  • FireAngel W2-CO-10X, Installation and User Guide Carbon Monoxide Alarm 10 Year Life Model W2-CO-10X Drawing No: GN3231 Revision: 3 Drawn By: Vishnu Parmar Sprue Safety Products Ltd. Artwork Information Ensure that you are printing / manufacturing from the original artwork file and not a preview CONFIDENTIAL: The information provided in this document is proprietary to Sprue Safety Products Ltd and as such should only be used/shared for the exclusive manufacture of those products specified. Title/Description: User Manual Material: 60GSM Wood Free Paper Used On / Used For: W2-CO-10X Size: W -

  • FireAngel W2-CO-10X, 2 Technical Support: 0800 141 2561 / UK Textphone users: 18001 0800 141 2561 / EIRE dial 1-800 523171 Email: [email protected] / Web: www.fireangel.co.uk Sprue Safety Products Ltd. Vanguard Centre, Coventry CV4 7EZ UK A Sprue Brand W2 module contained within product independently tested to RF standard ETSI EN 300 220-2 V2.3.2 (2010-02) by TRaC Global Ltd. EN 50291-1:2010 EN 50291-2:2010 KM 551504 GN3231R3 W2-CO-10X Carbon Monoxide Alarm

  • FireAngel W2-CO-10X, 3 Features . . . . . . . . . . . . . . 4 Positioning . . . . . . . . . . . . 4 Installation. . . . . . . . . . . . .6 Wireless Interlink . . . . . . . . .7 Alarm Test . . . . . . . . . . . . . 8 Sleep Easy TM . . . . . . . . . . . .9 What to do in the Event of an Alarm . . . . . . . . .9 Note: This user manual is also available in large text and other formats. Please email: [email protected] or call 0800 141 2561 for further information. CONTENTS Carbon Monoxide: How it Can Affect You and Your Family . 9 Product Indicators.

  • FireAngel W2-CO-10X, 4 FEATURES • Wi-Safe 2 technology, enabling wireless interlinking between other Wi-Safe 2 alarms. • An advanced electrochemical sensor designed to accurately measure levels of carbon monoxide (CO) providing an early warning of toxic CO levels in your home. • Detects carbon monoxide continuously. • Resistant to false alarms caused by normal household contaminants. • Sounds a loud 85dB alarm (3 m) to alert you in case of an emergency. • Test/Silence button. • Regular self-check to ensure alarm is

  • FireAngel W2-CO-10X, 5 far from the cooking appliances as possible and near to where the person sleeps. • If the appliance is in a room not normally used (for example a boiler room), the alarm should be put just outside the room so that it may be heard more easily. WHERE IN THE ROOM SHOULD I PLACE THE ALARM? For alarms located in the same room as a fuel-burning appliance (for both wall and ceiling mounted alarms) the following applies: • The alarm should be at a horizontal distance of between 1 m and 3 m from the potential source. • If there is a partition in a room, the alarm should be located on the same side of the partition as the potential source. • Carbon monoxide alarms in room

  • 6 INSTALLATION DO: Ensure this alarm is installed by a competent person who feels able to install it according to the instructions. DO NOT: Tamper with the alarm, for risk of electric shock or malfunction. To mount on a wall or ceiling: Please ensure that you use the screws provided, as they were chosen specifically for use with this product. Drill holes into the wall. Insert the plastic w

  • FireAngel W2-CO-10X, 7 WIRELESS INTERLINK The W2-CO-10X is designed to be wirelessly interlinked with up to 50 products within the Wi-Safe 2 product range. The W2-CO-10X is not designed to communicate with wireless alarms from other ranges or manufacturers. W2-CO-10X alarms need to be ‘learned- in’ or interlinked in order to communicate with each other. If one alarm activates, all other interlinked alarms will also sound. = Wireless Interlink Wi-Safe 2 enables wireless communication with any other product with Wi-Safe 2 technology inside. A wireless transceiver inside every alarm communicates with others by continuously sending and receiving wireless signals otherwise known as a ‘m

  • FireAngel W2-CO-10X, 8 The red LED on Alarm 2 will flash to indicate that it has been ‘learned-in’ successfully. If the test button is not pressed quickly enough, the ‘learn-in’ process will fail. If this happens, repeat the process. To complete the installation fit Alarm 2 into position. When ‘learning-in’ additional alarms, any alarm already in the network, can be used as ‘Alarm 1’. This means that you can ‘learn-in’ the additional alarm to any alarm already in the network. It will then become part of the whole network. You do not

  • FireAngel W2-CO-10X, 9 SLEEP EASY Low battery warnings often start at night or when it may be inconvenient to replace your alarm. You can silence the audible ‘low battery’ chirp for a period of eight hours by pressing the test button. After this period the audible chirp will start again. This process can be repeated for a maximum of 10 times. Your alarm will still detect CO during this time, however you must replace your alarm within 30 days, as it may have insufficient power to warn you of a real CO leak after this time. WHAT TO DO IN THE EVENT OF AN ALARM WARNING: A loud alarm is a warning that potentially lethal levels of carbon monoxide are present. Never ignore this alarm, f

  • FireAngel W2-CO-10X, 10 has no odour or taste and cannot be seen. Like oxygen, CO enters the body through the lungs during the normal breathing process. It competes with oxygen by replacing it in the red blood cells, thereby reducing the flow of oxygen to the heart, brain and other vital organs. In high concentrations, CO can kill in minutes. Many cases of reported carbon monoxide poisoning indicate that while victims are aware they are not feeling well, they become disorientated and unable to save themselves by either exiting the building or calling for assistance. Exposure d

  • FireAngel W2-CO-10X, 11 COMMON SOURCES OF CO: • Oil and gas boilers • Portable generators • Oil or solid fuel cookers • Gas or paraffin heaters • Barbecues • Clogged chimneys • Wood or gas fireplaces • Cigarette smoke • Gas appliances • Any fossil fuel-burning appliance WARNING: This carbon monoxide alarm is not a combustible gas detector, nor a smoke detector. Please install the proper alarms to detect combustible gases, or smoke. This CO alarm should not be seen as a substitute for the proper installation, use and maintenance of fuel-burning appliances (inclu

  • FireAngel W2-CO-10X, 12 PRODUCT INDICATORS Mode Green LED Red LED Amber LED Chirp Normal Operation Flashes once per minute - - - Alarm - Flashes once every five seconds - Four audible ‘chirps’ repeated Low battery / End of sensor life - - Flashes once per minute Chirps once per minute at the same time as the amber LED flashes Sensor fault - - Double flashes Chirps at a different time to the amber LED flashes IMPORTANT: The selected power pack was chosen to provide power beyond the lifetime of the product, in particular the sensor (

  • FireAngel W2-CO-10X, 13 MAINTENANCE Your CO alarm will alert you to potentially hazardous CO concentrations in your home when maintained properly. Keep the alarm free from dust by gently vacuuming the case with a soft brush attachment as required. To prevent the possibility of contaminating the sensor in your alarm and thus affecting its reliability: • Never use cleaning solutions on your alarm. Simply wipe with a slightly damp cloth. • Do not paint the alarm. • Do not spray aerosols on or near the alarm. • Do not use any solvent based produ

  • 14 user guide. It does not cover events and conditions outside of Sprue Safety Products Ltd’s control, such as Acts of God (fire, severe weather etc.). It does not apply to retail stores, service centres or any distributors or agents. Sprue Safety Products Ltd will not recognise any changes to this warranty by third parties. Sprue Safety Products Ltd shall

Related Products and Documents (Fire Alarms):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Roper KU155OV Use and care manual roper/ku155ov-YNA.pdf 05 Dec 2022 8 0.56 Mb
2 Philips 690853116 Operation & user’s manual philips/690853116-535.pdf 05 Nov 2023 25 4.13 Mb
3 Samsung iPolis SNO-5080R Manual  samsung/ipolis-sno-5080r-21X.pdf 12 Oct 2023 60 11.95 Mb
4 UTICA BOILERS UB95M-200 Installation, operation & maintenance manual utica-boilers/ub95m-200-KZL.pdf 17 Feb 2024 52
5 Renesas Emulation Pod M306H7T3-RPD-E Operation & user’s manual renesas/emulation-pod-m306h7t3-rpd-e-5H9.pdf 29 Jul 2023 90 2.11 Mb
6 Frigidaire FGF354BGDD Factory parts catalog frigidaire/fgf354bgdd-QFR.pdf 16 Apr 2023 14

Similar Resources:

  • Bosch

    FMC-300RW-GSRRD

    (28 pages)
    FMC-300RW-GSRRD FMC-300RW-GSRBU FMC 300RW-GSRYEcs Instalacní príruckada Installationsvejledningde Installationsanleitungen Installation Guidees Guía de instalaciónfr Manuel d’installationhr Upute za instalacijuhu Telepítési útmutatóit Guida di installazionenl Installatiehandleidingpl Instrukcja instalacyjnapt Guia de Instalaçãoro Ghid de instalar …
  • Simplex

    4100U

    (8 pages)
    Features Multi-line expanded content display interface for Simplex® 4100U Series fire alarm control panels, available with the following products: • Fire alarm control panels (stand-alone or networked) including Redundant CPU options (Software Revision 12 or higher is required) • Network Display Units (NDU) (single language supports up to 12,000 poin …
  • Notifier

    NBG-12LX

    (2 pages)
    DN-6726 • 06/13/05 — Page 1 of 2GENERALThe NOTIFIER NBG-12LX is a state-of-the-art, dual-ac-tion (i.e., requires two motions to activate the station) pullstation that includes an addressable interface for anyNOTIFIER intelligent control panel. Because the NBG-12LXis addressable, the control panel can display the exactlocation of the activated manual s …
  • Polon-Alfa

    4000

    (11 pages)
    POLON 4000 INTERACTIVE FIRE DETECTION AND ALARM SYSTEM DUR-4047 WIRELESS RADIO UNIVERSAL SMOKE OPTICAL DETECTOR Installation and Maintenance Manual IK-E315-001E IE Edition …
  • AES

    7707

    (46 pages)
    Part No. 40-7707 Rev. 3a 10/23/2017 AES 7707 RF Subscriber Installation, Operation and Programming Manual AES Corporation 285 Newbury Street Peabody, MA 01960 USA Tel (978) 535-7310 • Fax (978) 535-7313 www.aes-corp.com Copyright © 2017 AES Corp. All Rights Reserved …
  • Bosch

    FMC-420RW-HSRRD

    (28 pages)
    FMC-420RW-HSRRDF.01U.012.780cs Instalační příručkada Installationsvejledningde Installationsanleitungen Installation Guidees Guía de instalaciónfr Guide d'installationhr Instalacijske uputehu Telepítési útmutatóit Guida all'installazionenl Installatiehandleidingpl Instrukcja instalacjipt Guia de instalaçãoro Ghid de instalareru Рук� …

Comments, Questions and Opinions: