Text of ABB Endura AZ20 series User Guide:

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe IM/AZ20M–EN Rev. B 13 5 Dismantling and Reassembly – Probe 5.1 Before Removing / Replacing the Probe 5.2 Before Dismantling a Probe 5.3 Preparation The following equipment and working conditions are recommended to ensure the probe is maintained in a suitable environment:  a clean, dry, moisture- and dust-free atmosphere  a workbench of at least twice the probe length – for example, to maintain a 4.0 m (13.12 ft) probe, a workbench of at least 9.0 m (29.5 ft) is recommended  support along the com

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe 16 IM/AZ20M–EN Rev. B 5.7 Replacing the Diffuser Flame Arrestor and / or Cell Before replacing the cell: 1. Ensure a replacement cell kit is available – refer to Section 7.1, page 43. 2. Remove the probe from its mounting as detailed in Section 5.4, page 14 (integral probe) or Section 5.5, page 14 (remote probe). 3. Record the cell data printed on the existing cell label – refer to the probe User Guide (IM/AZ20P–EN) for label details. 4. Remove the probe end cap as detailed in Section 5.6.1, page 15. 5.7.1 Removing the Diffuser Flame Arrestor Referring to Fig. 5.4: 1. At the probe head,

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe 20 IM/AZ20M–EN Rev. B 5.8 Replacing the Thermocouple / Electrode Assembly Before replacing the thermocouple and electrode assembly: 1. Ensure replacement thermocouple and electrode assembly and C-ring kits are available – refer to Section 7.7, page 44. 2. Remove the probe from its mounting – refer to Section 5.4, page 14 (integral probe) or Section 5.5, page 14 (remote probe). 3. Remove the probe end cap as detailed in Section 5.6.1, page 15. 5.8.1 Removing the Thermocouple /

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 2Introduction IM/AZ20M–EN Rev. B 5 1.9 Safety Recommendations For safe operation, it is imperative that these service instructions be read before use and that the safety recommendations mentioned herein be scrupulously respected. If danger warnings are not heeded to, serious material or bodily injury could occur. 1.10 Service and Repairs Serviceable items are listed in Section 7, page 42 and Section 8, page 45. Maintenance and servicing of the instrument's components must be perform

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 4 Troubleshooting – Functional Checks 10 IM/AZ20M–EN Rev. B 4.3 Checking Cell Output Voltage In the following checks, test gas is applied to the probe and the cell output is measured to check if the cell is functioning to theoretical values in isolation from any associated transmitter. The check can be performed using 1 test gas (for a functional check) or 2 test gases (for a detailed cell accuracy check). Using 2 test gases provides the most accurate result – both checks refer to the graph in Fig. 4.3:

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe IM/AZ20M–EN Rev. B 21 Fig. 5.7 Removing the Thermocouple / Electrode Assembly PT 1000 G A E D F Red (Cell +) Green (TC +) White (TC –)

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 6 Dismantling and Reassembly – Transmitter 40 IM/AZ20M–EN Rev. B 6.3.3 Probe Cable Connections to Remote Transmitter Referring to Fig. 6.7: 1. Feed the probe cable through cable gland A and tighten the gland. 2. Make probe cable connections B at the probe as detailed in Appendix B, page 48. 3. Make probe cable connections at the transmitter terminal blocks C as shown in Table 6.1. 4. Proceed to Section 6.3.4, page 41 to make probe power and signal connections. Ter m in al Number Tag ID Connection Type Cable Color 1 H Heater Brown 2 H

  • ABB Endura AZ20 series, The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company’s produ

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 3 Troubleshooting – Quick Checks 8 IM/AZ20M–EN Rev. B 3.5 Checking the Cell Isolation Referring to Fig. 3.5: 1. At the 9-way terminal block A, check the resistance from the probe’s red (Cell +) connection B to the probe body C. 2. Check that the cell + connection is isolated from the probe body earth. If it is not isolated, check for short-circuits to earth in the probe’s internal wiring. 3. With the cell at ambient temperature, the measured resistance should be > 20 k. If the measured resistance

  • Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe IM/AZ20M–EN Rev. B 33 Referring to Fig. 5.18: 16. Fit test gas to sensor tube M and reference air tube ?N 17. Fit test gas 1 and 2 tubes ?O 18. Push the 2 terminal plugs P into the terminal blocks and locate / tighten the terminal plug M3 retaining screws ?Q 19. Refit the probe end cap. 20. If the ext

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 3 Troubleshooting – Quick Checks 6 IM/AZ20M–EN Rev. B 3 Troubleshooting – Quick Checks Troubleshooting diagnostics are displayed on the transmitter – refer to the transmitter User Guide (IM/AZ20E–EN). Where a diagnostic fault is traced to the probe, it may be possible to identify and rectify the fault. After any rectification, the system must be recalibrated. The following checks can be used to troubleshoot the cause of probe failure quickly:  checking heater resistance – refer to Section 3.3, page 7  checking thermocouple / electrode assembly resistance – refer to Section 3.4, page 7  checking cell

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 7 Illustrated Parts List – Probe 42 IM/AZ20M–EN Rev. B 7 Illustrated Parts List – Probe Item Description Kit Components Replacement Procedure 1 Cell assembly Table 7.1, page 43 Refer to Section 5.7, page 16 2 Diffuser flame arrestor Table 7.2, page 43 Refer to Section 5.7.4, page 18 3 C-ring Table 7.3, page 43 Refer to Section 5.7.3, page 18 4 AutoCal assembly AutoCal upgrade assembly (with NPT or BSP connector) AutoCal refurbishment kit Table 7.4, page 43 Table

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 6 Dismantling and Reassembly – Transmitter IM/AZ20M–EN Rev. B 39 6.3 Replacing the Remote Transmitter Backplane 6.3.1 Removing the Backplane 1. Remove the transmitter cover and cartridge as detailed in Section 6.1.1, page 36, steps 1 to 4. Referring to Fig. 6.5: 2. Disconnect the existing power and signal connections to terminal blocks A and insulate individual mains cable terminations as a safety precaution. 3. Unscrew and remove the 3 backplane retaining pillars / screws B using a 7 mm A/F socket. 4. Lift the backboard C out of the probe transmitter housing D and discard the backboard – refer to the transmitter User Guide (IM/AZ20

  • Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe 24 IM/AZ20M–EN Rev. B 5.9 Replacing the Heater Assembly Before replacing the heater assembly: 1. Ensure replacement heater and C-ring kits are available – refer to Section 7.6, page 44. 2. Remove the probe from its mounting as detailed in Section 5.4, page 14 (integral probe) or Section 5.5, page 14

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 1 Safety 4 IM/AZ20M–EN Rev. B 1.4 Product Recycling Information 1.5 Product Disposal 1.6 Restriction of Hazardous Substances (RoHS) 1.7 Safety Precautions Please read the entire manual before unpacking, setting up, or operating this instrument. Pay particular attention to all warning and caution statements. Failure to do so could result in serious injury to the operator or damage to the equipment. To ensure the protection provided by this equipment is

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 8 Illustrated Parts List – Transmitter IM/AZ20M–EN Rev. B 45 8 Illustrated Parts List – Transmitter 8.1 Cartridge 8.2 AZ20 Integral (Type 3) Probe Backplane 8.3 AZ20 Remote (Type 4) Probe Backplane Item Description Kit Components Replacement Procedure 1 Cartridge Table 8.1 Refer to Section 6.1, page 36 2 Integral (Type 3) probe backplane Table 8.2 Refer to Section 6.2, page 38 3 Remote (Type 4) probe backplane Table 8.3 Refer to Section 6.3, page 39 Fig. 8.1 AZ20 Trans

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe IM/AZ20M–EN Rev. B 31 5.10.2 Fitting an AutoCal Assembly Referring to Fig. 5.16: 1. Locate the AutoCal manifold A on the internal mounting plate with the pressure switches (PS1 and PS2) at the front of the plate (the same side as the 9-way terminal block). Secure the manifold using the 2 M3 screws B (supplied). 2. On remote probes, locate the 6-way AutoCal terminal block / plug C and secure it using the 2 M3 screws D (supplied). On integral probes, the termi

  • Combustion Oxygen Monitor Endura AZ20 Series Probe Appendix A – Connection Diagrams IM/AZ20M–EN Rev. B 47 A.2 AZ20 Remote Probe Fig. A.2 AZ20 Remote Probe – Connection Diagram Mains L Mains N Relay 1 NC Relay 1 Common Relay 2 NC Relay 2 Common L N E N/C N/C C C TB1 TB2 TB3 TB9 TB7 TB8 Cell + Cell  ACJC ACJC T/C+ T/C SCN AZ200 140 Cable 9 8 7 6 5 4

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 6 Dismantling and Reassembly – Transmitter IM/AZ20M–EN Rev. B 37 6.1.2 Replacing the Integral Transmitter Cartridge 1. Ensure a replacement cartridge of the correct type is available – refer to Section 8.1, page 45 for cartridge options. Referring to Fig. 6.2: 2. Screw security pin A in (clockwise) to enable the cover to be removed. 3. Unscrew the transmitter cover B by twisting it anti-clockwise. 4. Slacken the 3 cartridge retaining screws C, lift the cartridge D away from the housing and d

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe 5 Dismantling and Reassembly – Probe 34 IM/AZ20M–EN Rev. B 5.11 Replacing / Fitting Restrictors Before proceeding:  Ensure a restrictor kit is available – refer to Section 7.8, page 44.  Remove the probe from its mounting as detailed in Section 5.4, page 14 (integral probe) or Section 5.5, page 14 (remote probe). Referring to Fig. 5.19: 1. Remove the reference air (Ref. Air) fitting A and external test gas (TG1, TG2) fittings B from the probe body inlets C using a 14 mm A/F spanner (not supplied). 2. If fitted, remove existing filter pads D from the probe body TG1, TG2 and Ref. Air inlets. 3. If fitted, remove

  • ABB Endura AZ20 series, Combustion Oxygen Monitor Endura AZ20 Series Probe Appendix B – Probe Electrical Connections IM/AZ20M–EN Rev. B 49 B.3 AutoCal Connections at AZ20 Probe Terminal / Cable Color Tag ID AutoCal Connection White / Yellow PS2 Pressure Switch Gas 2 White / Black PS COM Pressure Switch Common White / Orange PS1 Pressure Switch Gas 1 White / Green SV1 Solenoid Valve Gas 1 White / Red SV CO M Solenoid Valve Common White / Blue SV2 Solenoid Valve Gas 2 Table B.3 AutoCal Connections at Probe Fig. B.2 AutoCal Connections at AZ20 Probe AutoCal terminal plug connected to AutoCal terminal block

Related Products and Documents (Monitor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Compaq 1850R - ProLiant - 128 MB RAM Manual  compaq/1850r-proliant-128-mb-ram-95Y.pdf 10 Oct 2023 11 0.1 Mb
2 Windsor PRS Operating instructions manual windsor/prs-H25.pdf 28 Sep 2023 13
3 Cisco 7945 Installation manual cisco/7945-4U1.pdf 14 Aug 2022 1
4 Clarity p400 Operation & user’s manual clarity/p400-299.pdf 05 Aug 2023 64 1.58 Mb
5 Milwaukee 8975 Operator's manual milwaukee/8975-H6Z.pdf 06 Dec 2023 32
6 Craftsman 580.676642 Operator's manual craftsman/580-676642-LO4.pdf 13 Sep 2023 56 8.9 Mb

Similar Resources:

  • Abex Exhibits

    ELITE GRAPHIC WALL

    (3 pages)
    SPECIFICATIONS / ASSEMBLYELITE GRAPHIC WALL fabric displayELITE GRAPHIC WALL is constructed of aluminum extrusion and features SEG press fit fabric graphics for hassle free set up. Heavy duty aluminum feet ensure maximum stability. Graphics are printed on premium fabric for vibrant colors. The entire unit disassembles and packs flat in a single rotomolded …
  • walser

    walimex pro

    (20 pages)
    08.2019GebrauchsanleitungInstruction Manual 4,5“ Camera Assist Monitor 4K IPSEN Made in ChinaWALSER GmbH & Co. KGSenefelderstrasse 2386368 Gersthofen [email protected]
  • Philips

    4000 series

    (2 pages)
    UM-4 AAAR03 1.5VTAR4406_37_QSG_V1.0www.philips.com/welcomeClock Radio4000 SeriesR4406Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V. and are used under license. This product has been manufactured by and is sold under the responsibility of MMD Hong Kong Holding Limited or one of its aliates, and MMD Hong Kong H …
  • Dell

    M992 - 19" CRT Display

    (4 pages)
    Dell™ M992 Color Monitor Quick Setup Guide 1Dell™ M992 Color MonitorQuick Setup GuideSafety InstructionsObserve the following safety guidelines when connecting and using your monitor:•Be sure that your monitor is electrically rated to operate with the AC power available in your location.•Locate your monitor near an easily accessible electrical outlet …
  • Samsung

    S23A950D

    (81 pages)
    ᔍᬊᯱᖅ໦ᕽ4"%4"%ᯕᱽ⣩ᮡݡ⦽ၝǎᨱᕽอᔍᬊ⦹ࠥಾอॅᨕᲙᯩᮝ໑⧕᫙ᨱᕽ۵⣩ḩᮥᅕ᷾⦹ḡᦫ᜖ܩ݅'03,03&"6/*545"/%"3%0/-:BN46-00035A-00 …
  • LG

    32ML600M

    (28 pages)
    * LG LED Monitor applies LCD screen with LED backlights.Please read this manual carefully before operating your set and retain it for future reference.32ML600M32ML60TMOWNER’S MANUALLED LCD MONITOR(LED Monitor*)www.lg.comCopyright © 2018 LG Electronics Inc. All Rights Reserved. …

Comments, Questions and Opinions: