Panasonic FPSIGMA Technical Manual
|
Panasonic FPSIGMA, Wiring of the FP-FNS Blocks 43 After wiring, make sure stress is not applied to the wire. In the terminal block socket, make sure to clamp the wire in place by turning the tightening screw clockwise. 4.6.3 FP-FNS Block CANopen Wiring Use a standard CANopen cable and standard 9-pin Sub-D female CANopen connectors. We recommend using a straight (0°) bus interface connector. When a horizontal (90°) bus interface connector is used, the cables will be directed toward the top of the unit, which may cause difficulties when installing other devices in a control cabi
Programming Examples for FPWIN Pro 76 Error code Indication 16#0090 Error in adi mapping AnalogValue 16#0091 Error in adi mapping BinaryValue 16#0092 Error in adi mapping MultistateValue
Panasonic FPSIGMA, Installation and Wiring 32 4.1 Fastening the FP-FNS Block Pins may bend! To ensure that the pins in the FP-FNS do not bend or break, which will ruin the FP-FNS unit, read the following installation instructions carefully and follow them precisely. Make sure you are not electrostatically charged before you touch the FP-FNS block: the discharge of static electricity can damage parts and equipment. 1. CAREFULLY insert the FP-FNS block into the FNS unit's installation port. Do not force the block into the unit! Do not bend the pins! Make sure that the FP-FNS block is properly placed in the installation port of the FNS unit
Panasonic FPSIGMA, FP-FNS Blocks 21 Network Status During start-up, a test sequence is performed on this LED. State Indication Comments Off Offline No power, or no IP address Green Online (RUN) On-line, one or more BACnet messages have arrived Module has active COV subscriptions At least one value object has one or more events enabled Green,flashing Online, waiting Waiting for first BACnet message Red Duplicate IP address FATAL error Red, flashing Connection timeout No BACnet message has been received within the configured 'process active ti
Panasonic FPSIGMA, Outline Dimensions 88 FP-FNS Block DeviceNet, PROFINET IO or BACnet MS/TP For these modules, how far the cable protrudes from the FNS unit face depends on the cable and connector you choose and how you connect it.
Parts and Functions 14 2.3 FPΣ FNS Unit Installation position for FP-FNS block FP expansion connector Used to connect the unit to the control unit or other expansion units. DIN standard rail attachment DIN rail attachment lever Expansion hook Used to secure an expansion unit. The hook is also used for installation on the flat type mounting plate
Panasonic FPSIGMA, Programming Example, FP-FNS Block CANopen 61 FNS_32PDO_INTEGER.EDS, supports the data type integer16 (INT) only FNS_32PDO_64UNSIGNED.EDS, supports the data type unsigned64 only FNSCO4_64IO.EDS, only four RPDOs and four TPDOs are supported If a mixture of data types is used, you can either handle the data in your application program or use the file "FNSCO4_64IO.EDS". This file only supports up to four TPDOs and four RPDOs, but several different data types can be mixed. Please note: only one entry per PDO is allowed, so each PDO can consist of one data type only. Independent of the .eds file used,
Panasonic FPSIGMA, Programming Example, FP-FNS Block DeviceNet 57 Produced data represents data that will be sent to the master. Thus, from the slave's point-of-view, it has to be regarded as output data. Consumed data represents data received from the master. Thus, from the slave's point-of-view, it has to be regarded as input data. Global Variable List To use the DUTs for further programming and to pass on the process data to an application program declare the following global variable with the type of DUT that was created in the previous ste
Panasonic FPSIGMA, Installation and Wiring 42 2. Wrap the end of the cable with 38mm (1.5in.) of shrink wrap, covering part of the exposed conductors and part of the trunk line insulation. 3. Strip 8.1mm (0.32in.) of the insulation from the end of each of the insulated conductors. 4. Insert each conductor into the appropriate clamping cavity of the open style connector or the screw terminal on the device, according to the color of the cable insulation: Wire color Wire identity Usage White CAN_H Signal Blue CAN_L Signal Bare Drain Shield Black V- Power Red V+ Power 5. Tighten the clamping screws to secure each conductor. The male contacts
Panasonic FPSIGMA, Programming Example, FP-FNS Block DeviceNet 59 PLC types: available for FP2/FP2SH and FP. Variables of this function block have to be of one of the following data types: Inputs Input Data Type Function bReset BOOL Reset pin; network block will be reset while bReset is set iSlotNo INT Installation position of the FNS unit iMacID INT DeviceNet address; Values from 0 to 63. pInputs POINTER Pointer to the input's process data table pInConfig POINTER Pointer to the input's configuration data table pOutputs POINTER Pointer to the output's process data table pOu
Panasonic FPSIGMA, Programming Examples for FPWIN Pro 74 5.9.1 FNS_BACnetIP Function Block The FNS_BACnetIP function block configures the FP-FNS block BACnetIP. It has to be supplied with information about the configuration, the input size and network-specific data. If inputs are not used, just leave the corresponding pins unconnected. PLC types: available for FP. Variables of this function block have to be of one of the following data types: Inputs Input Data Type Function iSlotNo INT Installation position of the FNS unit pAnalogValues POINTER Pointer to the Analog Value input process data table pAnalogValuesVarConfig POINTER Pointer to
Panasonic FPSIGMA, Installation and Wiring 38 For the FP2/FP2SH, keep the first 170mm from the PLC front surface clear of objects to allow the connecting of programming tools. For the FP, the distance should be at least 130mm.
Panasonic FPSIGMA, Mounting Methods 39 4.4 Mounting Methods FP-FNS Unit You can attach up to 4 expansion units, including the FP-FNS unit, to the left side of the FP CPU. You can mount all units on a DIN rail. For more information, please refer to the FP User's Manual. FP2-FNS Unit Install the FP2-FNS unit on the FP2 backplane. You can mount the backplane on a DIN rail. For more information, please refer to the FP2 Hardware Manual.
Panasonic FPSIGMA, FP-FNS Blocks 17 Module Status During start-up, an LED test is performed according to the DeviceNet standard. State Indication Off No power or not initialized Green Operating in normal condition Flashing green (1Hz) Missing or incomplete configuration, device needs to be configured Red Unrecoverable fault(s) Flashing red (1Hz) Recoverable fault(s) DeviceNet Connector Pin Signal Description 1 V- Negative bus supply voltage (see note) 2 CAN_L CAN low bus line 3 SHIELD Cable shield 4 CAN_H CAN high bus line 5 V+ Positive bus supply voltage (see note) Mandatory 24V bus power. 2.4.3 FP-FNS Block CAN
Panasonic FPSIGMA, Index 90 FP-FNS Block DeviceNet General Specifications ...................................... 27 FP-FNS Block DeviceNet Wiring ............ 41 FP-FNS Block General Specifications .... 27 FP-FNS Block Profibus Wiring ................................................. 41 FP-FNS Block PROFIBUS DP ................ 15 FP-FNS Block PROFIBUS DP General Specifications ...................................... 27 FP-FNS Block PROFIBUS DP Wiring .... 41 FP-FNS Block PROFINET IO ................. 19 FP
Panasonic FPSIGMA, Index 91 V Vibration resistance ................................ 26 W Weight ..................................................... 26 Wire color ................................................ 41 Wire identity ............................................ 41 Wiring FNS blocks ........................................ 41 Wiring method ......................................... 41 Wiring of the FP-FNS Blocks .................. 41 Wiring of the FPΣ-FNS Unit .................... 45
Panasonic FPSIGMA, Important symbols One or more of the following symbols may be used in this documentation: DANGER! The warning triangle indicates especially important safety instructions. If they are not adhered to, the results could be fatal or critical injury. Indicates that you should proceed with caution. Failure to do so may result in injury or significant damage to instruments or their contents, e.g. data. Contains important additional information. Contains an illustrative example of the previous text section. Indicates that a step-by-step proced
Panasonic FPSIGMA, Programming Examples for FPWIN Pro 68 In the ladder diagram body you can see an instance of the FNS_ProfinetIO function block called Profinet, and how the inputs, outputs and configuration data have to be supplied to the function block. 5.8.1 FNS_ProfinetIO Function Block The FNS_ProfinetIO function block configures the FP-FNS block ProfinetIO. It has to be supplied with information about the configuration, the input and output size and network-specific data. If no inputs or no outputs are used, just leave the corresponding pins unconnected. PLC types: available for FP2/FP2SH and FP. Variables of this function block have to be of one of th
Panasonic FPSIGMA, Parts and Functions 16 PROFIBUS connector, DB9F, 9-pin Sub-D female Pin Signal Description 1 - - 2 - - 3 B Line Positive RxD/TxD, RS485 level 4 RTS Request to send 5 GND Bus ground (isolated) 6 +5V bus output (see note) +5V termination power (isolated) 7 - - 8 A Line Negative RxD/TxD, RS485 level 9 - - Housing Cable shield FP: Internally connected to the function earth connector of the FNS unit. FP2: Internally connected to the earth terminal of the power unit. Any current drawn from pin 6, the +5V bus output pin, will affect the tota
Programming Examples for FPWIN Pro 52 5.5 Programming Example, FP-FNS Block ProfibusDP After you install the FNS Library, you can start programming. 1. Create the Data Unit Types (DUTs) for inputs and outputs. 2. Create input and output variables of the type of DUT generated in the previous step in the global variable list. 3. Generate the configuration data table for inputs
Programming Examples for FPWIN Pro 56 5.6 Programming Example, FP-FNS Block DeviceNet After you install the FNS Library, you can start programming. 1. Create the Data Unit Types (DUTs) for inputs and outputs. 2. Create input and output variables of the type of DUT generated in the previous step in the global variable list. 3. Generate the configuration data table
Panasonic FPSIGMA, 89 Index A Accessory connector .............................. 45 Ambient humidity .................................... 26 Ambient temperature .............................. 26 B Backplane ............................................... 39 Baud rate ................................................ 30 BEFORE BEGINNING .............................. 1 C Cable Selection ....................................... 40 CANopen cable ....................................... 40 CANopen Interface ................................. 17 Conductor ..............................................
Panasonic FPSIGMA, Record of Changes Manual No. Date Description of changes ACGM0160V10END March 2007 First edition ACGM0160V11END May 2007 Product nos. for FNS units and blocks removed (part nos. and product nos. have been harmonized) Addition of CANopen function block for Control FPWIN Pro ACGM0160V20END May 2008 New CANopen block (9-pin Sub-D male interface) Improvements in function blocks for FPWIN Pro for all networks ACGM0160V21EN November 2008 Note added to Profibus programming example that inputs are mapped to the process data before outputs. ACGM0160V30EN M
Panasonic KXF-9R4C Controller Operating instructions manual
KXF-9R4C |
Panasonic FP-M Hardware Controller Manual
FP-M Hardware |
Panasonic FP7 Controller Operation & user’s manual
FP7 |
Panasonic AWRP605P - MULTI FUNCTION CONTROLLER Controller Operating instructions manual
AWRP605P - MULTI FUNCTION CONTROLLER |
Panasonic FP-X0 L14R Controller Operation & user’s manual
FP-X0 L14R |
Panasonic FP7 Controller Operation & user’s manual
FP7 |
Panasonic MINAS S-series Controller Operating manual
MINAS S-series |
Panasonic CY-EM100N Controller Operating instructions
CY-EM100N |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Logik | L5SSTB12 | Instruction manual | logik/l5sstb12-NN6.pdf | 10 Feb 2023 | 48 | |
2 | Samsung | HNR3117 | Owner's manual | samsung/hnr3117-U4P.pdf | 13 Sep 2023 | 75 | 4.67 Mb |
3 | Avital | Phoenix 2 | Installation manual | avital/phoenix-2-1NG.pdf | 29 Aug 2022 | 21 | 0.4 Mb |
4 | Farenheit | TFT7 | Owner's manual | farenheit/tft7-D7G.pdf | 18 Mar 2023 | 10 | 1.78 Mb |
5 | Silent Night | ZEPA-500 | Operation & user’s manual | silent-night/zepa-500-YA9.pdf | 24 Dec 2023 | 12 | |
6 | Panasonic | TH-37PD25U/P | Service manual | panasonic/th-37pd25u-p-EXZ.pdf | 07 Jan 2023 | 255 |
Parker
The Mechanical Subcooler controller was designed as a simple and eco-nomical means of controlling an Electric Expansion Valve on almost any mechanical subcooling system. True pressure and temperature superheat ensures accurate control and safety. All components (valves, controller, sensors) must be supplied by Sporlan to assure compatibility and proper o …
Sporlan SUBCOOL-O-MATIC(4 pages) |
KiWi Lighting
1680 Controller 133 Color Changes 12V For 6803ICDream Color RGB LED Strip LightProduct Model: #BY-CON-DR1680BManufactured by: TopLedLightCategory: LED ControllerRetail price: US$24.99MOQ: 1 PCSNet Weight: 165gShipping: Free Shipping World WidePayment methods: Paypal, Western Union, Wire TransferFor Bulk Orders Discount, please email [email protected] …
TopLedLight BY-CON-DR1680B(3 pages) |
Kirby Morgan
© MMXIX Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 190625006 SF350-1SuperFlow® 350 Regulator SuperFlow® 350 Regulator & Exhaust System Post Dive Cleaning & SanitizingSuperFlow® 350 RegulatorContentsSF350-1 1.1 SuperFlow® 350 Regulator & Exhaust System Post Dive Cleaning & SanitizingSF350-1 1.1.1 Post Dive Disasse …
SuperFlow 350 Regulator(23 pages) |
Emerson
Operating instruction EC3-P33 Superheat Controller and ECD-002 Keypad / Display Unit Installation in non explosive environment Emerson Climate Technologies GmbH www.emersonclimate.eu Am Borsigturm 31 I 13507 Berlin I Germany Date: 04.05.2017 EC3-P33_OI_ML_R01_865919.docx General information: EC3-P33 is the superheat controller for systems with fl …
ECD-002(7 pages) |
Pentair
Raychem-IM-INST196-RAYSTATECO10-ML-1701THERMAL BUILDING SOLUTIONSEnErgy-saving frEEzE protEction controllErEnErgiEsparEndEs stEuErgErät für frostschutzanwEndungEnrégulatEur économiquE pour la misE hors gEl unità di controllo antigElo a risparmio EnErgEticoRAYSTAT-ECO-10
…
RAYCHEM RAYSTAT-ECO-10(46 pages) |
Armstrong
Contents1 Introduction3Copyright, Limitation of Liability and Revision Rights 3Approvals 4Symbols 4Abbreviations 5Definitions 62 How to Programme13Local Control Panel 13How to Operate Graphical LCP (GLCP)How to operate graphical LCP 13Quick Menu Mode 19Function Set-ups 22Main Menu Mode 253 Parameter Description29Parameter Selection 29Main Menu Structure 29Ma …
IVS 102(297 pages) |
Radio Communication Labs Microphone SAFE SPEAK HF3Radio Communication Labs Product Guide: SAFE SPEAK HF3 PDF Operation & user’s manual - 3C8592 SAFE SPEAK HF3, 12 |
Beko Refrigerator GNE 114631 XGNE 114631 X (Refrigerator ePDF User Manual, #16K21V) GNE 114631 X, 170 |
RCS Chiller Cooper Cooler HC01Cooper Cooler HC01 (Chiller ePDF Manual, #5S1653) Cooper Cooler HC01, 44 |
Accu-Chek Blood Glucose Meter AvivaAviva (Blood Glucose Meter ePDF User Manual, #D1QGU1) Aviva, 316 |
Perle Telephone Accessories P2600P2600 (Telephone Accessories ePDF Guide, #T5N322) P2600, 102 |
Gorenje Grill OptiCook 75VGorenje Product User Manual: OptiCook 75V PDF Use and installation - 3J875D OptiCook 75V, 49 |
Stihl Trimmer HLA85Guide: Stihl HLA85 (133Y2Z, Upd.Saturday 25-11-2023) HLA85, 80 |
HP Desktop xw4600HP xw4600 User Guide (Faq), @CL12K7 xw4600, 10 |
DIG Weather Station Leit WWSDIG Leit WWS Weather Station Operating instructions manual Leit WWS, 7 |
Baratza Coffee Grinder Solis MaestroPDF Manual (@N1TS7E), Baratza Solis Maestro Coffee Grinder (18th Oct 2023) Solis Maestro, 4 |
Teknik Indoor Furnishing 5418793Indoor Furnishing Instruction booklet (Teknik 5418793) 5418793, 30 |
Schuchmann Indoor Furnishing MADITA-Fun#MG7AU2: MADITA-Fun Indoor Furnishing User manual manual MADITA-Fun, 24 |