Electric Heating Company SlimJim Technical Manual

Electric Heating Company SlimJim Manual Online:

4.85, 2802 votes
Electric Heating Company SlimJim User Manual
Electric Heating Company SlimJim User Guide
Electric Heating Company SlimJim Online Manual

Text of Electric Heating Company SlimJim User Guide:

  • Electric Heating Company SlimJim, Electric Flow Boiler INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: [email protected] or visit our website www.electric-heatingcompany.co.uk

  • Electric Heating Company SlimJim, 3 GB- INTRODUCTION Please read and follow the installation and operating instructions carefully, to ensure the long life and reliable operation of this appliance. The Electric Heating Company may make minor changes when necessary in the appliance that will not be shown in the operating instructions, so long as the main features of the boiler remain the same. All boilers come with a 24 month warranty that covers all defects originating from faulty materials and workmanship in the man

  • Electric Heating Company SlimJim, 4 GB- Vented Systems: • circulation pump, • pump valves, • F & E tank, • magnetic filter, • automatic by-pass, if required. Unvented Systems: • circulation pump, • pump valves, • magnetic filter, • automatic by-pass, if required, • EHC sealed system kit, • Automatic air vent, • Twin Channel Heat Pack, if required. Instructions and Building Regulations This appliance must be fitted in accordance with the following instructions. The Local Building Regulations. The Building Regulations. The Building Standards, (Scotland-consolidated) Regulations. Local water bylaws. British Standards code of practice

  • 5 GB- INSTALLATION 1. General The boiler must be installed by a professional plumber or heating engineer and must be connected to the public low voltage network by a competent person. We recommend this is installed by a 17th Edition certified Electrical Engineer. The Electric Heating Company Ltd will not be held responsi- ble for faulty installations which are per

  • Electric Heating Company SlimJim, 6 GB- INSTALLATION ELECTRIC BOILER INTERNAL LAYOUT Figure 1  [1] - Wateroutlet[flow]  [2] - Wateroutlettemperaturesensor  [3] - Heatingexchanger(6stage)  [4] - Contactor  [5] - Powerboard  [6] - WT3safetytemperaturelimiter 1 2 3 4 5 6 7 8 9 10 11 12  [7] - Coldwaterinlettemperaturesensor  [8] - Controlboard  [9] - Waterinlet[return]  [10] - Pumpandroomthermostatcableentries  [11] - Electricmainsentry  [12] - Frontcontrolpanel Note: The boiler is fitted with a Safety Temperature c

  • Electric Heating Company SlimJim, 7 GB- INSTALLATION 12. System types The ‘Slim Jim’ range of boilers can be used in various system designs. Please refer to The Electric Heating Company for more details on under floor heating requirements. We are able to supply a ‘Slim Jim’ Heat Pack that contains the relevant control valves, cylinder and room thermostats required to configure an ‘S’ plan heating system. The heat pack has all the necessary components that you need to connect the systems controls and plumbing configurations for ‘S’ Plan design. We recommend the use of thermostatic radiator valves on all radiators except in the room that has

  • 9 GB- Boiler Protection The recommended protection for hard wired boilers are as follows: Model No Boiler size Protection EHCSJIM4KW 4kW BOILER 20 AMP Protection EHCSJIM7KW 7kW BOILER 40 AMP Protection EHCSJIM10KW 10kW BOILER 50 AMP Protection EHCSJIM12KW 12kW BOILER 63 AMP Protection EHCSJIM14.4KW 14.4kW BOILER 80 AMP Protection External Controls We recommend the use of the

  • Electric Heating Company SlimJim, 10 GB- ELECTRICAL DOMESTIC ‘MAINS’ CONNECTION: ELECTRICAL CONNECTIONS AND CONTROLS Figure 4 Slim Jim Boiler howstheelectrical‘mains’connectiontoUKdo- mesticnetwork L N Figure 5 showstheboilerconnectionsofthesinglephase system  LNE - Neutral,Earth&Phaseconductors  [6] - TemperatureLimiter  [15] - Additionalconductor

  • 11 GB- PROGRAMMER ROOM THERMOSTAT CALL FOR HEAT BOILER CONNECTIONS Note: Mains connection to 3 Amp fused spur PROGRAMMER ROOM THERMOSTAT CALL FOR HEAT BOILER CONNECTIONS NOTE! ‘Call for heat’ ‘RP’ connections...are Volt free Contacts EXTERNAL CONTROL WIRING Figure 6 Figure 7

  • Electric Heating Company SlimJim, 12 GB- 8 JP4 JP3 Pump mode CTRL enab. CTRL N L Pump RP CONNECTION OF EXTERNAL APPLIANCES Figure 8 shows the Control Board (Controller) to which a number of external appliances can be connected. The board can be set for different working modes of operation. In addition the board provides signal indicators for ‘start up’ and diagnostic monitoring of the correct boiler operation. Figure 8 KeytoFigure8–MSK7.1Controller  [1] - “RP“- RoomThermostatcontactsentries  [2] - “PEAKOFF”-23O-24OV

  • Electric Heating Company SlimJim, 13 GB- CONNECTION OF EXTERNAL APPLIANCES 1. Room Thermostat A voltage free Room Thermostat should be connected to the boiler through the ‘RP’ [1] connections. When the connections are closed, a ‘call for heat’ has been requested to the boiler. Once Room Thermostat temperature setting has been reached the ‘call for heat’ will cease and the boiler will switch the heating off. The [4] led indicator on the Controller Board illuminates when the Room Thermostat ‘RP’ connections are closed. 2. Pump. The circulation pump shouldbe connected to connection block [3], The pump is connected to the mains input voltage via a fuse (1A delayed 230V) that is

  • Electric Heating Company SlimJim, 14 GB- Failure signals 1. Flow failure - when the boiler is on (switch [4] in position “1”) the indicator flashes at 1 second intervals. 2. Inner temperature sensor failure - the indicator flashes at much more frequent intervals than described in ‘1’ above. It will also indicate a failure when the boiler is off (switch [4] in position “0”). Fig.10 Dependencebetweenmediumtemperatureandtheoutdoor temperature(at20°Croomtemperature) PREVENTIVE MAINTAINANCE We recommend the following routine maintenance in order to assure faultless operation: 1. Do not drain the water from central heating system after the he

  • Electric Heating Company SlimJim, 15 GB- FAULT FINDING Symptom Reason Procedure The [2] indicator does not illumi- nate No mains power supply Check out the electric mains parameters and fuses The inner safety temperature limiter has locked out Call competent service engineer The [3] indicator flashes Inner temperature sensor failure Call competent service engineer The [3] indicator flashes at 1 sec- ond intervals (switch [4] in posi- tion “1”) Pump off Call competent service engineer - check out the fuse on the control board No flow Check out efficiency of the ce

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Mitsubishi EW230U-ST Specifications mitsubishi/ew230u-st-OK1.pdf 27 May 2023 2
2 Boss BL-1 Owner's manual boss/bl-1-E8O.pdf 16 Sep 2023 30 1.17 Mb
3 Lexmark Z55 Operation & user’s manual lexmark/z55-95B.pdf 13 Nov 2023 27
4 MSI K8N Neo-V2 Instruction manual msi/k8n-neo-v2-9FZ.pdf 30 Jan 2024 90
5 Intermec Trakker Antares 243X Operation & user’s manual intermec/trakker-antares-243x-RB1.pdf 18 Nov 2022 114
6 HP LJ3100 Replacement and removal manual hp/lj3100-43U.pdf 20 Mar 2024 11

Similar Resources:

  • Sime

    BRAVA DGT HE 25

    (12 pages)
    BRAVA DGT HE25 - 30 - 35199838USER INSTRUCTIONSENSURE THAT THESE INSTRUCTIONS ARE LEFT FOR THE USER AFTER COMPLETION OF THE BENCHMARK SECTIONPLEASE READ THE IMPORTANT NOTICE WITHIN THIS GUIDE REGARDING YOUR BOILER WARRANTYUKCod. 6316190 - 03/2013 …
  • Ideal Boilers

    Optia HE 9

    (48 pages)
    9, 12, 15, 18Wall mounted, balanced flue, fanned gas boilerOptia HE High Efficiency BoilersInstallation & Servicing InstructionsSee reverse for Optia HE Users GuideManufactured exclusively for Wolseley UK by Ideal BoilersFor details of document amendments, refer to page 3January 2008 UIN 201 962 A06201962-6.pmd 19/02/2008, 15:101 …
  • Viessmann

    Vitoflame 100

    (56 pages)
    VIESMANNService instructionsfor contractorsVitoflame 100Type VGIIIPressure‐jet gas burnerfor Vitoplex 100, 200 and 300Rated output 80 to 225 kWfor Vitorond 200Rated output 125 to 195 kWFor applicability, see the last pageVITOFLAME 1005692 678 GB 11/2006 Please keep safe. …
  • clage

    Zip Hydroboil Series

    (24 pages)
    v1.0 05.19315352 325352 340352804545DEde > 2en > 13Zip Hydroboil®Zip Hydroboil®Gebrauchs- und Montageanleitung Operating and installation instructions …
  • Baxi

    Roca LIDIA 20 GT EM

    (3 pages)
    LIDIA GT EMGrupos TérmicosInstrucciones de Funcionamiento,Limpieza y Mantenimientopara el USUARIOGBPIDFGroupes ThermiquesInstructions Fonctionnement,de Nettoyage et de Maintenancepour l’UTILISATEUR EHeating UnitsOperating, Cleaning,and Maintenance Instructionsfor the USERHeizkesselBetrieb-, Reinigungs- undWartungsanleitungfür den BENUTZERGruppi TermiciI …
  • Laars

    NEOTHERM NTH

    (64 pages)
    Installation and Operation Instructions Document 1218FH2335500FWARNINGIf the information in this manual is notfollowed exactly, a fire or explosion mayresult causing property damage, personalinjury or loss of life.Do not store or use gasoline or otherflammable vapors and liquids in the vicinityof this or any other appliance.WHAT TO DO IF YOU SMELL GAS• Do …

Comments, Questions and Opinions: