① . Power cord 3×6.0mm 2 (H07RN-F) ② . Power cord 3×1.0mm 2 (H05RN-F) ③ . Communication Cords 2×0.75mm 2 (H05RN-F) Fig.4.29 (

  • DC Inverter U-match Series Floor Ceiling Type Unit 22 CAUTION! ① . The power cord and the wire of the fresh air valve are high-voltage, while the communication cord and connection wire of the wired controller are low-voltage. They should run separately against electromagnetic interference. ② . The high-voltage and low-voltage lines should pass through t

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 3 3 Preparative for Installation 3.1 Standard Accessory Parts The standard accessory parts listed below are furnished and should be used as required. Table 3.1 Indoor Unit Accessories No. Name Appearance Q'ty Usage 1 Nut with Washer 8 To x the hook on the cabinet of the unit. 2 Wireless Controller+Battery 1+2 To control the indoor unit 3 Insulation 1 To insulate the gas pipe 4 Insulation 1 To insulate the liquid pipe 5 Installation Paperboard

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 25 6.2 Working Temperature Range Table 6.2 Test Condition Indoor Side Outdoor Side DB(°C) WB(°C) DB(°C) WB(°C) Nominal Cooling 27 19 35 24 Nominal Heating 20 − 7 6 Rated Cooling 32 23 48 − Low Temp. Cooling 21 15 -15 − Rated Heating 27 − 24 18 Low Temp. Heating 20 − -10 -11 Note: ① . The design of this unit conforms to the requirements of EN14511 standard. ② . The air volume is measured at the relevant standard external static pressure. ③ . Cooling (he

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 15 4.3.7Liquid Pipe and Drain Pipe Sealed Drain pipe Saddle Fig.4.15 Fig.4.16 Trap If the outdoor unit is installed lower than the indoor unit (See Fig.4.15) (1). A drain pipe should be above ground and the end of the pipe does not dip into water. All pipes must be restrained to the wall by saddles. (2). Taping pipes must be done from bottom to top. (3). All pipes are bound together by tape and restrained to wall by saddles. If the outdoor unit is installed higher than the indoor unit (1). Taping should be done from lowe

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 9 4.1.3 Indoor Unit Installation (1). Determine the location of the hanger through the paper template, and then remove the paper template. Paper template Anchor bolt Fig.4.2 (2). Insert the anchor bolts into the drilled holes, and drive the pins completely into the anchor bolts with a hammer. (3). Remove the right and left side panels. (4). Put the hanger bolt into the clasp of the indoor unit and tighten screws on the hanger to prevent the indoor unit from moving. (5). Reinstall and tighten the right and left side p

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 14 Table 4.3 Flare nut tightening torque Pipe Diameter Tightening Torque 1/4˝(Inch) 15-30 (N·m) 3/8˝(Inch) 35-40 (N·m) 5/8˝(Inch) 60-65 (N·m) 1/2˝(Inch) 45-50 (N·m) 3/4˝(Inch) 70-75 (N·m) 7/8˝(Inch) 80-85 (N·m) CAUTION! Be sure to connect the gas pipe after connecting the liquid pipe completely. Fig.4.13 4.3.4 Connecting the Pipe at the Outdoor Side Unit Tighten the are nut of the connection pipe at the outdoor unit valve connector. The tightening method is the same as that as at the indoor side. 4.3.5 Checking the Pipe Connections for Gas Leaking For both indoor and outdoo

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 24 20 H5 IPM protection 21 H6 DC fan motor error 22 H7 Drive desynchronizing protection 23 Hc Pfc protection 25 Lc Activation failure 26 Ld Compressor phase sequence protection 27 LE Compressor stalling protection 28 LF Power protection 29 Lp Indoor and outdoor mismatch 30 U7 4-way valve direction changing protection 31 P0 Drive reset protection 32 P5 Over-current protection 33 P6 Communication error between main control and drive 34 P7 Drive module sensor error 35 P8 Drive module over temperature protection 36 P9 Zero passage protection 37 P

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 26 Poor heating effect ① . The air lter is dirty or blocked. ② . The door or window is not rmly closed. ③ . The set room temperature is too low. ④ . There is refrigerant leakage. ⑤ . The outdoor ambient temperature is lower than -5°C. ⑥ . Control loop is abnormal. Note: After carrying out the check of the above items and taking relevant measures to solve the problems found but the air-conditioning unit still does not function well, please stop the operation of the unit immediately and contact the local service agency designated by AIR-CON. Only ask professional serviceman to check and repair

  • Air-Con ASKCI4H4R18, DC Inverter U-match Series Floor Ceiling Type Unit 5 3.2.2 Outdoor Unit WARNING! ① . Install the unit where it will not be tilted by more than 5°. ② . During installation, if the outdoor unit has to be exposed to strong wind, it must be xed securely. If possible, do not install the unit where it will be exposed to direct sunlight. (If necessary, install a blind that does not interfere with the air ow.) (1). Install the outdoor unit in a place where it will be free from being dirty or getting wet by rain as much as possible. (2). Install the outdoor unit where it is convenient to conn

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ViewSonic PJ400-2 Operation & user’s manual viewsonic/pj400-2-9D3.pdf 15 Sep 2022 60 4.5 Mb
2 Yamaha Pedal Unit LP-7/LP-5 Assembly instructions yamaha/pedal-unit-lp-7-lp-5-M54.pdf 11 May 2023 2 1.64 Mb
3 3Com 6416SW Installation and user manual 3com/6416sw-U7W.pdf 20 Nov 2023 221 1.45 Mb
4 Cal Spas 5100 Owner's manual cal-spas/5100-1OH.pdf 10 Jan 2023 52 6.11 Mb
5 York Survey Supply 343660 Operating instructions york-survey-supply/343660-4M7.pdf 04 Mar 2024 2
6 Polk Audio RM7 Manual  polk-audio/rm7-C85.pdf 23 May 2023 18

Similar Resources:

  • SPT

    WA-1010E

    (18 pages)
    ..... _IWA-iliO!OHi!WA-!Oi!OM i:i :.......::::!i' ::::.......:::: :::: ...................... :::': ::,:, :: :iiimll::: ::: ::::::::::::::::::::::::::::: :::::-::: :: ::::.:''_i!iii!!_iiiii!i_ili:ii:i:ii.ii:!i!i!i,ii:ii,ii,i::i ii_i,i i:,i,i!::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::;.::':::::::: ::::::: …
  • Polar Electro

    Breeze Deluxe

    (6 pages)
    Polar Breeze Deluxe Instruction Manual Thank you for purchasing this unit. Please read these instructions carefully prior to usage. Please keep these instructions safe for future use. IMPORTANT WARNINGS WARNING: When using electrical appliances, basic safety precautions should be followed to reduce the risk of fire, electrical shock and personal injury. 1. …
  • IR Ingersoll Rand

    YSC036E

    (2 pages)
    SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation,starting up, and servicing of heating, ventilating, and air-conditioning equipment canbe hazardous and requires specific knowledge and training. Improperly installed,adjusted or altered equipment by an unqualified person could result in death orserious injury.Wh …
  • Mitsubishi Electric

    MSZ-HR35VF

    (148 pages)
    SPLIT-TYPE AIR CONDITIONERSMSZ-HR25VF MSZ-HR35VF MSZ-HR42VF MSZ-HR50VFINDOOR UNITEnglishOPERATING INSTRUCTIONSBRUKSANVISNINGBETJENINGSVEJLEDNINGINSTRUÇÕES DE OPERAÇÃOΟΔΗΓΙΕΣ ΛΕΙΤΟΥΡΓΙΑΣLIBRETTO D’ISTRUZIONIMANUAL DE INSTRUCCIONESBEDIENINGSINSTRUCTIESNOTICE D’UTILISATIONBEDIENUNGSANLEITUNGРЪКОВОДСТВО ЗА ЕКСПЛОАТ� …
  • Ferroli

    midas pc10

    (112 pages)
    MIDAS PC10 Climatizzatore per ambientiDomestic air conditionerClimatizeur d’ambienceAcondicionador de ambienteGBFINSTALLATION MANUALMANUEL D'INSTALLATION ESMANUAL DEL INSTALADORMANUALE DI INSTALLAZIONEIMod. 12000÷48000 …
  • Panasonic

    CS-N9WKH-8

    (36 pages)
    Operating InstructionsAir ConditionerHướng dẫn sử dụngMáy điều hòa không khí2-17, 34Trước khi bật thiết bị, vui lòng đọc kỹ hướng dẫn sử dụng này và giữ lại để tham khảo cho những lần sau.Bản hướng dẫn lắp đặt đi kèm phải được cất giữ và đọc bởingười lắp đặt trước …

Comments, Questions and Opinions: