Manualios.com

Evolution Air DM400 Owner's Manual

Evolution Air DM400 Manual Online:

4.15, 2146 votes
Evolution Air DM400 User Manual
Evolution Air DM400 User Guide
Evolution Air DM400 Online Manual

Text of Evolution Air DM400 User Guide:

  • Evolution Air DM400, OWNER’S MANUAL MODEL DM400 WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT Features • Long-life, HEPA (High Efficiency Particulate Air) Media Filter is 99.97% efficient at removing particles 0.3 micron • MERV 11 Prefilter removes lint and large particles to extend life of HEPA Filter • Activated Carbon Prefilter removes unpleasant odours • Easy-to-change filters • Powerful motor delivers 320 CFM of filtered air • Heavy gauge steel cabinet and powder-c

  • Evolution Air DM400, SAFETY CONSIDERATIONS Read and follow instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage the HEPA Air Cleaner. Understand the signal words WARNING and CAUTION which are present in the Owner’s Manual. WARNING and CAUTION signify a hazard which could result in property damage, personal injury or death. Only a heating/air conditioning installer or qualified

  • Evolution Air DM400, 3. Tape the mounting template level on the plenum and proceed to cut and drill the necessary holes as marked. 4. Cut the small joints on the mounting flaps on the back of the unit as indicated. Bend all the flaps outward slightly less than 90 degrees, except for the upper bottom flap which is only bent up 45 degrees. This bottom flap will act as a deflector for the exhaust air entering back into the plenum. 5. Place the gasket material around the two openings on the back of the air cleaner. Place the unit on the plenum so the flanges are placed through the holes cut in the duct. Fold all the flange

  • OPERATING INSTRUCTIONS The HEPA Air Cleaner is designed to run continuously to provide clean, filtered air 24 hours a day. The fan on the heating/cooling system, to which the HEPA Air Cleaner is dependent on for circulated air, should be on ‘continuous’. Note: If the system fan setting is on ‘automatic’, it is recommended the HEPA Air Cleaner be operated

  • Evolution Air DM400, Dimensions Height Width Depth 20.125 in 16.25 in 12.75 in 51.1 cm 41.3 cm 32.4 cm Intake 14.5 x 3.75 in or 8 in (dia) 36.8 x 9.5 cm or 20.3 cm (dia) Outflow 14.5 x 4.37 in or 8 in (dia) 36.8 x 11.1 cm or 20.3 cm (dia) Unit Weight 38 lbs 17.2 kg Input Voltage 120 V 60 Hz Power Consumption 125 Watts Air Flow 320 CFM 544 m³/hr Cabinet 22 gauge Power Cord 10.0 ft 3.05 m Filter Dimensions Prefilter Carbon Prefilter HEPA Filter 16 x 12 x 1 in

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Belkin F8V3080 - TuneCast II Mobile Transmitter Operation & user’s manual belkin/f8v3080-tunecast-ii-mobile-transmitter-XQE.pdf 14 Jan 2023 14 0.97 Mb
2 Triarch Indoor Lighting 39661 Instructions triarch/indoor-lighting-39661-L56.pdf 28 Jan 2024 1 0.29 Mb
3 Peak PCAN-DONGLE IPEH-002015 Operation & user’s manual peak/pcan-dongle-ipeh-002015-81X.pdf 02 Aug 2022 23 1.27 Mb
4 Ricoh FAX75 Operator's manual ricoh/fax75-4RV.pdf 11 Dec 2022 130 4.86 Mb
5 TracRac SKU# 00-25850 Installation manual tracrac/sku-00-25850-QU4.pdf 12 Mar 2023 4 2.39 Mb
6 Wedge Innovations SmartLevel Owner's manual wedge-innovations/smartlevel-SUG.pdf 17 Mar 2023 13 0.79 Mb

Similar Resources:

  • Filtrete

    FAP-T02

    (40 pages)
    Air Purifier Model SeriesSerie de Modelos de Purificadores de AirePurificateurs d’air des séries FAP-T02, FAP-T03Room Air PurifierPurificador de aire Filtrete™Purificateur d’air FiltreteMCFor more information go to www.filtrete.comPara mayor información visite: www.filtrete.comPour obtenir de plus amples renseignements, consulter le site www …
  • Grizzly

    G0573

    (24 pages)
    TWO SPEED FLOOR AIR FILTERMODEL G0573INSTRUCTION MANUALCOPYRIGHT © DECEMBER, 2004 BY GRIZZLY INDUSTRIAL, INC.WARNING: NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL, INC. #BL6811 PRINTED IN CHINA …
  • IQAir

    Allergen 100

    (1 pages)
    TECHNICAL INFORMATIONModel Allergen 100 HealthPro 150 HealthPro 250 GC MultiGasAir delivery per fan speed in m3/h 40 70 110 150 240 380 40 80 140 190 240 350 40 80 150 200 240 380 40 85 150 210 260 360Weight incl. filters approx.12 kg approx.14 kg approx.16 kg approx.20 kgPower requirements 220 – 240 V / 50 – 60 HzEnergy consumption 20 –160 WDimension …
  • Sanyo

    ABC-VW24A - Air Washer Plus™

    (32 pages)
    ABC-VW24AEnglishFrançaisINSTRUCTION MANUALMANUEL DE L'UTILISATEURAIR PURIFIERPURIFICATEUR D’AIR PageEnglish E-1 – E-14FrançaisF-1 – F-14Thank you for purchasing this air purifier. Be sure to read this instruction manual thoroughly to ensure correct use.Nous vous remercions d’avoir acheté ce purificateur d’air. Veillez à lire complète …
  • Hama

    00186437

    (64 pages)
    Link to Appde.hama.com/smarthome#smart-solutionSmartAir PurierLuftreiniger00186437ESKFDGBISPLRUSHBGCZTRFINROGRNLPOperating InstructionsBedienungsanleitungMode d‘emploiInstrucciones de usoGebruiksaanwijzingIstruzioni per l‘usoInstrukcja obsługiHasználati útmutatóManual de utilizareNávod kpoužitíNávod na použitieManual de instruçõesBruksanvis …
  • GeneralAire

    Mini Mac 1200

    (2 pages)
    FORM NO. 14055 Rev. AThis air cleaner is designed for use in systems up to 1200 CFM. For higher airflows additional units may be required. See Typical Installations below.FOR INSTALLATION IN THERETURN AIR DUCT OF ANYFORCED AIR HEATING ANDCOOLING SYSTEMINSTALLER: PLEASE FILL OUT AND MAIL GUARANTEE CARD AFTER INSTALLATION IS COMPLETE. LEAVE INS …

Comments, Questions and Opinions: