  • Siemens SCALANCE W774-1, Connection 5.2 Power supply SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 39 5.2 Power supply Note Galvanic isolation of the power supply unit To ensure dielectric strength according to IEEE 802.3, the supplying 24 V power supply unit must be galvanically isolated with a dielectric strength of 1500 VAC. The galvanic isolation must also not be bridged by other devices connected to the same power supply unit. SCALANCE W774/W734 RJ-45 For the power supply, there are two options with the S

  • Siemens SCALANCE W774-1, Connection 5.2 Power supply SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 41 Power over Ethernet The two following variants are available for power supply via an Ethernet cable: ● IEEE 802.3at type 1 (IEEE 802.3af) On an 8-wire Fast Ethernet cable, the power is supplied via the free data wires 4, 5, 7 and 8. This corresponds to alternative B according to IEEE 802.3af. ● IEEE 802.3 at type 2 The power supply is known as phantom power via the wire pairs carrying signals (1/2 and 3/6). The SCALANCE W774/W734 RJ-45 devices support the standards IEEE 802.3at type 1 (IEEE 802.3af ) and IEEE 802.3.at type 2. Note D

  • Technical data 7.2 Technical specifications W774 M12 SCALANCE W774-1 /W734-1 56 Operating Instructions, 01/2017, C79000-G8976-C325-08 7.2 Technical specifications W774 M12 The following technical specifications apply to the following devices: ● SCALANCE W774-1 M12 EEC Note You will find detailed information on the transmit power and receiver s

  • Siemens AG Division Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY C79000-G8976-C325-06 Ⓟ 01/2017 Subject to change Copyright © Siemens AG 2013 - 2017. All rights reserved Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal saf

  • Siemens SCALANCE W774-1, Connection 5.4 Antenna connectors SCALANCE W774-1 /W734-1 44 Operating Instructions, 01/2017, C79000-G8976-C325-08 5.4 Antenna connectors The SCALANCE W774/W734 has two antenna connectors of the type R-SMA located on the top of the device. ① Antenna connector R1 A1 ② Antenna connector R1 A2 Procedure Follow the steps below to connect a cable for an external antenna to a SCALANCE W774/734: 1. Insert the connector on the antenna cable into the R-SMA socket and tighten the sleeve nut of the plug on the socket (key size SW8, tightening torque 1 Nm). If you only use one antenna, you need to connect this to the device via antenna connector

  • Siemens SCALANCE W774-1, Description of the device 3.4 Accessories SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 15 3.4 Accessories Technical data subject to change. You will find further information on the accessories program in the Industry Mall. (https://mall.industry.siemens.com) PLUG Component Description Article number C-PLUG Configuration PLUG, Exchangeable storage medium (32 MB) for the configuration data 6GK1 900-0AB00 KEY-PLUG features Enabling of iFeatures and ex

  • Siemens SCALANCE W774-1, SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 5 Introduction 1 1.1 Information on the Operating Instructions Validity of the Operating Instructions These operating instructions cover the following products: Article no. of the RoW version Article no. of the US version Article number of the Israel version Access points SCALANCE W774-1 RJ-45 6GK5774-1FX00-0AA0 6GK5774-1FX00-0AB0 6GK5774-1FX00-0AC0 SCALANCE W774-1 M12 EEC 6GK5774-1FY00-0TA0 6GK5774-1FY00-0TB0 - Ethernet client module SCALANCE W734-1 RJ-45 6GK5734-1FX00-0A

  • Siemens SCALANCE W774-1, Security recommendations SCALANCE W774-1 /W734-1 10 Operating Instructions, 01/2017, C79000-G8976-C325-08 Available protocols per port The following list provides you with an overview of the open ports on this device. The table includes the following columns: ● Protocol All protocols that the device supports ● Port number Port number assigned to the protocol ● Port status – Open The port is always open and cannot be closed. – Open (when configured) The port is open if it has been configured. ● Factory setting – Open The fac

  • Siemens SCALANCE W774-1, Connection 5.1 Lightning protection, power supply and grounding SCALANCE W774-1 /W734-1 38 Operating Instructions, 01/2017, C79000-G8976-C325-08 General notes on use according to ATEX and IECEx WARNING EXPLOSION HAZARD DO NOT CONNECT OR DISCONNECT EQUIPMENT WHEN A FLAMMABLE OR COMBUSTIBLE ATMOSPHERE IS PRESENT. General notes on use in hazardous areas according to UL-HazLoc WARNING EXPLOSION HAZARD DO NOT DISCONNECT WHILE CIRCUIT IS LIVE UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non- hazardous locations only. This equipment is suitable for use in

  • Siemens SCALANCE W774-1, Upkeep and maintenance 6.2 Restoring the factory settings SCALANCE W774-1 /W734-1 52 Operating Instructions, 01/2017, C79000-G8976-C325-08 6.2 Restoring the factory settings NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in a configured network with further consequences. With the reset button When pressing the button, make sure you adhere to the instructions in the section "Reset button". To reset the device to the factory defaults d

  • Siemens SCALANCE W774-1, Mounting 4.1 Wall mounting SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 29 Procedure 1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the drilling template. 2. Secure the device to the wall with two screws (M4). The screws are not supplied with the device. The type and length of the screws depend on the type of wall. 3. Mount the connecting cables and the antenna, see section "Connecting up (Page 35)".

  • Description of the device 3.4 Accessories SCALANCE W774-1 /W734-1 18 Operating Instructions, 01/2017, C79000-G8976-C325-08 3.4.1 Flexible connecting cables and antennas 3.4.1.1 Flexible connecting cables N-Connect/R-SMA flexible connecting cable for RJ-45 Flexible connecting cable for connecting an antenna to a SCALANCE W700. Preassembled wit

  • Siemens SCALANCE W774-1, Connection 5.3 Ethernet SCALANCE W774-1 /W734-1 42 Operating Instructions, 01/2017, C79000-G8976-C325-08 5.3 Ethernet The SCALANCE W774/W734 devices have two Ethernet interfaces located on the underside of the device. Depending on the version, either RJ-45 or M12 sockets are available. SCALANCE W774/W734 RJ-45 ① Ethernet interface P1 ② Ethernet interface P2 The power can also be supplied via this interface (Power over Ethernet). SCALANCE W774/W734 M12 EEC ① Ethernet interface P1 ② Ethernet interface P2

  • Siemens SCALANCE W774-1, Technical data 7.2 Technical specifications W774 M12 SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 57 Electrical data Power supply Supply voltage from terminal block/socket 24 VDC Safe Extra Low Voltage (SELV) Permitted range • +/- 20 % • +/- 30 % • 19.2 to 28.8 VDC (meets UL require- ments) • 16.8 to 31.2 VDC Design M12 socket Properties Electrically isolated, redundant design PoE to 24 VDC non-redundant design Supply voltage fr

  • Siemens SCALANCE W774-1, ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SIMATIC NET Industrial Wireless LAN SCALANCE W774-1 /W734-1 Operating Instructions 01/2017 C79000 -G8976-C325-08 Introduction 1 Security recommendations 2 Description of the device 3 Mounting 4 Connection 5 Upkeep and maintenance 6 Technical data 7 D

  • Siemens SCALANCE W774-1, SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 61 Approvals 9 You will find the approvals of the products in the reference work "Approvals SCALANCE W700 802.11n" on the Internet pages of Siemens Industry Online Support: ● Using the search function: support.automation.siemens.com (http://support.automation.siemens.com/WW/view/en) Enter the entry ID of the relevant manual as the search item. ● In the navigation panel on the left-hand side in the area "Industrial Com

  • Siemens SCALANCE W774-1, SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 27 Mounting 4 CAUTION Minimum distance to antennas Fit the device so that there is a minimum clearance of 20 cm between antennas and persons. WARNING If a device is operated in an ambient temperature of more than 50 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 50 °C.

  • Siemens SCALANCE W774-1, Connection 5.1 Lightning protection, power supply and grounding SCALANCE W774-1 /W734-1 36 Operating Instructions, 01/2017, C79000-G8976-C325-08 5.1 Lightning protection, power supply and grounding Lightning protection WARNING Danger due to lightning strikes Antennas installed outdoors must be within the area covered by a lightning protection system. Make sure that all conducting systems entering from outdoors can be protected by a lightning protection potential equalization system. When implementing your lightning protec

  • Siemens SCALANCE W774-1, Mounting 4.3 Installing on an S7-1500 standard rail SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 31 4.3 Installing on an S7-1500 standard rail Procedure Follow the steps below to fit the SCALANCE W774/W734 to an S7-1500 standard rail: 1. Place the device on the upper edge of the S7-1500 standard rail as shown in the figure. 2. Screw the housing to the S7-1500 standard rail. The required screw ships with the device. 3. Mount the connecting cables and the antenna, see section "Con

  • Description of the device 3.4 Accessories SCALANCE W774-1 /W734-1 20 Operating Instructions, 01/2017, C79000-G8976-C325-08 Type Properties Article number ANT793-8DK Directional antenna, mast/wall mounting, 23 dBi 5 GHz, 2 x N- Connect female 6GK5 793-8DK00-0AA0 ANT795-4MA Omni antenna, directly on the de- vice, 3/5 dBi 2.4 GHz and 5 GH

  • Siemens SCALANCE W774-1, Mounting 4.1 Wall mounting SCALANCE W774-1 /W734-1 28 Operating Instructions, 01/2017, C79000-G8976-C325-08 4.1 Wall mounting Drilling template The location of the holes for mounting the SCALANCE W774/W734 on a wall is shown in the following figure:

  • Siemens SCALANCE W774-1, Description of the device 3.3 Components of the product SCALANCE W774-1 /W734-1 14 Operating Instructions, 01/2017, C79000-G8976-C325-08 3.3 Components of the product The following components are supplied with the product: ● SCALANCE W774 or SCALANCE W734 ● 2 protective caps for the antenna sockets ● Only with device variant M12 – 3 protective caps for the M12 sockets ● Only with device variant RJ-45: – 4-pin terminal block for the power supply ● 1 screw for mounting on an S7-300 standard rail or S7-1500 standard rail ● SIMATIC NET Industrial Wireless LAN CD Please check that the consignment you have

  • Siemens SCALANCE W774-1, Connection 5.5 Replacing the PLUG (C-PLUG or KEY-PLUG) SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 47 Removing the PLUG Figure 5-1 Position of the slot for PLUG on the top of the SCALANCE W774/734 Follow the steps below to remove a PLUG from the device: 1. Turn off the power to the device. 2. Release the screw slot cover (position ①) and swing the slot cover to the side (position ②). 3. Insert a screwdriver between the front edge of the PLUG (Position ③) and the slot and release

  • Siemens SCALANCE W774-1, Description of the device 3.4 Accessories SCALANCE W774-1 /W734-1 Operating Instructions, 01/2017, C79000-G8976-C325-08 17 Energy cable Component Description Article number Energy cable 2 x 0.75 Energy cable for connection of signaling contact and power supply 24 VDC, stranded wire 2 x 0.75 mm 2 , capable of trail- ing, not assembled Sold by the meter 6XV1 812-8A Robust Energy Cable 4 x 0.75 Energy cable for connection of power supply 24 VDC, 4-wire stranded 4 x 0.75 mm 2 , robust, flexible, not assembled Sold by the meter 6XV1 801-2A M12 PLUG-IN CABLE Flexible plug-in power cable to connect the power supply 24 VDC, 4-wire, preassembled with a 4-pi

Related Products and Documents (Wireless Access Point):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Toshiba Satellite P100 Series Operation & user’s manual toshiba/satellite-p100-series-N89.pdf 25 Aug 2022 196 3.82 Mb
2 GE 20 Owner's manual and installation instructions ge/20-S71.pdf 10 Apr 2023 64 3.07 Mb
3 Akai PDP4206EA Product specifications akai/pdp4206ea-143.pdf 27 Jul 2022 2 0.36 Mb
4 IBM IntelliStation M Pro 9229 Installation manual ibm/intellistation-m-pro-9229-5O6.pdf 04 Dec 2022 72
5 Boss DR-220A Owner's manual boss/dr-220a-4LU.pdf 30 Jun 2022 44 0.9 Mb
6 Whirlpool Duet Steam WED9270X Use and care manual whirlpool/duet-steam-wed9270x-S8I.pdf 02 Sep 2023 28 3.02 Mb

Similar Resources:

  • Korenix

    JetWave 2640

    (5 pages)
    313A Beijer Electronics Group Companywww.korenix.comIP 67WMMIntel TDMA40KMBuilt-in 23dBi Antenna-30~70oCSupports both IEEE 802.11a 5.8GHz and 802.11b/g 2.4GHz bandUp to 54Mbps maximum net data rateHigh Gain 23dBi Panel Antenna maximizes transmission distance up to 40KMN type external Antenna slot Wireless QoS (WMM) for video precedence transmissionSupports B …
  • Dell

    W-IAP270 Series

    (20 pages)
    Dell Networking W-IAP270 Series Outdoor Instant Access PointInstallation Guide0511607-02 | August 2014 1The Dell W-IAP274 and W-IAP275 Instant Access Point (IAP) are environmentally hardened, outdoor rated, dual-radio IEEE 802.11ac wireless access points (AP). These Instant access points use MIMO (Multiple-Input, Multiple-Output) technology and other high-th …
  • Ubiquiti

    airFiber AF-5

    (32 pages)
    AF-5, AF-5U Quick Start Guidehttps://dl.ubnt.com/qsg/AF-5_AF-5U/AF-5_AF-5U_EN.html[2/17/2020 12:42:26 PM]airFiber AF-5/AF-5U I-Bracket Upper Mount Bracket withElevation RodLower Mount Bracket Pole Clamps (Qty. 2) M10x150 Carriage Bolts (Qty. 4)M10x100 Carriage Bolts (Qty. 2) Serrated Flange Bolts (Qty. 4) Stabilizer Brackets (Qty. 2)Serrated Flange Nuts (Qty …
  • EnGenius

    ENH200EXT

    (2 pages)
    ETI—Brands that communicateTM888.735.7888 www.engeniustech.comENH200EXTT H E L E A D E R I N L O N G R A N G E B U S I N E S S C L A S S W I R E L E S S D A TABusiness Class Outdoor Long Range Wireless N Access Point/Client/BridgeKey DifferentiatorsH I G H - P O W E R L O N G R A N G E C O V E R A G EMaximum 500mW power output provide …
  • Shure

    UA864

    (56 pages)
    © 2013 Shure IncorporatedPrinted in U.S.A27A20829 (Rev. 2)*27A20829*User GuideLe Guide de l’UtilisateurGuia del UsuarioGuida dell’UtenteBedienungsanleitungРуководство пользователя取扱説明書사용자 안내서用户指南GebruikershandleidingManuale d’usoPengguna PanduanWireless Accessory UA864 …
  • Conceptronic

    C54APM

    (9 pages)
    Setting repeater mode with 2x C54APM This manual will help you to set repeater mode on the C54APM. To create a Repeater environment, you need 2x C54APM. 1 of the C54APM will function as a normal Access point in your wireless network, and the other C54APM will function as a Repeater, for a bigger distance in your network. Important Notes: • You need a …

Comments, Questions and Opinions: