Manualios.com

Dickinson Newport P1200000-NEW-P12000 Installation And Operating Manual

  • Newport P1200000-NEW-P12000 Indoor Fireplace
  • makL6ypdEBzJc
  • Installation And Operating Manual
  • PDF / Adobe Acrobat Reader
  • 11

Dickinson Newport P1200000-NEW-P12000 Manual Online:

3.55, 1924 votes
Dickinson Newport P1200000-NEW-P12000 User Manual
Dickinson Newport P1200000-NEW-P12000 User Guide
Dickinson Newport P1200000-NEW-P12000 Online Manual

Text of Dickinson Newport P1200000-NEW-P12000 User Guide:

  • dickinson since 1932 MODEL 00-NEW-P12000 INSTALLATION AND OPERATING MANUAL Manufactured by: Dickinson Marine (1997) Ltd, 407-204 Cayer Street, Coquitlam, British Columbia, Canada V3K 5B1 www.ahoycaptain.com Quality and service is remembered long after price is forgotten 1

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 2 PACKING LIST PART NO 00-NEW-P1200 - NEWPORT PROPANE FIREPLACE/HEATER Including - 28” approx (70cm) Direct Vent Pipe Kit (approx.) 1.5 ins (37.5mm) Inner S/S Pipe 2.5 ins (62.5mm) Outer S/S Pipe 4 spacer springs installed inside pipe - S/S Double - Direct Vent - Flue Cap - Sealing Gasket - Inner Dress Ring - mounting screws - S/S Back Mounting Plate (attached to heater) OPTIONAL ACCESSORIES AVAILABLE PART NO 19-000 - 28 ins (70cm) Direct Vent Pipe Extension Kit (approx.)including coupling 19-010 - 120VAC to 12VDC Shore Power Converter.

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 3 SPECIFICATIONS – P12000 Model - NEWPORT PROPANE FIREPLACE/HEATER Type - DIRECT VENT Ignition - MANUAL Fuel - LPG (Propane/Butane) Low Pressure – 11 ins water column Fuel Consumption - 1lb bottle - Low 5.5 hrs : High 3.9 hrs 20lb bottle - Low 110 hrs : High 78 hrs Fuel Line - 3/8 ins copper or approved hose - 3/8 ins flare fitting Heat Rating - Fan Off - Low 4000BTU/h - 920kcal/h ( 1080w/h) High 5500BTU/h - 1289

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com NEWPORT PROPANE FIREPLACE MODEL NO. 00-NEW-P12000 INDEX Page INSTALLATION 1 Location…………………………………………. 1 Mounting……………………………………….. 2 Direct Vent Thru Fitting and Cap…………… 2 Installation Diagram………………………….. 2 Installation Procedure………………………… 3 Gas Supply Hook-Up…………………………. 4 Typical ; LPG On-Board System - Diagram... 4 Blower Fan - Electrical………………………… 5 OPERATION 5 Lighting…………

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 5 LOCATE the heater where it will maximize the radiant heating capability. The NEWPORT PROPANE HEATER is equipped with a manually operated blower fan that will blow hot air from the top of the heater down onto the floor. This increases heating efficiency and provides good circulation of hot air. LOCATE so that the front and sides of the heater are at least 3 ins (75 mm) from combustible surfaces. LOCATE to provide easy installation of the flue and external flue cap. The mounting flange of the thru fitting and cap requires an area of at least 6&q

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 6 Additional 28" (70cm) lengths of pipe are sold as an option ( Part No. 19-000). This pipe can be cut with a fine hacksaw blade to the required length. A coupling fitting is provided with the optional length. DIRECT VENT THRU-FITTING AND CAP o 6" (15cm) 3" (75mm) INSTALLATION PROCEDURE Sealing Gasket Deck Flange Dress Ring 6 Mounting Screws Flexible Double Pipe Screw Pilot Holes Deck 4 Mount

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com holes in the flexible pipe and install sheet metal screws to secure. DIRECT VENT FITTING GAS SUPPLY AND HOOK-UP THE HEATER OPERATES ONLY ON LOW PRESSURE LPG GAS (11"w/c) If there is a propane fuel system installed a separate supply line must be supplied for the heater. This line must be equipped with a low-pressure regulator (Dickinson Part No. 19-151) Deck Outside Air for Combustion Combustion Gases Connect to the 3/8" flare connector of the heater with copper or an approved hose. During this procedu

  • www.ahoycaptain.com 8 TYPICAL LPG ON-BOARD SYSTEM From Gas Safety Detector ELECTRICAL 5-20 lb Tank VENTED ENCLOSURE Min. 1/2" I.D. Vent Flapper Valve Solenoid Valve Secured Bottle Pressure Gauge COOK STOVE SEA-B-QUE BARBEQUE NEWPORT HEATER Pressure Regulators Manual Shut-Off The blower

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 9 OPERATION LIGHTING TEST ALL GAS LINES AND CONNECTIONS FOR LEAKS WITH SOAP SOLUTION. NOTE : ONLY ON FIRST LIGHTING the lubricating oil on the stainless steel pipe will produce smoke and burn off. THIS IS NORMAL. We suggest that windows and hatches be opened. Smoke from the inside pipe will be emitted outside, through the flue cap. 1) Open heater door 2) Turn GAS knob to LOW 3) Depress knob and light burner manually. 4) Keep knob depressed for 15/20 seconds. CLOSE HEATER DOOR. Release knob and flame will remain lit. (Leaving the heater door open after ig

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 10 THE INSTALLATION OF A LPG DETECTOR IS RECOMMENDED FOR ALL LPG APPLIANCES. PROBLEM? SOLUTION! No gas to burner on lighting Check that knob is exactly at 9 o'clock when depressed Fire does not stay lit when Depress knob, light burner and CLOSE knob is released COMBUSTION CHAMBER DOOR before releasing knob Check that the door is seal is good Any other Contact dickinson 1 800 659 9768 Email - [email protected]

  • Dickinson Newport P1200000-NEW-P12000, www.ahoycaptain.com 11 LIMITED WARRANTY WARRANTY PROVISIONS : dickinson warrants this product to be free of defects in workmanship and materials for a period of one year. This warranty is limited to claims submitted in writing within a one-year period following the date of purchase. If any part of your new product fails because of a manufacturing defect within the warranty period dickinson offers to replace said parts free of charge provided, however, that such parts have not been improperly repaired, altered or tampered with or subjected to misuse, abuse or exposed to corrosive conditions. This warranty however, is limited to certain exclusions, time limits and excepti

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Avermedia 500 Operation & user’s manual avermedia/500-KZ1.pdf 02 Jul 2022 37 2.15 Mb
2 Yamaha CA-610 Service manual yamaha/ca-610-83S.pdf 18 Oct 2023 25
3 Fanimation FP7000 Specification sheet fanimation/fp7000-M2T.pdf 26 Aug 2023 2 0.37 Mb
4 Aquabilt A-2000 Set-up instructions and operation manual aquabilt/a-2000-ATK.pdf 13 Jul 2023 6
5 Samsung SMH1611B Operation & user’s manual samsung/smh1611b-745.pdf 11 Oct 2022 48 5.38 Mb
6 Memorex MB002 Operation & user’s manual memorex/mb002-447.pdf 22 Dec 2023 16

Similar Resources:

  • Regency Fireplace Products

    P33-NG4

    (52 pages)
    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-520aMODELS: P33-NG4 Natural Gas P33-LP4 PropaneP33-4 Zero ClearanceDirect Vent Gas Fireplace03/05/08Owners & Installation ManualWARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property d …
  • Valor

    762

    (60 pages)
    5136065/06Model 762Inset live fuel effect gas fire for assembly with;Blakely fascia© GDC Group Ltd. 2013Please keep me in a safe place for future use.We trust that this guide gives sufficient details to enable this appliance to beinstalled, operated and maintained satisfactorily. However, if further information isrequired, our Valor Technical Helpline will …
  • Euroheat

    WIKING MIRO Range

    (14 pages)
    E & OE Instructions Part number IN1274 Ed A1© EUROHEAT DISTRIBUTORS (H.B.S) LTD. Jan 2013Document Part Number IN1274Operating and MaintenanceInstructions ForWIKING MIRO RangeThe Above are Suitable For Use In Smoke Control AreasWood ModelsThis Manual Must Always Be Available To The Stove OperatorSerial NumberPart No.Model NameThis manual must be used …
  • Astria

    MontebelloSTTYN

    (62 pages)
    Installation and Operation InstructionsAstriaTM Montebello See Through Direct Vent Gas Fireplaces with PowerventP/N 900358-01 Rev. NC 12/2014Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900358-03.PFS®USCModelsMontebelloSTTYNP900358-01INSTALLER: Leave this manual with the appliance.CONSUMER: Retain this manu …
  • Dimplex

    V1525BT

    (23 pages)
    7208630100R01PRACTICAL USER’S GUIDEFOR THE IN-STUD FIREPLACE MODEL NUMBER:V1525BTV1525RTValued Customer,We are pleased that you have chosen to purchase anelectric fireplace manufactured by Dimplex North AmericaLimited.Over the years, valuable memories will occur around thewarmth and comfort of your hearth. Thank you for allowingour product to be the backd …
  • Kennedy

    Kennedy II 42 / JR-42S

    (24 pages)
    Page 1(OHFWULF)LUHSODFHWith Mounting Bracket Kit for Adjustable Installation5($'6$9(7+(6(,16758&7,216Carefully read and review before assembling, installing, operating, or maintaining this product. Observe all safety instructions and information.)$,/85(72)2//2::$51,1*623(5$7,21$/,16758&7,216&217$,1(& …

Comments, Questions and Opinions: