FSP Technology 1K Operation & User’s Manual

FSP Technology 1K Manual Online:

4.25, 1594 votes
FSP Technology 1K User Manual
FSP Technology 1K User Guide
FSP Technology 1K Online Manual

Text of FSP Technology 1K User Guide:

  • FSP Technology 1K, 1 Table of Contents 1. Important Safety Warning……………………………………………… 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2 1-5. Maintenance, service and faults 3 2. Installation and setup…………………………………………………… 4 2-1. Rear panel view 4 2-2. Setup the UPS 6 3. Operations………………………………………………………………….. 8 3-1. Button operation 8 3-2. LCD Panel 8 3-3. Aud

  • FSP Technology 1K, 2 1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully 1-1. Transportation  Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation  Condensation may occur if th

  • FSP Technology 1K, 3 1-5. Maintenance, service and faults  The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel.  Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.  Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists in

  • FSP Technology 1K, 4 2. Installation and setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. NOTE: There are two different types of online UPS: standard and long-run models. Please refer to the following model table. Model Type Model Type 1K Standard 1KL Long-run 1.5K 1.5KL 2K 2KL 3K 3KL 2-1. Rear panel view 1K(L) / 1.5K(L) TOWER IEC Type Schuko Type India Type Africa Type NEMA Type 2K(L) TOWER

  • 5 1K(L)/1.5K(L) RACK 2K(L) RACK 3K(L) RACK IEC Type IEC Type IEC Type Schuko Type Schuko Type Schuko Type India Type India Type India Type Africa Type Africa Type Africa Type NEMA Type NEMA Type NEMA Type UK Type UK Type UK Type 1. Programmable outlets: connect

  • FSP Technology 1K, 6 9. SNMP intelligent slot 10. External battery connection (only available for L model) 11. Output terminal 12. Output circuit breaker 13. Input terminal 2-2. Setup the UPS Step 1: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords.  For 208/220/230/240VAC models: The power cord is supplied in the UPS package.  For 110/115/120/127VAC models: The power cord is attached to the UPS. The input plug is a NEMA 5-15P f

  • FSP Technology 1K, 7 Step 4: Network connection Network/Fax/Phone surge port Connect a single modem/phone/fax line into surge-protected “IN” outlet on the back panel of the UPS unit. Connect from “OUT” outlet to the equipment with another modem/fax/phone line cable. Step 5: Disable and enable EPO function Keep the pin 1 and pin 2 closed for UPS normal operation. To activate EPO function, cut the wire between pin 1 and pin 2. Step 6: Turn on the UPS Press the ON/Mute button on the front panel for two seconds to power on the UPS. No

  • FSP Technology 1K, 8 3. Operations 3-1. Button operation Button Function ON/Mute Button  Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS.  Mute the alarm: When the UPS is on battery mode, press and hold this button for at least 5 seconds to disable or enable the alarm system. But it’s not applied to the situations when warnings or errors occur.  Down key: Press this button to display previous selection in UPS setting mode.  Switch to UPS self-test mode: Press ON/Mute bu

  • FSP Technology 1K, 9 Display Function Backup time information Indicates the backup time in pie chart. Indicates the backup time in numbers. H: hours, M: minute, S: second Fault information Indicates that the warning and fault occurs. Indicates the warning and fault codes, and the codes are listed in details in 3-5 section. Mute operation Indicates that the UPS alarm is disabled. Output & Battery voltage information Indicates the output voltage, frequency or battery voltage. Vac: output voltage, Vdc: battery voltage, Hz: frequency Load information Indicates the load level by 0-25%, 26-50%, 51-75%, and 76-100%. Ind

  • 10 Input & Battery voltage information Indicates the input voltage or frequency or battery voltage. Vac: Input voltage, Vdc: battery voltage, Hz: input frequency 3-3. Audible Alarm Battery Mode Sounding every 4 seconds Low Battery Sounding every second Overload Sounding twice every second Fault Continuously sounding Bypass Mode Sounding every 10 sec

  • FSP Technology 1K, 11  01: Output voltage setting Interface Setting Parameter 3: Output voltage For 208/220/230/240 VAC models, you may choose the following output voltage: 208: presents output voltage is 208Vac 220: presents output voltage is 220Vac 230: presents output voltage is 230Vac 240: presents output voltage is 240Vac For 110/150/120/127 VAC models, you may choose the following output voltage: 110: presents output voltage is 110Vac 115: presents output voltage is 115Vac 120: presents output voltage is 120Vac 127: presents output voltage is 127Vac

  • FSP Technology 1K, 12 LLS: Low loss voltage in ECO mode in parameter 2. For 208/220/230/240 VAC models, the setting range in parameter 3 is from -7V to -24V of the nominal voltage. For 110/115/120/127 VAC models, the setting voltage in parameter 3 is from -3V to -12V of the nominal voltage.  06: Bypass enable/disable when UPS is off Interface Setting Parameter 3: Enable or disable Bypass function. You may choose the following two options: ENA: Bypass enable DIS: Bypass disable  07: Bypass voltage range setting Interface Setting

  • FSP Technology 1K, 13 3-6. Operating Mode Description Operating mode Description LCD display Online mode When the input voltage is within acceptable range, UPS will provide pure and stable AC power to output. The UPS will also charge the battery at online mode. ECO mode Energy saving mode: When the input voltage is within voltage regulation range, UPS will bypass voltage to output for energy saving. Frequency Converter mode When input frequency is within 40 Hz to 70 Hz, the UPS can be set at a constant output freque

  • FSP Technology 1K, 14 3-8. Warning indicator Warning Icon (flashing) Alarm Low Battery Sounding every second Overload Sounding twice every second Battery is not connected Sounding every second Over Charge Sounding every second Site wiring fault Sounding every second EPO enable Sounding every second Fan Failure Sounding every second Over temperature Sounding every second Charger failure Sounding every second Out of bypass

  • 15 4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy No indication and alarm even though the mains is normal. The AC input power is not connected well. Check if input power cord firmly connected to the mains. The AC input is connected to the UPS ou

  • FSP Technology 1K, 16 display and alarm is continuously sounding. short circuit occurs on the UPS output. short circuit status. Fault code is shown as 1, 2, 3, 4, 11, 12, 13 and 41 on LCD display and alarm is continuously sounding. A UPS internal fault has occurred. There are two possible results: 1. The load is still supplied, but directly from AC power via bypass. 2. The load is no longer supplied by power. Contact your dealer Battery backup time is shorter than nominal value Batteries are not fully charged Charge the batterie

  • FSP Technology 1K, 17 5. Storage and Maintenance 5-1. Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer. Storage Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C Every 3 months 1-2 hours 40°C - 45°C Every 2 months 1-2 hours

  • FSP Technology 1K, 18 6. Specifications CAPACITY* 1000 VA / 800 W 1500 VA / 1200 W 2000 VA / 1600 W 3000 VA / 2400 W INPUT Voltage Range Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or 80 VAC / 70 VAC / 60 VAC / 50 VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) Low Line Comeback 175 VAC ± 5 % or 85 VAC ± 5 % High Line Transfer 300 VAC ± 5 % or 150 VAC ± 5 % High Line Comeback 290 VAC ± 5 % or 145 VAC ± 5 % Frequency Range 40Hz ~ 70 Hz Phase Single phase with ground Power Factor ≧ 0.99 @ 220-2

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sanyo VCC-HD2500 - Full HD 1080p Network Camera Manual  sanyo/vcc-hd2500-full-hd-1080p-network-camera-735.pdf 29 Aug 2022 148 26.66 Mb
2 New Holland 50CS Specifications new-holland/50cs-YVU.pdf 25 Sep 2023 1
3 JCV RX-DV3SL Service manual jcv/rx-dv3sl-GVJ.pdf 17 Oct 2023 28
4 Gigabyte GV-3D1-7950-RH Operation & user’s manual gigabyte/gv-3d1-7950-rh-FAL.pdf 19 Oct 2022 34 5.62 Mb
5 Kenmore 86050 Operation & user’s manual kenmore/86050-2PG.pdf 30 Apr 2023 16
6 Buffalo TeraStation WSS 5000 Operation & user’s manual buffalo/terastation-wss-5000-21O.pdf 06 Nov 2022 67 2.46 Mb

Similar Resources:

  • LEGRAND

    MyHOME F455

    (3 pages)
    www.homesystems-legrandgroup.comLE05548AA-01PC-14W41F4551. User interface LED: see table2. Connection to the SCS BUS3. Ethernet connection4. Reset key: – to set the fixed network address 192.168.1.5, power the device keeping the pushbutton pressed for 3 seconds (the red LED goes off) – press and hold for 10 seconds to restart the Gateway basic; – pr …
  • ETA Systems

    350VA

    (105 pages)
    ETA Systems 1450 Lakeside Drive Waukegan, IL 60085 Phone: (330) 425-3388 Fax: (330) 425-9700 Toll Free: (800) 321-6699 On the web @ http://www.etasys.com © 2005 ETA Systems SM 5501-RevA Uninterruptible Power Manager 350VA, 500VA, 800VA, 1100VA, 1440VA Managed Power Us …
  • Delta

    M Series

    (63 pages)
    M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-USSolar Inverters for North America Single Phase Solar Inverters for North AmericaM4-TL-US | M5-TL-US | M6-TL-US | M8-TL-US | M10-TL-US Key Features:  Smart inverter with Bluetooth, optional WiFi, Zigbee, 3G/4Gcellular communication Field upgrade-able from solar inverter (M6, M8) to storage systemby …
  • CyberPower

    CP850AVRLCD

    (2 pages)
    Yellow Wire to (+)Red Connector Black Wire to (-)Black Connector Red Wire to (+)Red Connector Yellow Wire to (-)Black Connector CP850/1000/1350/1500AVRLCD User’s Manual Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at www.cpsww.com/registration. Registration certifies your product's warran …
  • Eaton

    PowerXpert 9395P-600/600

    (232 pages)
    Eaton PowerXpert 9395 High Performance (9395P-600) UPSInstallation and Operation ManualFor use with 380V, 400V, 415V, and 480V Single UPM (200–300 kVA),Two UPM (400–550 kVA), and Plus 1 (400–600 kVA) UPS ModelsAlso for use with 600V Single UPM (200–275 kVA), Two UPM (300–550 kVA),and Plus 1 (300 kW-550 kW)®® …
  • König Electronic

    CMP-UPS3000

    (45 pages)
    2012-10-16 CMP-UPS3000 MANUAL (p. 2) UPS 3000VA ANLEITUNG (S. 4) USV 3000VA MODE D’EMPLOI (p. 7) Onduleur 3000 VA GEBRUIKSAANWIJZING (p. 10) UPS 3000VA MANUALE (p. 13) UPS 3000VA MANUAL DE USO (p. 16) UPS 3000VA HASZNÁLATI ÚTMUTATÓ (o. 19.) UPS (szünetmentes tápegység) 3000 VA KÄYTTÖOHJE (s. 22) UPS 3000VA BR …

Comments, Questions and Opinions: