Siemens RUGGEDCOM RSG2488 Installation Manual
|
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 2 Installing the Device Configuring the Device 19 Section2.10 Configuring the Device Once the device is installed and connected to the network, it must be configured. All configuration management is done via the RUGGEDCOM ROS interface. For more information about configuring the device, refer to the RUGGEDCOM ROS User Guide associated with the installed software release.
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 5 Dimension Drawings 37 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 376.0 442.4 44.0 Figure22:Overall Dimensions
Siemens RUGGEDCOM RSG2488, Chapter 3 Modules RUGGEDCOM RSG2488 Installation Guide 24 Available Modules RUGGEDCOM RMM2473-4M12X Specifications Ports: 4 Port Type: M12 (8-Pin, X-Coded) Speed: 1000 Mbps Interface: TX Distance: 100 m (328 ft) Article Numbers 6GK6000-8CG04-4EA0 (Standard) 6GK6000-8CG04-4EA1 (Conformal Coated) Fiber Optic Ethernet Modules RUGGEDCOM RMM2464-4ST2 Specifications Ports: 4 Port Type: ST Mode: MM (Multi-Mode) Speed: 100 Mbps Interface: FX Wavelength: 1310 nm Distance: 2 km (1.2 mi) Article Numbers 6GK6000-8FX01-4EA0 (Standard) 6GK6000-8FX01-4EA1 (Conformal Coated) RUGGEDCOM RMM2465-4ST20 Specifications Ports: 4 Port Type: ST Mode: SM (Single-Mode) Speed:
Chapter 2 Installing the Device RUGGEDCOM RSG2488 Installation Guide 18 Connecting to the Device IMPORTANT! The serial console and management (MGMT) ports are intended to be used only as temporary connections during initial configuration or troubleshooting. The serial console port implements RS-232 DCE (Data Communication Equipment) on a DB9 connector. The following is the pin-out for the port
RUGGEDCOM RSG2488 Installation Guide Chapter 6 Certification ACMA 43 • CAN ICES-3 (A)/NMB-3 (A) Section6.1.5 ACMA This device meets the requirements of the following Australian Communications and Media Authority (ACMA) standards under certificate ABN 98 004 347 880: • Radiocommunications (Compliance Labelling – Devices) Notice 2014 made under Section 182 of the Radiocommun
RUGGEDCOM RSG2488 Installation Guide Chapter 6 Certification EMC and Environmental Type Tests 45 Test Description Test Levels Severity Levels IEC 61000-4-10 Damped Oscillating Magnetic Field Enclosure Ports 100 A/m for 1 s (100 kHz and 1 MHz) 5 IEC 61000-4-11 Voltage Dips and Interrupts AC Power Ports 30% for 1 period 60% for 50 periods 100% for 5 periods 100% for
Chapter 2 Installing the Device RUGGEDCOM RSG2488 Installation Guide 16 Inserting/Removing the MicroSD Card + + + + Figure12:Dual Low DC Power Supply Figure13:High AC/DC Power Supply and Low DC Power Supply Section2.8 Inserting/Removing the MicroSD Card The RUGGEDCOM RSG2488 accepts a microSD card for storing configuration files and/or sof
Siemens RUGGEDCOM RSG2488, Chapter 6 Certification RUGGEDCOM RSG2488 Installation Guide 46 EMC and Environmental Type Tests Description Test Levels AC Power Ports Signal Ports 2 kV DC Power Ports 1.5 kVDC Dielectric Strength AC Power Ports 2 kV Signal Ports DC Power Ports AC Power Ports ± 4 kV at 2.5 and 5 kHzFast Transient Earth Ground Ports ± 4 kV at 5 kHz Signal Ports 2.5 kV Common Mode at 1MHz DC Power Ports Oscillatory AC Power Ports 2.5 kV Common Mode 1 kV Differential Mode at 1 MHz Radiated RFI Enclosure ports 35 V/m Enclosure Contact ± 2 kV ± 4 kV ± 8 kV ESD Enclosure Air
Siemens RUGGEDCOM RSG2488, Chapter 2 Installing the Device RUGGEDCOM RSG2488 Installation Guide 6 General Procedure Section2.1 General Procedure The general procedure for installing the device is as follows: 1. Review the relevant certification information for any regulatory requirements. For more information, refer to Section6.1, “Approvals”. 2. Review the RUGGEDCOM RSG2488 Modules Catalog for special installation or regulatory requirements related to the modules installed in the device. In the case of Precision Time Protoc
Siemens RUGGEDCOM RSG2488, Chapter 3 Modules RUGGEDCOM RSG2488 Installation Guide 32 Installing/Removing Power Modules 6. Turn on power to the module and confirm the module is receiving and supplying power. This is indicated by the LEDs on the module. LED State Description O Green The module is supplying power I Green The module is receiving power
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 3 Modules Installing/Removing Power Modules 31 2 3 1 Figure20:Removing a Power Supply 1.Screws 2.Power Supply 3.Chassis 3. Turn off power to the module. 4. Disconnect the power supply wiring from the terminal block. Alternatively, for convenience, remove the terminal block with the wiring still connected and set it aside to be connected later to the new module. 5. Install a new or blank module to prevent the ingress of dust and dirt
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 3 Modules Installing/Removing Line Modules 29 Removing a Module To remove a line module, do the following: 1. Make sure power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate. 2. [Optional] If the device is installed in a rack, remove it from the rack. 3. Loosen the screws that secure the module. 4. Pull the module from the chassis to disconnect it. 3 1 2 Figure18:Removing a Module 1.Module 2.Chassis 3.Screw 5. Install a
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 1 Introduction Feature Highlights 1 Introduction The RUGGEDCOM RSG2488 is a utility grade, fully managed, industrial Ethernet switch designed to operate reliably in harsh environments. With a rugged metal enclosure and an optional conformal coating, the RUGGEDCOM RSG2488 provides a high level of immunity to electromagnetic interference and heavy electrical surges, and can withstand temperatures between -40 and 85 °C (-40 and 185 °F). Highly modular, the RSG2488 switch supports
Siemens RUGGEDCOM RSG2488, Chapter 6 Certification RUGGEDCOM RSG2488 Installation Guide 42 European Union (EU) Section6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: • EN 60950-1 Information Technology Equipment – Safety – Part 1: General Requirements • EN 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments • EN 60825-1 Safety of Laser Products – Equipment Classification and Requirements • EN 55022 Information Technology Equipment – Radio disturbance characteristics – Limits an
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 6 Certification Approvals 41 Certification The RUGGEDCOM RSG2488 device has been thoroughly tested to guarantee its conformance with recognized standards and has received approval from recognized regulatory agencies. NOTE Certifications related to individual modules are detailed in the RUGGEDCOM Modules Catalog for the device available online. CONTENTS • Section6.1, “Approvals” • Section6.2, “EMC and Environmental Type Tests” Section6.1 Approvals The following details the approvals issued for the RUGGEDCOM RSG2488. CONTENTS • Section6.1.1, “TÜV SÜD” • Section6.1.2, “European Union (EU)�
Siemens RUGGEDCOM RSG2488, Chapter 2 Installing the Device RUGGEDCOM RSG2488 Installation Guide 14 Wiring Examples 2 4 1 6 3 5 4 5 6 3 7 7 7 7 Figure8:DC Terminal Block Wiring 1.Screw-Type Terminal Block for 24 and 48 Power Supply 2.Pluggable Terminal Block for 24P and 48P Power Supply 3.Positive Terminal for PS1 4.Negative Terminal for PS1 5.Positive Terminal for PS2 6.Negative Terminal for PS2 7.Chassis Ground 2. Connect the negative wire from the power source to the negative terminal on the terminal bl
Siemens RUGGEDCOM RSG2488, Chapter 3 Modules RUGGEDCOM RSG2488 Installation Guide 30 Installing/Removing Power Modules 3 1 2 Figure19:Installing a Module 1.Module 2.Chassis 3.Screw 5. Tighten the screws to secure the module. 6. [Optional] If necessary, install the device in the rack. 7. Connect power to the device. Section3.3 Installing/Removing Power Modules The RUGGEDCOM RSG2488 supports dual redundant power supply modules. CAUTION! Contamination hazard – risk of equipment damage. Prevent the ingress of water, dirts and other debris that may lead to premature equipment failure. Always make sure slots a
Siemens RUGGEDCOM RSG2488, RUGGEDCOM RSG2488 Installation Guide Chapter 5 Dimension Drawings 39 490.6 134.5 277.4 98.6 25.4 51.6 7.6 148.3 227.7 480.5 160.0 1 Figure24:Panel and Din Rail Mount Dimensions 1.DIN Rail Centerline 110.0 91.4 21.8 104.1 Figure25:4-Port Line Module Dimensions
Siemens SIMATIC NET CP 343-1 Switch Operation & user’s manual
SIMATIC NET CP 343-1 |
Siemens HiPath 1100 Switch Operation & user’s manual
HiPath 1100 |
Siemens SCALANCE X-200RNA Switch Operating instructions manual
SCALANCE X-200RNA |
Siemens SITRANS LVL200E Switch Operating instructions manual
SITRANS LVL200E |
Siemens PM-E F pm DC24V PROFIsafe Switch Installation and operating manual
PM-E F pm DC24V PROFIsafe |
Siemens S 563 Switch Quick start manual
S 563 |
Siemens SITRANS LPS200 Switch Operating instructions manual
SITRANS LPS200 |
Siemens HUB-4 Switch Installation instructions manual
HUB-4 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Curtis | DPF151 | Specification sheet | curtis/dpf151-6E8.pdf | 02 Sep 2022 | 1 | 0.08 Mb |
2 | Snapper | LE | Set-up instructions & pre-operation checklist | snapper/le-WW9.pdf | 15 Sep 2023 | 2 | 0.05 Mb |
3 | Pride | Jazzy 610 2SP | Owner's manual | pride-mobility/jazzy-610-2sp-3O2.pdf | 27 Dec 2023 | 43 | |
4 | CYP | CLUX-SDI2VS | Operation manual | cyp/clux-sdi2vs-88B.pdf | 25 Aug 2023 | 16 | |
5 | Fiesta | 259.162190 | Assembly and operation manual | fiesta/259-162190-4IG.pdf | 11 Oct 2023 | 36 | 16.95 Mb |
6 | BOXLIGHT | MP-56t | Operation & user’s manual | boxlight/mp-56t-86U.pdf | 18 Jul 2023 | 48 |
TMB
ProPlex GBS 5-Port Ethernet Switch Quick Start Guide TMB 24/7 Technical Support US/Canada: +1 818.794.1286 Toll Free: 1 877.862.3833 (877.TMB.DUDE) UK: +44 (0)20.8574.9739 Toll Free: 0800.652.5418 v.1.0 rev 070819 e-mail: [email protected]
…
ProPlex GBS(5 pages) |
Digitus
USB 2.0 Sharing Switch User Manual Model: DA-70135-1 & DA-70136-1 Getting started with USB 2.0 Sharing Switch Thank you for choosing the USB 2.0 Sharing Switch. Today, USB connections can be found in various devices, from PC cameras to scanners, printers, Hubs, and KVM switches, As USB technology continues its reign in the computer periphe …
DA-70135-1(8 pages) |
SIIG
USB Over IP User User User User User’’’’’s Manuals Manuals Manuals Manuals ManualSIIG’SIIG’SIIG’SIIG’SIIG’s ONLINE SUPPORs ONLINE SUPPORs ONLINE SUPPORs ONLINE SUPPORs ONLINE SUPPORT andT andT andT andT andProduct RegistrationProduct RegistrationProduct RegistrationProduct RegistrationProduc …
USB Over IP(60 pages) |
Setra Systems
IntroductionThe Sure-Set Current Switch (SSC) Series of digital output switches are noninva-sive devices designed to detect current owing through a cable or wire. A cost eective solution for monitoring on and o status or proof of operation, these devices are ideal for monitoring the cur-rent load on motors driving fans, pumps, chillers, compressors …
SSC-2S(4 pages) |
Nortel
Carrier Networking Services V15K_2.0.0.0Part No. 302773-E Rev 00July 20004401 Great America ParkwaySanta Clara, CA 95054Known Anomalies for the Versalar Switch Router 15000
…
15000(18 pages) |
Freedom9
Quick Install GuidefreeConnect500Revision 1.1 Specifications are subject to change without notice. Copyright 2007 Freedom9 Inc.freedom to succeedThe Switch’s 5 ports1. Network Ports: Ports 1 to 5 located on the back of the switch are used to connect the switch to your computers using Ethernet cables with RJ-45 connec-tors. (Figure 1).2. Power: The AC powe …
freeConnect 500(1 pages) |
Electrolux Freezer ERN28700User Guide: Electrolux ERN28700 (54ATWR, Upd.03.01.2024) ERN28700, 24 |
Labelmate Printer Accessories MC-11PDF User Manual (@28DMG2), Labelmate MC-11 Printer Accessories (Sunday 15-10-2023) MC-11, 2 |
Sony Laptop PCG-TR3ALaptop Specifications (Sony PCG-TR3A) PCG-TR3A, 1 |
Sima Remote Control VS-502Remote Control Operation & user’s manual (Sima VS-502) VS-502, 24 |
Caffitaly System Coffee Maker S14Caffitaly System Coffee Maker Quick start manual (File: caffitaly-system-s14-quick-start-manual-2, 08.02.2024) S14, 2 |
MyPressi Coffee Maker TwistTwist (Coffee Maker ePDF Manual, #8GZA56) Twist, 13 |
Sharp Software AR-NS1AR-NS1 Operation manual - C54L1N AR-NS1, 48 |
Havells Water Heater Quatro-15 LWater Heater PDF Operating instructions manual Quatro-15 L, 7 |
Rice Lake Kitchen Appliances 920iRice Lake 920i Guide (Operation manual), @URH2IW 920i, 14 |
Lucent Technologies Telephone Merlin Legend MLX-5Telephone PDF Operation & user’s manual Merlin Legend MLX-5, 22 |
Carrier Heat Pump 38CQ38CQ Installation, start-up and service instructions manual - 1UE7N6 38CQ, 22 |
Xerox Printer 6100BD - Phaser Color Laser PrinterXerox 6100BD - Phaser Color Laser Printer Guide (Doc Type: Printer Manual ) 6100BD - Phaser Color Laser Printer, 34 |