  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D en 44 EN FR NL ES IT DE PL RU LOCKING CODES Codes Description of the fault Solution for the fault E 31 Supply Sensor Open: An open circuit has been detected in the appliance supply temperature sensor circuit 1. Check supply temperature sensor, connectors and wiring harness for an open circuit. 2. If necessary replace the sensor, or the wire harness. 3. After  xing the problem reset the appliance and resume normal operation. E 32 DHW Sensor Shorted: A short circuit has been detected in the DHW temperature sensor circuit 1. Check DHW temperature sensor and

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 41 MAINTENANCE Detail of burner components 1. Burner hood 2. Attaching nuts 3. Fan seal with check valve 4. Fan clamp with 1 attachment screw 5. Fan assembly 6. O-ring 7. Venturi 8. Gas valve 9. Gas connection 10. Retaining clip 11. Condensate dish 12. Air inlet 13. Heat exchanger 14. Burner tube 15. Burner hood insulation (not shown) 16. Flame sight glass 17. Electrode assembly 1 2 3 4 5 8 9 6 7 10 12 14 15 13 11 16 17 Prestige 24 - 32 Solo/ Excellence Unlock Lock

  • GAS CONNECTION Essential recommendations for safety • The gas connection must comply with all applicable local standards and regulations, and the circuit will be equipped with a gas pressure regulator as required. • The gas burners are factory preset for use with natural gas [equivalent to G20]. • The natural gas to propane conversion or the reverse is not authori

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 5 USER’S GUIDE The part number (Code) and serial number (N°) of the appliance are indicated on its rating plate and must be provided to ACV in case of warranty claim. Failure to do so will make the claim void. BOILER MARKING Location: Bottom face Prestige 32 Solo Prestige 24 Solo Prestige 24 Excellence Prestige 32 Excellence

  • ACV Prestige 24 Excellence, 21 1 3 18 2 4 5 6 7 8 9 10 11 12 14 15 13 16 17 19 20 2 1 3 4 5 8 6 7 9 Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D en 16 EN FR NL ES IT DE PL RU APPLIANCE DESCRIPTION 1. Concentric chimney connection 60 /100mm with measuring element 2. Chimney tube 3. DHW tank air vent (manual) 4. Heating supply to DHW tank 5. 12 liter expansion vessel (heating circuit) 6. Internal hot water tank (54 L) 7. Stainless steel heat exchanger 8. High eciency circulator pump 9. Heating return from DHW tank 10. Heating return 11. Control panel with display and pressure gauge 12. Heating supply 13. Exchanger return multifunctional qui- ck-

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D en 2 EN FR NL ES IT DE PL RU TABLE OF CONTENTS GENERAL RECOMMENDATIONS .................................................................................... 3 Safety Instructions........................................................................................................................................................................3 USER’S GUIDE ................................................................................................................... 4 Meaning of Symbo

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 17 TECHNICAL CHARACTERISTICS COMBUSTION CHARACTERISTICS PRESTIGE Solo Excellence 24 32 24 32 G20/G25 G31 G20/G25 G31 G20/G25 G31 G20/G25 G31 Input (PCI) max kW 24 24 32 32 24 24 32 32 min kW 4.0 4.3 4.9 5.0 4.0 4.3 4.9 5.0 Output at 100% (80/60°C) kW 23.3 23.3 31.0 31.0 23.3 23.3 31.0 31.0 (50/30°C) kW 25.5 25.5 33.6 33.6 25.5 25.5 33.6 33.6 Eciency at 100% (80/60°C) % 97. 0 97. 0 97. 0 97. 0 97.0 97. 0 97.0 97.0 (50/30°C) % 106.1 106.1 105.0 105.0 106.1 106.1 105.0 105.0 Eciency at 30%

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 9 USER’S GUIDE Select CH Demand Thermostat & Setpoint Constant & Setpoint 0 - 10 V Modulation Signal CH1 Setpoint 82°C 20°C 87°C CH2 Setpoint 60°C 20°C 87°C EZ Setup Complete Heating EZ setup is complete. Additional changes can be made in the Installer Menu if required. Press OK to return to EZ Setup Menu EZ Setup Select CH Demand Thermostat & Setpoint Constant & Setpoint 0 - 10 V Modulation Signal Select CH Demand Thermostat & Setpoint Constant & Setpoint 0 - 10 V Modulation Signal EZ Setup Complete Heating EZ

  • ACV Prestige 24 Excellence, A D B C 101,6 mm 101,6 mm 48,4 mm 53,2 mm 53,2 mm 48,4 mm 960 mm 406 mm 406 mm 888 mm Prestige 24-32 Solo Prestige 24-32 Excellence Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 19 TECHNICAL CHARACTERISTICS CLEARANCE For boiler mounting on the wall, refer to "Boiler Installation - Wall Mounting" on page 27. Min clearance PRESTIGE 2432 SOLO PRESTIGE 2432 EXCELLENCE A mm 300 300 B mm 25 25 C mm 25 25 D mm 220 110 0 WALL MOUNTING  DIMENSIONS

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS for the Installer and the User 24 - 32 Solo 24 - 32 Excellence Prestige

  • Prestige 24 - 32 Solo Prestige 24 - 32 Excellence CH Target = 85°C Boiler Protection P3 DHW P4 84°C 61°C 1 2 278 mm 440 mm 1014 mm 926 mm 100 mm 60 mm 84 mm 96.5 mm 141 mm 246 mm 352 mm 429 mm 102.5 mm 153,5 mm 280 mm 341 mm 502 mm 141 mm CH Target = 85°C Boiler Protection P3 DHW P4 84°C 61°C 1 2 69.5 mm 104 mm 163 mm 220.

  • ACV Prestige 24 Excellence, 1 5 2 43 Boiler Protection P3 DHW P4 84°C 61°C 1 2 CH Target = 85°C Radiator icon: indicates that a cen- tral heating call has been received. A small number 1 or 2 indicates which CH calls are active Tap icon: indicates that a DHW call has been received. Circulator icons: indicate which circula- tors are currently powered. Status line: displays the current operat- ing state of the boiler. See “Status Mes- sages” on page 7. Basic information. The user can toggle the items using the LEFT and RIGHT keys and view target, Supply, Return, Domestic, Out- door and System temperatures. The boiler type is indicated at the top of the screen. The type an

  • ACV Prestige 24 Excellence, Metallic ring Rubber seals 5 3 4 2 1 6 7 Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 33 INSTALLATION Prestige 24 - 32 Solo / Excellence BALL CONDENSATE TRAP INSTALLATION Fit the condensate trap, making sure to install the items in the correct sequence and connect the hose to the drain using a connection that can be inspected. Fill the trap with clean water. Make sure to prevent any risk of the condensates freezing. Follow-on tasks • Stick the yellow sticker «Propane» (617G0152) on the gas valve. • Reconnect gas pipe connection (3). Torque i.a.w. “Torque Values” on page 40 • Reconnect the grounding cable a

  • ACV Prestige 24 Excellence, DRAINING THE BOILER Essential recommendations for safety • Before draining the DHW tank, drain the heating (primary) circuit or bring its pressure to 0 bar. • Water flowing out of the drain valve may be extremely hot and could cause severe scalding. Keep people away from the hot water discharge. Set-up conditions • Boiler switched o using the ON/OFF master switch • External power supply isolated • Gas supply closed Heating circuit draining procedure 1. Close the isolating valves (1). 2. Connect the drain valve (2) to

  • P/N Designation Qty 507F4301 Pipe external tank conn. P24/32 solo V14 1 507F4132 Angular locking plate hex.36 1 557A0051 Gasket 24x14x2 bres 1 47792006 Screw 4,2x9,5 DIN7981 StZn PH 2 Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 29 INSTALLATION DHW KIT INSTALLATION IN PRESTIGE SOLO BOILERS

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D en 24 EN FR NL ES IT DE PL RU TECHNICAL CHARACTERISTICS G3 REQUIREMENTS AND GUIDANCE  UK ONLY Discharge pipe from safety valves The Building Regulation G3 requires that any discharge from an unvented system is conveyed to where it is visible, but will not cause danger to persons in or about the building. The tundish and discharge pipes should be  tted in accordance with the requirements and guidance notes of Building Regulation G3. The G3 Requirements and Guidance sections 3.50 - 3.63 are detailed below. Fo

  • ACV Prestige 24 Excellence, RECOMMENDATIONS FOR THE PREVENTION OF CORROSION AND SCALING IN HEATING SYSTEMS How oxygen and carbonates can affect the heating system Oxygen and dissolved gasses in the water of the primary circuit contribute to the oxi- dation and the corrosion of the system components that are made of ordinary steel (radiators, ...). The resulting sludge is then deposited in the appliance exchanger. The combination of carbonates and carbon dioxide in the water results in the formation of scale on the hot surfaces of the installation, including those of the appliance exchanger. The

  • ACV Prestige 24 Excellence, 17 18 1 11 15 13 3 14 4 6 5 8 7 9 12 2 16 10 Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 15 APPLIANCE DESCRIPTION MODELS  PRESTIGE 24  32 SOLO / EXCELLENCE The Prestige is a wall-hung condensing boiler meeting the requirements of current “HR-Top” standards in Belgium. The boiler is certied compliant with “EC” standards as a connected appliance: C13(x) - C33(x) - C43(x) - C53(x) - C63(x) - C83(x) - C93(x), but it can also be connected as an open appliance in category B23 or as an appliance of category B23P, which can operate with a positive pre

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D en 10 EN FR NL ES IT DE PL RU USER’S GUIDE Select CH Demand Thermostat & Outd. Curve Constant & Outdoor Curve Constant & Setpoint 0 - 10 V Modulation Signal Select CH Demand Thermostat & Outd. Curve Constant & Outdoor Curve Constant & Setpoint 0 - 10 V Modulation Signal 82°C 27°C 18°C -12°C Current Settings Select CH1 Outd. Curve MAX 60°C 27°C 18°C -12°C Current Settings Select CH2 Outd. Curve Warm Weather Shutdown O O 25°C EZ Setup Complete Heating EZ setup is complete. Addit

  • ACV Prestige 24 Excellence, NOTE This manual contains important information with respect to the installation, the starting up and the maintenance of the appliance. This manual must be provided to the user, who will read it carefully and keep it in a safe place. We accept no liability should any damage result from the failure to comply with theinstructions contained in this technical manual. Essential recommendations for safety • It is prohibited to carry out any modifications to the appliance without the manufacturer’s prior and written agreement. • The product must be installed by a qualified engineer, in accordance with applicable local standards an

  • ACV Prestige 24 Excellence, Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D EN FR NL ES IT DE PL RU en 11 USER’S GUIDE Select CH Demand Thermostat & Outd. Curve Constant & Outdoor Curve Constant & Setpoint 0 - 10 V Modulation Signal CH1 Setpoint 82°C 20°C 87°C CH2 Setpoint 60°C 20°C 87°C EZ Setup Complete Heating EZ setup is complete. Additional changes can be made in the Installer Menu if required. Press OK to return to EZ Setup Menu EZ Setup Complete Heating EZ setup is complete. Additional changes can be made in the Installer Menu if required. Press OK to return to EZ Setup Menu Select CH Demand Thermostat & Outd. Cur

  • 0 0 200 400 600 800 1000 2000 1200 1400 1600 1800 50 100 150 200 250 300 350 400 450 Prestige 24 - 32 Solo/Excellence - Pressure drop vs Water ow rate Pressure drop (mbar) Water ow rate (L/h) Prestige 24-32 Solo/Excellence : A1004335 - 664Y6700 • D en 22 EN FR NL ES IT DE PL RU TECHNICAL CHARACTERISTICS HYDRAULIC CHARACTERISTICS PRESTIGE Solo Excellence Main Characteristics 24 32 2

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony SEL90M28G Operating instructions manual sony/sel90m28g-BI6.pdf 03 Oct 2022 9
2 Pilatus PC - 21 Instruction manual pilatus/pc-21-3K3.pdf 29 Jun 2023 8
3 SpeedLink Sonid Quick install manual speedlink/sonid-33F.pdf 14 Mar 2024 2
4 Nextel iR1200 GPS Installation manual nextel/ir1200-gps-O4Q.pdf 19 Dec 2023 70
5 Gold Note HP-7 Owner's manual gold-note/hp-7-9OW.pdf 27 Jun 2023 12
6 Healthstream HS 1050R Owner's manual healthstream/hs-1050r-BM5.pdf 29 Sep 2022 10

Similar Resources:

  • Immergas

    NIKE MYTHOS 24 2E Series

    (24 pages)
    NIKE MYTHOS24 2 EUA       ...   , 95 42041 ,  …
  • Ferroli

    ATLAS D 30 K 100 UNIT

    (84 pages)
    3541I100cod. 3541I100 — Rev. 00 - 04/2016ATLAS D %#/ K 100 UNIT,7ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE(6INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO(1INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE)5INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D& …
  • Alpha

    Alpha Plus DH Units

    (14 pages)
    Instructions for Installation Alpha Plus DH Units for Domestic Hot Water and Direct Central Heating Alpha Therm Ltd Nepicar House London Rd Wrotham Heath Kent TN15 7RS Leave these instructions with the User …
  • Riello

    Family PRO 42 KIS

    (24 pages)
    cod. 20133095 rev. 104/2018Family PRO 42 KIS-ISUSER’S INFORMATION MANUAL 9WARNING: If the information in this manual is not followed exactly, a re or explosion may result causing property damage, personal injury or loss of life.Do not store or use gasoline or other ammable vapors and liquids or other combustible materials in the vicinity of …
  • Slant/Fin

    VH-120

    (2 pages)
    DESCRIPTIONVH-30 VH-60 VH-90 VH-120 VH-150 VH-1801 Jacket Top Panel 440051 440052 440053 440054 440055 4400562 Jacket Back Panel 412182 412183 412184 412185 412186 4121873 Jacket Left Panel 440067 440067 440067 440067 440067 4400674 Jacket Right Panel 440733 440733 440733 440733 440733 4407335 Jacket Front Upper Panel 440060 440061 440062 440063 440064 44006 …
  • Viessmann

    Vitopend 200-W

    (132 pages)
    VIESMANNInstallation and serviceinstructionsfor contractorsVitopend 200-WType WHKA, 10.5 to 29.3 kWGas fired combi boilerfor balanced flue operationNatural gas and LPG versionFor applicability, see the last pageVITOPEND 200-W5592 817 GB 3/2007 Please keep safe. …

Comments, Questions and Opinions: