Manualios.com

Toshiba APG001Z Instruction Manual

Toshiba APG001Z Manual Online:

4.9, 1268 votes
Toshiba APG001Z User Manual
Toshiba APG001Z User Guide
Toshiba APG001Z Online Manual

Text of Toshiba APG001Z User Guide:

  • Toshiba APG001Z, E6581541② TOSVERT VF-PS1 series APOGEE ® FLN option unit Instruction Manual APG001Z NOTICE 1. Make sure that this instruction manual is delivered to the end use r of APOGEE ® FLN option unit. 2. Read this manual before installing or operating the APOGEE ® FLN optio n unit. Keep it in a safe place for reference. 3. All information contained in this manual are subject to change without notice. Please confirm the latest

  • E6581541② - 1 - Safety precautions On the inverter and in its instruction manual, important information is contained for preventing injuries to users, damages to assets, and for proper use of the device. Read the instruction manual attached to the inverter along with this instruction manual to completely understand the safety precautions, the symbols and indications sho

  • E6581541② - 2 - Limitation of use Safety precaution Never use this unit with any device other than TOSVERT VF-PS1 series inverters. Doing so may cause an accident. Handling in general Warning Never Disassemble Never disassemble, modify or repair the product. Disassembling the product may cause electric shocks, fire or injuries. For repairs, cal

  • Toshiba APG001Z, E6581541② - 3 - Wiring Caution Mandatory Electrical construction work must be done by a qualified expert. Connection of input power by someone who does not have expert knowledge may result in electric shocks or fire. Turn off input power before wiring. Wait at least 15 minutes and make sure that the charge lamp (on the inverter unit) is no longer lit. Otherwise, it may lead to electric shocks. Tighten the screws on the terminal blocks to the specified torque when connecting cables to terminal b

  • Toshiba APG001Z, E6581541② - 4 - Preface Thank you for purchasing the “APOGEE ® FLN option (APG001Z)” for TOSVERT VF-PS1 inverter. By Installing this board into the VF-PS1, data communication can be made with a host computer or other device via APOGEE ® FLN network. Before using this unit, carefully read this instruction manual in order to completely and correctly utilize excellent performance of this unit. Besides this instruction manual, the “APOGEE ® FLN option Function Manual” which includes the contents to install into APOGEE ® FLN network is prepared. If it is required, please contact with our branch offi

  • Toshiba APG001Z, E6581541② - 5 - Table of Contents 1. Overview ···································································································································6 2. Names and functions······················································································

  • Toshiba APG001Z, E6581541② - 6 - 1. Overview The APOGEE ® FLN interface (APG001Z) allows the VF-PS1 inverter to be connected into a APOGEE ® FLN network. APG001Z is applicable for VF-PS1 software version V620 or later. 2. Names and functions The drawing below shows names and functions of main parts. 2.1. Outline 2.2. APOGEE ® FLN Connector Terminal symbol Function Electrical specifications Internal circuits B Communication signal (+) A Communication signal (-) GND Signal

  • Toshiba APG001Z, E6581541② - 7 - 2.3. LED indicator The LED shows the present status of the network and error. ■Layout of LED The option has two LEDs. Those function are below table. State LEDs Comment A COM LED: OFF ERR LED: Flashing 5 times in 1 second APG001Z failure. B COM LED: OFF ERR LED: 3 times in 2 seconds, OFF for 1 second Communication loss was detected. Confirm the network condition and connection of the cable. C COM LED: ON ERR LED: OFF 0.5s, ON 0.5s Invalid configuration was detected. (Note)When inverter occurred in e-23 or e-24, the LED becomes this state. D COM L

  • Toshiba APG001Z, E6581541② - 8 - 3. Installing the APG001Z Install the APOGEE ® FLN option to VF-PS1 as follows. Mandatory Turn off the input power of VF-PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-PS1 is no longer lit. (1) Turn off input power of VF-PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-PS1 is no longer lit. (2) Securing the option to the inverter a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front panel, release the panel mounting tab by pushing the screwdriver down and remove the front

  • Toshiba APG001Z, E6581541② - 9 - 3.1. Case of installing two options Please install this option (APG001Z) on the top of options when you install two options. Do not install under the another option. 3.2. Network cable connection Connect the APOGEE ® FLN network cable to communication option as follows. Title Description Wire type Shielded twisted cable Characteristic impedance Between 100 and 130 ohm Distributed impedance between conductors Less than 100pF per meter Distributed impedance between conductors and shield Less than 200pF per meter

  • Toshiba APG001Z, E6581541② - 10 - 3.3. Network configuration Make up the network as follows. - Transmission/reception signals (A, B) Make up the communication path by connecting all transmission/reception data cables. - Signal common (GND) GND is the signal common. - Grounding the shield of cable (SCR) Connect the all shield lines of network cable. The shield shall be grounded at one end only prevent currents from being created. - Termination resistor A termination resistance of 120 ohms plus or minus 5% shall be connected at each of the two ends of the segment medium. This option has a termination resistor, so if use, set up the termination resistor SW. (Refer to 2.1 Outline) *

  • Toshiba APG001Z, E6581541② - 11 - 4. Parameters 4.1. Communication parameters Set up the inverter parameters as follows. To update, reset of inverter. If these parameters are not set to correct value, this unit can not work normally. Title Commu nication No. Function Description Factory setting f831 0831 Network Baudrate (*1) 0: 9600bps,1: 4800bps,2: 9600bps 3: 19200bps,4: 38400bps, 5: 57600bps,6: 76800bps Over 7 is 9600bps. 0000 f832 0832 Network Time-Out (*1) 0: No action Unit 0.1 sec, Setting range: 1 – 1000 Over 1000 is 100.0s. 0000 f833 0833 Factory setting (*1) Except ACh:Reset to factory setting ACh:Finished with reset to factory set

  • E6581541② - 12 - 5. Command & Setpoint selection (Local/Remote) Indication to display Local/Remote mode is on the inverter unit (Refer to the inverter instruction manual for details). APOGEE ® FLN option command and setpoint are activated on Remote mode. Inverters have some switches to select the command and setpoint location. Following figure show

  • Toshiba APG001Z, E6581541② - 13 - <Example> The example below shows how to configure the VF-PS1 for local/remote operation. F terminal..................... Operating command R terminal .................... The APOGEE ® FLN local/remote (Terminal in this example) switching RR/S4 terminal.......... Operation frequency command <Wiring> VF-PS1 F R CC PP RR/S4 Variable resistor for adjustmen t 10k ohm The APOGEE ® FLN /local Switch Operation command SINK SW1 SOURCE CCA <Parameter setting> cmod (Command mode selection) = 0 (Terminal b

  • Toshiba APG001Z, E6581541② - 14E - 6. Specifications < Environmental specification > Item Specification Model number APG001Z Service environment Conforms to VF-PS1 Ambient temperature Conforms to VF-PS1 Storage temperature Conforms to VF-PS1 Relative humidity Conforms to VF-PS1 Vibration Conforms to VF-PS1 Power supply 24VDC supplied from the inverter <APG001Z network specification > Item Specification Station type Remote device station Number of occupied stations 1 station occupied by 1 unit Maximum FLN device 32 FLN devices to each FLN port of the Field Cabinet. Communication baud rate

Related Products and Documents (DC Drives):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Draytek Vigor 2820Vn Declaration of conformity draytek/vigor-2820vn-431.pdf 16 Nov 2023 1 0.04 Mb
2 ArmorAll AA255 Operator's manual armorall/aa255-8JD.pdf 30 Jan 2023 34
3 Victorinox ST-5000 DIGITAL COMPASS Using victorinox/st-5000-digital-compass-55H.pdf 20 Nov 2022 1 3.68 Mb
4 Bosch NEM73 Installation instructions manual bosch/nem73-FLV.pdf 25 Oct 2022 8 0.3 Mb
5 AMX NI-2100 Hardware reference manual amx/ni-2100-H48.pdf 18 Feb 2023 36 1.18 Mb
6 Siemens SSA955 Manual  siemens/ssa955-E25.pdf 19 Dec 2023 10

Similar Resources:

  • Rexnord

    Falk Quadrive A Series

    (53 pages)
    Rexnord 378-2063001 W. Canal St., Milwaukee, WI 53208-4200 USA January 2019Telephone: 414-342-3131 Fax: 414-937-4359 www.rexnord.com Supersedes 07-15(PN-212395)Falk® Quadrive® Shaft-Mounted Drives Model A • Owners ManualSizes 5407-5608 (Page 1 of 53)TABLE OF CONTENTSIntroduction ....................................2Drive Identification ............ …
  • TECHTOP

    Topdrive350 Series

    (2 pages)
    Place the drip-cover behind the drive and align the mounting holes of the drip-cover with the top mounting holes of the drive. Use the screws for mounting the drive to secure the drive and the drip cover to the mounting surface.Screw quantity: 4Screw specifications: Same as mounting screwsSTEP 1TECHTOP GENERAL PURPOSE VECTOR DRIVES, TD350 NEMA 1 KIT INSTALL …
  • Festo

    DFPI Series

    (5 pages)
    Translation of the original instructions© 2020 all rights reserved to Festo SE & Co. KG1 Safety1.1 General Safety Instructions– Only use the product in original status without unauthorised modifications.– Only use the product if it is in perfect technical condition.– Use only proximity sensors approved for the product.– Take into consideration t …
  • Danfoss

    VLT 8000 AQUA

    (206 pages)
    VLT®8000 AQUA■ ContentsIntroduction......................................................................................................... 4Software version ....................................................................................................... 4Definitions ................................................................................. …
  • Delta

    VFD-B Series

    (250 pages)
    Preface Thank you for choosing DELTA’s high-performance VFD-B Series. The VFD-B Series is manufactured with high-quality components and materials and incorporate the latest microprocessor technology available. This manual is to be used for the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drive. To guarantee saf …
  • Danfoss

    PTU 025

    (10 pages)
    Items SuppliedSee Illustration 1.1 for the list of supplied items.1 M25 nut 5 Pressure Transmitter Unit PTU 0252 M25 ground washer connection 6 Tube relief plate3 M25 star washer 7 Interface cable for the C-option port4 M25 gasket 8 Cable bindersTable 1.1Illustration 1.1 Pressure Transmitter Unit PTU 025 and Items SuppliedInstallation InstructionsPressure T …

Comments, Questions and Opinions: