Euroheat thermodual tda 30 Installation & Servicing Instructions Manual
|
IN1233 Edition 2 Installation Servicing Instructions 27 TDA Thermodual Installation Manual Install the thermal safety device onto the connections on the rear of the boiler. Ensure the arrow marked on the body of the thermal safety device is consistent with the direction of the flow of the water to the boiler. Insert the sensor pocket and sensor of the t
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 25 TDA Thermodual Installation Manual Install the buffer layering valve between the accumulator and return temperature kit as per the diagram below. 9.10 Buffer Layering Valve A-B-AB Valve I-II-III Valve II III I Description I Return to boiler II Return from accumulator middle III Return from accumulator bottom Set Valve to normally open Description AB Return to boiler B Return from accumulator middle A Return from accumulator bottom Set valve to normally open AB B A Install auto air vents on all pipework where air may get trapped in the system. Ensure the automatic air vents
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 13 TDA Thermodual Installation Manual 7. Boiler Assembly Approved Document B, of the Building Regulations states that boiler houses are classed as “places of special fire hazard”. Requirements The requirements for a designated compartment is that the responsible person must carry out a risk assessment for the location and take into account the requirements of the Building Regulations Approved Document B1 and B2 (For larger dwellings over 200 m2 per storey). As a “Places of Special fire Hazard” there must be a sep
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 40 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions 1 2 3 1 2 3 PE N L Mini Mate N Lok 3 poles plug with bushing contact Silicon wire SIHF 3 x 0.75mm² L = 2650 Mini Mate N Lok 3 poles adapter with pin contact Extension Storage Motor No. 3 1 2 3 M Silicon wire SIHF 3 x 0.75mm² L = 2700 Tilting Magnet with Door Switch No. 6/7 Connector Plug GDM Tilting Magnet 4 Com Com 5 3 3 TK 1 TK 2 Silicon wire SIHF 2 x 0.75mm² L = 750 Con
IN1233 Edition 2 Installation Servicing Instructions 33 TDA Thermodual Installation Manual Connect the actuator of the buffer layering valve onto the main control board output number 22. The layering valve should be connected as follows 10.8 Buffer Layering Valve A-B-AB Valve I-II-III Valve II III I Description I Return to boiler II Return
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 17 TDA Thermodual Installation Manual Connect the flue starter onto the flue spigot located on the rear of the boiler and ensure an airtight seal using a suitable high temperature sealant. Drill through the flue starter stand and bolt to the two support brackets of the flue starter. Mount the flue draught stabiliser onto the branch at the base flue starter. Connect the drain plug on the base of the flue starter kit to a copper pipe and drain to waste. 7.8 Connecting the Flue
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 15 TDA Thermodual Installation Manual The boiler should be installed on a non-combustible surface of a suitable construction. Adjust the four legs on the base of the boiler so that it stands evenly or slightly raised to the rear. 7.5 Siting the Boiler Adjustable Legs Place the ash tray in front of the assembled boiler. 7.6 Fitting the Ash Tray
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 36 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions Flame Probe X 15 Mini Mate N Lok 2 poles plug with bushing contact white green Silicon Wire green mantled 2500 Flamr Probe NiCrNi Flame sensor 15 Safety Temperature Limiter X11 1 2 3 4 1 2 C T1 STL 11 Boiler Sensor KTY81 - 210 X14 230V DC 1 2 F1 Boiler sensor 14 1 2 3 Draught Fan X10 230V AC M M3 PE L N N PE L Induced draught fan 10 Lambda probe with transformer 16 65 3 4 21 16 Mini Mate-N-Lock 6 pol connector Lambda cable 1 2 4 5 11.3 Electrical connection for flame sensor 11.4 Electrical connection for flame s
IN1233 Edition 2 Installation Servicing Instructions 43 TDA Thermodual Installation Manual 13. Overview of Important Points The warranty is dependent on correct installation by an a Euroheat approved installation partner. The system must be commissioned prior to operation by a Euroheat service engineer. The Thermodual TDA is
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 32 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions Connect the return temperature sensor to the EW1 extension module input 55. To ensure an accurate reading, the return temperature sensor should be located on the return to the boiler in an immersion sleeve in the main flow of water. 10.7 Return Temperature Sensor The temperature sensor must always be in the water flow. Connect the pump of the return temperature kit to the main control board output number 12. Connect the three way v
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 4 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions Contact with the hot surfaces of the boiler can lead to burns. Wait until the boiler has cooled down before touching uninsulated components. Danger of asphyxiation and explosion from carbon monoxide. When the boiler is in operation, carbon monoxide escaping from opened cleaning or inspection hatches can pose a danger of asphyxiation or explosions. Do not leave these open any longer than necessary. Opening doors and lids to hot combustion residues can pose the danger of fires. Keep the openings closed during
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 38 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions 11.7 Electrical connection for lambda sensor Flame Probe X 15 Mini Mate N Lok 2 poles plug with bushing contact white green Silicon Wire green mantled 2500 Flamr Probe NiCrNi Flame sensor 15 Safety Temperature Limiter X11 1 2 3 4 1 2 C T1 STL 11 Boiler Sensor KTY81 - 210 X14 230V DC 1 2 F1 Boiler sensor 14 1 2 3 Draught Fan X10 230V AC M M3 PE L N N PE L Induced draught fan 10 Lambda probe with tran
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 34 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions Install the outdoor temperature sensor in a shady location, out of the wind and on the North side of the property. Connect the sensor to the main control board input number 31. 10.9 Outdoor Temperature Sensor
TDA Thermodual Installation Manual 28 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions Socket for EW1 Cable 4 RS 485 - DATA LINE TO BUSMODULE’S 5 DISPLAY BOARD 12 34 123 123 3 STORAGE AUGER 2 INSERTION AUGER 123 10 DRAFT FAN 1 2 1 IGNITION PE N LT LH PE N L 19 Motor Heat- exchanger/ Turbine (LT)
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 2 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions EASY AND SAFE OPERATION This operating manual contains important instructions on the • SHT TDA Thermodual 30 • SHT TDA Thermodual 40 READING THE INSTALLATION MANUAL This installation manual must be read and applied by everyone who operates or works on the heating system SHT TDA Thermodual TECHNICAL CHANGES We continuously develop and improve our boilers. The information in this edition was correct at the time of going to press. All details in these instructions on standards, regulations and worksheets should be
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 41 TDA Thermodual Installation Manual The below are additional electrical connections that may be used if using the full functionality of the TDA Thermodual boiler. Connect the three port mixing valve of heating circuit 1 pump station to the main control board output 24. Connect the pump of heating circuit 1 pump station to the main control board output 23. Connect a temperature sensor to the flow pipe on the heating side of the heating ci
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 6 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions TDA rear view (with casing) TDA right side view (with casing) TDA front view (with casing) TDA left side view (with casing) 4. Technical Data
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 22 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions 9.3 Pipework Sizing The boiler to accumulator pipework should be a minimum of 32mm diameter. 9.4 Boiler Flow and Return Opposite sides of the boiler must be used for the boiler flow and return to ensure sufficient heat transfer. Ensure the unused connections are blanked off. Option 1 Option 2
Euroheat thermodual tda 30, TDA Thermodual Installation Manual 10 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions A C C B B Legend TDA 30/40 A 2875 B 2260 C 2500 Legend TDA 30/40 A 3270 B 2750 C 2357 6.1 Minimum Boiler Room Sizing with Single 2500 Litre Accumulator 6. Boiler Room Sizing 6.2 Minimum Boiler Room Sizing with Twin 1250 Litre Accumulators
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 31 TDA Thermodual Installation Manual Connect the upper and lower accumulator sensors to the main control board inputs number 36 and 37 respectively. The sensors should be located into the accumulator as illustrated below. 10.4 Accumulator Sensors Upper accumulator sensor position Lower accumulator sensor position Connect the low pressure switch into the main control board input number 29. The low pressure switch should be located between the return temperature kit and boiler, and located on a branch above the pipework. 10.5 Low Pressure Switch
TDA Thermodual Installation Manual 14 IN1233 Oct 2014 Edition 5 Installation Servicing Instructions 7.3 Unhinge Doors Before lifting the boiler off the pallet, we recommend unhinging both the filling and the ash door. Please put them down carefully to avoid any damage. Do not unscrew the hinges on the boiler side panels as the doors may become mi
Euroheat thermodual tda 30, IN1233 Edition 2 Installation Servicing Instructions 37 TDA Thermodual Installation Manual 11.5 Electrical connection for boiler sensor Flame Probe X 15 Mini Mate N Lok 2 poles plug with bushing contact white green Silicon Wire green mantled 2500 Flamr Probe NiCrNi Flame sensor 15 Safety Temperature Limiter X11 1 2 3 4 1 2 C T1 STL 11 Boiler Sensor KTY81 - 210 X14 230V DC 1 2 F1 Boiler sensor 14 1 2 3 Draught Fan X10 230V AC M M3 PE L N N PE L Induced draught fan 10 Lambda probe with transformer 16 65 3 4 21 16 Mini Mate-N-Lock 6 pol connector Lambda cable 1 2 4 5 Flame Probe X 15 Mini
Crown Boiler CSC Series Boiler Installation instructions manual
CSC Series |
IDEAL HE15 Boiler Installation and servicing
HE15 |
RBI FUTERA III Series Boiler Installation & operation manual
FUTERA III Series |
PEERLESS LC SERIES Boiler Installation, operation & maintenance manual
LC SERIES |
Alpha Alpha CombiMax 350 Boiler Installation manuallines
Alpha CombiMax 350 |
CleaverBrooks CFC ClearFire Boiler Operation & user’s manual
CFC ClearFire |
NTI Ti100-200 Boiler Installation and operation instructions manual
Ti100-200 |
Lochinvar Power-Fin Boiler Designer's manual
Power-Fin |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Arbor Technology | ITX-i45M2 | Operation & user’s manual | arbor-technology/itx-i45m2-XQE.pdf | 05 Jun 2023 | 88 | |
2 | Hamilton Beach | 37532 - 20 Cup Capacity Rice Cooker | Operation & user’s manual | hamilton-beach/37532-20-cup-capacity-rice-cooker-LZZ.pdf | 16 Aug 2022 | 14 | 0.18 Mb |
3 | ROBINHOOD | RWH3CH6SS | Installation and operation instructions manual | robinhood/rwh3ch6ss-6EG.pdf | 14 Dec 2022 | 10 | |
4 | TEFAL | Oleoclean Thermostat | User instructions | tefal/oleoclean-thermostat-479.pdf | 03 Aug 2023 | 14 | 1.03 Mb |
5 | Kaiser Baas | KBA03034 | Manual | kaiser-baas/kba03034-7ZT.pdf | 25 Mar 2023 | 2 | |
6 | HP | Officejet Pro K5300 | Quick start | hp/officejet-pro-k5300-1W9.pdf | 14 Oct 2022 | 2 |
AHRI
Cast Iron Gas BoilerFor Forced Hot WaterINSTALLATION, OPERATION & MAINTENANCE MANUALModels BWBBAN000045BWBBAN000070BWBBAN000096BWBBAN000120BWBBAN000145BWBBAN000170BWBBAN000195BWBBAN000245BWBBAN000295P/N IM-BWBB-01[240011111 REV B, 6/30/2016]
…
BWBBAN000045(32 pages) |
Evo HE
Advanced High Efficiency BoilersInstallation & Servicing InstructionsSee reverse for evo HE Users GuideManufactured exclusively for Wolseley Centers Ltd. by Ideal BoilersFor details of document amendments, refer to page 3 H12, H16, H19, H22(V3 Flue System)Wall mounted, balanced flue, fanned gas boilerOctober 2007 UIN 203323 A02203323-2.pmd 21 …
H12(56 pages) |
Dunkirk
An ISO 9001-2008 Certified CompanyDUNKIRK BOILERS2201 Dwyer Avenue, Utica NY 13504-4729web site: www.ecrinternational.comXEB SeriesGas-Fired Hot Water Induced Draft BoilersINSTALLATION, OPERATION & MAINTENANCE MANUALP/N 14683001 Rev. C [06/2011]Tested for 50 psi. ASME Working PressureC.S.A. Certied for Natural gas or PropaneH
…
XEB-2(32 pages) |
Wolf
Instructions for conversion to LPG P (G31)Gas condensing boilers MGK-130Conversion kit, product no. 87 51 351 from G20 to G31Document no. 3062883_0910 SubjecttotechnicalmodicationsGBThese installation instructions are to be retained by the user.We cannot accept any warranty claims if these operating instructions have not been observed.Wolf Gm …
MGK-130(16 pages) |
VOKERA
Installation& ServicingInstructionsTHESE INSTRUCTIONSTO BE RETAINEDBY USERVokèra is a licensed member of the Benchmark schemewhich aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.Mynute VHEHigh efficiency open vent boiler
…
Mynute VHE(40 pages) |
Baxi
DINt-LJnFl=EET|-rlFETFI'THeatinsMode -. _ -'-e ffiffiffiffiiiliffiffi!fi *l,Zstandby U'l*li-fi-f jI L-Auroma.c uooe,€ ?iuu.# a<=Manual mode --;,3 &N&NW,, r"#, 3=Delayed mode/ ----*:-J ------ -'--- -\Time switch programDomestic Hot water Mode histogram /----'\-------:::--- /---,-y'Time tormat / displaying Week …
Luna 3 Comfort(5 pages) |
AMX Switch NXA-ENET24AMX NXA-ENET24 User Manual (Doc Type: Switch Quick start manual) NXA-ENET24, 2 |
Epson Projector BrightLink 475WiBrightLink 475Wi (Projector ePDF Guide, #F85A96) BrightLink 475Wi, 88 |
Omron Server CX-SERVEROmron Product User Guide: CX-SERVER PDF Brochure - 2F4LWI CX-SERVER, 8 |
Cooper Lighting Indoor Furnishing Lumark VLCooper Lighting Lumark VL User Guide (Doc Type: Indoor Furnishing Specification sheet) Lumark VL, 1 |
Hitachi VCR VT-FX760EUKNHitachi VT-FX760EUKN VCR Instruction manual VT-FX760EUKN, 70 |
Anonabox Network Router The OriginalPDF Guide (@9ADDUA), Anonabox The Original Network Router (24/11/2023) The Original, 20 |
Siemens Desktop Simatic PC Panel PC 870Start-up instructions for Siemens Simatic PC Panel PC 870 Desktop Simatic PC Panel PC 870, 68 |
Russound Speakers SP503.1Russound Product Manual: SP503.1 PDF Instruction manual - 19PG36 SP503.1, 12 |
Sunbeam Microwave Oven SBMW709BLSSunbeam SBMW709BLS Guide (Owner's use and care manual), @4E1F6V SBMW709BLS, 22 |
Novus Security Camera NVC-DN6112MSD-IINovus NVC-DN6112MSD-II Guide (Operation & user’s manual), @N3561D NVC-DN6112MSD-II, 72 |
IVIEW MP3 Player iVIEW-760PDVXIVIEW MP3 Player iVIEW-760PDVX Operation & user’s manual iVIEW-760PDVX, 9 |