  • Panasonic EW?DE92, © Panasonic Corporation, 2014. Unauthorized copying and distribution is a violation of law. Order Number SD1401Y42CE E6 Sonic Vibration Toothbrush Model No. EW-DE92 North America TABLE OF CONTENTS PAGE PAGE 1 Warning-------------------------------------------------------------- 2 2 Specifications ----------------------------------------------------- 2 3 Troubleshooting Guide ----------------------------------------- 3 4Adjustment--------------------------------------------------------- 6 5 Disassembly and Assembly Instructions ---------------- 8 6 Schematic Diagram ------------

  • Panasonic EW?DE92, 2 1Warning Caution: • Pb free solder has a higher melting point that standard solder; Typically the melting point is 50 - 70°F (30 - 40°C) higher. Please use a soldering iron with temperature control and adjust it to 750 ± 20°F (400 ± 10°C). In case of using high temperature solder- ing iron, please be careful not to heat too long. • Pb free solder will tend to splash when heated too high (about 1100°F / 600°C). 2 Specifications

  • 5 3.2. After reparing 1. Confirm the smooth and normal operation when switching ON. 2. Confirm if the charging status lamp is lit when connecting the main unit with charger. 3. Confirm if the water-proof rubber is assembled without any pinching. 4. Confirm if there is no abnormal sound. NOTE: 1. When the rechargeable battery is replaced, charge the main unit

  • Panasonic EW?DE92, 6 4Adjustment 4.1. Procedure of very weak electric current testing (Main unit) 4.1.1. Measure by the tester available for mA or µA. 1. Set the range at mA or µA. 2. Turn the switch ON without attaching the brush. 3. Touch the (-) terminal of tester with the driving shaft where connecting the brush and the (+) terminal of tester with the ion panel. 4. Measure if the electric current is in between 0.04-0.12mA (40-120µA) with NORMAL mode. And confirm if the ion lamp may glow. It may be the failure if either the current value is out of range or no lit of ion panel. NOTE: • Measure more than three seconds later after switching ON. • Confirm if the mode is selected NORMA

  • Panasonic EW?DE92, 7 4.2. Procedure of very weak electric current testing (Driving block) 4.2.1. Measure by the tester available for mA or µA. 1. Set the range at mA or µA. 2. Turn the switch ON without attaching the brush. 3. Touch the (-) terminal of tester with the driving shaft where connecting the brush and the (+) terminal of tester with the metal terminal A. 4. Measure if the electric current is in between 0.04-0.12mA (40-120µA) with NORMAL mode. And confirm if the ion lamp may glow. It may be the failure if either the current value is out of range or no lit of ion panel. NOTE: • Measure more than three seconds later after switching ON. • Confirm if the mode is s

  • Panasonic EW?DE92, 8 5 Disassembly and Assembly Instructions 5.1. Disassembly Instructions 1. Loosen the screw and remove the battery cover. 2. Putting the driving shaft on the flat space, push down the main body with unfasten two hooks inside of housing by the slotted screwdrivers, and pull out the driving block.

  • Panasonic EW?DE92, 9 3. Put few drops of alcohol onto the shaft of driving block and remove the waterproof rubber. NOTE: Take out the rubber from the center to prevent any damage. 4. Take out the driving block and remove the rechargeable battery.

  • 10 5.2. Assembly Instructions 1. Insert the isolation paper to the cathode side of the rechargeable battery, and set the rechargeable battery so that the battery cushion points upward. 2. Insert the driving block into the housing and apply the grease (Hanarl FL-955) on the water-proof rubber to prevent the pinch- ing. Then, insert the driving block into the housing. NOTE: Make sure not t

  • Panasonic EW?DE92, 14 7.2. Replacement Parts List Safety Ref. No. Part No. Part Name & Description Quantity Remarks 1 WEW0908 IONIC STAIN CARE BRUSH 1 2 WEW0940 POINT BRUSH 1 3 WEW0906 IONIC TWO-WAY SILICONE BRUSH 1 4 WEWDE92S3051 HOUSING 1 5 WEWDE92L4058 DRIVING BLOCK 1 6 WEWDL40L2508 RECHARGEABLE BATTERY 1 LM-ION TYPE 7 WEWDE20K3537 WATERPROOF RUBBER 1 8 WEWDL22L3177 RUBBER HOLDER 1 9 WEWDE42W3547 CONDUCTIVE RUBBER 1 10 WEWDE92W3128 BATTERY COVER 1 11 WEW1023L9007 SCREW 1 K2-8 12 WEWDE92S3032 BODY BLOCK 1 13 WEWDL82W7658 CHARGER 1 A-2 PLUG 14 WEWDL22W3017 MAIN UNIT GUIDE 1

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG GS0713ST Owner's manual lg/gs0713st-685.pdf 06 Jun 2023 25
2 Audiovox SRANT-RMSIR Installation manual audiovox/srant-rmsir-ZA9.pdf 14 Apr 2023 12 0.74 Mb
3 Kramer PT-4 iREX Operation & user’s manual kramer/pt-4-irex-Z62.pdf 06 Feb 2023 11
4 Craftsman 950156 Operators Operator's manual craftsman/950156-operators-52X.pdf 20 Sep 2023 16 2.21 Mb
5 Equipex BAR106 Operation manual equipex/bar106-Y6M.pdf 06 Nov 2023 9 3.02 Mb
6 Konica Minolta bizhub 250 Launch manual konica-minolta/bizhub-250-9J6.pdf 23 Dec 2022 28

Similar Resources:

  • Philips

    Sonicare DiamondClean

    (3 pages)
    How to connect a Sonicare electric toothbrush with a phone. Connecting your Philips Sonicare DiamondClean smart or Flexcare Platinum electric toothbrush to your smart phone is easy. Just follow these simple steps. Connect with your Sonicare app 1. Download the Philips Sonicare app for Android or iOS 2. Open your Sonicare app and press the 'Brush' …
  • Jula

    804-193

    (20 pages)
    Bruksanvisning för eltandborste Bruksanvisning for elektrisk tannbørste Instrukcja obsługi elektrycznej szczoteczki do zębów Operating instructions for electric toothbrush804-193 …
  • Braun

    Oral-B VITALITY

    (9 pages)
    poweredbyVITALITYVITALITYType 3757Oral-B CN GB 0 800 783 7010IE 1 800 509 448 Internet:www.oralb.comwww.braun.comwww.service.braun.comBraun GmbHFrankfurter Straße 14561476 Kronberg/GermanyD12.013D12.013WD12.52399570432/VI-10China/GB99570432_D12_GreaterChina.indd 1199570432_D12_GreaterChina.indd 11 24.06.2010 14:42:49 Uhr24.06.2010 14:42:49 Uhr …
  • Balance

    KH 107

    (16 pages)
    EELLEECCTTRRIICCTTOOOOTTHHBBRRUUSSHHOperating Manual6KOMPERNASS GMBH · BURGSTRASSE 21 · D-44867 BOCHUMwww.kompernass.comID-Nr.: KH107-07/07-V1KH 107CV_KH107_E269_6 27.08.2007 14:45 Uhr Seite 1 …
  • Waterpik Technologies

    WP-450

    (52 pages)
    Waterpik® Water Flosser Model WP-450/462Waterpik® Munddusche Modell WP-450/462Hydropulseur Waterpik® Modèle WP-450/462Idropulsore Waterpik® Modello WP-450/462Waterpik® Water Flosser Model WP-450/462.................www.waterpik.comDO NOT PRINTDATE: 10.17.14CLIENT: WATERPIKFILENAME: 20019158-FAA_WP462E1_IM_rdF2.inddDESCRIPTION: WP 462E1 Instruction Manu …
  • Ningbo

    W1

    (5 pages)
    Oral Irrigator(W1)Instruction ManualThanks for choosing the W1 oral irrigator. Before using the product, please read the manual carefully and keep it for future reference.Tooth washing deviceW1Tooth washing deviceW1Tooth washing deviceW1Oral Irrigator(W1)Instruction ManualThanks for choosing the W1 oral irrigator. Before using the product, please read the ma …

Comments, Questions and Opinions: