Manualios.com

Toshiba Strata DK Operation & User’s Manual

  • Strata DK Recording Equipment
  • maOHlab8g21MA
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 46

Toshiba Strata DK Manual Online:

4.8, 1560 votes
Toshiba Strata DK User Manual
Toshiba Strata DK User Guide
Toshiba Strata DK Online Manual

Text of Toshiba Strata DK User Guide:

  • Features Simultaneous Voice and Data Calls 14 Strata DK PC/Data Interface 5/00 Simultaneous Voice and Data Calls Voice Call While On Data Call You can make a simultaneous voice and data call between the same or different telephones. While on a data call, a data telephone can originate, answer, and disconnect any type of voice call without interrupting the d

  • Toshiba Strata DK, Mode Definitions Data Communications Mode 34 Strata DK PC/Data Interface 5/00 Note A DIU assumes the V1 default value when power is initially applied to it or when the modular line cord is disconnected and then reconnected. EO Disable character echo in Command Mode E1 Enable character echo in Command Mode H0 Go on-hook (hang up) H1 Go off-hook O Go to Communication Mode Q0 DIU returns Result Codes Q1 DIU does not return Result Codes SR = n Set Register “R” to value “n” (R = 0~12) SR?

  • Toshiba Strata DK, Mode Definitions Data Communications Mode 36 Strata DK PC/Data Interface 5/00 Note A DIU assumes these default values when power is initially applied to it or when the modular line cord is disconnected and then reconnected. Table 8 Default Values Register Value S-Register Control S0 Auto ring enabled S0 = 1 S1 0 rings S1 = 0 S2 ASCII 43 S2 = 43 S3 ASCII 13 S3 = 13 S4 ASCII 10 S4 = 10 S5 ASCII 08 S5 = 8 S7 30 sec. S7 = 30 S9 0.6 sec. S9 = 6 S10 0.7 sec. S10 = 7 S12 1 sec. S12 = 50 Table 9 DIU Dialing Modifier Set Modifier Description 0~9*# Digits/characters for dialing ABCD Digits/characters for dialing P Pulse dial T Tone dial , Delay processing of next character (1 second) ! Hook

  • Toshiba Strata DK, Features Outgoing Data Call 18 Strata DK PC/Data Interface 5/00 ➤ To issue commands to the modem 1. Type ATDT (a system CO line access code, the telephone number of the external modem, or data service) from your PC or terminal keyboard, and then press Enter. Wait 5~30 seconds for the following screen to display on your PC or terminal screen. This display indicates that a connection has been established between the Strata DK system modem and the external modem. XXXX = data transmission speed YYYYYYYYYYYYYY = external telephone number (CO line access code, see Table 4 on Page 28 CO line access codes) The comman

  • Toshiba Strata DK, Features Incoming Data Call (External) 22 Strata DK PC/Data Interface 5/00 ➤ To terminate the call from the external PC or terminal 2. Type ATDD, the [PDN] of the PDIU-DS or data telephone connected to the internal device you wish to connect to, and then press Enter on the external PC or terminal. Wait for the following screen to display on your (external) PC or terminal screen. This display indicates that the external PC or terminal and the internal data device are connected. XXXX = data transmission speed YYY = station number of the DIU If calling a device connected to a PDIU-DS, the CONNECT LED turns ON; if calling a device connected to a dat

  • Toshiba Strata DK, Mode Definitions Data Communications Mode 30 Strata DK PC/Data Interface 5/00 ♦ When in the Data Communications mode, send (ATCØ) to the RPCI to switch it to the TAPI mode. ♦ RPCI mode switching should be performed automatically by the application programs running on the PC connected to the RPCI-DI. Data Communications Command Mode A RPCI or DIU must be told what number to dial, whether to answer, or whether to disconnect. These instructions, when typed from the keyboard of a PC or terminal, are called AT commands. A complete list of RPCI or DIU-supported AT commands is provided in Table 4

  • Features Switch From Outside Voice Call to Data Call Strata DK PC/Data Interface 5/00 23 Switch From Outside Voice Call to Data Call While on a CO line voice call, an internal (Strata DK system) data telephone can switch to a data call on the same line. Before making the call, verify that the communication parameters of your internal PC or terminal match those of th

  • Toshiba Strata DK, The Grand Tour Integrated Data Interface Unit (RPCI-DI) Strata DK PC/Data Interface 5/00 3 RPCI-DI Buttons and LEDs In system programming, the data telephone can be assigned data feature buttons shown below. RPCI-DI Data Connections See the Strata DK I&M Manual for detailed installation instructions. If a data terminal is connected to a data telephone, the terminal must be an ASCII type with a standard keyboard and a display screen or printer display. If a PC is connected to a data telephone, the PC must be running at least one of the following types of programs: word processor, desk organizer dialer, or communications software. Also, the PC must be active (on-line) on its COM por

  • Toshiba Strata DK, Strata DK PC/Data Interface 5/00 37 Index B baud rate, 7 C call data call while on a voice call, 14, 15 data device, 10 from data telephone, 12 from the externa PC or terminal, 21 from your PC or terminal, 11 terminate, 10 voice call while on a data call, 14 CO line, 15, 26 CO line access codes, 28 communication parameters, 6 options, 7 connect LED, 5 D data bits, 7 data call, 3, 10, 12, 14, 24 data communications command mode, 30 mode (on-line state), 32 data communications mode, 29 data release, 3, 10, 12, 13, 15, 19, 27 default values, 36 dial internal modem from your PC or terminal, 17 dialing modifiers, 3

  • Toshiba Strata DK, Strata DK PC/Data Interface 5/00 i Contents Introduction Organization ............................................................................................................... iv Conventions ................................................................................................................. v Mnemonics ................................................................................................................. vi Related Documents and Media ................................................................................... vi Chapter 1 – The Grand Tour Hardware Requirem

  • Toshiba Strata DK, Features Switch From Outside Voice Call to Data Call 24 Strata DK PC/Data Interface 5/00 l 1. Verify communications from your PC or terminal by typing AT and pressing Enter on your PC or terminal. The following screen displays on your PC or terminal screen. This display verifies that communications exist between your PC or terminal and your data telephone. Note AT commands must be typed as capital letters (use caps lock), and they appear on your PC or terminal screen as you type them. 2. Establish an external voice call. The normal method establishes your

  • Toshiba Strata DK, Index S ~ V 38 Strata DK PC/Data Interface 5/00 parameters, 33 S spkr, 15, 27 s-registers, 31 stop bits, 7 switch between data communications and TAPI modes, 29 T terminate a call data connection state, 27 from data telephones, 13, 19 from external PC or terminal, 22 from PC or terminal, 13 voice connection state, 27 voice or data, 15 V verify communications, 11 from your external PC or terminal, 20 from your PC or terminal, 16 DIUC_bok.book Page 38 Wednesday, June 7, 2000 6:15 PM

  • Toshiba Strata DK, Strata DK PC/Data Interface 5/00 29 Mode Definitions 3 This chapter contains advanced information for the sophisticated data communication user. The contents are not required for typical operation. Data Communications Mode When in the Data Communications mode, the RPCI and DIU can operate in either the Command Mode or the Communication Mode. All the dialing, answering, and disconnecting activities related to a data call take place during the command mode using standard Hayes “AT” commands. The actual data operation—file transferring, printing,

  • Toshiba Strata DK, Introduction Organization iv Strata DK PC/Data Interface 5/00 Organization This user guide is divided as follows: ♦ Chapter 1 – The Grand Tour provides an overview of DIU hardware: their function, controls, and applicable indicators. ♦ Chapter 2 – User Instructions provides descriptions and instructions for each type of voice and data transmission made from the DIUs. ♦ Chapter 3 – Mode Definitions contains information on various advanced communication modes. DIUC_bok.book Page iv Wednesday, June 7, 2000 6:15 PM

  • Strata DK PC/Data Interface 5/00 iii Introduction This guide provides instructions for the use of the Strata DK Personal Computer (RCPI-DI) and Data Interface Unit (PDIU-DS) features for the Strata DK systems. These systems include: ♦ DK14 ♦ DK16e and 16 ♦ DK40i and DK40 ♦ DK424i, DK424, DK280 (Release 3.0 or higher) All the features in this guide have practical applications

  • Toshiba Strata DK, Mode Definitions Data Communications Mode Strata DK PC/Data Interface 5/00 35 Table 6 DIU Result Code Set No. Word Description 0 OK Command executed 1 Connect Connection at 0 to 300 bps 2 Ring Ring Signal Detected 3 No Carrier Carrier signal not detected, or lost 4 Error Invalid command, checksum. Error in command line, or command line exceeds 255 characters 5 Connect 1200 Connection at 1200 bps 7 Busy Busy signal detected 10 Connect 2400 Connection at 2400 bps 11 Connect 4800 Connection at 4800 bps 12 Connect 9600 Connection at 9600 bps Table 7 DIU S-Re

  • Toshiba Strata DK, Features Data Call to Another Internal Data Telephone’s PC or Terminal 10 Strata DK PC/Data Interface 5/00 ➤ To call a data device ➤ To terminate the call Data Call to Another Internal Data Telephone’s PC or Terminal PCs involved in this call must be running a communications software program. Before making this call, verify that the communication parameters of your PC or terminal match those of the PC or terminal that you are calling. The following instructions work with typical communications software programs. Higher-level software may integrate these low-level communication

  • Toshiba Strata DK, The Grand Tour Stand-alone Data Interface Unit (PDIU-DS) Connections 4 Strata DK PC/Data Interface 5/00 The data telephone is connected to the PC serial communications port (COMX, where X = 1, 2, 3, or 4) or terminal with an RS-232 cable and connector. It is connected to the Strata DK system like any other digital telephone with a modular cord. Stand-alone Data Interface Unit (PDIU-DS) Connections Data devices, such as printers, modems, mainframe computers, etc., must be connected to a PDIU-DS with an RS-232 cable and connector. An RS-232 conn

  • Toshiba Strata DK, Introduction Mnemonics vi Strata DK PC/Data Interface 5/00 Mnemonics Mnemonics appearing in this user guide are defined below: BPS Bits Per Second DIU Data Interface Unit LCD Liquid Crystal Display LED Light Emitting Diode PC Personal Computer DPIU-DS Stand-alone Data Interface Unit RPCI-DI Personal Computer/Data Interface Unit Related Documents and Media Note Some documents listed here may appear in different versions on the CD-ROM, FYI, or in print. To find the most current version, check the version/date in the Publication Information on the back of the document’s title page. The fol

  • Features Data Call to Another Internal Data Telephone’s PC or Terminal 12 Strata DK PC/Data Interface 5/00 ➤ To call from your data telephone 1. Press 'DWD&DOO. The Data Call, Spkr, and Mic (see note) LEDs turn ON (red); and the [PDN] LED turns ON (green). The data telephone receives an internal dial tone. Note Depending on system programming, the Mic LED may or m

  • Toshiba Strata DK, Features Outgoing Data Call 16 Strata DK PC/Data Interface 5/00 Outgoing Data Call Dialing Through the System Modem Pool A PC involved in this type of call must be running a communications software program. Before making this call, verify that the communication parameters of your PC or terminal match those of the device that your are calling. To place the RPCI-DI into the command mode while keeping the modem in the communications mode, Toshiba recommends that the RPCI-DI escape sequence be changed from +++ to some other sequence before beginning. For example: Using the ATS2 command, send ATS2=

  • Toshiba Strata DK, Features Simultaneous Voice and Data Calls Strata DK PC/Data Interface 5/00 15 Data Call to Data Telephone While on a Voice Call to Another Telephone You can make a simultaneous voice and data transmission to different data telephones. While established on an internal or external voice call, a data telephone can make a data call to another internal or external data telephone or data device. For example, Phone 1 can be on a voice call to Phone 2. At the same time, Phone 1 can also be transmitting data to Phone 3. ➤ To make a data call while on a voice call ➤ To return to the voice call ➤ To terminate voice or dat

  • Toshiba Strata DK, The Grand Tour Stand-alone Data Interface Unit (PDIU-DS) Connections Strata DK PC/Data Interface 5/00 5 PDIU-DS LEDs The PDIU-DS has three green LEDS on its front panel which indicate transmission status (See below). Figure 3 PDIU-DS LEDs Table 2 PDIU-DS LED Status LED Description Power LED When the PDIU-DS is connected to the Strata DK system with a modular cord, the Power LED is ON (lit). Ready LED The Ready LED is ON (lit) when the PDIU-DS is connected to a device that is turned ON and ready to exchange data. Connect LED When a data call is

  • Mode Definitions Data Communications Mode Strata DK PC/Data Interface 5/00 33 RPCI/DIU Data Speed (Baud Rate) DIUs pass data at a baud rate of up to 19,200 bits per second (bps), if the call was established by manually dialing from a data telephone. If the call was established with AT commands from a PC or terminal, the DIU passes data at up to 9600 bps. The baud rate of a DI

  • Toshiba Strata DK, Features Switch From Outside Voice Call to Data Call 26 Strata DK PC/Data Interface 5/00 Switch Back to the Voice Call Using Executive Override If you are on a data call, you can switch back to a voice call from a data call using Privacy or Executive Override, but the data telephone must have Privacy or Executive Override assigned in system programming. 2. Press the busy CO /LQHbutton on the data telephone. The Data and Modem LEDs turn OFF, and the CO line LED changes from red to green. The following screen displays on both PC and/or terminal screens. The system modem is dropped, and the CO line is transferred to the voice path. The external modem goes on-hook, and the voice

  • Toshiba Strata DK, Mode Definitions Data Communications Mode Strata DK PC/Data Interface 5/00 31 Dialing Modifiers can be used for a variety of applications, including tone dialing, dial pulse dialing, and pause and flash inserting. DIUs support the Dialing Modifiers listed in Table 9 on Page 36. S-Registers: RPCIs and DIUs can be configured for specific applications with S- Registers, which can only be changed or checked during the Command Mode. When power is first applied to it and whenever its modular line cord is temporarily disconnected and then reconnected, the RPCI and DIU initializes the S-Register

  • Toshiba Strata DK, Mode Definitions Data Communications Mode 32 Strata DK PC/Data Interface 5/00 ● DIUs can operate at up to 19,200 bps with manual dialing from a data telephone. If keyboard dialing with AT commands, the DIUs can operate at up to 9600 bps. Data Communications Mode (On-line state) A PDIU-DI automatically enters the communication mode when its call to another DIU is answered. At this point, the desired data operation—file transfer, printing, etc., can begin. DIUs remain in the Communications Mode until the data operation is manually terminated or the es

  • Toshiba Strata DK, The Grand Tour Communication Parameters 6 Strata DK PC/Data Interface 5/00 Communication Parameters Before a data connection is established, the communication parameters—data speed (baud rate or bps), parity, data bits, stop bits—of the terminal or PC must be the same as the data device that is calling or being called. The PC communication parameters are set with MS-DOS MODE commands. ➤ To set the PC Communication parameters Communication parameter options are shown in Table 3. ➤ Enter MODE LPTx:=COMx (x = 1, 2, 3, or 4) Use this parameter, if you connect to your printer via an RPCI to DIU-DS

Related Products and Documents (Recording Equipment):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Yamaha PSR-282 Owner's manual yamaha/psr-282-JZ6.pdf 28 Jun 2023 92 8.28 Mb
2 Panasonic SR-TMB10 Operating instructions manual panasonic/sr-tmb10-OY1.pdf 14 Sep 2023 14
3 Avaya IP Office 5410 Operation & user’s manual avaya/ip-office-5410-3N7.pdf 23 Mar 2024 59 1.75 Mb
4 Philips MC146/12 Quick start manual philips/mc146-12-GOU.pdf 18 Nov 2022 4 0.66 Mb
5 Maytag MSF25C2EXW User instructions maytag/msf25c2exw-JDR.pdf 28 Mar 2023 54
6 Canon 3211B001 - PowerShot E1 Digital Camera Software user's manual canon/3211b001-powershot-e1-digital-camera-423.pdf 12 Aug 2023 50 12.1 Mb

Similar Resources:

  • BEIER-Electronic

    SV3-1-8Z

    (17 pages)
    Instruction Manual Controller Type: SV3-1-8Z BEIER-Electronic Winterbacher Str. 52/4, 73614 Schorndorf - Weiler Telefon 07181/46232, Telefax 07181/45732 eMail: [email protected] Internet: www.beier-electronic.de …
  • Eventide

    H9000R

    (3 pages)
    1 Setting up Your H9000R Important Note: The H9000R lacks front panel controls, so all setup and configuration is done remotely using Eventide’s “Emote” software, including the initial network setup. You must use version 1.1 or higher of Emote when working with the H9000R. You may be able to view your H9000R in Emote using 1.0, but connecting to an …
  • BIXOLON

    SRP-350

    (20 pages)
    ◈ Information This installation guide contains only simple information required for the installation of the product. Refer to the User’s Manual in the CD that is shipped with the product for detailed instructions for installation. The contents contained in the CD are as follows. 1. Manual: User’s Manual, Code Table, Control Commands 2. Driver: Wi …
  • Burster

    DIGIFORCE 9311

    (216 pages)
    OPERATION MANUAL DIGIFORCE® Model 9311 Manufacturer: © 2018 burster praezisionsmesstechnik gmbh & co kg burster praezisionsmesstechnik gmbh & co kg All rights reserved Talstr. 1 - 5 P.O. Box 1432 76593 Gernsbach 76587 Gernsbach Germany Germany Valid from: 13.08.2018 Tel.: +49-7224-645-0 Fax: +49-7224-645-88 Email: [email protected]
  • Ferrari electronic

    OfficeMaster CallRecording USB 1xBRI

    (26 pages)
    CALL RECORDINGwww.ferrari-electronic.comFind additional license keys on page 26 (if applicable)Sie finden Ihren Lizenzschlüssel auf der Rückseite dieses Dokumentes(nur für Software)QUICKSTART MANUALQuick Start Manual | Ferrari electronic AGOceMaster CallRecording …
  • OPTO 22

    SNAP PAC S Series

    (70 pages)
    SNAP PAC S-SERIES CONTROLLERUSER’S GUIDESNAP-PAC-S1SNAP-PAC-S2SNAP-PAC-S1-FMSNAP-PAC-S1-WSNAP-PAC-S2-WForm 1592-180803—August 201843044 Business Park Drive • Temecula • CA 92590-3614Phone: 800-321-OPTO (6786) or 951-695-3000Fax: 800-832-OPTO (6786) or 951-695-2712www.opto22.comProduct Support Services800-TEK-OPTO (835-6786) or 951-695-3080Fax: 951-69 …

Comments, Questions and Opinions: