SEFRAM DAS60 Operation & User’s Manual

SEFRAM DAS60 Manual Online:

3.6, 856 votes
SEFRAM DAS60 User Manual
SEFRAM DAS60 User Guide
SEFRAM DAS60 Online Manual

Text of SEFRAM DAS60 User Guide:

  • Set-up and Precautions of Use Page 4.2 4.2. Setup You turn on the recorder by pressing the button at the top of the device. When the device is on, the ON/OFF button is lit blue. After launching the software, the recorder displays a homepage that specifies the hardware version, then switches automatically to the « Direct display » mode (oscilloscope). You can dis

  • SEFRAM DAS60, Ethernet Interface Page 15.24 15.8.13. Diagrams GRID P1,P2 Set-up of the diagrams P1 = Number of the diagram GRID ? Returns the set-up of all diagrams GRID:LOG P1,P2,P3 Set-up of the diagrams for logic channels P1 = Number of logic channels P2 = Heigth of the logic channels P3 = UP or DOWN : position of the logic channels GRID:LOG ? Returns the set-up of all diagrams GRID:LENGth P1,P2,P3 GRID:LENG 1,0,100 Set-up of each diagram P1 = number of the diagram P2 = min value (0 to max); max = 250 or 200 according to the app

  • SEFRAM DAS60, Triggers Page 6.1 6. TRIGGERS This chapter describes all possible triggers of the device. They are used by: - the « configuration » menu, with the A and B alarms - the « triggers » menu, with the start and stop parameters of the recording.  Edge/Level trigger  Edge trigger: you need a change of status o Example: Channel A1, rising edge, threshold = 0V: triggers only if the signal status changes from negative to positive  Level trigger: no need to pass the threshold o Example: Ch

  • SEFRAM DAS60, Use Page 5.4 5.3.1. Analog channels 1- Number of the channel 2- Name of the channel: give a name to the channel (max. 26 characters) 3- Type: selection of the type of measurement made on the input  voltage, current, frequency, thermocouple or counter  direct, RMS, ΔV/Δt or ʃV.dt  value of the shunt for current measure (sensor 4-20mA automatic)  selection of the type in thermocouple, compensation, unit 4- Type of external sensor 5- Filter: positioning of a filter on the input  10kHz, 1kHz, 100Hz, 10Hz for analog filters  1Hz, 10s, 100s or 1000s for t

  • SEFRAM DAS60, Inputs / Outputs Page 14.3 14.2. Logic inputs Non-connected inputs are according to the following circuit: Non-connected inputs are 0V potential (level 0). Number of logic channels: from 1 to 16. TTL level: 3.3V (protected up to 24V) To create a rising edge, you only have to place a connection between the power input and output of the connector. Similarly, to create a falling edge, you only have to remove this connection. You can also use an output signal TTL 3.3V. 14.2.1. Use Plotting and display: These channels are

  • SEFRAM DAS60, File Management Page 13.9 You can also directly create a result file (text or Excel file) by launching the following line in the Windows ® command mode: (see Menu, sub-menu Help Options) Example: C:\SeframViewer monfichier.rec /x : direct creation of an Excel file C:\SeframViewer monfichier.rec /t : direct creation of a text file. Excel® export directly launches Excel in the explorer. 13.3.3. Managing with SeframPilot You can manage the recorder directly from SeframPilot. This software allows you to:  Manage setups (creation and c

  • SEFRAM DAS60, Ethernet Interface Page 15.3 For example, in I mode, you could have: PC IP=192 135.20.00 mask = 255.255.255.0 Recorder IP=192.135.20.01 mask = 255.255.255.0 Refer to the definition of the classes of IP addresses. Programmation: You can create your own software under Visual Basic, Visual C++, etc. by using, for example, the Winsock.dll driver by Microsoft. Then, you only have to send the commands as per the following paragraphs to the recorder. 15.2. WIFI interface Use only the

  • SEFRAM DAS60, Network Analysis Page 12.6  Selection of the channels: you select either all the voltage channels (U1, U2, U3) or all current channels (I1, I2, I3) or all network channels (U1, U2, U3 + I1, I2, I3) or only one channel (these channels are also used to record harmonics.  Sampling frequency: 200µs  Number of points: 2048  A cursor allows you to display the value of the selected harmonic  Parameters: display of the values of each parameter. At any moment, you can copy the screen into a bitmap file (on a hard disk or a USB stick) by pressing . 12.4. Power analysis setup Once the device is set up, you still have to se

  • Presentation Page 3.8 Note: By pressing various parameters, you can change them. In addition, by pressing the name of the channel (A1, A2…), you directly access the parameter setting page of the channel 16- Configuration of the function channels (calculations between several channels) 17- Activation or deactivation menu of the various channels.

  • SEFRAM DAS60, Ethernet Interface Page 15.22 15.8.9. Memory mode HEADER PARAMETERS EXAMPLES MEMSpeed P1,P2 MEMSpeed 10,MICro Set-up of the sampling period 10 µsec period P1 = Period (from 1 to 500) P2 = MICro,MILIsec,Sec,MIn,HOurs is the unit MEMSpeed:EXT Use of an external clock MEMSpeed ? Returns the data acquisition speed MEMBloc P1 MEMBLOC 4 Set-up of the number of blocks 4 blocks P1 = 1,2,4,8,16...128 MEMBloc ? Returns the number of blocks and the validation of each block :MEMBLOC 4,2 : 4 blocks, incl. 2 valid ones POSTrig P1,P2 :STOP:AUTO;POSTRIG 0 Set-up of the triggering position in the data acquisition Acquisition aft

  • SEFRAM DAS60, Set-up and Precautions of Use Page 4.4 4.3.5. Connection of the ground  If the source of the signal you have to record has low internal impedance, you shall use twisted wires. In case of high impedance, you shall use shielded wires.  When gathering grounds from the various items on the measurement line, it is good to check that there is no voltage difference between them, in order to prevent any shortcut. If any doubt, make a measurement with a voltmeter on a low resistance (i.e. 1kΩ) between the terminals. 4.4. Routine ma

  • SEFRAM DAS60, Important Information 15. ETHERNET INTERFACE .................................................................................................. 15.2 15.1. Ethernet Interface .......................................................................................................... 15.2 15.1.1. General ................................................................................................................... 15.2 15.2. WIFI interface .........................................................................................................

  • SEFRAM DAS60, Set-up and Precautions of Use Page 4.6 4.7. Default calibration You can restore the default factory calibration to correct any possible mistake in the calibration coefficients: Go to page « Electric calibration » (see the previous section) Press and validate to restore the default factory calibration coefficients and give the date of initial plant start. 4.8. Screen brightness You can settle the screen brightness. You can access this parameter at page then and then . 4.9. Locking of the recorder You can lo

  • SEFRAM DAS60, Inputs / Outputs Page 14.5 14.5. Exvoltage box input/output interface The exvoltage box input/output interface option (code 984405500) makes it possible to:  Convert an alternating voltage (example 230V 50Hz) into a logic signal 1  Easy connection of the inputs of the 16 logic channels  Insulation of the 16 logic inputs (250V=~ between channels, 250V=~ between channels and ground)  Easy connection of the alarm outputs by a screw terminal  Power supply of an external accessory

  • SEFRAM DAS60, Technical Specifications Page 16.2 16.1.3. RMS recording Software RMS calculation: sampling: 200µs max. frequency: 500Hz peak factor : 2.2 and 600V max. instant accuracy: ± 1% (sine signal) answering time: typical 100ms (40ms @ 50Hz) max. measurable voltage: 424 V AC 16.1.4. Temperature recording Sensor Domain of use J -210°C to 1200°C K -250°C to 1370°C T -200°C to 400°C S -50°C to 1760°C B 200°C to 1820°C E -250°C to 1000°C N -250°C to 1300°C C 0°C to 2320°C L -200°C to 900°C The accuracy o

  • SEFRAM DAS60, File Management Page 13.3 It is highly advisable to work in a directory and not at the root of the flash disk When erasing a directory, all files in this directory will be erased too. 13.2. Management of the configuration files The configuration file management page is linked to the key. There name bear the "cnf" exvoltage. 1- Reset: sets up the device in standard configuration 2- Load from disk: loads a configuration from a file in the internal flash disk or an USB stick 3- Save to disk: saves a confi

  • Use Page 5.12 7- Access to the channel configuration page: 1- Screen setup: configuration of display of measurements on screen  Selection of the graphic display mode:  F(t)  XY  Digital measures (full screen)  Full screen to display the reticule on the whole screen (mode f(t))  Colors to customize the display (background, reticule

  • SEFRAM DAS60, Use Page 5.15 5.6. « Trigger » menu Programming the start and stop conditions for the paper print in Direct mode, and the data acquisition conditions for the channels in Memory, File and Template modes. Selection of the actions after data acquisition or plot and validation of the save in real time. The program of triggers is different according to the pending mode (Direct, Memory, File or Template). See the chapter of the pending mode for more details.

  • Triggers Page 6.4 6.1.3. Parasites You can trigger a parasite with a periodic 50Hz signal: trigger when the shape of the signal radically changes:  parasite impulsion >200µs  sudden change of frequency  sudden change of shape

  • SEFRAM DAS60, Use Page 5.10 5.4. Validation of the channels You can validate or not the channels to record or print out in the various configuration menus of the recorder. In order to validate or not the record or the printing of a channel, you must check (to validate) or uncheck (not to validate) the checkbox right to the bargraph of the channel.

  • SEFRAM DAS60, Technical Specifications Page 16.1 16. TECHNICAL SPECIFICATIONS 16.1. Isolated inputs 16.1.1. General characteristics Number of inputs: 6 according to the device Impedance: Impedance > 25 MΩ for calibers < 1V Impedance = 1 MΩ for the other calibers Max. acceptable voltages: between the 2 terminals of a channel: +500 V DC or 500 V AC 50Hz Installation category: overvoltage category: III 600V Insulation: double insulation between the mechanical ground and the measurement channel: >100 MΩ @ 500V DC. Common mode parasites: test according to EN 61143 Accessible current < 0.75mA Type of measurements: Voltage, intensity (through extern

More Instructions:

DOWNLOAD

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 TRENDnet TEG-S224TXA - 26PORT Gigabit Copper Switch 24-10/100 2-10/100/1000 Operation & user’s manual trendnet/teg-s224txa-26port-gigabit-copper-switch-24-10-100-2-10-100-1000-H6U.pdf 22 Jan 2023 41 0.24 Mb
2 Star Omelet Maker Dimensions and specifications star/omelet-maker-BK2.pdf 11 Sep 2022 2 0.81 Mb
3 Kenmore 790. 4045 Use & care manual kenmore/790-4045-Z9S.pdf 29 Jul 2022 44
4 Daikin FTX50GV1B Operation manual daikin/ftx50gv1b-48B.pdf 25 Jul 2023 30 2.69 Mb
5 Hyundai TUSCON Owner's manual hyundai/tuscon-756.pdf 10 Mar 2023 305
6 Emerson Bristol Helicoid Gauges Product overview emerson/bristol-helicoid-gauges-GT9.pdf 21 Dec 2022 1 0.24 Mb

Similar Resources:

  • Olympus

    DM-650

    (3 pages)
    Specifications and appearances are subject to change without any notice or obligation on the part of the manufacturerDM-650• Low-Cut Filter, NoiseCancel and Voice Filterfor crystal clear audioprocessing• Linear PCM (48kHz/16bit= better than CD quality),MP3 and WMA• 3 high-quality microphonesfor true, wideband stereorecording• 4GB internal memory plus …
  • Sony

    XDS1000

    (116 pages)
    PROFESSIONAL MEDIA STATIONXDS-10004270117020OPERATION MANUAL [English]1st Edition (Revised 1)The supplied CD-ROM includes operation manuals for the XDS-1000 Professional Media Station (English, Japanese, French, German, Italian, Spanish and Chinese versions) in PDF format.For more details, see “Using the CD-ROM Manual” on page 14. …
  • Tascam

    Mixcast 4

    (124 pages)
    D01382200CPodcast Recording ConsoleOWNER’S MANUALMODE D’EMPLOIMANUAL DEL USUARIOBEDIENUNGSANLEITUNGMANUALE DI ISTRUZIONI取扱説明書Please see the Reference Manual for information about all the unit’s functions. You can download the Reference Manual from the TASCAM website.Veuillez consulter le manuel de référence pour des informations sur toutes …
  • Digital Audio Corporation

    SSABR G2

    (53 pages)
    Solid State Recorder Generation 2 User's Manual Software Revisions 1.1.0 DIGITAL AUDIO CORPORATION A DRI COMPANY "THE POWER TO HEAR – THE POWER TO CONVICT" …
  • Safa Media

    SR-M160N

    (38 pages)
    User's ManualMP3 VOICE RECORDERSR-M160N/M180N/M190N Thank you your purchasing a MP3 VOICE RECORDER.Please read this User Guide before you use MP3 VOICE RECORDER.There is a warranty inside of manual. Please state the content of warranty when you purchase it.Please keep the warranty.;.! )15F DongWon Securities B/D, Karak-Dong, Songpa-Ku, …
  • Attainment Company

    Big Button with Steps and Levels

    (2 pages)
    with Steps and LevelsAttainment Company’sBig ButtonHolds 3” x 3” images Weight: 8.1 oz. (.23 kg) Size: 57⁄8” across (14.6 cm)AAttainment Company, Inc.P.O. Box 930160 •Verona, WI 53593-0160 • USA Phone 1-800-327-4269 • I nter national 1-608-845-7880www.AttainmentCompany.comUser’s GuideTen levels— each with 8 seconds recording time.Th …

Comments, Questions and Opinions: