Manualios.com

Siemens SIMATIC 505 Operation & User’s Manual

Siemens SIMATIC 505 Manual Online:

3.9, 1612 votes
Siemens SIMATIC 505 User Manual
Siemens SIMATIC 505 User Guide
Siemens SIMATIC 505 Online Manual

Text of Siemens SIMATIC 505 User Guide:

  • Siemens SIMATIC 505, Preface vii SIMATIC 505 Interrupt Input Module User Manual Preface This manual provides the information needed to install, wire, and configure the following SIMA TIC 505 Isolated Interrupt Discrete Input Modules: PPX:505–4317 24 VDC PPX:505–4318 48 VDC PPX:505–4319 125 VDC Except for their input voltage differences, these modules function identically. Refer to the manuals listed below for instructions on installing, programming, and troubleshooting your controller and I/O. The x

  • Siemens SIMATIC 505, MANUAL PUBLICA TION HISTOR Y SIMATIC 505 Isolated Interrupt Discr ete Input Modules User Manual Or der Manual Number: PPX:505-8123-2 Refer to this history in all correspondence and/or discussion about this manual. Event Date Description Original Issue 03/93 Original Issue (2801386–0001) Second Edition 04/95 Second Edition (2801386–0002)

  • Siemens SIMATIC 505, Installing the Module 2-2 SIMATIC 505 Interrupt Input Module User Manual 2.1 Overview of Installation Figure 2-1 shows the organization of the tasks described in this chapter . Insert module into base Power up Set I/O configuration with TISOFT programming device W rite I/O configuration to controller memory Configure operating mode dipswitches Wire and connect input terminal block Figure 2-1 Flowchart of Installation Flow of T asks

  • Installing the Module 2-14 SIMATIC 505 Interrupt Input Module User Manual 2.5 Configuring I/O Memory in the CPU After the module has been inserted into the I/O base, you must register the I/O addresses for each module in the CPU memory . (The module does not automatically register addresses in the CPU when it is inserted.) This is important because even though the module

  • Siemens SIMATIC 505, Operating the Module 3-1 SIMATIC 505 Interrupt Input Module User Manual Chapter 3 Operating the Module 3.1 Operational Description 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Module in Non-Interrupt Mode 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Module in Interrupt Mode 3-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Writing an Interrupt RLL Pr ogram 3-3. . . . . . . . . . . . . . . . . . . . . . . . .

  • Siemens SIMATIC 505, Contents v List of Figures Figur e 1-1 DC Interrupt Input Module 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figur e 2-1 Flowchart of Installation 2-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figur e 2-2 Location of Interrupt Dipswitch Gr oup 2-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figur e 2-3 S1 Dipswitch Settings 2-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figur e 2-4 S2 Dipswitch Se

  • Siemens SIMATIC 505, Installing the Module 2-7 SIMATIC 505 Interrupt Input Module User Manual 2.3 Inserting the Module into the Base ! WARNING Failure to follow appropriate safety precautions could result in death or serious injury and/or damage to equipment. T o minimize risk of potential shock hazard, turn off power to the I/O base and to any modules installed in the base before inserting or removing a module or installing a terminal block. The power must be turned off to the I/O base and to any modules installed in the base before inserting or removing a module or installing a terminal block. The Interrupt

  • Siemens SIMATIC 505, Operating the Module 3-4 SIMATIC 505 Interrupt Input Module User Manual 3.2 Module Status and Troubleshooting An LED array showing input and interrupt enable status is located on the front of the module. (See Figure 3-1.)          LED Elements on Interrupt Input Module Display Function A1 – A4 status of points 1–4 . . . B1 – B4 status of points 5–8 . . . C1 – C4 status of points 9–12 . . . D1 – D4 status of points 13–16 . . . A5 – A8 not used . . . B5 – B8 not used . . . C5 – C8 interrupt enable status of points 9–12 . . . D5 – D8 interrupt enable status of points 13–16 . . . Interrupt Enable Statu

  • Siemens SIMATIC 505, Operating the Module 3-5 SIMATIC 505 Interrupt Input Module User Manual The LED Input Status Indicators and the CPU indicate whether the module is operating correctly . T able 3-2 shows symptoms, probable causes and corrective actions to take if the module is not operating correctly . T able 3-2 Tr oubleshooting Chart Symptom Probable Cause Corrective Action Not receiving power Check power supply and connections. LED is not lit User program problem Check user program or I/O configuration. LED is not lit Wrong terminal block connections Trace wiring connections. Faulty LED Return module for repair. Wrong terminal block connections Trace wiring connections. Incorrect values Noise o

  • Siemens SIMATIC 505, BUSINESS REPL Y MAIL FIRST CLASS PERMIT NO.3 JOHNSON CITY , TN FOLD FOLD POST AGE WILL BE P AID BY ADDRESSEE NO POST AGE NECESSARY IF MAILED IN THE UNITED ST ATES ATTN: Technical Communications M/S 519 SIEMENS INDUSTRIAL AUTOMATION INC. 3000 BILL GARLAND RD P O BOX 1255 JOHNSON CITY TN 37605–1255

  • Siemens SIMATIC 505, Installing the Module 2-11 SIMATIC 505 Interrupt Input Module User Manual You can use either of the terminal blocks shown in Figure 2-10. Both terminal blocks are removable. T o wire the terminal block, follow the procedure below . 1. T urn the terminal block, with the screw-heads facing you, until the A-series of terminals is at the top and the D series is at the bottom. 2. Using Figure 2-7 as a wiring guide, start with the D’s and loosen the appropriate terminal block screws. 3. Strip back the insulation on the wires about 1/4 to 3/8 inch or one centimeter . Use a 12–26 A WG or a 0.16–3.2 mm 2

  • Contents iii Contents Preface Chapter 1 Product Overview 1.1 Description of Basic Featur es 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Featur es 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compatibility

  • Siemens SIMATIC 505, Installing the Module 2-10 SIMATIC 505 Interrupt Input Module User Manual Field Wiring (continued) The Interrupt Input Modules inputs are floating. Therefore, the inputs will operate when wired in either a sinking or sourcing configuration, as shown in Figure 2-8. +– Input – Input + Field Side Module Side +– Input – Input + Input + Input – +– Input – Input + +– Input – Input + Input – Input + Sourcing Configuration (Isolated) Sourcing Configuration Sinking Configuration (Isolated) Sinki

  • Siemens SIMATIC 505, Product Overview 1-1 SIMATIC 505 Interrupt Input Module User Manual Chapter 1 Product Overview 1.1 Description of Basic Featur es 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Featur es 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compatibility with SIMA TIC CPUs 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Sour ces 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Siemens SIMATIC 505, iv Contents Appendix A Specifications A.1 Specifications A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.2 Terminal Block W orksheet A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Siemens SIMATIC 505, Specifications A-1 SIMATIC 505 Interrupt Input Module User Manual Appendix A Specifications A.1 Specifications A-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A.2 Terminal Block W orksheet A-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Installing the Module 2-13 SIMATIC 505 Interrupt Input Module User Manual 1cm (0.39 in.) Wire Gauge: 12–26 Max. Width: 5.54 mm (0.218 in.) Stud Size: #4 (2.5mm) Amp Part#: 321462 Max. Width: 4.62 mm (0.182 in.) Stud Size: #4 (2.5mm) Amp Part#: 327891 P/N 2587705–801 1 Front-accessible 1cm (0.39 in.) Wire Gauge: 12–26 Connector –8010 accepts any of the three wire termin

  • Siemens SIMATIC 505, SIMATIC is a registered trademark of Siemens AG. Series 505 and TISOFT are trademarks of Siemens Industrial Automation, Inc. Underwriters Laboratories is a registered trademark of Underwriters Laboratories.

  • Siemens SIMATIC 505, Product Overview 1-3 SIMATIC 505 Interrupt Input Module User Manual The Interrupt Input Modules have two groups of dipswitches located at the top of the board, as shown in Figure 1-1. The module includes a standard input terminal connector which can be detached from the module without having to remove the module from the base. An LED array on the faceplate shows input status for each point and also interrupt enable mode. Chapter 2 describes how to configure the dipswitches, wire the terminal block, and install the module. Chapter 3 describes the basic operating features and the use of the LED array for reading the status of the inputs. Switch S1 Interrupt T ype

  • Siemens SIMATIC 505, Customer Response We would like to know what you think about our user manuals so that we can serve you better. How would you rate the quality of our manuals? Excellent Good Fair Poor Accuracy Organization Clarity Completeness Graphics Examples Overall design Size Index Would you be interested in giving us more detailed comments about our manuals? Yes! Please send me a questionnaire. No. Thanks anyway. Your Name: Title: Telephone Number: ( ) Company Name: Company Address: Manual Name: SIMA TIC 505 Isolated Interrupt Discrete Input Module Edition: Second Manual Assembly Number: 2586546–0085 Date: 04/95 Order Number: PPX:505–8123–2

  • Siemens SIMATIC 505, Installing the Module 2-3 SIMATIC 505 Interrupt Input Module User Manual Many integrated circuit (IC) devices are susceptible to damage by the discharge of static electricity . Follow the suggestions listed below to reduce the probability of damage to these devices when you are handling a CPU, a base controller , or any of the I/O modules. Both the module and the person handling the module should be at the same ground potential. T o accomplish this, fulfill the following conditions. • T ransport the module in an anti-static container or antistatic material. • Ensure th

  • Siemens SIMATIC 505, Operating the Module 3-3 SIMATIC 505 Interrupt Input Module User Manual In order to take advantage of the Interrupt feature of this module, you must write a Relay Ladder Logic (RLL) program that contains the appropriate logic to execute the required response to interrupts generated by this module. For a more detailed description of the requirements and operation of the interrupt RLL program, refer to the SIMA TIC TI545/TI555 System Manual (PPX:545/555–8101–2) and the SIMA TIC TI505 Programming Reference Manual (PPX:505–8104–5). The Interr

  • Siemens SIMATIC 505, Installing the Module 2-6 SIMATIC 505 Interrupt Input Module User Manual Configuring the Module Operating Mode (continued) Figure 2-5 shows an example of a configuration that enables interrupt mode and the dipswitch setting used for the given configuration. • Points 9 and 10 are configured to be non-interrupting. • Points 1 1 and 12 are configured to generate an interrupt upon an on-to-off transition. • Points 13 and 14 are configured to generate an interrupt upon an off-to-on transition. • Points 15 and 16 are configured to generate an interrupt upon either transition. No Interru

  • Siemens SIMATIC 505, Installing the Module 2-8 SIMATIC 505 Interrupt Input Module User Manual 2.4 Field Wiring These modules do not require user-supplied power. A module consumes a maximum of 2.0 W of +5 V power from the base backplane. The modules have been designed to work with up to 1000 feet (303 meters) of wire to the switch. The size of the wire used must be adequate for switch current. T o prevent noise on the signal wiring, keep signal and power wiring separate. For input or output signals and class 2 power supply wires, use shielded, twisted-pair cable (12–26 A WG or 0.16�

Related Products and Documents (I/O Systems):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Jensen VM9223 - Touch Screen Double Din MultiMedia Receiver Installation manual jensen/vm9223-touch-screen-double-din-multimedia-receiver-94N.pdf 07 Dec 2022 12
2 Waterway OASIS Troubleshooting manual waterway/oasis-UJ2.pdf 28 Aug 2023 1
3 Toro 03681 Operator's manual toro/03681-C75.pdf 17 Nov 2023 20
4 Gemini MX-01 Operation manual gemini/mx-01-3KQ.pdf 27 Aug 2022 8
5 Lenovo GCM16 Quick installation manual lenovo/gcm16-5Z2.pdf 25 Jun 2023 4
6 Porter-Cable JOB BOSS C3550 Instruction manual porter-cable/job-boss-c3550-KAB.pdf 09 Sep 2022 26

Similar Resources:

  • Contec

    ADI16-4(FIT)GY

    (3 pages)
    Ver.1.10 ADI16-4(FIT)GY 1 F&eIt Series Isolated High-Resolution Analog Input Module ADI16-4(FIT)GY * Specifications, color and design of the products are subject to change without notice. Congratulations on your recent purchase of an Isolated Analog Input Module. The ADI16-4(FIT)GY can be connected to the F&eIT series of controller m …
  • National Instruments

    FP-PWM-520

    (10 pages)
    FieldPoint ™ is a trademark of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies.322139B-01 © Copyright 1998, 1999 National Instruments Corp. All rights reserved. June 1999OPERATING INSTRUCTIONSFP-PWM-5208-Channel, 5 or 24 V PWM Output ModuleThese operating instructions …
  • National Instruments

    6738

    (16 pages)
    CALIBRATION PROCEDURENI 6738/6739Analog Output Devices and Modules with NI-DAQmxThis document contains the verification and adjustment procedures for the National Instruments PCIe-6738 and PXIe-6738/6739 analog output devices and modules. For more information about calibration solutions, visit ni.com/calibration.ContentsSoftware.............................. …
  • Texmate

    Tiger 320 Series

    (44 pages)
    Mar-14-2016 DI-60 320 DS (NZ301)_UL_March 2016 Page 1Texmate, Inc. Tel. (760) 598-9899 • www.texmate.comA powerful, intelligent, 6-digit Programmable Meter Controller (PMC)with modular outputs, input signal conditioning and advanced softwarefeatures for monitoring, measurement, control and communication applications.DI-60E & DI-60TProgrammable Meter …
  • National Instruments

    NI 9251

    (8 pages)
    CALIBRATION PROCEDURENI 9251 with mini XLR2 AI, 3 Vrms, 24 Bit, 102.4 kS/s/ch Simultaneous, AC/DC CouplingThis document contains the verification and adjustment procedures for NI 9251 withmini XLR. For more information about calibration solutions, visit ni.com/calibration.ContentsSoftware....................................................................... …
  • ICP DAS USA

    WF-2060

    (8 pages)
    WF-2060 Quick Start RevB1.0 2016/10 1/8 Quick Start 「 WF-2060」Package Checklist The package includes the following items:  One WF-2060 module  One Quick Start  One software utility CD  One screw driver  One RS-232 cable (CA-0910)  One Antenna 2.4GHz - 5 dBi (ANT-124-05) Note: 1. If any of these items are missed or da …

Comments, Questions and Opinions: