Manualios.com

EOTL Otima 800 Operation & User’s Manual

EOTL Otima 800 Manual Online:

3.25, 1411 votes
EOTL Otima 800 User Manual
EOTL Otima 800 User Guide
EOTL Otima 800 Online Manual

Text of EOTL Otima 800 User Guide:

  • 1 Table of Contents 1. Important Safety Warning……………………………………………… 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation 2 1-5. Maintenance, Service And Faults 3 2. Installation And Setup…………………………………………………… 4 2-1. Rear Panel View 4 2-2. Install The UPS 5 2-3. Setup The UPS 6 2-4. Battery Replacement

  • EOTL Otima 800, 2 1. Important Safety Warning Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and read carefully the following instructions before installing the unit. Do not operate this unit before reading through all safety information and operating instructions carefully 1-1. Transportation  Please transport the UPS system only in the original package to protect against shock and impact. 1-2. Preparation  Condensation may occur if the UPS system is moved directly from

  • EOTL Otima 800, 3 1-5. Maintenance, Service And Faults  The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel.  Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery and electrically live and dangerous.  Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no current is present and no hazardous voltage exists in the terminals of high capability capacitor such as BUS-capacitors.  O

  • EOTL Otima 800, 4 2. Installation And Setup NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please keep the original package in a safe place for future use. 2-1. Rear Panel View 800/1.1K 1.5K/2K 2.5K/3K 1. Programmable outlets: connect to non-critical loads. 2. Output receptacles: connect to mission-critical loads. 3. AC input 4. Input circuit breaker 5. Network/Fax/Modem surge protection 6. Emergency power off function connector (EPO) 7. USB communication port 8. RS-232 communication port 9. SNMP intelligent slot 10.Output circuit breaker

  • EOTL Otima 800, 5 2-2. Install The UPS For safety consideration, the UPS is shipped out from factory without connecting battery wires. Before install the UPS, please follow below steps to re-connect battery wires first. Step 1 Step 2 Step 3 Remove front panel. Re-connect battery wires. Put the front panel back to the unit. Rack-mount Installation Step 1 Step 2 Tower Installation Step 1 Step 2 Step 3

  • EOTL Otima 800, 6 2-3. Setup The UPS Step 1: UPS input connection Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. Step 2: UPS output connection  For socket-type outputs, there two kinds of outputs: programmable outlets and general outlets. Please connect non-critical devices to the programmable outlets and critical devices to the general outlets. During power failure, you may extend the backup time to critical devices by setting shorter backup time for non-critical devices. Step 3: Communication connection Communication port: USB port RS-232 port Intelligent slot To all

  • EOTL Otima 800, 7 Step 6: Turn on the UPS Press the ON/Mute button on the front panel for two seconds to power on the UPS. Note: The battery charges fully during the first five hours of normal operation. Do not expect full battery run capability during this initial charge period. Step 7: Install software For optimal computer system protection, install UPS monitoring software to fully configure UPS shutdown. Please follow steps below to download and install monitoring software: 1. Go to the website http://www.power-software-download.com 2. Click ViewPower software icon and then choose your required OS to download the software. 3. Follow the on-screen instructions to install the software. 4. When your comput

  • 8 3. Operations 3-1. Button Operation Button Function ON/MUTE Button  Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn on the UPS.  Mute the alarm: After the UPS is turned on in battery mode, press and hold this button for at least 5 seconds to disable or enable the alarm system. But it’s not applied to the situations when warnings or errors occur. �

  • EOTL Otima 800, 9 Display Function Backup time information Indicates the backup time in pie chart. Indicates the backup time in numbers. H: hours, M: minute Warning & Fault information Indicates that the warning and fault occurs. Indicates the warning and fault codes, and the codes are listed in details in 3-5 section. Setting Operation Indicates the setting operation. Input/Output & Battery information Indicates the output/input voltage, output/input frequency or battery voltage. V: voltage, Hz: frequency Load information Indicates the load level by 0-25%, 26-50%, 51-75%, and 76-100%. Indicates overload. Indicates the load

  • EOTL Otima 800, 10 3-4. LCD Display Wordings Index Abbreviation Display content Meaning ENA Enable DIS Disable ESC Escape EP EPO FA Fan TP Temperature CH Charger RAC Rack display TOE Tower display SF Site Fault 3-5. UPS Setting There are two parameters to set up the UPS. Parameter 1: It’s for program alternatives. There are 4 programs to set up: output voltage setting, , programmable outlets enable/disable, programmable outlets setting , LCD display direction and exit.  01: Output voltage setting Interface Setting For 208/220/230/240 VAC models, you may choose the following output voltage: 208: presents output voltage is 208Vac 220: presents output voltage is 220Vac 230: presents output voltage

  • EOTL Otima 800, 11  03: Programmable outlets setting Interface Setting Setting the backup time limits in minutes from 0-999 for programmable outlets which connect to non-critical devices on battery mode.  04: LCD display direction setting Interface Setting RAC: the LCD display is horizontal. TOE: the LCD display is vertical.  00: Exit setting

  • 12 3-6. Operating Mode Description Operating mode Description LCD display ECO mode When the input voltage is within voltage regulated range, UPS will power the output directly from the mains. Buck mode when AC is normal. When the input voltage is higher than the voltage regulation range but lower than high loss point, the buck AVR will be activated. Boost mode when AC is normal. When the inp

  • EOTL Otima 800, 13 3-8. Warning Indicator Warning Icon (flashing) Alarm Low Battery Sounding every second Overload Sounding twice every second Battery is not connected Sounding every second Overcharge Sounding every second Site wiring fault Sounding every second EPO enable Sounding every second Fan Failure Sounding every second Over temperature Sounding every second Charger failure Sounding every second Battery Fault Sounding every second

  • EOTL Otima 800, 14 4. Troubleshooting If the UPS system does not operate correctly, please solve the problem by using the table below. Symptom Possible cause Remedy The AC input power is not connected well. Check if input power cord firmly connected to the mains. No indication and alarm even though the mains is normal. The AC input is connected to the UPS output. Plug AC input power cord to AC input correctly. The icon and the warning code flashing on LCD display and alarm is sounding every second. EPO function is activated. Set the circuit in close position to disable EPO function. The icon and flashing on LCD display and alarm is sounding

  • EOTL Otima 800, 15 Symptom Possible cause Remedy Fault code is shown as 1, 2, 3, 4, 11, 12, 13 and 41 on LCD display and alarm is continuously sounding. A UPS internal fault has occurred. Contact your dealer Batteries are not fully charged Charge the batteries for at least 5 hours and then check capacity. If the problem still persists, consult your dealer. Battery backup time is shorter than nominal value Batteries defect Contact your dealer to replace the battery. The icon and the warning code flashing on LCD display and alarm is sounding every second. Fan is l

  • EOTL Otima 800, 16 5. Storage and Maintenance 5-1. Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer. Storage Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage, recharge the battery in accordance with the following table: Storage Temperature Recharge Frequency Charging Duration -25°C - 40°C Every 3 months 1-2 hours 40°C - 45°C Every 2 months 1-2 hours Be sure to deliver the spent batte

  • 17 MODEL Otima 800 Otima 1.1K Otima 1.5K Otima 2K Otima 2.5K Otima 3K CAPACITY 800 VA / 640 W 1100 VA / 880 W 1500 VA / 1200 W 2000 VA / 1600 W 2500 VA / 2000 W 3000 VA / 2400 W INPUT Acceptable Voltage Range 81-145 VAC or 162-290 VAC Frequency Range 60/50 Hz (auto sensing) OUTPUT Voltage Regulation (AC Mode) 110/120 VAC or 208/220/230/240 VAC Voltage Regulation (Batt. Mode) ±3

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Bakers Pride HDTG-2424 Installation and operating instructions manual bakers-pride/hdtg-2424-4ZG.pdf 11 Oct 2022 20
2 ADTRAN 1224 Installation and maintenance practice adtran/1224-815.pdf 11 Dec 2022 220 4.08 Mb
3 BK Precision 1760A Instruction manual bk-precision/1760a-U96.pdf 23 Nov 2023 50
4 Kennedy Instruments K.I. Monobar Type U Instructions manual kennedy-instruments/ki-monobar-type-u-RE7.pdf 28 Aug 2022 8
5 Furious FPV Fortini F4 OSD Operation & user’s manual furious-fpv/fortini-f4-osd-U2E.pdf 10 Feb 2024 34
6 Advance acoustic Condor 4030C Instructions for use & warranty advance-acoustic/condor-4030c-6I8.pdf 02 Sep 2023 52

Similar Resources:

  • Sola HD

    s3k1000

    (15 pages)
    2Uninterruptible Power SuppliesThe S5KC Modular UPS is scalable from 5 to 20 kVA, offering many exible options by adding a few standard modules. Designed to be fully congured, tested and shipped in the conguration you need, the S5KC Modular UPS also has the ability to be easily upgraded in the eld to either higher VA ratings (up to 20 kVA maximum …
  • GE

    VH 700

    (2 pages)
    GE Digital Energy’s™ VH Series of UPS is a true VFI (Voltage & Frequency Independent) on-line double conversion, intelligent and high-performance UPS designed for all mission-critical applications. The UPS range is designed with a unique failsafe bypass providing maximum security and reliability for the user. The VH Series range of UPS has been desig …
  • Intex

    KOM0036

    (20 pages)
    PLDEROENUser's manualInstrukcja obsługiManual de utilizareBedienungsanleitungKOM0036Uninterruptable power supplyINTEX UPSDear user: Thank you for purchasing INTEX product. You are sincerely recommended to read this manual carefully & completely prior to use for best usage of this device. …
  • ABB

    PowerValue 11 RT

    (45 pages)
    l�un I Jet , ИБП ABB Powervalue 11 RT (6-10 кВА) - руководство по эксплуатации. ЮниджетПостоянная ссылка на страницу: https://www.uni-jet.com/catalog/istochniki-besperebojnogo-pitaniya/on-line-ibp-1-kva-10kva/abb-powervalue-11- …
  • Eaton

    Evolution 650

    (158 pages)
    www.eaton.comInstallation and user manualEnglishFrançaisDeutschItalianoEspañolNederlandsEvolution650 / 650 Rack 1U850 / 850 Rack 1U1150 / 1150 Rack 1U1550 / 1550 Rack 1UPulsar Series …
  • Vertiv

    Liebert PSA4

    (2 pages)
    590-1559-501A/SL-23307_REV0_3-171LIEBERT® PSA4™Quick Installation GuideBefore installing, operating, or maintaining your Liebert PSA4 UPS Please review these important safety instructions. For detailed operating, maintenance, and troubleshooting information, refer to the User Manual included on CD with the UPS.CAUTION: Connect the UPS only to a properly g …

Comments, Questions and Opinions: