Butterfly Energy Systems BESM-24AO23 Installation Manual
|
Butterfly Energy Systems BESM-24AO23, Thank you for choosing BuƩerfl y Energy Systems, please review installaƟon guide before installaƟon and retain for future reference. BuƩerfly Energy Systems Air Intelligence Series InstallaƟon Guide (For Outdoor MulƟ-Head Systems) BESM-24AO23
1 2 3 4 4 5 7 7 8 8 9 Technical Data Electrical Connections Installing The Outdoor Unit Maintenance Installation Dimension Diagram Check After Installation Bleeding Conformity And Range The Instructions Before Use Name of Parts Outdoor Unit Working Temperature Range GENERAL INSTALLER INFORMATION CONTENTS 1 In line with the company’s policy of continual product improvement, the aesthetic and di
Butterfly Energy Systems BESM-24AO23, 2 GENERA L INFORMATION fire or electrical shock when operating an electrical appliance including the following: 2.This appliance is hot when in use. To avoid burns,do not touch bare skin on hot surfaces. Keep combustible materials such as clothing, pillows, bedding, and curtains away from the front of the appliance. And keep objects at least 1 meter away from the sides of the appliance. 3.This appliance is cold when in use. Be mindful of the coldair blowing from the front. Ar range house
Butterfly Energy Systems BESM-24AO23, Note: the above figures are only intended to be a simple diagram of the appliance and may not correspond to the appearance of the units that have been purchased. OUTDOOR UNIT No. Description 1 Air outlet grille 2 Valve The temperature of refrigerant circuit will be high,please keep the interconnection cable away from the copper tube. Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case. Volatile liquids such as thinner or gasoline will cause damage to the appearance of air conditioner. (On
Butterfly Energy Systems BESM-24AO23, Maximum cooling Minimum cooling Maximum heating Minimum heating Outdoor side DB/WB( ) 48/- -5/- 27/- -15/- OUTDOOR UNIT WORKING TEMPERATURE RANGE GENERAL INFORMATION 4 TECHNICAL DATA GENERA L INFORMATION P L A B H Minimum power cable section 40 4.0 g mm mm mm mm mm L P H A B Fuse or air switch 2200 890 362 700 560 368 MODE BESM-24AO23 208/230V/1~60Hz mm 2 Refrigerant gas(R410A) Electrical data Electricity supply Size and clearance c
Butterfly Energy Systems BESM-24AO23, 2 . 3. 4. 5. Remove the cable clamp, connect the connection cable and power cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit terminal of line bank. 1. Remove the handle at the right side plate of the outdoor unit (ten screw). Wiring should meet that of indoor unit. Fix power connection wire by wire clamp. Ensure wire has been fixed well. Install the handle. ELECTRICAL CONNECTIONS INSTALLER BESM-24AO23 Wrong wire connection may cause malfunction of some electric components.After fixing cable, ensure that An all-pole discon
Butterfly Energy Systems BESM-24AO23, HANDLING USER After having removed the packaging, check that the contents are intact and complete. The outdoor unit must always be kept upright. Handling must be done by suitably equipped qualified technical personnel using equipment that is for suitable the weight of the appliance . 6
Butterfly Energy Systems BESM-24AO23, Vacuum pump INSTALLER Humid air left inside the refrigerant circuit can cause com- pressor malfunction. After having connected the indoor and outdoor units, bleed the air and humidity from the refrigerant circuit using a vacuum pump. (1) Unscrew and remove the caps from the 2-way and 3- way valves. (2) Unscrew and remove the cap from the service valve. (3) Connect the vacuum pump hose to the service valve. (4) Operate the vacuum pump for 10-15 minutes until an absolute vacuum of 10 mm Hg has been reached. (5) With the vacuum pump still in operation, close
Butterfly Energy Systems BESM-24AO23, MAINTENANCE INSTALLER INSTALLATION DIMENSION DIAGRAM The installation must be done by trained and qualified service personnel with reliability according to this manual. This is just the schematic plan, please refer to the actual product. BESM-24AO23 30cm (Air inlet side) or above 50cm or above Spacetothewall 200cm (Air outlet side) or above 30cm Space to the cover or above or more Space to the cover 50cm INSTALLER Use suitable instruments for the refrigerant R410A. Do not use any other refrigerant than R410A. Do not use
Butterfly Energy Systems BESM-24AO23, INSTALLER CHECK AFTER INSTALLATION Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit sufficient? May cause condensation and water dropping Is the drainage smooth? May cause condensation and water dropping Does the power supply voltage accord with the rated voltage specified on the nameplate? The unit may bread down or the components may be burned out Are the lines and pipelines correctly installed? The unit may bread down or the components may be burned o
Friedrich PE07K Air Conditioner Service manual
PE07K |
Toshiba RAV-SM1403DT-A Air Conditioner Installation manual
RAV-SM1403DT-A |
Haier AD482MPERA Air Conditioner Operation & installation manual
AD482MPERA |
Samsung SC05ZZ8 Air Conditioner Owner's instructions manual
SC05ZZ8 |
Trotec PT 6500 S Air Conditioner Operating manual
PT 6500 S |
Carrier 58SMA Air Conditioner Operating instructions manual
58SMA |
Pioneer YN018GMFI16M2D Air Conditioner Service manual
YN018GMFI16M2D |
Haier HW-09CH03 Air Conditioner Operation & user’s manual
HW-09CH03 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Homelite | UT46510 | Troubleshooting tips | homelite/ut46510-2U9.pdf | 14 Sep 2022 | 2 | 3.64 Mb |
2 | RCA | L32WD22 | Features and benefits | rca/l32wd22-362.pdf | 09 Apr 2023 | 2 | 0.31 Mb |
3 | Panasonic | CS-NE9NKE | Service manual | panasonic/cs-ne9nke-OPQ.pdf | 11 Oct 2023 | 117 | |
4 | APPA | 36II | Instruction manual | appa/36ii-3WG.pdf | 26 Oct 2022 | 24 | |
5 | CHIEF | TA500 | Installation instructions manual | chief/ta500-9L9.pdf | 09 Sep 2022 | 12 | |
6 | Sony | Walkman ICF-CD814 | Specifications | sony/walkman-icf-cd814-B9Q.pdf | 19 Jan 2024 | 2 | 3.24 Mb |
GE
GEAppliances.comE"0Safety Instructions ............. 2, 3Operating InstructionsControls ........................... 4-6Care and CleaningAir Filter .............................. 6Outdoor Coils ......................... 6Installation Instructions ...... 7-12Troubleshooting Tips ............ 13Normal Operating Sounds ............ 13Consumer SupportConsume …
AHH24DSH1(32 pages) |
Midea
Revision A: 1403100001, Content updated. Model Numbers: MEHS-09NiH2/MCHS-09NiH2 MEHS-09NIH1/ MCHS-09NiH1 …
MEHS-09NIH2(61 pages) |
Hitachi
NO. 0489ESPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENTROOM AIR CONDITIONERINDOOR UNITAPRIL 2011 Refrigeration & Air-Conditioning DivisionSERVICE MANUALPMREFER TO THE FOUNDATION MANUALTECHNICAL INFORMATIONFOR SERVICE PERSONNEL ONLY(W)(A)(kW)(B.T.U./h)(W)(A)(kW)(B.T.U./h)WHD(kg)DC INVERTER (WALL TYPE)TYPE MODEL …
RAK-18NH6AS(72 pages) |
Haier
ROOM AIR CONDITIONERUse & Care GuideCLIMATISEUR DE PIÈCEGuide d’utilisation et d’entretienModel: For questions about features, operation/performance, parts, accessories or service call: 1-877-337-3639Au Canada, pour assistance, installation ou service,composez le : 1-877-337-3639NOTE: Your model may differ from the one shown.CWH12A CWH18A CWH24A
…
CWH12A(43 pages) |
Toshiba
R410AFILE NO. A05-001PRINTED IN JAPAN, Apr.,2005 ToMoSERVICE MANUALSPLIT TYPE<NEW DIGITAL INVERTER>OUTDOOR UNITRAV-SM561AT-ERAV-SM801AT-ERAV-SM1101AT-ERAV-SM1401AT-EINDOOR UNITThis Service Manual describes contents of the new outdoor unit.For the indoor unit, refer to the Service Manual with FILE NO. A03-003F.
…
RAV-SM561AT-E(77 pages) |
TCL
Air Conditioner Service Manual Inverter air conditioner Service Manual Models TAC-09CHSA/XP TAC-12CHSA/XP CONTENTS 1. Important Notice2. Technical Specifications 3. Product Dimensions 4. Refrigeration cycle diagram5. Operation details 6. Wiring diagram 7. Expl …
TAC-09CHSA/XP(40 pages) |
Siemens Switch SCALANCE XM-400Switch Configuration manual (Siemens SCALANCE XM-400) SCALANCE XM-400, 832 |
Nobels Music Equipment LOOP-MASTERNobels Music Equipment LOOP-MASTER Operation & user’s manual LOOP-MASTER, 2 |
Philips Coffee Maker HD7567/20User Guide: Philips HD7567/20 (8DN3R7, Upd.Sat 09.2023) HD7567/20, 3 |
Ariens Snow Blower 924124-ST926DLE, 924125-ST1152Ariens Snow Blower Owner's/operator's manual (File: ariens-92-snow-blower-32, Tue 10.2023) 924124-ST926DLE, 924125-ST1152, 32 |
Samsung Multiplexer SDM-090#P75Z67: SDM-090 Multiplexer Operation & user’s manual SDM-090, 39 |
Kiddicare Baby & Toddler Furniture Dream CotKiddicare Dream Cot Guide (Doc Type: Baby & Toddler Furniture Instruction manual) Dream Cot, 3 |
AEG Heater Spirit 1002AEG Spirit 1002 Heater Operating and installation instructions Spirit 1002, 24 |
Axis Security Camera Q1775-EAxis Q1775-E Security Camera Installation manual Q1775-E, 112 |
Philips Bottle Warmer SCF147Bottle Warmer PDF Specification sheet SCF147, 2 |
Maytag Washer MHWE900VW - Performance Series Front Load Steam WasherPDF Manual (@352JE9), Maytag MHWE900VW - Performance Series Front Load Steam Washer Washer (Sat 01.2024) MHWE900VW - Performance Series Front Load Steam Washer, 56 |
HoMedics Clock Radio SOUNDSPA SUNRISE SS-5500HoMedics SOUNDSPA SUNRISE SS-5500 User Manual (Doc Type: Clock Radio Instruction manual) SOUNDSPA SUNRISE SS-5500, 12 |
McCulloch Chainsaw Cabrio 380McCulloch Product User Manual: Cabrio 380 PDF Operator's manual - ADSU56 Cabrio 380, 86 |