Manualios.com

Toshiba AJ65VBTCU-68ADVN Operation & User’s Manual

  • AJ65VBTCU-68ADVN Control Unit
  • maOHlab8g21MA
  • Operation & User’s Manual
  • PDF / Adobe Acrobat Reader
  • 106

Toshiba AJ65VBTCU-68ADVN Manual Online:

4.1, 2810 votes
Toshiba AJ65VBTCU-68ADVN User Manual
Toshiba AJ65VBTCU-68ADVN User Guide
Toshiba AJ65VBTCU-68ADVN Online Manual

Text of Toshiba AJ65VBTCU-68ADVN User Guide:

  • Toshiba AJ65VBTCU-68ADVN, 5 - 26 5 - 26 MELSEC-A 5 PROGRAMMING (2) Initial setting by remote device station initialization procedure registration function (a) Setting of target station numbers Set the station numbers to which initial setting will be made. Set the target station numbers to "1" and "4". (b) Selection of procedure registration (part 1) Make setting for the AJ65VBTCU-68ADI. Click Procedure registration of target station number "1". (c) Setting of procedure registration (par

  • 6 - 6 6 - 6 MELSEC-A 6 TROUBLESHOOTING Are the station number setting switches properly (not overlapping with other stations)? Set the station number setting switches properly Set the correct transmission speed

  • Toshiba AJ65VBTCU-68ADVN, 3 - 14 3 - 14 MELSEC- A 3 SPECIFICATION Table 3.6 Remote I/O Signal Details (2/2) Device No. Signal Name Description RX(n+1)A Error status flag Turns on at occurrence of an input range setting error, average time/number of times setting error or E 2 PROM write error (RXnC). Does not turn on at occurrence of the watchdog timer error. ("RUN" LED goes off.) RY(n+1)A Error reset request flag RX(n+1)A Error status flag : Performed by sequence ladder : Performed by AJ65VBTCU-68ADVN/ADIN RWrn

  • Toshiba AJ65VBTCU-68ADVN, 4 - 23 4 - 23 MELSEC- A 4 SETUP AND PREPARATION BEFORE OPERATION 4.11 Maintenance and Inspection There are no special inspection items for the AJ65VBTCU-68ADVN/ADIN module, but follow the inspections items describes in the PLC CPU User's Manual so that the system can always be used in the best condition.

  • Toshiba AJ65VBTCU-68ADVN, 5 - 19 5 - 19 MELSEC-A 5 PROGRAMMING (e) Selection of procedure registration (part 2) Make setting for the AJ65VBTCU-68ADVN. Click Procedure registration of target station number "4". (f) Setting of procedure registration (part 2) Set the conditions and execution for the AJ65VBTCU-68ADVN. When the initial data processing request flag (RX18) tur

  • Toshiba AJ65VBTCU-68ADVN, 3 - 8 3 - 8 MELSEC- A 3 SPECIFICATION 3.4 Function List The AJ65VBTCU-68ADVN/ADIN function list is shown in table 3.3. Table 3.3 AJ65VBTCU-68ADVN/ADIN function list Item Description Refer to Sampling processing Perform A/D conversion of an analog input value one by one and store the result into the remote register each time. Section 3.4.1 Section 3.6.4 Average processing Perform A/D conversion by the preset number

  • 3 - 11 3 - 11 MELSEC- A 3 SPECIFICATION (1) Remote I/O signal list for ver. 1 remote device station (ver. 1 compatible slave station) setting Table 3.4 indicates the assignment and names of the remote I/O signals fo

  • Toshiba AJ65VBTCU-68ADVN, A - 1 A - 1 SAFETY PRECAUTIONS (Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. Refer to the user’s manual of

  • Toshiba AJ65VBTCU-68ADVN, 6 - 5 6 - 5 MELSEC-A 6 TROUBLESHOOTING 6.4 Troubleshooting for the Case where the "ERR." LED of the Master Station Flickers The "ERR"LED on the master station is flashing Do the parameter setting and the installed system configuration match properly? Are the master station link special registers SW0080 to SW0083 (other station date link status) turned on? Are the master station link speci

  • Toshiba AJ65VBTCU-68ADVN, 3 - 12 3 - 12 MELSEC- A 3 SPECIFICATION (2) Remote I/O signal list for ver. 2 remote device station (ver. 2 compatible slave station) setting Table 3.5 indicates the assignment and names of the remote I/O signals for ver. 2 remote device station (ver. 2 compatible slave station) setting. Table 3.5 Remote I/O Signal List for Ver. 2 Remote Device Station (Ver.

  • Toshiba AJ65VBTCU-68ADVN, 6 - 3 6 - 3 MELSEC-A 6 TROUBLESHOOTING (3) When the AJ65VBTCU-68ADVN/ADIN "RUN" LED is off Check item Corrective action Is an attempt made to perform operation in the normal mode with the mode select switch set in the test mode? Switch power on again after setting the mode select switch to the normal mode. Has the watchdog timer error occurred? Using the link special registers (SW0084 to SW0087) of the master module, check the watchdog timer error and power on the AJ65VBTCU-68ADVN/ADIN again. If

  • Toshiba AJ65VBTCU-68ADVN, 4 - 10 4 - 10 MELSEC- A 4 SETUP AND PREPARATION BEFORE OPERATION 4.6 Station Number Setting The station number setting of the AJ65VBTCU-68ADVN/ADIN determines the buffer memory addresses of the master module where the remote I/O signals and read/write data are stored. For details, refer to the user's manual of the master module used. 4.7 Facing Direction of the Module Installatio

  • Toshiba AJ65VBTCU-68ADVN, 3 - 10 3 - 10 MELSEC- A 3 SPECIFICATION 3.5 Remote I/O Signals This section describes the assignment and functions of the remote I/O signals. 3.5.1 Remote I/O signal list Remote inputs (RX) mean the input signals from the AJ65VBTCU-68ADVN/ADIN to the master module, and remote outputs (RY) mean the output signals from the master module to the AJ65VBTCU-68ADVN/ADIN. In communications with the master station, the AJ65VBTCU-68ADVN/ADIN uses 32 poi

  • Toshiba AJ65VBTCU-68ADVN, 3 - 4 3 - 4 MELSEC- A 3 SPECIFICATION 3.3.1 Voltage input characteristics of the AJ68VBTCU-68ADVN The voltage input characteristic graph of the AJ65VBTCU-68ADVN is shown below. 3 2 1 4095 4000 2000 -2000 -4000 -4096 0 1 -15 -10 -5 0 5 10 1 5 Analog input voltage (V) Analog input parcitcal value -96 Digital output value Number Analog Input Range Setting Offset Value Gain Value Digital Output Value* Maximum

  • Toshiba AJ65VBTCU-68ADVN, 6 - 1 6 - 1 MELSEC-A 6 TROUBLESHOOTING 6 TROUBLESHOOTING The details of the errors which may occur when using the AJ65VBTCU-68ADVN/ADIN and troubleshooting are described. 6.1 Error Code List If an error occurs (the "RUN" LED of the AJ65VBTCU-68ADVN/ADIN flickers) during write of data from the PLC CPU to the master module, the corresponding error code is stored into the remote register RWrn+8 of the AJ65VBTCU-68ADVN/ADIN. Table 6.1 E

  • Toshiba AJ65VBTCU-68ADVN, A - 3 A - 3 [Starting and Maintenance Precautions] ! CAUTION Do not touch the pin while the power is on. Doing so may cause malfunction. Be sure to shut off all phases of the external power supply used by the system before cleaning. Not doing so can cause the module to fail or malfunction. Never disassemble or modify the module. This may cause breakdo

  • Toshiba AJ65VBTCU-68ADVN, 4 - 20 4 - 20 MELSEC- A 4 SETUP AND PREPARATION BEFORE OPERATION (From the previous page) Latches Pliers 6) Press both ends of the plug cover After pressing the center part of the plug cover, press both ends of the plug cover where latches are located. Verify that the latches engage with the plug body. [Correct example] 0.2mm or less [Wrong example] 7) Check the press-fit condition (viewing from the wiring side). Viewing from the wiring side, check that the

  • Toshiba AJ65VBTCU-68ADVN, A - 5 A - 5 INTRODUCTION Thank you for choosing a Mitsubishi MELSEC-A Series General Purpose Programmable Controller. Before using your new PLC, please read this manual thoroughly to gain an understanding of its functions so you can use it properly. CONTENTS SAFETY PRECAUTIONS..............................................................................................................................A- 1 REVISIONS ...

  • 4 - 2 4 - 2 MELSEC- A 4 SETUP AND PREPARATION BEFORE OPERATION CAUTION Dispose of the product as industrial waste. Use the module in the environment indicated in the general specifications given in this manua

Related Products and Documents (Control Unit):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Ford 07 Sport Trac Quick reference manual ford/07-sport-trac-1U1.pdf 21 Sep 2023 2 1.27 Mb
2 Sonel MPI-520 Operating manual sonel/mpi-520-HN7.pdf 24 Aug 2023 72
3 Sony HDR-PJ200/B Specifications sony/hdr-pj200-b-Y4V.pdf 05 Nov 2022 3
4 Rolls MP26 Manual  rolls/mp26-R26.pdf 24 Feb 2024 1 0.02 Mb
5 Toyota Corolla TNS600 2004 Installation instructions manual toyota/corolla-tns600-2004-QIH.pdf 28 Sep 2023 18
6 Carson SA-450-80 Installation and operating manual carson/sa-450-80-O28.pdf 28 Mar 2023 7 0.1 Mb

Similar Resources:

  • Siemens

    SINUMERIK 840D sl

    (666 pages)
     Milling _______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ …
  • ARI

    Eliptix R-30RM

    (20 pages)
    R-30 RM .IOM.ENG01 R-30 RM 3W Pressure Reducing Control Valve 3 Way The following is a step by step narrated description of the Eliptix R-30RM 3W Pressure Reducing Valve installation, operation and maintenance processes. The A.R.I. R-30 Series is a line of metal, diaphragm-operated, hydraulic control valves. The valves are suitable for in …
  • Rapid Controls

    SAB-Q2

    (5 pages)
    SAB-Q2 Quick Start January 12, 2011SAB-Q2 Quick StartThis document aims to provide a systematic setup procedure to enable you to setup and use your SAB-Q2 as easily as possible. This guide will concentrate on connections and basic setup. More information is available for advanced setup, refer to the SAB-Q2 manual. If you do not have a SAB-Q2 manual, call Rap …
  • AGFEO

    AS 40

    (2 pages)
    TelekommunikationAS 40 - ModulInstallation of the moduleSafty notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢!Before unlocking the cover, remove the 230 V mains plugfrom the telephone system.Opening the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢ …
  • Viking

    G-2000

    (13 pages)
    TECHNICAL DATA2” MODEL G-2000 DRY VALVE RISER ASSEMBLYPage 1 of 13The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: [email protected] the Viking website for the latest edition of this technical data page www.vikinggroupinc.com.Form No. F_0111 …
  • aquabrass

    TURBO Totem T12005

    (11 pages)
    Last revision : 21/08/2019aquabrass.com1TURBO Totem T12005TURBO TOTEM T-12005 1/2” thermostatic valve Valve thermostatique 1/2” T 12005 Guide d’installationInstallation Guide …

Control Unit Instructions:

Comments, Questions and Opinions: