  • Toshiba TOSVERT VF-PS1, E6581539 TOSVERT VF-PS1 series Metasys ® N2 option unit Instruction Manual MTS001Z NOTICE 1. Make sure that this instruction manual is delivered to the end use r of Metasys ® N2 option unit. 2. Read this manual before installing or operating the Metasys ® N2 optio n unit. Keep it in a safe place for reference. 3. All information contained in this manual are subject to change without notice. Please confirm the latest information on our web site “www.inverter.co.jp”.

  • Toshiba TOSVERT VF-PS1, E6581539 - 1 - Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users, damages to assets, and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual to completely understand the safety precautions, the symbols and indications shown below. Please adhere to the contents of these manuals at all times. Explanation of markings Marking Meaning of marking Danger Indicates that errors in operation may lead to death or serious injury. Warning Indicates that errors in operat

  • Toshiba TOSVERT VF-PS1, E6581539 - 2 - Limitation of use Safety precaution Never use this unit with any device other than TOSVERT VF-PS1 series inverters. Doing so may cause an accident. Handling in general Danger Never Disassemble Never disassemble, modify or repair the product. Disassembling the product may cause electric shocks, fire or injuries. For repairs, call your sales/repair agency. Prohibited Do not open the front cover on the inverter while the inverter power is on. It may lead to electric shocks. Do not remove this option from VF-PS1 while the power is on. It may lead to electric shocks. Do not put or insert foreign objects such as waste cable, bars or wires in

  • E6581539 - 3 - Wiring Warning Mandatory Electrical construction work must be done by a qualified expert. Connection of input power by someone who does not have expert knowledge may result in electric shocks or fire. Turn off input power before wiring. Wait at least 15 minutes and make sure that the charge lamp (on the inverter unit) is no longer lit. Oth

  • Toshiba TOSVERT VF-PS1, E6581539 - 4 - Preface Thank you for purchasing the “Metasys ® N2 option (MTS001Z)” for TOSVERT VF-PS1 inverter. By Installing this board into the VF-PS1, data communication can be made with a host computer or other device via Metasys ® N2 network. Before using this unit, carefully read this instruction manual in order to completely and correctly utilize excellent performance of this unit. Besides this instruction manual, the “Metasys ® N2 option Function Manual” which includes the

  • Toshiba TOSVERT VF-PS1, E6581539 - 5 - Table of Contents 1. Overview ···································································································································6 2. Names and functions·················································································································6 2.1. Outline·

  • Toshiba TOSVERT VF-PS1, E6581539 - 6 - 1. Overview The Metasys ® N2 interface (MTS001Z) allows the VF-PS1 inverter to be connected into a Metasys ® N2 network. 2. Names and functions The drawing below shows names and functions of main parts. 2.1. Outline 2.2. Metasys ® N2 Connector Terminal symbol Function Electrical specifications Internal circuits B Communication signal (+) A Communication signal (-) GND Signal common SCR Metasys ® N2 communication signal EIA-485 Shield terminal. B A GND SCR 47k 47k 4.7k 4.7k 120 SW4 T

  • Toshiba TOSVERT VF-PS1, E6581539 - 7 - 2.3. LED indicator The LED shows the present status of the network and error. Layout of LED The option has two LEDs. Those function are below table. State LEDs Comment A COM LED: OFF ERR LED: Flashing 5 times in 1 sec Metasys ® N2 failure. B COM LED: OFF ERR LED: 3 times in 2 sec, Off for 1 sec Communication loss detected. Confirm the network condition and connection of the cable. C COM LED: ON ERR LED: OFF 0.5 sec, ON 0.5

  • Toshiba TOSVERT VF-PS1, E6581539 - 8 - 3. Installing the MTS001Z Install the Metasys ® N2 option to VF-PS1 as follows. Please install this option (MTS001Z) on the top of options when you install two options. Do not install under the another option. (1) Turn off input power of VF-PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-PS1 is no longer lit. (2)Securing the option to the inverter a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front panel, release the panel mounting

  • Toshiba TOSVERT VF-PS1, E6581539 - 9 - 3.1. Network cable connection Connect the Metasys ® N2 network cable to communication option as follows. Title Description Wire type Shielded twisted cable Characteristic impedance Between 100 and 130 ohm Distributed impedance between conductors Less than 100pF per meter Distributed impedance between conductors and shield Less than 200pF per meter Foil or braided shield are acceptable. Length of an MSTP segment 1200 meters with AWG18 (0.8mm 2 ) Cable sheath should be peeled off by about 7mm. For wiring work, use a flat blade screwdriver with a 0.6mm thick and 3.5mm width blade. Tightening

  • Toshiba TOSVERT VF-PS1, E6581539 - 10 - 4. Parameters 4.1. Communication parameters Set up the inverter parameters as follows. To update, reset of inverter. If these parameters are not set to correct value, this unit can not work normally. Title Function Description  Network Time-Out 0: No action Unit: 0.1 sec, Setting range: 1 - 1000 0000 * f851 Operation at communication error by disconnection 0: Inverter stop, communication command, frequency mode open (by cmod, fmod) 1: None (continued operation) 2: Deceleration stop 3: Coast stop 4: Network error ( err8 trip) 5. Preset speed operation command (Op

  • E6581539 - 11 - 4.3. f851: Operation at communication error by disconnection This parameter sets up the VF-PS1 response to a loss of communications with the Metasys ® N2 network. 0: Stop and Communication release The inverter decelerates the motor to a stop and gives an  alarm (the leftmost LED  flashes). Commands entered through the network are canceled, and the

  • Toshiba TOSVERT VF-PS1, E6581539 - 12 - 5. The Metasys ® N2 Local/Remote Operation The example below shows how to configure the VF-PS1 for local/remote operation. F terminal.................Operating command R terminal................The Metasys ® N2 local/remote (Terminal in this example) switching RR/S4 terminal .....Operation frequency command <Wiring> VF-PS1 F R CC PP RR/S4 Variable resistor for adjustmen t 10k ohm Metasys ® N2 / local Switch Operation command SINK SW1 SOURCE CCA <Parameter setting> cmod(Command mode selection) = 0

  • E6581539 - 13 - 6. Specifications < Environmental specification > Item Specification Model number MTS001Z Service environment Indoors, an altitude of 3000m or less, where the product will not be exposed to direct sunlight, corrosive or explosive gasses, vapor, coarse particulate including dust, and where there is no grinding or grinding oil near

Related Products and Documents (DC Drives):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HMS Anybus IP30 Startup manual hms/anybus-ip30-RP9.pdf 09 Mar 2024 12
2 Hiton T-40 Instruction and user's manual hiton/t-40-21C.pdf 25 Jan 2023 14
3 Ace Heating Solutions Packaged Storage Water Heater Steam-to-Water System Operating and maintenance manual ace-heating-solutions/packaged-storage-water-heater-steam-to-water-system-7MQ.pdf 06 Jun 2023 64
4 Atlas AH99-8ST Installation instructions manual atlas/ah99-8st-29Y.pdf 31 Jul 2022 12 0.34 Mb
5 SurgeX SU-2000Li Operation & user’s manual surgex/su-2000li-N48.pdf 05 Feb 2024 24
6 Black & Decker ST4500 Instruction manual black-decker/st4500-38P.pdf 19 Jul 2022 6

Similar Resources:

  • HAUTAU

    SKA 20

    (32 pages)
    © HAUTAU GmbHNachdruck, auch auszugsweise, nur mit schriftlicher Genehmigung des Herausgebers.Im Sinne des Fortschritts behalten wir uns Konstruktionsänderungen und dadurch bedingte Abweichungen von Abbildungen, Abmessungen, Leitungsangaben usw. vor. Die Abbildungen zeigen die Artikel nicht in natürlicher Größe und stehen auch nicht im gleichen Verhält …
  • Danfoss

    VLT 2800

    (6 pages)
    The instructions provide information about installation of themounting adapter for exchanging a VLT® 2800 with a VLT®Midi Drive FC 280.Only Danfoss authorized, qualied personnel is allowed toinstall this equipment. The personnel must be familiar with theinstructions and safety measures described in theVLT® Midi Drive FC 280 Service Guide.Items Supplied …
  • Panasonic

    MINAS A6N Series

    (113 pages)
    Document No. : SX-DSV03089 Revision No. : 8.0 Date of Issue : July 5, 2021 Classification : □ New ■ Change SPECIFICATIONS Product Name: AC servo driver Product Series Name: MINAS A6N Series Product Model Number: Standard type/multi-function type Motion Control Business Unit, Industrial Device Busine …
  • Lenze

    L-force 9400 Series

    (108 pages)
    EDB94Axx6954.AtdÄ.AtdäInbetriebnahme−LeitfadenCommissioning guideGuide de mise en serviceGuía para la puesta en marchaGuida per la messa in servizio9400 1.5 ... 695 AlE94ASHExxxx Single Drive HighLineE94AMHExxxx Multi Drive HighLineAchsmodulAxis moduleModule d’axeMódulo de ejeModulo asseL−force Drives …
  • hager

    x250 HXB04 H Series

    (4 pages)
    x250Echelle 50 %AI1_x250_Cde_motor_T1_01Echelle 40 %AI1_x250_Cde motorisée_T1_02ONTRIPOFF2413ab5Ech. 35%AI1_x250_Cde_motor_T1_03Ech. 50%PUSH TO TRIP15517290 AI1_x250_Cde motorisée_T1_02Ech. 25%(vis + connecteur = 30%étiquette à 40%)x1x1x13 P - 4 P1 indicateur de position de la manette :- rouge = ON- gris = déclenché (Trip)- vert = OFF / Reset2 voyant …
  • Eaton

    Crouse-hinds series

    (12 pages)
    MTL F860 8 segment redundant fieldbus power system for use with Honeywell Experion “Series C” 4-link FIMSeptember 2016INM F860 rev 4Instruction manualMTL fieldbus networks …

Comments, Questions and Opinions: