  • RUGGEDCOM MX5000RE Installation Guide Chapter 5 Dimension Drawings 45 Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 175.3 25.4 177.8 479.8 469.6 133.4 117.6 101.6 12.7 16.0 16.0 31.8 5.8 10.9 446.8 441.7 221.5 311.9 Figure 43: MX5000 Overall Dimensions

  • Siemens RUGGEDCOM MX5000RE, Chapter 1 Introduction RUGGEDCOM MX5000RE Installation Guide 2 Feature Highlights • VPN/IPSEC • Role-based access control Ethernet Ports • Up to 48 copper ports • Up to 48 100Base-FX optical ports • Up to 2 Gigabit Ethernet ports • Long-haul optics allow distances up to 90 km (56 mi) • Multiple connector types: ST, MTRJ, LC, SC Reliability in Harsh Environments • Immunity to EMI and high voltage electrical transients: ▪ Zero-Packet-Loss Technology ▪ Meets IEEE 1613 (electric utility substations) ▪ Exceeds IEC 61850-3 (electric utility subs

  • RUGGEDCOM MX5000RE Installation Guide ii Copyright © 2014 Siemens Canada Ltd. All rights reserved. Dissemination or reproduction of this document, or evaluation and communication of its contents, is not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration. This documen

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 3 Communication Ports Connecting Multiple RS485 Devices 39 1 2 3 Figure 41: Removing a Module 1. Chassis 2. Module 3. Screw 5. Install a new module or a blank module (to prevent the ingress of dust and dirt). For more information, refer to Section 3.6.1, “Installing a Module”. 6. If necessary, install the device in the rack. 7. Connect power to the device. Section 3.7 Connecting Multiple RS485 Devices Each RS485 port can communicate with multiple RS485 devices by wiring devices together in sequence over a single twisted pair with transmit and receive sig

  • Siemens RUGGEDCOM MX5000RE, Chapter 6 Certification RUGGEDCOM MX5000RE Installation Guide 48 FCC Compliance Section 6.3 FCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipmen

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Table of Contents iii Table of Contents Preface ................................................................................................................ v Alerts .................................................................................................................................................. v Related Documents ............................................................................................................................. v Accessing Document

  • Siemens RUGGEDCOM MX5000RE, Chapter 2 Installing the Device RUGGEDCOM MX5000RE Installation Guide 16 Assembling the MX5000 and MX5000RE 3. Starting at the overlapping section of a patch panel groove, gently press a length of gasket material into the groove. Work around the groove until the gasket is seated all around the opening and in the overlapping section. Make sure the gasket material is loose and is not stretched during installation. 2 1 Figure 13: EMI Gasket Installation 4. Trim the gasket material to length. 5. Repeat Step 3 and Step 4 for e

  • Siemens RUGGEDCOM MX5000RE, Chapter 4 Technical Specifications RUGGEDCOM MX5000RE Installation Guide 44 Operating Environment Section 4.6 Operating Environment Parameter Range Comments Ambient Operating Temperature -40 to 85 °C (-40 to 185 °F) Measured from a 30 cm (12 in) radius surrounding the center of the enclosure. Ambient Relative Humidity 5% to 95% Non-condensing Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F) Section 4.7 Mechanical Specifications Parameter Value Dimensions Refer to Chapter 5, Dimension Drawings. Weight (MX5000) 14-16 kg (30-35 lbs) Weight (Enclosure) 68 kg (150 lbs) Ingress Protection (MX

  • Siemens RUGGEDCOM MX5000RE, Chapter 6 Certification RUGGEDCOM MX5000RE Installation Guide 50 EMI and Environmental Type Tests Test Description Test Levels Earth ground ports +/- 4 kV Signal ports 2.5 kV common mode @1 MHz DC Power ports 2.5 kV common, 1 kV differential mode @ 1 MHz Oscillatory AC Power ports 2.5 kV common, 1 kV differential mode @ 1 MHz Signal ports 5 kV (Fail-Safe Relay output) DC Power ports 5 kV IEEE C37.90.1 HV Impulse AC Power ports 5 kV Signal ports 2 kVAC DC Power ports 2 kVDC Dielectric Strength AC Power ports 2 kVAC Environmental Ty

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 2 Installing the Device Installing the EMI Gaskets 15 2 1 Figure 12: Mounting Brackets 1. Mounting Bracket 2. #10-32×1/2" Flat Head Hex Socket Screw 2. Secure the mounting bracket with 20 flat head hex socket screws. Hand tighten each screw and make sure each screw head is flush with the surface of the mounting bracket. 3. Repeat Step 1 and Step 2 for the mounting bracket on the opposite side of the MX5000. Section 2.1.6 Installing the EMI Gaskets The material for the EMI (Electro-Magnetic Interference) gaskets is provided in two lengths for the two different sizes of patch panel openings in the MX5000: EMI Gasket Material Leng

  • Siemens RUGGEDCOM MX5000RE, Chapter 3 Communication Ports RUGGEDCOM MX5000RE Installation Guide 40 Connecting Multiple RS485 Devices < 1219 m (4000 in) 120Ω 10nF 120Ω 10nF 1 2 3 5 5 6 4 Figure 42: Recommended RS485 Wiring 1. MX5000RE Device 2. Common (Isolated Ground) 3. Negative 4. Positive 5. Shield to Earth (Connected At a Single Point) 6. RS485 Devices (32 Total)

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 3 Communication Ports 31 Communication Ports The MX5000 can be equipped with various types of communication ports to enhance its abilities and performance. Each set of communication ports is part of a field replaceable module that makes switching ports fast and easy. Use the ROX II software to determine which ports are equipped on the device. For more information, refer to the ROX II User Guide for the RX5000. Each type of module has a specific location in the MX5000 chassis. 1 2 3 4 5 6

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 3 Communication Ports Removing an SFP Optical Port 37 Section 3.5.2 Removing an SFP Optical Port To remove an SFP optical port, do the following: CAUTION! Electrical hazard – risk of damage to equipment. Make sure all electrostatic energy is dissipated before performing installing or removing components from the device. An electrostatic discharge (ESD) can cause serious damage to the component once it is outside the chassis. 1. Make sure all potential electrostatic build-up has been properly discharged to prevent electrostatic discharges (ESD). This can be accomplished by wearing an ESD wrist strap or by touching Earth o

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 1 Introduction Feature Highlights 1 Introduction The RUGGEDCOM MX5000RE is a MIL-STD, high-port density routing and switching platform, designed to operate in the most demanding environments.The MX5000RE can withstand high levels of electromagnetic interference, radio frequency interference, and a wide temperature range of -40 to 85 °C (-40 to 185 °F). The MX5000RE is designed to meet the challenging climatic and environmental demands found in utility, industrial, and military network applications. The MX5000RE's superior hardware design, coupled with the embedded MX500

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 3 Communication Ports Fiber Optic Ethernet Ports 35 For specifications on the available copper Ethernet ports, refer to Section 4.3, “Copper Ethernet Port Specifications”. Section 3.4 Fiber Optic Ethernet Ports Fiber optic Ethernet ports are available with either MTRJ (Mechanical Transfer Registered Jack), LC (Lucent Connector), SC (Standard or Subscriber Connector) or ST (Straight Tip) connectors. Make sure the Transmit (Tx) and Receive (Rx) connections of each port are properly connected and matched to establish a proper link. 21 Figure 33: MTRJ Port 1. Tx Connector 2. Rx Connector 21

  • Siemens RUGGEDCOM MX5000RE, RUGGEDCOM MX5000RE Installation Guide Chapter 2 Installing the Device Assembling the MX5000RE 7 Installing the Device The following sections describe how to install the device, including mounting the device, connecting power, and connecting the device to the network. DANGER! Electrocution hazard – risk of serious personal injury and/or damage to equipment. Before performing any maintenance tasks, make sure all power to the device has been disconnected and wait approximately two minutes for any remaining energy to dissipate. WARNING! Burn hazard – risk of serious personal injury. Avoid contact with the surface of the unit. The metal surface may be hot due to the high allowable am

  • Chapter 2 Installing the Device RUGGEDCOM MX5000RE Installation Guide 12 Connecting the Failsafe Relay NOTE The other end of the grounding cable will be connected to the inside of the enclosure in later steps. Section 2.1.3 Connecting the Failsafe Relay The failsafe relay on the Control Module (CM) can be configured to latch based on alarm conditions. The NO (Normally Open) cont

  • Siemens RUGGEDCOM MX5000RE, Chapter 2 Installing the Device RUGGEDCOM MX5000RE Installation Guide 22 Mounting the MX5000RE Figure 18: Front Panel Installation WARNING! Crushing hazard – risk of serious injury or damage to equipment. Make sure the front panel is properly supported at all times. It is highly recommended to employee the assistance of another technician. 2. Position the front panel over the MX5000RE opening, aligning the panel with the two (2) locating pins on the front face. 3. Secure the front panel with 24 screws. Hand-tighten the screws evenly in a cross pattern. Section 2.1.12 Mounting the MX5000RE To mount the fully assembled MX5000RE to its final

  • Chapter 1 Introduction RUGGEDCOM MX5000RE Installation Guide 4 Patch Panels 43 5 6 1 1 2 Figure 2: Front Panel 1. Power Module Indicator LEDs 2. Alarm Indicator LEDs 3. Utility USB Port 4. Management Ethernet Port 5. Lamp Test/Alarm Cut- Off (LT/ACO) Button 6. RS232 Serial Console Port (DB9) Power Module Indicator LEDs These LEDs indicate the status of the

Related Products and Documents (Switch):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Zanussi ZCL911W Instruction booklet zanussi/zcl911w-9TY.pdf 21 Apr 2023 13 0.44 Mb
2 ActionTec GT701D Quick start manual actiontec/gt701d-NVF.pdf 26 Jan 2024 2 0.37 Mb
3 Kramer VP-719DS Operation & user’s manual kramer/vp-719ds-1QI.pdf 21 Sep 2022 41
4 Meridian 500 Operation & user’s manual meridian/500-S3B.pdf 06 Mar 2023 32
5 Conair S1RCSC Instruction & styling manual conair/s1rcsc-SM7.pdf 22 Aug 2022 6 0.41 Mb
6 JVC AV-28BT8EEB Instructions manual jvc/av-28bt8eeb-TIL.pdf 09 Aug 2023 14

Similar Resources:

  • LEGRAND

    LEXIC 037 23

    (4 pages)
    LEXICTM• Interrupteur crépusculaire à cellule déportée• Lichtgevoelige schakelaar met verplaatste fotocel • Light sensitive switch with remote electric eye• Dämmerungsschalter mit separatem Lichtfänger • Interruptor crepuscular con célula separada • Interruttore crepuscolare con cellula fotoelettricaesterna • Interruptor crepuscular com …
  • D-Link

    DI-713

    (5 pages)
    Rev: 10102000D-LinkDI-713 Quick Installation Guide1. Hardware InstallationA. Setup the LAN connection:1. Wired LAN connection: connect an Ethernet cable from your computer’sEthernet port to one of the LAN ports of the DI-713.2. Wireless LAN connection: make sure the antennas are in a vertical position (ifnot, rotate more than 90 degrees).B. Power on: …
  • HPE

    5820X Series

    (259 pages)
    HPE 5820X & 5800 Switch Series Network Management and Monitoring Configuration Guide Part number: 5998-7395R Software version: Release 1810 Document version: 6W100-20160129 …
  • Allied Telesis

    AT-x930-28GTX

    (158 pages)
    613-002100 Rev. Cx930 SeriesGigabit Layer 3 Ethernet SwitchesAT-x930-28GTXAT-x930-28GPXAT-x930-28GSTXAT-x930-52GTXAT-x930-52GPXInstallation Guide for Stand-aloneSwitches …
  • HP

    4400

    (2 pages)
    HP Controller EnclosureManagement ModuleReplacement Instructions© Copyright 2009 Hewlett-Packard Development Company, L.P.Second edition: May 2011The information in this document is subject to change without notice.Printed in Puerto Ricowww.hp.com*593094-001*About this documentFor the latest documentation, go to http://www.hp.com/support/manuals, and select …
  • IBM

    E

    (40 pages)
    IBM BladeCenter S Distributed, small office, easy to configure IBM BladeCenter E Best energy efficiency, best density IBM BladeCenter T Ruggedized IBM BladeCenter H High performance IBM BladeCenter HT Ruggedized, high performance IBM BladeCenter Chassis Product Guide September 2008 …

Comments, Questions and Opinions: