Manualios.com

Siemens SIMOTION P320-4 E Commissioning And Hardware Installation Manual

  • SIMOTION P320-4 E Industrial PC
  • ma71V1uyttdHs
  • Commissioning And Hardware Installation Manual
  • PDF / Adobe Acrobat Reader
  • 148

Siemens SIMOTION P320-4 E Manual Online:

4.5, 2561 votes
Siemens SIMOTION P320-4 E User Manual
Siemens SIMOTION P320-4 E User Guide
Siemens SIMOTION P320-4 E Online Manual

Text of Siemens SIMOTION P320-4 E User Guide:

  • Siemens SIMOTION P320-4 E, WARNING Danger to life from touching live parts on damaged devices Improper handling of devices can result in damage. For damaged devices, hazardous voltages can be present at the enclosure or at exposed components; if touched, this can result in death or severe injury. ● Observe the limit values specified in the technical specifications during transport, storage, and operation. ● Do not use damaged devices. WARNING Danger to life through electric shock due to unconnected cable shields Hazardous touch voltages can occur through capacitive cross-coupling due to unconnected cable shields. ● As a minimum, connect cable shie

  • 7.1.5 Function elements Functions of the buttons Below the current SIMOTION P320-4 status display, you will find a selection of buttons which can only be operated with administrator rights. Description of the button functions: Table 7-2 Function of the buttons in SIMOTION P State Button Function Restart Restarting SIMOTION P320-4. The information in the SRAM is retained. If R

  • Mounting 4 4.1 Installation overview The SIMOTION P320‑4 is installed in a control cabinet or in a controller housing. Operating mode The following operating modes are available for a SIMOTION P320‑4: ● SIMOTION P320‑4 (headless) ● Distributed configuration of the SIMOTION P320‑4 with a remote panel. 4.2 Important information about installation When installing th

  • Siemens SIMOTION P320-4 E, Service and maintenance 10 10.1 Recording diagnostic data Diagnostics data can be recorded during ramp-up and operation for the diagnostics and error analysis. Backing up diagnostic data Following a fault on a SIMOTION device, diagnostic data (e.g. diagnostic buffer content, up- to-date content of HTML pages, etc.) can provide important information on the cause of the fault. The diagnostic data can be recorded during ramp-up or operation and backed up on the external CFast card by means of a simple operation as described below. You have the following options for the backed-up diagnostic data: ● copy from the external CFast card or ● download using SIMOTION IT or FTP. Savi

  • Siemens SIMOTION P320-4 E, 8.3.5 License tab The License tab can be used ● To view currently installed licenses ● To enter new License Keys. Figure 8-4 License tab This tab displays the licenses currently installed on this hardware. If you wish to modify the licensing of this hardware, click the Licensing button. The License Manager dialog box is displayed; here you enter a new License Key. Parameter assignment/addressing 8.3 SIMOTION P control manager SIMOTION P320-4 E / P320-4 S 78 Commissioning and Hardware Installation Manual, 01/2015

  • Siemens SIMOTION P320-4 E, 5.5.4 IsoPROFIBUS board and PROFIBUS DP PROFIBUS DP connection example Both interfaces of the IsoPROFIBUS board can be used as PROFIBUS DP interfaces. The following screen shows an example of a PROFIBUS application. 6,1$0,&66 ZLWK&8'3 ERRNVL]H (WKHUQHW 3*3& ,VR352),%86 6,1$0,&66 ZLWK&8'3 ERRNVL]H 6,1$0,&66 ZLWK&8'3 ERRNVL]H 6,1$0,&66 ZLWK&8'3 ERRNVL]H 6,0$7,&b(7b0 6,0$7,&b(7b�

  • Siemens SIMOTION P320-4 E, Procedure To connect the IsoPROFIBUS board, proceed as follows: 1. Unlock the cover by pushing the latches in the direction of the arrow; swivel the released cover in the direction of the arrow and remove it. The interfaces for the optional IsoPROFIBUS board are then free.  2. Connect the IsoPROFIBUS board to the slots shown. Connection 5.5 Connecting PROFIBUS SIMOTION P320-4 E / P320-4 S 54 Commissioning and Hardware Installation Manual, 01/2015

  • Siemens SIMOTION P320-4 E, Case 2: SRAM not saved If the hardware of the SIMOTION P320-4 was operated outside of the defined specifications, the user data might not have been backed up in the SRAM of the SIMOTION P320-4 under certain circumstances. Service and maintenance 10.4 Special power-up situations SIMOTION P320-4 E / P320-4 S 126 Commissioning and Hardware Installation Manual, 01/2015

  • Siemens SIMOTION P320-4 E, Description 2 2.1 System overview Overview SIMOTION P is a PC-based, open Motion Control System from SIMOTION. Control, motion control, and HMI functions are executed together with standard PC applications on the SIMOTION P hardware platform. SIMOTION P combines the compatibility of the Windows operating system with real-time capability of SIMOTION P Runtime. The fully independent SIMOTION P Runtime runs in parallel to Windows on SIMOTION P. This real-time expansion makes it possible to implement demanding motion control applications with high performance requi

  • Siemens SIMOTION P320-4 E, To be noted before you replace the battery NOTICE Risk of damage! The lithium battery may only be replaced with an identical battery or with a type recommended by the manufacturer (article number: A5E30314053) WARNING Risk of explosion and release of harmful substances! Therefore, do not throw lithium batteries into an open fire, do not solder or open the cell body, do not short-circuit or reverse the polarity, do not heat to above 100 °C, dispose of them in accordance with regulations, and protect them fro

  • Operator Control (hardware) 7 7.1 SIMOTION P state application 7.1.1 SIMOTION P State application overview The LED, mode selector switch, and CF card handling indicators, which are implemented as hardware on other SIMOTION platforms, are visualized on the screen for SIMOTION P320-4. The display is done via the application SIMOTION P State. The following im

  • Siemens SIMOTION P320-4 E, Note LEDs for IsoPROFIBUS board The LEDs BUS1F and BUS2F are only shown if an IsoPROFIBUS board is connected. Additional references/information You can find additional information at: ● Diagnostics via LED displays (Page 127) (for a more accurate diagnosis of an LED status) ● Operating displays (SIMOTION P320-4 E / P320-4 S Manual: Information on display modes, of the SF PROFINET LEDs only displayed on the hardware side, in the operating displays section) ● PROFINET bus error occurs (Page 132) 7.1.3 Mode selector Mode selector in SIMOTION P state Use the mode selector to set the SIMOTION P320-4

  • Siemens SIMOTION P320-4 E, Options Menu Options Description Reset to factory default Restore the factory default. This will delete the following data: ● Non-volatile SIMOTION data (retain data) in the SIMOTION device ● The backup copy of non-volatile SIMOTION data on the external CFast card (PMEMORY.XML/PMEMORY.BAK) ● User data in the area "volatile SIMOTION data" (RAM) and on the external CFast card (ROM) ● The communication configuration (IP and DP parameters) on the external CFast card is set to the factory settings. The licenses on the CFast card are retained. Note Station Configurator settings Settings made wi

  • Siemens SIMOTION P320-4 E, &XUUHQWGDWD .HUQHOGDWD 5HWDLQGDWD 2 SHUDWLQJV\VWHP 6,027,21b3 )LUPZDUH 6,027,21b3 6WRUDJHPHGLD 6WRUDJHPHGLXP LQWHUQDO 66' &)DVWFDUG &)DVWFDUG 6WRUDJHPHGLXP H[WHUQDO %DFNXSV 8VHUGDWD 6,027,213 65$0 5$0 Figure 9-8 SRAM restore at startup Further information can be found in the section Non-volatile data and SRAM handling (Page 123). 9.8.4.3 Backing up non-volatile SIMOTION data (retain data) The non-volatile SIMOTION data (retain data) can be saved from the user program and from the SIMOTION SCOUT. You can use the backup to restore the

  • Siemens SIMOTION P320-4 E, You can now use this image to reset the SIMOTION P320-4 to the factory settings. Note that the changes made on the SIMOTION P320-4 will be lost in the process. NOTICE Retain data Once the image has been loaded, the user may have to delete the retain data. Procedure Use the Restart (Del. SRAM) function from the SIMOTION P State application to reset. Further information Function elements (SIMOTION P State) (Page 69) 10.3 Installing/removing SIMOTION P320-4 components 10.3.1 Preventive maintenance To maintain high system availability, we recommend the preventative exchange of those PC components that are subject t

  • Siemens SIMOTION P320-4 E, 5HWDLQGDWD .HUQHOGDWD &XUUHQWGDWD 8VHUGDWD %DFNXSV 6,027,21b3 )LUPZDUH 2 SHUDWLQJV\VWHP 6,027,21b3 6WRUDJHPHGLD 6WRUDJHPHGLXP LQWHUQDO 6WRUDJHPHGLXP H[WHUQDO &)DVWFDUG 66' &)DVWFDUG 65$0 5$0 6,027,213 Figure 9-16 Load project after Restart (Del. SRAM) Further information on the SIMOTION P State buttons can be found in the Function elements (Page 69) section. 9.9 SIMOTION P overall reset 9.9.1 SIMOTION P overall reset overview Introduction When an overall reset is performed, the RAM on the SIMOTION P320-4 will be cleared along with any non-volatile data in the SRAM - wit

  • 2.3.5 HMI or ES via IsoPROFIBUS (optional) Networking via PROFIBUS DP If you connect a central HMI via PROFIBUS DP, the X101 and X102 interfaces of the IsoPROFIBUS board are available. +0,(6 352),%86'3 ,2 'ULYHV 352),%86'3 ,2 'ULYHV 352),%86'3 6,027,213 6,027,213 ; ;�

  • Siemens SIMOTION P320-4 E, Protective conductor connection SIMOTION P320-4, 61 R Radiation High frequency radiation, 16 SIMOTION P320-4, 16 RAMtoROM, 111 Recommended order Initial commissioning, 94 References, 3 Replacing the battery SIMOTION P320-4, 121 Reset Delivery status, 116 Reset to factory default, 108 SIMOTION P State, 71 Restart SIMOTION P State, 69 Restart (Del. SRAM), 69 Delete SRAM, 109 Restart after Setup, 63 Restore DVD SIMOTION P320-4, 96 Restoring the default settings SIMOTION P320-4, 108 Retain data, 99 Backing up, 105 force backup, 109 Overal

  • Siemens SIMOTION P320-4 E, NOTICE During operation The external CFast card must not be removed during ongoing operation. Procedure Installation NOTICE Inserting a CFast card If you insert a CFast card into a built-in SIMOTION P320-4 in a system, observe the safety regulations for working with electrical systems. Insert the CFast card into the slot, working carefully and without applying excess force. Mounting 4.4 Installing and removing CFast cards SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual, 01/2015 37

  • Siemens SIMOTION P320-4 E, Ethernet interface for Windows The IP address of the Ethernet interface for Windows can only be modified via the Windows Control Panel > Network and Sharing Center. Figure 8-9 Windows Control Panel-Network and Sharing Center Note Windows Firewall To allows the Windows IP to be accessed externally, this must be set as an exception in the Windows Firewall File and Printer Sharing. Otherwise, there is only limited access to Windows from outside. Parameter assignment/addressing 8.5 Ethernet communication SIMOTION P3

  • Siemens SIMOTION P320-4 E, Procedure Proceed as follows to restore the delivery status of SIMOTION P320-4: 1. First, terminate SIMOTION P320-4 via the Terminate SIMOTION P button of the SIMOTION P State application. 2. Then select Extras > Reset to factory default in the menu. Figure 10-1 Restoring the delivery status NOTICE Note the consequences of user changes! All data and settings for SIMOTION P320-4 changed by the user will be deleted! The settings made using the Component Configurator will also be reset to the delivery condition. 10.2.3 Reset SIMOTION P320-4 to the initial state If an error occurred during parameter assignment, dow

  • Siemens SIMOTION P320-4 E, 5.2 Overview of connections Below the SIMOTION P320-4 interfaces to which the I/O devices can be connected are shown. 7)7PRQLWRU 7)7PRQLWRU '9,9*$ ; 'LVSOD\SRUW DOWHUQDWLYH DOWHUQDWLYH 352),1(7GULYHV HJ6,1$0,&66 352),1(7b,2 HJ(763 +0,3*(6 352),1(7 352),1(7 352),1(7 2QERDUG (WKHUQHW +0,3*(6 (WKHUQHW .H\ERDUGDQG 0RXVH 86% ; 352),%86'3 352),1(7GULYHV H J6,1$0,&66 352),1(7b,2 HJ(763 +0,3*(6 352),1(7RQERDUGFRQWUR

Related Products and Documents (Industrial PC):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 ZipRip UC5E Installation manual ziprip/uc5e-PZ1.pdf 08 Nov 2023 64
2 Boss Audio Systems AVA-1204 Operation & user’s manual boss-audio-systems/ava-1204-W31.pdf 04 Sep 2022 5 0.71 Mb
3 LightSpeed Technologies FP 100 Operation & user’s manual lightspeed-technologies/fp-100-XHA.pdf 11 Jul 2022 38
4 Xerox FREEFLOW 701P25032 System manual xerox/freeflow-701p25032-IE3.pdf 12 Oct 2022 112 0.64 Mb
5 Ashly WR-2 Installation ashly/wr-2-L5Y.pdf 28 Jan 2023 2 0.14 Mb
6 Opticon H-16 Operation & user’s manual opticon/h-16-82A.pdf 26 Apr 2023 79

Similar Resources:

  • GIGAIPC

    QBiX-Pro Series

    (46 pages)
    System - QBiX-Pro Series QBiX-Pro-GLKA5005HD-A1 (QP-5005A-SI)1www.gigaipc.com QBiX-Pro-GLKA5005HD-A1(QP-5005A-SI) Industrial Embedded SystemQuick Start Guide …
  • Kontron

    microETXexpress-OH

    (54 pages)
    If it’s embedded, it’s Kontron. microETXexpress®-OH Computer-on-Module (COM)Version 0.65 …
  • GIGAIPC

    QBiX-Pro-WHLA8565H-A2

    (46 pages)
    System - QBiX-Pro Series QBiX-Pro-WHLA8565H/8145H-A2 1www.gigaipc.comQBiX-Pro-WHLA8565H-A2 (QP-8565A-SI) QBiX-Pro-WHLA8145H-A2 (QP-8145A-SI) QBiX-Pro Industrial Embedded SystemQuick Start Guide …
  • Siemens

    SIMATIC IPC647D

    (220 pages)
    SIMATIC IPC647D ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ ___________________ SIMATIC Industrial PC SIMATIC IPC647D Operating Instructions 01/2014 A5E32996306-AA Preface Overview 1 Safety Instruction …
  • Siemens

    SIMATIC Box PC 620

    (206 pages)
    Preface, Table of ContentsProduct Overview1Commissioning the SIMATIC BoxPC 6202Welcome to the SIMATIC Box PC 6203Setting-up and Operatingthe SIMATIC Box PC 6204SIMATIC Box PC 620 Expansions5Configuring the SIMATIC Box PC 6206Error Diagnosis7Hardware Information8AppendixGuidelines for ESDAGlossary, IndexEdition 08/2001C79000-G7076-C639-04SIMATIC Box PC 620Man …
  • B&R

    Automation PC 510

    (194 pages)
    1Automation PC 510User's ManualVersion: 1.01 (June 2012)Orderno.: MAAPC510-GERAllinformationcontainedinthismanualiscurrentasofitscreation/publication.Wereservetherighttochangethecontentsofthismanualwithoutwarning.Theinformationcontainedhereinisbelievedtobe …

Comments, Questions and Opinions: