  • Phoenix Contact QUINT-DC-UPS/24DC/40, 1. Short Description Uninterruptib le Power Supply Units for Buffering Long-Term Power Interruptions • Saves space thanks to the compact, uniform design • Integrated diode saves money through isolation of loads • Maximum system availability through optimum battery management and reliable signaling • Minimum installation time due to ready-to-use plug-in bridges and integrated timeout QUINT-DC-UPS uninterruptible power supply units with long-life lead-acid batteries provide long buffer times at high currents. Even in the event of a longer supply voltage failure, the units ensure that all connected devices continu

  • Phoenix Contact QUINT-DC-UPS/24DC/40, PHOENIX CONT A CT page 2 of 9 Solid Str anded T orque [mm 2 ] A WG [Nm] [ lb in] Input 0.5 - 16 0.5 - 10 20 - 6 1.2 - 1.5 10.6 - 13.3 Output 0.5 - 16 0.5 - 10 20 - 6 1.2 - 1.5 10.6 - 13.3 Signal 0.2 - 2.5 0.2 - 2.5 25 - 14 0.5 - 0.6 4.5 - 5.3 Descr iption Uninterr uptib le po wer suppl y unit 3.4 Ah batter y module 7.2 Ah batter y module 12 Ah batter y module T ec hnical Data Input Data Nominal input v oltage Input v oltage r ange Current consumption (No load/charging/maxim um) Switching thre

  • Phoenix Contact QUINT-DC-UPS/24DC/40, PHOENIX CONT A CT page 3 of 9 Uninterruptib le Power Supply Unit for Universal Use – QUINT-DC-UPS/24DC/40 Green LED Red LED , fl oating PDT , 30 V A C/DC , maxim um; 1 A, maximum Yellow LED, floating PDT, 30 V AC/DC, maximum; 1 A, maximum Yellow LED, flashing, floating PDT, 30 V AC/DC, maximum; 1 A, maximum EN 60 204 (Surge Voltage Category III) EN 60950/VDE 0805, UL/C-UL Recognized UL 60 950 UL/C-UL Listed UL 508 Germanischer Lloyd EN 50 178/VDE 0160 1 kV AC type test 1 kV AC routine test On a horizontal 35 mm (1.378 in.) DIN rail EN 60 7

  • PHOENIX CONTACT page 4 of 9 11 11 DC input, unbuffered 24 V DC input voltage (0.5 mm 2 to 16 mm 2 solid) (0.5 mm 2 to 10 mm 2 stranded) (20 - 6 AWG) Internal fuse 50 AT 22 22 DC output, buffered 24 V DC output voltage (0.5 mm 2 to 16 mm 2 solid) (0.5 mm 2 to 10 mm 2 stranded) (20 - 6 AWG) The device is idling-proof and short-circuit-proof.

  • Phoenix Contact QUINT-DC-UPS/24DC/40, PHOENIX CONTACT page 5 of 9 Uninterruptible Power Supply Unit for Universal Use – QUINT-DC-UPS/24DC/40 5. Installation 5.1. Mounting The uninterruptible power supply unit together with the battery module can be snapped onto all DIN rails according to EN 60715 and should be mounted horizontally (input terminal blocks facing downwards). Installation Dimensions No minimum spacing to other modules is required for proper operation of the device. 5.2. Narrow Mounting Position The device is supplied ex works for a narrow mounting position. Mounting: Place the module with the DIN r

  • PHOENIX CONTACT page 6 of 9 Uninterruptible Power Supply Unit for Universal Use – QUINT-DC-UPS/24DC/40 QUINT-DC-UPS Power Supply + – AC DC Unbuffered Load + – DC Buffered Load Input Output Battery + – + – + – + – QUINT-BAT/24DC + – + – D C 24 V 40 A Inp ut O utpu t 3 14 DC OK + + 13 14 DC OK + + 13 14 DC OK + + + – +2

  • Phoenix Contact QUINT-DC-UPS/24DC/40, PHOENIX CONTACT page 7 of 9 5.6. Output All devices that must be supplied without interruption in the event of a supply voltage failure ("Buffered Load"), are connected to the "Output +" and "Output -" terminal blocks of the DC output (Fig. 08). It is recommended that all other loads, which do not require buffering ("Unbuffered Load"), are connected to the 24 V DC output of the power supply. This increases the buffer time, as this time depends on the output current (see Fig. 10). The internal diode ensures that the buffere

  • Phoenix Contact QUINT-DC-UPS/24DC/40, PHOENIX CONTACT page 8 of 9 Uninterruptible Power Supply Unit for Universal Use – QUINT-DC-UPS/24DC/40 5.9. Remote Shutdown ("Remote", Fig. 12) The device has a UPS remote shutdown function for specific shutdown. Remote shutdown must be deactivated for the device to switch to buffer mode in the event of a supply voltage failure. Remote Shutdown Off • The "Remote shutdown R1" and "Remote shutdown R2" terminal points are short circuited (e.g., with a plug-in bridge) OR The "Remote shutdown R2" terminal point is supplied with a 24 V DC voltage • The QUINT-DC-UPS switches to buffer mode in

  • Phoenix Contact QUINT-DC-UPS/24DC/40, PHOENIX CONTACT page 9 of 9 7. Method of Operation In the event of a power failure at the output, the QUINT-DC-UPS supplies all connected devices with a 24 V DC voltage without interruption at a load current up to 40 A. When the 24 V supply voltage is applied, the connected battery module is charged. In the event of a supply voltage failure, the battery module is connected to the output, and the stored power ensures that all connected devices continue to operate without interruption. The professional signaling via function LEDs and floating PDT contacts enables reliable evaluation of a

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Honeywell MC ToolKit Operation & user’s manual honeywell/mc-toolkit-Z3R.pdf 02 Dec 2023 103 3.37 Mb
2 Cateye CC-MT400 Owner's manual cateye/cc-mt400-U8C.pdf 31 Aug 2022 2 0.29 Mb
3 Everpure Helia CGHC-1 Instant Specification sheet everpure/helia-cghc-1-instant-E5S.pdf 23 Oct 2022 2 1.65 Mb
4 Boss Audio Systems BV10.4IRF Operation & user’s manual boss-audio-systems/bv10-4irf-3D3.pdf 13 Oct 2022 14 0.6 Mb
5 Tripp Lite USA-49WG Owner's manual tripp-lite/usa-49wg-CLA.pdf 20 Apr 2023 23 1.31 Mb
6 Lasko 2534 Operating manual lasko/2534-ZJP.pdf 05 Aug 2023 6

Similar Resources:

  • Middle Atlantic Products

    UPS-2200R-HH

    (27 pages)
    082410-01I-00462 Rev DUPS-2200R-HH/UPS-2200R-HHIP RACKMOUNT UNINTERRUPTIBLE POWER SUPPLYUSER MANUALTHANK YOUThank you for purchasing the UPS-2200R-HH/UPS-2200R-HHIP Rackmount UPS. The UPS provides battery backup during power outages, automatic voltage regulation during periods of inconsistent utility power and surge protection. Please read this ma …
  • Emerson

    Liebert PSA

    (2 pages)
    Liebert® PSA™Quick-Start Guide - 500VA/650VA, 230VIMPORTANT SAFETY INSTRUCTIONS• Do not connect equipment that may overload the UPS or demand half-wave rectification, such as a laser printer.• Connect the UPS only to an earthed / grounded socket that meets electrical safety guidelines.• Locate the UPS near a wall socket. Do not use an extension cord …
  • DKC

    INFO400

    (52 pages)
    Руководство пользователя Manuale d’ uso User’s Manual Источник Бесперебойного Питания Info / Info LCD 400-2000 ВА Uninterruptible Power Supply Info / Info LCD 400-2000 VA …
  • Energizer

    ER-OF800

    (2 pages)
    ER-OF800Congratulations on your new Energizer® ER-OF800 UPS Power Protection system. This product is specifically designed for home office and workstation. With the newest technology, this series can operate under a wide range of input utility power while maintaining steady output voltage. Why is this important? Some equipment requires consistent backup …
  • Riello

    100 kVA

    (45 pages)
    100 & 120kVA UNINTERRUPTIBLE POWER SUPPLY SYSTEM Riello Multi Plus UPS available from EcoPowerSuppliesFor more information visit: www.ecopowersupplies.com/riello-ups …
  • Power-all

    Uninterruptible Power System

    (4 pages)
    UUSSEERR''SS MMAANNUUAALL Uninterruptible Power System IP-Invisimo-06 …

Comments, Questions and Opinions: