  • Samsung AM160FNBDEH, 47 ENGLISH Connecting temperature sensor of water tank and flow switch f Connect the temperature sensor of water tank to number 7 and 8 of the terminal block located on the bottom side. f Connect 4~20mA temperature sensor for water tank. Temperature sensor must be connected to water tank for hot water operation. V1 V2 L N Flow switch Temperature sensor of water tank (4~20 mA sensor: Temperature range - 0~100 ˚C) 1 2 3 4 5 6 7 8 9 1011121314151617181920 Temperature sensor of water tank (4~20 mA sensor: Temperature range - 0~100 ˚C) 12345678910 <DVM Hydro unit> <DVM Hydro unit HT> k}tGokyvGo{ptXYWZ`]]hTXluU�

  • Samsung AM160FNBDEH, 44 Connecting external contact Wiring 2Way valve f Use a rated wire to connect it as shown in the illustration and fix it with a cable tie. f Initial setting of the valve is 'closed (no flow)'. Normal close type When it is closed When it is opened 2Way valve (N/C type) *N/C (Normal closed) Mixing tank DHW 2Way valve Mixing tank DHW 2Way valve Normal open type When it is closed When it is opened 2Way valve (N/O type) *N/O (Normal open) Mixing tank DHW 2Way valve Mixing tank DHW 2Way valve t Wi

  • Samsung AM160FNBDEH, 20 Water pipe installation 1. You do not need to equip extra expansion tank when there's open type expansion tank on top part of the existing thermal storage tank. However, if you do not have expansion tank, you will need to construct closed type pipe system and equip expansion tank. 2. Water pipe installation system 1) Install the water pipe as shown in the below illustration. All the parts, other than DVM Hydro unit / Hydro unit HT, must follow on site installation specification. <Water pipe connection part> DVM Hydro unit / Hydro unit HT Wa

  • 50 Setting an indoor unit address and installation option f Set the indoor unit address and installation option with remote controller option. Set the each option separately since you cannot set the ADDRESS setting and indoor unit installation setting option at the same time.You need to set twice when setting indoor unit address and installation option. The

  • Samsung AM160FNBDEH, 51 ENGLISH Option setting Status 1. Setting SEG2, SEG3 option Press Low Fan button( ) to enter SEG2 value. Press High Fan button( ) to enter SEG3 value. Each time you press the button, p p … p will be selected in rotation. SEG2 SEG3 2. Setting Cool mode Press Mode button to be changed to Cool mode in the ON status. 3. Setting SEG4, SEG5 option Press Low Fan button( ) to enter SEG4 value. Press High Fan button( ) to enter SEG5 value. Each time you press the button, p p … p will be selected in rotation. SEG4 SEG5 4. Setting Dry mode Press Mode button to be changed to DRY mode in the ON status. 5. Setting SEG6, SEG8 option Press Low Fan button( ) to enter SEG6 va

  • Samsung AM160FNBDEH, 22 Water pipe installation 2) Water pipe socket must be connected with a less tightening torque value stated in the below table. If you apply more torque, it may cause damage to the product. Diameter of water pipe (Outer diameter, mm) 5JHIUFOJOHUPSRVF/tN ø10~20 25 ø21~30 50 ø31~50 100 ø51~80 220 ø81~115 600 ❋ /tNLHGtDN 3) Use certified parts for water pipe system and the water pressure of the water pipe system connected to outdoor unit must remain under 1.

  • Samsung AM160FNBDEH, 57 ENGLISH Changing a particular option You can change each digit of set option. Option SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 Explanation PAGE MODE The option mode you want to change The tens’ digit of an option SEG you will change The unit digit of an option SEG you will change The changed value Remote Controller Display Indication and Details Indication Details Indication Details Indication Details Indication Details Indication Details Indication Details 0D Option mode 0~F Tens’ digit of SEG 0~9 Unit digit of SEG 0~9 The changed value 0~9 t When changing a digit of an indoor unit address setting option, set the SEG3 as ‘A’. t When changin

  • Samsung AM160FNBDEH, 39 ENGLISH Water pump connection f Connect a water pump to B5, B6 of the PBA terminal block. V1 V2 L N Water pump Terminal board B5 Controller Pump Power B6 PCB Relay t Terminal of this product is for water pump and the maximum allowable current is 0.5 A CAUTION Specification table Part Specification Terminal block (Output) B5, B6 Connection type Water pump (No-voltage contact) k}tGokyvGo{ptXYWZ`]]hTXluUGGGZ` YWXZTW_TW]GGG㝘㤸G`a[[aZ\

  • Samsung AM160FNBDEH, ADN✴✴✴BDE✴✴ Series AM✴✴✴FNBD✴✴ Series AM✴✴✴FNBF✴✴ Series DVM Hydro unit / Hydro unit HT installation manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register EN ES EL FR NL IT PL PT HU DE RU ZH DB68-03966A(1) This manual is made with 100% recycled paper. k}tGokyvGo{ptWZ`]]hTXluUGGGZ YWXZTW_TW]GGG㝘㤸G`a\Xa\X

  • Samsung AM160FNBDEH, 11 ENGLISH Dimension of the Hydro unit HT 340 73 330 246 366 466 660 772 333 106 16 365 518 115 27 Communication cable Power cable Gas pipe Liquid pipe Water outlet pipe Water inlet pipe (Unit: mm) Model of the Hydro unit AM✴✴✴FNBF*B Refregerant side Liquid side connection part 3/8” (ø9.52) Gas side connection part 5/8” (ø15.88) Water side connection part PT 1(25A) k}tGokyvGo{ptXYWZ`]]hTXluUGGGXX YWXZTW_TW]GGG㝘㤸G`a[[aY]

  • Samsung AM160FNBDEH, 34 Connecting power and communication cable Connecting the power terminal f Connect the cables to the terminal board using a solderless ring terminal. f Properly connect the cables by using certified and rated cables and make sure to fix them properly so that external force is not applied to the terminal. f Use a driver and wrench that can apply the rated torque when tightening the screws on the terminal board. f Tighten the terminal screws by complying rated torque value. If the terminal is loose, arc heat may occur and cause fire and if the terminal is connected too firmly, terminal may get damaged. Connect one cable per terminal

  • Samsung AM160FNBDEH, 32 Connecting power and communication cable f AM✴✴✴FNBF✴✴ - Single phase - Three phase 1(L) 2(N) N L L F1 F2 V1 V2 F3 F4 N DVM Hydro unit / Hydro unit HT cable tie Communication cable Power cable 1 phase AC 220~240V N L3(T) F1 F2 V1 V2 F3 F4 2(N) 1(L) L2(S) L1(R) R N Communication cable Power cable 1 phase AC 220~240V DVM Hydro unit / Hydro unit HT cable tie k}tGokyvGo{ptXYWZ`]]hTXluUGGGZY YWXZTW_TW]GGG㝘㤸G`a[[aZY

  • Samsung AM160FNBDEH, 64 Appendix Model specification (weight and dimension) Type Model Net weight Net dimension (W x D x H) DVM Hydro unit AM160FNBDEH/EU 29.0 kg 518 x 330 x 627 mm AM320FNBDEH/EU 33.0 kg 518 x 330 x 627 mm AM500FNBDEH/EU 40.0 kg 518 x 330 x 627 mm Hydro unit HT AM160FNBFEB/EU 104 kg 518 x 330 x 1,210 mm AM160FNBFGB/EU 105 kg 518 x 330 x 1,210 mm AM250FNBFEB/EU 104 kg 518 x 330 x 1,210 mm AM250FNBFGB/EU 105 kg 518 x 330 x 1,210 mm Outdoor unit (DVM S HP) AM080FXVAGH 190 kg 880 x 765 x 1,695 AM100FXVAGH 190 kg 880 x 765 x 1,695 AM120FXVAGH 190 kg 880 x 765 x 1,695 AM140FXVAGH 235 kg 1,295 x 765 x 1,695 AM160FXVAGH 278 kg 1,295 x 765 x 1,695 AM180FXVAGH

  • Samsung AM160FNBDEH, 24 Water pipe installation t Circle (O) marks in the chart show the factor relevant to corrosion or water scale. t When the water temperature is over 40˚C, steels without protective coating may corrode when expose to water. Applying corrosion prevention material or degassing can be effective measure to prevent corrosion. t For the cooling water and the make-up water, used under closed circuit water system with closed circuit cooling tower, should satisfy the standard shown in above table. t Supplied water or make-up water should be tap water, industrial water or groundwater. Purified water, neutralized water and softened

  • 28 Connecting power and communication cable Overall system configuration DVM Hydro unit / Hydro unit HT use 220~240 V or three phase, 380~415 V(DVM Hydro unit HT) Distribution board Outdoor unit Indoor unit Earth Earth Communication cable Wired remote controller Wired remote controller Exclusive wired remote controller Wired remote controller ELCB + ELB ELCB or DVM Hydro unit / Hyd

  • Samsung AM160FNBDEH, 48 Connecting external contact Connecting solar pump f Connect the signal wire for solar pump to number 13 and 14 of the terminal block located on the bottom side. V1 V2 L N Controller Power Solar pump 1234567891011121314151617181920 Controller Power Solar pump 12345678910 <DVM Hydro unit> <DVM Hydro unit HT> t Maximum allowable current of each terminal is below 10 mA. t Ports number 13 and 14 is for input port for detection and they do not supply power to a solar pump. CAUTION Specification table Part Specification Terminal block (Input) 13, 14: No-voltage c

  • 30 Connecting power and communication cable Specifications of the cable protection tube Name Material Applicable conditions Flexible PVC conduit PVC When the cable tube is installed indoor and not exposed to outside, because it is embedded in concrete structure Class 1 flexible conduit Galvanized steel sheet When the cable tube is installed indoor but exposed to outside so there are r

  • 58 Product maintenance 1. Water quality management - Plate type heat exchanger is designed in a impossible way to disassemble part for cleaning or replace the parts. To prevent corrosion or water scale on the plate type heat exchanger, you must manage the cooling water quality in compliance with national standards. - If the temperature of water is highe

  • Samsung AM160FNBDEH, 25 ENGLISH Pressure drop graphs f ADN160BDE✴✴ / AM160FNBD✴✴ f ADN320BDE✴✴ / AM320FNBD✴✴ Pressure drop from heat exchanger (kPa)             Water flow rate (ℓ/min) Pressure drop from heat exchanger (kPa)                Water flow rate (ℓ/min)

  • Samsung AM160FNBDEH, 49 ENGLISH Grounding work A ground rod must be installed if the grounding terminal on the power circuit does not exist or meet the standard. Additional accessories required for installation must be purchased separately since they are not supplied with DVM Hydro unit / Hydro unit HT. 1. Prepare a ground rod that matches the one shown in the illustration. Carbon rod or Copper rod Copper wire Green or yellow wire insulated with PVC, 2 mm 2 x 3.5 m Solderless terminal (for M4 screw) 2. Select a appropriate place to install a ground rod. - It is better to select a damp and firm ground than sandy ground or ground with gravels which is high-resisting. - Avoid place with underground struc

  • Samsung AM160FNBDEH, 2 Contents Safety precautions Before installing an DVM Hydro unit / Hydro unit HT please read this manual thoroughly to ensure that you know how to safely and efficiently install a new appliance. Store the Operation and Installation in a safe location and remember to hand it over to the new owner if the Product is sold or transferred. ❋ This product uses R-410A and R-134a(Hydro unit HT) are refrigerant. - When using R-410A and R-134a(Hydro unit HT), moisture or foreign substances may affect the capacity and reliability of the product. Safety precautions must be take

  • Samsung AM160FNBDEH, 29 ENGLISH Power supply and communication cable configuration f Withdraw a main power cable and a grounding cable through the cable outlet on the right side of the DVM Hydro unit / Hydro unit HT. f When connecting external contact signal wire, connect them to the PCB terminal board through the cable outlets in the right side of the outdoor unit. f Wires must be installed after putting them in separate cable protection tubes. f Fix a cable tube at the cable outlet using a CD connector. Wired remote controller wiring Main PCB %7.)ZESPVOJUt0VUEPPSVOJU communication cable Cable protection tube Conduit Power cable terminal board Power cable (Fix

  • Samsung AM160FNBDEH, 16 Refrigerant pipe installation Refrigerant pipe work on DVM Hydro unit Wet cloth Gas pipe Liquid pipe t Caution for welding the pipe to a DVM Hydro unit - When welding the pipe to the product, the unit may get damaged by the heat and flame from welding. Use a flame proofing cloth to protect the unit from a brazing fire or flame. - Wrap the pipe with a wet cloth and weld it as shown in the illustration. Also, water dripping from the wet cloth may interrupt the welding so make sure the water does not drip from the wet cloth. - Make sure that connected pipes of DVM Hydro unit and the outdoor unit does not interrupt each other or

  • Samsung AM160FNBDEH, 43 ENGLISH Connecting 2Way valve f Connect a 2Way valve to B15, B16 and B17 of the PBA terminal block. f 2Way valve is interlocked with 3Way valve 1. V1 V2 L N 2Way valve ❋ Initially, relay is connected between L and B17 of the terminal block. t Terminal of this product is for 2Way valve and the maximum allowable current is 0.5 A CAUTION Specification table Part Specification Terminal block (Output) B15: Output power N B16: Output power L (switch type) B17: Output power L (switch type

  • Samsung AM160FNBDEH, 17 ENGLISH Refrigerant pipe work on DVM Hydro unit HT DVM Hydro unit HT has refrigerant pipes of two different types. f Liquid side pipe f Gas side pipe f Make sure there are no foreign substances and impurities in the pipe. t There is no nitrogen gas inside of connected pipes of Hydro unit HT and the outdoor unit. t DVM Hydro unit HT is using the new refrigerant, R-134a. The connected pipes of Hydro unit HT and the outdoor unit are using R-410A t The product performance or reliability can have grave consequences. t The design pressure is 4.1 MPa, and make sure to consider selecting

  • Samsung AM160FNBDEH, 33 ENGLISH Wiring diagram for connecting 2 wired remote controllers f ADN✴✴✴BDE✴✴ V1 V2 L N Wired remote controller (slave) Wired remote controller (master) f AM✴✴✴FNBD✴✴ / AM✴✴✴FNBD✴✴ V1 V2 L N Wired remote controller (slave) Wired remote controller (master) k}tGokyvGo{ptXYWZ`]]hTXluUGGGZZ YWXZTW_TW]GGG㝘㤸G`a[[aZZ

Related Products and Documents (Heat Pump):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GAMES MICROSOFT XBOX ROGUE TROOPER Manual  games-microsoft-xbox/rogue-trooper-23J.pdf 07 Sep 2022 12 3.35 Mb
2 Home Automation RC-100B Owner's manual home-automation/rc-100b-69B.pdf 23 Mar 2023 20 0.29 Mb
3 Toshiba L675D-S7060 Specifications toshiba/l675d-s7060-48L.pdf 23 Oct 2023 4
4 Masterclock GMR1000 Operation & user’s manual masterclock/gmr1000-2L4.pdf 03 Nov 2022 73
5 Ivation Automatic Pill Dispenser Easy set-up manual ivation/automatic-pill-dispenser-6HV.pdf 29 Jan 2024 2
6 Senco PW-2 Specifications senco/pw-2-16F.pdf 25 Jul 2023 2 0.16 Mb

Similar Resources:

  • Raypak

    5350

    (28 pages)
    INSTALLATION & OPERATINGINSTRUCTIONSCatalog No. RP6000.552E Effective: 06-28-13 Replaces: 11-23-10 P/N 241377 Rev. 7 92-103778-03-07FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors andliquids or other combustible materials in the vicinity of this or any other appliance. Todo so may result in an explosion or fire.Model Se …
  • Bryant

    698B

    (16 pages)
    NOTE: Read the entire instruction manual before starting theinstallation.SAFETY CONSIDERATIONSImproper installation, adjustment, alteration, service, maintenance,or use can cause explosion, fire, electrical shock, or otherconditions which may cause death, personal injury, or propertydamage. Consult a qualified installer, service agency, or yourdistributor or …
  • Payne

    PH13

    (2 pages)
    SAFETY CONSIDERATIONSImproper installation, adjustment, alteration, service,maintenance, or use can cause explosion, fire, electrical shock,or other conditions which may cause death, personal injury, orproperty damage. Consult a qualified installer, service agency,or your distributor or branch for information or assistance. Thequalified installer or agency m …
  • Lochinvar

    Amicus

    (71 pages)
    Amicus Air to Water Heat Pumps Installation, commissioning, user and maintenance instructions Installation manual_LAHP252-5004LT_March 2021 READ AND UNDERSTAND THE INSTRUCTIONS Read and fully understand all instructions before attempting to operate maintain or install the unit. Models: LAHP-252LT to LAHP-5004LT …
  • STIEBEL ELTRON

    WPKI 5

    (6 pages)
    INSTALLATIONINSTALLATIEASENNUSINSTALACEINSTALACJAINŠTALÁCIAWärmepumpen-Kompaktinstallation | Compact heat pump installation | Kit hydraulique pour ballon tampon | Compacte warmtepompinstallatie | lämpöpumppujen asennussarja | Kompaktní instalace tepelného čerpadla | Instalacja kompaktowa dla pomp ciepła | Kompaktná inštalácia tepelného čerpadla …
  • Water Furnace

    500A11 5 Series

    (64 pages)
    IM2500AN 02/13Installation InformationWater Piping ConnectionsHot Water Generator ConnectionsElectricalStartup ProceduresTroubleshootingPreventive Maintenance5 Series 500A11 Installation ManualGeothermal Heat Pump • R-410A Refrigerant • 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6 Ton Single Speed • 2, 3, 4, 5, 6 Ton Dual Capacity500A11ormationonnectionserator …

Comments, Questions and Opinions: