  • NX-148E LCD Keypad 23 VII. APPENDIX A - EVENT LOG NOTE: Your system may not have all of the features listed in this table. DISPLAY DESCRIPTION TXlobat Transmitter Low Battery The transmitter has a low battery. ZN Lost Zone Lost A wireless or multiplexed zone device is not reporting to the control. Duress Duress The control has been armed or disarmed with a Duress code.

  • GE NX-148E, NX-148E LCD Keypad 3 I. GLOSSARY OF TERMS Abort Delay: An option that allows a delay in reporting to the central station. Authority Level: The level of access an individual has when using an alarm panel. Central Station: Location where alarm data is sent during an alarm report. Chime Feature: An option that allows the keypad to sound a ding-dong whenever an entry/exit door is opened. Codes: Can be either User Codes (relating to a person) or Function Codes (a toggle switch to turn specific functions on/off). NOTE: A system may have either four (4) digit codes or six (6) digit codes, but not a mixture of the two. Duress C

  • NX-148E LCD Keypad 15 READING THE EVENT LOG The control panel has an event log that can be retrieved using a master code. This log contains a listing of the events along with date, time, and partition where the event occurred. Step 1 To view the log, press r 9 0 . The LCD screen will prompt you for a code. Step 2 Enter your ma

  • NX-148E LCD Keypad 24 DISPLAY DESCRIPTION Cancel Cancel System is disarmed and the Cancel button was pressed within 5 minutes of an alarm. Gnd Flt Ground Fault A short to ground has been detected. Man Test Manual Test Bell and/or communicator test while system is in disarmed condition. Re-exit Re-Exit The exit delay has been re-started without disarming the system. O

  • GE NX-148E, NX-148E LCD Keypad 5 III. KEYPAD FUNCTIONS ARMING YOUR SYSTEM IN THE “AWAY” MODE AWAY is utilized when the user is going away from the premise and wants the interior protected. Listed below are the steps to arm in the AWAY Mode: Step 1 Close all protected doors and windows.  Ready light will be on or flashing when all protected zones and sensors are secure. NOTE: If any zones are bypassed, a sensor in that zone can be violated without affecting the ready light.  The security system will not arm if the ready light is off. Refer to "Making Your System R

  • GE NX-148E, NX-148E LCD Keypad 21 VI. SERVICE DISPLAY The following message will be displayed periodically if the security system requires service. Call your service provider promptly if this message is observed. If you see this display, press r 2 One or more of the following fault messages will be displayed. Use the scroll keys • – to browse through them. To exit the service messages, press [#]-[#]. Control Box tamper (Optional) The Box Tamper circuit has activated. Control Fail to Comm. The control attempted to communicate a message to the Central Station, but was unsuccessful. Control Gro

  • GE NX-148E, NX-148E LCD Keypad 16 SETTING THE SYSTEM CLOCK Step 1 Enter r 9 7 . The LCD Screen will prompt for a code. Step 2 Enter [master code]. The time and date will be displayed with the current hour flashing. Step 3 Use the • – scroll keys to select the proper hour. Step 4 Press the r key to move to the minutes, day of week, date, month, and year. Step 5 Repeat Steps 3 and 4 until the entire time and date are set. USING THE DOOR CHIME FEATURE The door chime is tu

  • GE NX-148E, NX-148E LCD Keypad 18 This display is reflecting all 8 areas are Ready, and Area 5 is disarmed. NOTE: If a number is flashing on the Armed line, that area is armed Instant. If a number is flashing on the Ready line, that area is ready to be Force Armed. If ALL areas are disarmed and ready to arm, this display will appear on the LCD screen.  ARMING AND DISARMING MULTIPLE PARTITIONS To arm/disarm multiple partitions, enter a code that has arm/disarm authority for ALL of the partitions to be armed/disarmed. The

  • GE NX-148E, NX-148E LCD Keypad 17 IV. PARTITIONED SYSTEMS OPERATION This system is “ is not “ partitioned. If your system is multi-partitioned and the keypad resides in one partition, your keypad will provide the status of the zones in your partitioning by using the screen messages described earlier in this manual. The Master Mode of operation allows you to temporarily access any partition (providing your code is authorized) within the system and to perform functions in other partitions. Read this entire manual to help you understand the different screen messages that will be displaye

  • GE NX-148E, NX-148E LCD Keypad 10 Select an Option Press  for Help Auxiliary Key - If programmed, you can activate the auxiliary alarm by pressing the Emergency Activation [Auxiliary] key for two seconds. If your system is connected to a monitoring center, an emergency report could be sent to that center. This key should only be pressed in an emergency situation requiring response by emergency personnel. Police (Panic/Hold-Up) Key - If programmed, when the Emergency Activation [Police] key is pressed for two seconds, a local audible alarm will sound. If your

  • GE NX-148E, NX-148E LCD Keypad 7 USING THE QUICK ARM The Quick Arm feature may be used if it is enabled. Quick Arm will allow the user to arm the security system in the AWAY mode by pressing the [EXIT] key. The system can be quick armed in the STAY mode by pressing the [STAY] key. This feature is used for ARMING ONLY, and will not disarm the security system. This is ideal for a maid or baby sitter code, etc. CHANGING MODES WHILE YOUR SYSTEM IS ARMED Step 1 Pressing the [STAY] key will turn on/off (toggle) a delay on Entry

  • NX-148E LCD Keypad 9 If you do not know the number of the zone you wish to bypass, use the following steps: Step 1 Press r • The description for zone 1 will be displayed. Step 2 Use the • – scroll keys to browse through the custom descriptions for the zones in this system. Step 3 To bypass or unbypass a specific zone, press the [BYPASS] key while th

  • GE NX-148E, NX-148E LCD Keypad 14 PROMPT Outputs used? » DO NOT CHANGE THIS SEGMENT! Open / Close Rprt? Bypass enable? Arm / Disarm? (These are for use by a professional installer only.) Master code? Sched arm only? Arm only? Reserved 0=No 1=Yes Your keypress will apply to the user code you entered in Step 3. Output 4 ? Output 3 ? Output 2 ? Output 1? If these messages appear on the LCD screen, press the [r] key until you return to the prompt for the user code or until you exit this adjust mode. Step 4 NOTE: The LCD will now display all of the partitions to which this user has access. If you wish to remove a partition, press the partition number on t

  • GE NX-148E, NX-148E LCD Keypad 19  OPERATING INDIVIDUAL AREAS IN THE MULTI-PARTITION MODE Enter a code that is a valid arm/disarm code for the area you wish to operate. The following display will appear on the LCD screen. Only the areas authorized by this code will appear. To toggle between the armed and disarmed states of an individual area, press [r] [Area number]. To operate an individual area, enter the number of the partition you wish to operate. The LCD keypad will now operate as a single area keypad. All keys and functions entered will affect this individual partition only. The lights and d

  • GE NX-148E, NX-148E LCD Keypad 20 V. KEYPAD CONTROL TONES (BEEPS) A sounder is built into the keypad and may sound for any of the following reasons:  Beeps for all keypresses.  Sounds a continuous tone during the Entry delay time.  Pulses when a day zone is violated while the system is disarmed.  Pulses when a FIRE zone has a trouble condition.  Pulses when the armed status changes and the AC power is off.  Beeps 3 times for trying to arm with the “READY” light

  • GE NX-148E, NX-148E LCD Keypad 2 THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET. FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY. THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBLE LOCATION FOR THE LIFE OF THE SECURITY SYSTEM. IF YOU DO NOT UNDERSTAND ANY PART OF THIS MANUAL, YOU SHOULD NOTIFY YOUR INSTALLING COMPANY. READ THE ENTIRE M

  • GE NX-148E, NX-148E LCD Keypad 4 II. UNDERSTANDING THE LIGHTS Armed Light The armed light is “on” when the system is armed. The armed light is “off” when it is disarmed. The armed light will flash when there has been an alarm during the previous arm cycle. Bypass Light The bypass light is “on” when any zone in this keypad’s partition is bypassed. If the bypass light is “off”, no zones are bypassed. Cancel Light The cancel light will flash during an abort delay time. Entering a code followed by the [CANCEL] key during or after an alarm report to the central station will cause the cancel light to come on. It will stay on until the

  • GE NX-148E, NX-148E LCD Keypad 12 DISPLAY TEST FUNCTION This function will perform a test of the LCD display. No alarms or reports will be sent. Step 1 Press r 4 5 . The test will be performed and all of the display pixels and LED indicators will flash until another key is pressed. Step 2 Press any key to end the test. LIGHT CONTROL FOR X-10 DEVICES (Optional, if programmed) This menu allows you to control up to ten X-10 devices from each keypad. Step 1 Press r 4

More Instructions:

DOWNLOAD

Related Products and Documents (Keypad):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Marantz CDR631 Operation & user’s manual marantz/cdr631-1IK.pdf 19 Oct 2023 29
2 Lennox 10HP12 Information lennox/10hp12-X28.pdf 04 Dec 2022 16
3 Garmin iQue 3600a Operating instructions manual garmin/ique-3600a-3N2.pdf 21 Dec 2022 124 2.6 Mb
4 Red Hat ENTERPRISE LINUX 5 Configuration red-hat/enterprise-linux-5-6KP.pdf 22 Oct 2023 38 0.54 Mb
5 Maytag MEDX5SPAW Installation manual maytag/medx5spaw-7O1.pdf 14 Sep 2023 44
6 Shadow SH075 Owner's manual shadow/sh075-6D6.pdf 09 Sep 2023 6

Similar Resources:

  • Videx

    4000 Series

    (8 pages)
    66251770 - V1.1 - 15/09/19- 1 -4000 Series Vandal Resistant RangeArt.4512 - Installation instructionsArt.4512 IP Audio/video digital front panel Art.4512V Art.4512RVABCDFig. 1 Front4512V4512V/UK4512RV4512RV/UK4512V/F 4512RV/F4512V/NFP 4512RV/NFPMade in ItalyDigital call panel for IP systemCapacitordischargeDry contactoutputINPUTSIN1IN2GNDIRELAY …
  • DMP Electronics

    7760

    (6 pages)
    InstallatIon GuIde7760 LCD Glass KeypadDescriptionThe DMP Model 7760 LCD Glass Keypad offers the same functionality and exible features as standard DMP keypads. The contemporary glass touch design offers an elegant, sleek look to accent any decor. Each 7760 keypad provides a 32‑character touchscreen backlit display, keyboard with easy‑to‑read lett …
  • Inner Range

    4000

    (24 pages)
    1CONCEPT 4000.CONCEPT 4000.CONCEPT 4000.CONCEPT 4000.CONCEPT 4000. Prisma Colour Graphic Terminal User Manual.CONCEPT 4000CONCEPT 4000CONCEPT 4000CONCEPT 4000CONCEPT 4000Prisma Colour Graphic TPrisma Colour Graphic TPrisma Colour Graphic TPrisma Colour Graphic TPrisma Colour Graphic TerminalerminalerminalerminalerminalUser Manual. RUser Manual. RUser Manua …
  • Vimar

    ELVOX 13F4

    (48 pages)
    13F4, 13A4, 13A4.B - 13F7, 13A7, 13A7.BUnità Due Fili audio con tastiera - Unità Due Fili colori con tastierakeypad audio Due Fili unit - keypad colour Due Fili unitManuale installatoreInstaller guide3211 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MNO PQRS TUV WXYZ + R 3211 234567 8 90ABC DEFGHIJKLMNOPQRSTUVWXYZ+R …
  • Resolution

    CryptiX

    (4 pages)
    RE656 Series CryptiX™ HeliPad™HeliPad is an arming station that provides real-time system status. It is battery powered and requires no installation tools. A direct wireless link to Helix allows for local control of the Helix control panel, regardless of network connectivity. Features• E ink® display provides real-time status• Non-mechanical c …
  • xpr

    DINPAD-M

    (12 pages)
    MerkmaleCaracterísticasEigenschappenCaractéristiques• Clavier périphérique multi protocole• Fonctionne sur 12V CC• Compatible avec WIEGAND à 26, 30, 34, 40 bit, Clock & Data ou Codix• 2 LEDs externe pilotables (Rouge & Verte)• Retour acoustique et visuel• Consommation: max. 70 mA• Touches rétro-éclairées• Longueur de code PIN …

Comments, Questions and Opinions: