  • Siemens CERBERUS PYROTRONICS ADB-3, INTRODUCTION Model ADB-3 The CERBERUS PYROTRONICS TM Model ADB-3 Audible Base consists of a standard Series 3 base combined with an audible device. All field wiring terminates at a four position terminal block located on the back of the unit. The ADB-3 is used only with Series 3 detectors and is powered directly from the zone circuit. (Refer to Table 1 for compatible detector model numbers and the related Installation Instructions.) The audible device sounds when the detector alarms and stops sounding when the system is reset. (Refer to Figure 1, the ADB-3 Wiring Diagram.) Only one device is guaranteed to activate per zone. The ADB-3 i

  • 2 Several different configurations can provide audible signal circuit power to the ADBI-60 at terminals 1 through 4, as shown in Figures 2, 3, 4, 5, 6, 7, and 8. During the supervisory state (no alarms), the polarity of the power to all ADBI-60s is in a reversed (off-normal) state, resulting in zero current flow to each base. Any alarm reported to System XL3 or System MXL/MXL-IQ activates the TR

  • Siemens CERBERUS PYROTRONICS ADB-3, 3 CAUTION: The ADBI-60 is used for primary building evacuation; NFPA 72 requires that the source of audible power be capable of operat- ing all primary evacuation audibles at the same time. ELECTRICAL RATINGS AND CONSTRAINTS Model ADB-3 Voltage Rating: On AC: 28-48 VDC peak, full wave On battery: 20-27 VDC Current: Supervisory – 0A Alarm – 13mA at 25 VDC Constraint: Only one device is guaranteed to activate per zone. Model ADBI-60 Voltage Rating: 25 ± 5 VDC Current: Supervisory – 0A Alarm – 37mA at

  • Siemens CERBERUS PYROTRONICS ADB-3, 9 Figure 7 Installation/Wiring Diagram for ADBI-60 Audibles Powered by IXL System Figure 8 Installation/Wiring Diagram for ADBI-60 Audibles Powered by a Remote Power Supply (System IXL) 1.Set the CE-S address to 201 to follow the System alarm relay. 2.Only detectors attached to the ICON-1 can be used with the ADBI-60. 3.The ADBI-60 turns on when its associated detector goes into alarm. 4.The UL listed power supply with battery backup is rated at 24 VDC. It must supply enough current to handle at least 10% of the ADBI-60s c

  • Siemens CERBERUS PYROTRONICS ADB-3, 10 6. The ADBI-60 is powered by System MXL/MXL-IQ (Figures 5 and 6); the System power for indicating appliances is 5A. If more than 5A is required, use the configuration in Figure 3 or Figure 4 for auxiliary power. See Note above. 7. Connect terminal 6 of the PS-35 (Figures 3 and 4) to the minus DC side of the System XL3 or MXL/MXL-IQ main power supply for proper ground fault supervision. 8. The ADBI-60 is powered by System IXL (Figure 7); the System power on indicating appliances is 3A. If more than 3A is required, use the configuration in Figure 8. 9. Each audible base is marked as follows to indicate its type (ADBI-60 or ADB-3): Note: For additional information on th

  • Siemens CERBERUS PYROTRONICS ADB-3, 11 DETECTOR INSTALLATION INSTRUCTIONS ADBI-60 Base [for MXL/MXL-IQ and IXL (ICON-1)] FP-11 w/DB-ADPT P/N 315-095921-3 FPT-11w/DB-ADPT P/N 315-095921-3 ID-60I P/N 315-090287-2 ID-60IA P/N 315-090287-2 ID-60IAH P/N 315-090287-2 ID-60IH P/N 315-090287-2 ID-60T P/N 315-090288-2 ILP-1 P/N 315-092594-3 ILP-2 P/N 315-095028-3 ILPT-1 P/N 315-092594-3 ILT-1 P/N 315-093336-1 ADBI-60 Base (for XL3) DI-X3 P/N 315-083534D DI-X3H P/N 315-086587B DI-AX3 P/N 315-085388F DI-AX3H P/N 315-086588B DT-X3 P/N 315-084125C ILP-1 P/N 315-092594-3 ILPT-1 P/N 315-092594-3 ADB-3 Base DI-3 P/N 315-081943-15 DI-3H P/N 315-081943-15 DI-A3 P/N 315-08194

  • Mounting the Detector Base 1. Route all wires out from the outlet box. 2. When the alarm LED viewing is critical, position the LED mark on the base in the intended direction (Refer to Figure 9). 3. Make connections directly to the audible base terminals located on the back of the base. Refer to the related lnstallation/Wiring Diagram above. 4. After all bases are installed, including the

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kramer VP-210XL Operation & user’s manual kramer/vp-210xl-7X3.pdf 18 Jan 2023 11
2 Soleus Air PE6-10R-03 Operating instructions manual soleus-air/pe6-10r-03-1JI.pdf 18 Sep 2022 14 0.88 Mb
3 Broil King POV-003 Instruction manual broil-king/pov-003-C6R.pdf 02 Jul 2023 13 0.6 Mb
4 TRENDnet TE100-PS3plus Specifications trendnet/te100-ps3plus-1TV.pdf 08 Jul 2022 2 0.19 Mb
5 Roland Workstation GW-8 Implementation manual roland/workstation-gw-8-2LD.pdf 30 Sep 2022 10 0.27 Mb
6 Insignia NS-32E320A13A Important information manual insignia/ns-32e320a13a-SPH.pdf 02 Aug 2022 8

Similar Resources:

  • Paradox

    MG5050

    (76 pages)
    PARADOX.COM Programming Guide32-Zone Wireless Transceiver Security SystemsMG5000 V3.2MG5050 V3.25- to 32-Zone Expandable Security SystemsSP5500 V3.2SP6000 V3.2SP7000 V3.2Always Armed, Never Disarmed …
  • Velleman

    PEM7D

    (23 pages)
    PEM MINI INMINI IRSYSTEMMINI SIMINI-IR USER MAGEBRUIKNOTICE DMANUAL BEDIENU M7D NFRARED SECUR BEVEILIGINGE MINI IR DE STEMA DE PROR-SICHERHEITANUAL KERSHANDLEIDID’EMPLOI DEL USUARIO UNGSANLEITUNGURITY SYSTEMGSSYSTEEM, PROTECTION OTECCIÓN IR TSSYSTEM 3ING 6912G 16M 36926 …
  • Miranda

    KMV-3901

    (37 pages)
    Kaleido Remote Control Protocol (Gateway) User’s Guide M770-0900-115Copyright 2011 Miranda Technologies Inc. Specications may be subject to change Printed in Canada Nov. 2011 MirandaTechnologies Inc.3499 Douglas-B.-FloreaniSt-Laurent, Québec, Canada H4S 2C6Tel. 514-333-1772 Fax. 514-333-9828 www.miranda.com Multi-ImageDisplayProcessorKaleido Remote Co …
  • TDCom

    IRITRACK KIT

    (2 pages)
    To drive with an Iritrack - security system and satellite tracking - you need a fitting kit for bike/quad including the power cable and the antenna cables + GPS and Iridium antenna. The bracket has to be ordered separately: you can install your Iritrack on your bike or quad with several types of brackets: KIT COMPOSIT …
  • Ingersoll-Rand

    VON DUPRIN 33 Series

    (8 pages)
    Installation Instructions33/35 and 98/99 SeriesALK Alarm KitIndex:• General Information ...................... 2• Parts List ............................................ 2• Installation ....................................... 3• Operating Instructions .................. 6• Changing the Battery..................... 7• EI (External Inhibi …
  • WamBlee

    W470

    (60 pages)
    W470W470EXEd. 1.0.0 (EU)10/2017Manual de instruçõesManual del usuarioManuel d'instructionManuale d'usoInstruction manualBedienungsanleitungHandleiding …

Comments, Questions and Opinions: