  • HP J4367A - UPS R3000 XR, Installation 22 Connecting the ground bonding cable NOTE: UPS appearance might vary depending on the specific unit installed. The ground bonding screw is provided as an attachment point for conductors. Use a ground bonding cable if the rack contains any conductors for the purpose of functional grounding or bonding of ungrounded metal parts. The ground bonding cable is not included. Connecting the UPS to utility power

  • HP J4367A - UPS R3000 XR, Regulatory compliance notices 58 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment f

  • Specifications 46 Specifications UPS physical specifications Parameter Value Height 8.9 cm (3.5 in) Depth 62.2 cm (25 in) Width 44.1 cm (17.5 in) Weight 37 kg (82 lb) ERM physical specifications Parameter Value Height 8.9 cm (3.5 in) Depth 34.3 cm (13.5 in) Width 44.5 cm (17.5 in) Weight 45 kg (100 lb) UPS input specifications NOT

  • HP J4367A - UPS R3000 XR, Component identification 11 UPS R3000 INT rear panel Item Description 1 REPO port 2 ERM connector 3 Serial communications port/options slot 4 Load segment 1 (three IEC-320-C13 receptacles) 5 Load segment 2 (three IEC-320-C13 receptacles) 6 Load segment 3 (three IEC-320-C13 receptacles) 7 Load segment circuit breakers 8 PDU output (IEC-320-C20) receptacle (load segment 1) 9 Cord retention clip attachment locations 10 Input power receptacle (IEC-320-C19) for country-specific plug attachment 11 Ground bonding screw RE

  • HP J4367A - UPS R3000 XR, UPS operations 31 Silencing an audible alarm To silence an alarm, press the Test/Alarm Reset button ("UPS front panel controls" on page 7). IMPORTANT: • Although the audible alarm silences, the condition that caused the alarm to sound may still exist. • If a utility power failure caused the alarm (the Utility LED or the General Alarm LED illuminates red), the alarm silences after power is restored. For information about audible alarm conditions, see "LED and a

  • HP J4367A - UPS R3000 XR, Installation 20 Connecting the REPO port WARNING: The pins on the REPO port are polarity sensitive. Be sure to verify polarity while connecting the REPO port. WARNING: To meet the requirements stated in NEC (NFPA 70) Articles 645-10 and 645-11, a UPS installed in a computer equipment room must be connected to a REPO circuit. IMPORTANT: The remote switch must be in the Off (open) position to enable power to the output receptacles.

  • HP J4367A - UPS R3000 XR, Installation 14 • Hex nuts • Cage nuts • Cage nut-fitting tool Selecting a site WARNING: To prevent fire or electric shock, install the unit in a temperature- and humidity- controlled indoor environment, free of conductive contaminants. When selecting a site, consider the following factors: • Elevated operating ambient temperature—If the equipment is installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment might be greater than room ambient temperature. I

  • HP J4367A - UPS R3000 XR, Maintenance 37 1. (optional) To replace the component with the UPS powered down, refer to "Powering down the UPS (on page 31)." CAUTION: When hot-swapping batteries, the UPS is not protected in the event of a utility power failure, unless at least one ERM is installed. 2. Remove the UPS front bezel ("Removing the UPS front bezel" on page 33). 3. Disconnect the battery leads. 4. Remove the UPS battery bracket. 5. Remove the UPS battery modules. To replace the components, reverse the removal procedure. IMPORTANT: Charge the batter

  • Spares 51 * not shown ERM spare parts list Item Description Spare part number 1 Battery modules (2) 407407-001 2 ERM unit 407398-001 * ERM to UPS cable 407410-001 * UPS/ERM mounting brackets 407408-001 * Mounting rails with screws 419181-001 * not shown Hardware options For information on the supported hardware options, see the

  • HP J4367A - UPS R3000 XR, Specifications 47 1 The output voltage is 204 for this setting. UPS output specifications UPS model Load segment Output receptacles R3000 NA 1 2 x 5-15R 1 x L5-30R 2 2 x 5-15R 3 2 x 5-15R R3000j JPN 1 2 x 5-15R 1 x L5-30R 2 2 x 5-15R 3 2 x 5-15R R3000h NA/JPN 1 3 x IEC-320-C13 1 x L6-20R 2 3 x IEC-320-C13 3 3 x IEC-320-C13 R3000 INTL 1 3 x IEC-320-C13 1 x IEC-320-C20 2 3 x IEC-320-C13 3 3 x IEC-320-C13 Power protection specifications UPS model

  • UPS operations 27 UPS operations Modes of operation The UPS has four modes of operation: • Standby mode (on page 27) • Operate mode (on page 27) • Configure mode (on page 28) • Auto-Bypass mode (on page 28) Standby mode In Standby mode: • No power is available at the UPS output receptacles. • The UPS charges the batteries as necessary. The UPS can be p

  • HP J4367A - UPS R3000 XR, Installation 25 Attaching the ERM front bezel Switching off the ERM circuit breaker WARNING: To prevent personal injury from electric shock or damage to the equipment, verify that the circuit breaker is in the Off position. Connecting the ERM to the UPS NOTE: Before connecting an ERM to a UPS, remove the label from the ERM connector.

  • HP J4367A - UPS R3000 XR, Installation 23 WARNING: To prevent injury from electric shock or damage to the equipment: • Plug the input line cord into a grounded (earthed) electrical outlet that is installed near the equipment and is easily accessible. • Do not disable the grounding plug on the input line cord. The grounding plug is an important safety feature. • Do not use extension cords. Connect the UPS to a grounded utility power outlet. When the UPS is plugged in, it automatically enters Standby mode and begins charging the batteries. Connecting devices to the UPS CAUTION: Do not plug laser printers into the UPS output receptacles. The instantaneous curre

  • HP J4367A - UPS R3000 XR, Spares 50 Spares Ordering spares To order a spare, visit the HP website (http://www.hp.com/buy/parts). To replace parts under warranty, contact an HP authorized service representative. UPS spare parts list Item Description Spare part number 1 UPS unit NA 407390-001 * UPS unit JPN 407392-291 * UPS unit HV NA 407391-001 * UPS unit HV JPN 407393-391 * UPS unit INTL 407395-002 2 X-slot serial card 419180-001 3 Electronics module (low voltage) 407399-001 * Electronics module (high voltage) 407406-001 4 Battery module 407407-001 * Mounting rails with screws 419181-001 * UPS/ERM mounting brackets 407408-001 * Cor

  • HP J4367A - UPS R3000 XR, Regulatory compliance notices 56 to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.

  • HP J4367A - UPS R3000 XR, Installation 15 WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: • The leveling feet are extended to the floor. • The full weight of the rack rests on the leveling feet. • The stabilizing feet are attached to the rack if it is a single-rack installation. • The racks are coupled together in multiple-rack installations. • Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. NOTE: If preparing the rails for integrated shipping, follow the same instructions as in "Installing the UPS (on page 18)."

  • Specifications 48 Configuration setting (VAC) Available nominal output voltage (VAC) 208 208 230 230 240 240 Output tolerance specifications Source of power Regulation Utility power (nominal range) -10% to +6% of nominal output voltage rating (within the guidelines of the Computer Business Equipment Manufacturers Association) Battery power ±5% of nomina

  • HP J4367A - UPS R3000 XR, Index 63 A alarm cannot be silenced 41 alarms, silencing 31 authorized reseller 52 Auto-Bypass mode 28, 42 B backup time, insufficient 45 batteries, care and storage 36 batteries, charging 24, 26 batteries, connecting 19 batteries, obtaining 36 batteries, replacing 35, 36 batteries, runtime 48 batteries, specifications 48 batteries, testing 38 battery bracket 36 battery cables, connecting 19 battery condition 43 Battery Fault LED, location 8 Battery Fault LED, troubleshooting 41 battery replacement notice 59 battery warranty 53 bezel, attac

  • HP J4367A - UPS R3000 XR, Regulatory compliance notices 60 Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal. Power cord statement for Japan

  • HP J4367A - UPS R3000 XR, Regulatory compliance notices 57 Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union regulatory notice This product c

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Hunter 30846 Owner's manual hunter/30846-RCW.pdf 25 Jul 2023 14
2 La Crosse Technology WS-7075U Instruction manual la-crosse-technology/ws-7075u-S12.pdf 18 Dec 2022 23
3 Beyblade Dranzer-F Instructions beyblade/dranzer-f-939.pdf 18 Jun 2023 2 2.29 Mb
4 Toshiba Qosmio X305-Q701 Specifications toshiba/qosmio-x305-q701-EDQ.pdf 30 Dec 2023 4
5 TRENDnet TEW-641PC Datasheet trendnet/tew-641pc-D8Z.pdf 16 Aug 2022 3 0.54 Mb
6 NOAA DSE-120-24 Description, operation, installation and maintenance manual noaa/dse-120-24-G66.pdf 06 Oct 2022 47

Similar Resources:

  • CyberPower

    OM750ATLCD

    (4 pages)
    Aplica para los modelos: OM750ATLCD ó OM900ATLCD ó OM1500ATLCD Manual de Usuario K01-C000102-02 ADVERTENCIAS IMPORTANTES DE SEGURIDAD (GUARDE ESTAS INSTRUCCIONES) Este manual contiene instrucciones importantes de seguridad. Por favor lea y siga todas las instrucciones cuidadosamente durante la instalación y operación de la unidad. Lea este manu …
  • LSI

    MegaRAID iBBU01

    (2 pages)
    38176- 00BThank you for purchasing the LSI MegaRAID LiON (lithium ion) intelligent Battery Backup Unit 01 (LSIiBBU01). The LSIiBBU01 is designed for use on MegaRAID SAS RAID controllers. It protects the integrity of the cached data on a MegaRAID controller for up to 72 hours in the event of a complete AC power failure or a brief power outage.LSI provides a f …
  • Xtreme

    NXRTi 2000VA

    (8 pages)
    S80i Sine Wave Line Interacve UPS2000VA ModelUser & Installaon Manualwww.xpcc.com | © 2015 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 10/08/15) …
  • Riello UPS

    MASTER HP-UL Series

    (83 pages)
    Pag. 1 a 83 0MLMHTK65RUENUB UUNNIINNTTEERRRRUUPPTTIIBBLLEE PPOOWWEERR SSUUPPPPLLYY 65 to 125 kVA Three-Phase Output USER MANUAL MASTER HP-UL …
  • Vertiv

    Liebert ITA2

    (3 pages)
    Vertiv | Liebert® ITA2™ Battery Cabinet Quick-Start Guide | Rev. 0 | 01/18 | 1LIEBERT® ITA2™ BATTERY CABINETQuick-Start GuideThe complete Liebert ITA2 Battery Cabinet user manual is available at Vertiv’s Web site,www.vertivco.com/en-us/products-catalog/critical-power/uninterruptible-power-supplies-ups/ or by using the QR code, below right.Unpack …
  • Mustek

    POWER MUST 424

    (1 pages)
    Features PPRROODDUUCCTT IINNFFOO Product Type Uninterrupted power supply line interactive Input Capacity 400 VA / 240 W z Voltage 220/230/240 VAC z Voltage Range 170 – 285 VAC Output z Voltage Regulation (Battery Mode) ± 10 % z Optional DC Voltage (USB) 5 V z Frequency Range (Battery Mode) 50 Hz ± 1 Hz z Transfer Time Typical 2 – 6 ms …

Comments, Questions and Opinions: