Cooline VWL series Installation, Operation & Maintenance Manual
|
Contents Page Model decoding ........................................................................................................................................ 2 Options ..................................................................................................................................................... 2 General information .................................................
Cooline VWL series, OPTIONS ELECTRICAL HEATERS The heating element is made of tubular finned sheath coil of the highest grade resistance wire precisely centered in a 1/2" dia. Copper plated steel sheath and insulated from the sheath by magnesium oxide powder. Through the application of mechanical force, the powder is packed to a rock like density, insuring rapid heat dissipation from the resistance coil to the sheath section at each end of the element is unheated to remove source of heat from the terminals. The surface area exposed to the air is increased by the application of 1-1/4" OD fins. The fin is made of steel
Cooline VWL series, GENERAL INFORMATION Thank you for your purchase of this equipment from the COOLINE Air Conditioners. We trust that this unit will provide you with the proper Cooling/Heating requirements for years to come. This unit has been tested to the extremes in terms of working conditions and successfully passed all the requirements of quality, safety and performance. However, we would suggest that you read carefully this manual before you proceed with the installation and operation of this equipment and follow the instructions for a safe, trouble free operation. WARRANTY TERMS All of the VWL series of indoor vertical fan coil (concealed) units are covered by the standard warranty terms again
Cooline VWL series, INSTALLATION PROCEDURES A. Location of units The Indoor FCU should be ideally located in a floor or hung to a wall that is near to the conditioned area where the access to the chilled water piping connection is easy. Position the FCU in a way to avoid obstruction to return airflow, supply air, electrical cable connections, condensate drain pipe and chilled water piping. B. Site Preparation The site for the FCU installation should be free from any obstacle that can be hazardous to the installation personnel and/or damaging to the unit. Properly identify all existing building utili
D. Piping connection MODEL NUMBER SWEAT CONNECTION WATER INLET WATER OUTLET 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" VWL 03 VWL 04 VWL 06 VWL 08 VWL 10 E. Condensate Drain connection - Use PVC Class 3 material for the condensate drain piping (3/4 " ). - Provide a " P " trap immediate
Cooline VWL series, UNIT DIMENSIONS MODEL ABCD VWL03 597 (23.5) 559 (22) 457 (18) 406 (16) 1 1 VWL04 851 (33.5) 813 (32) 711 (28) 660 (26) 1 2 VWL06 1105 (43.5) 1067 (42) 965 (38) 914 (36) 1 2 VWL08 1511 (59.5) 1473 (58) 1372 (54) 1321 (52) 2 4 VWL10 1715 (67.5) 1676 (66) 1575 (62) 1524 (60) 2 4 DIMENSIONS COIL CONNECTION DIMENSIONS INLET OUTLET NOTE: All dimensions are in mm (dimensions in brackets are in inches). CHILLED WATER & HOT WATERCHILLED WATER No. OF MOTORS No. OF BLOWERS 1. Mounting holes (4 No.) 2. Ai
TYPICAL SCHEMATIC WIRING DIAGRAM 7 HEAT/COOL MODELS - ELECTRIC HEATER 50 FREQUENCY APPLICABLE VWL 08 VWL 10 HIGH HIGH COM COM MED MED LOW LOW 50 (YEL) VWL 06 VWL 04 HIGH COM HIGH COM (WHT) VWL 03 MODEL HIGH COM (BLK) MED MED LOW 50 LOW 50 (ORN) MED (BLU) LOW 50 (RED) IN HZ FACTORY WIRED MOTOR LEADS LEGEND ATB AUXILIARY TERMINAL BLOCK COM COMMON CR CONTR
Cooline VWL series, TYPICAL SCHEMATIC WIRING DIAGRAM 8 HEAT/COOL MODELS - HOT WATER LEGEND ATB AUXILIARY TERMINAL BLOCK COM COMMON CR CONTROL RELAY EV ELECTRIC VALVE (COOLING) EV1 ELECTRIC VALVE (HEATING) FM FAN MOTOR GND LUG GROUND HVTB HIGH VOLTAGE TERMINAL BLOCK L/L1 LINE OR LINE 1 L2/N LINE 2 OR NEUTRAL _ _ _ FIELD WIRING FACTORY WIRING NOTES 1. POWER SUPPLY, 220/240V-1PH-50Hz. 2. USE COPPER CONDUCTOR WIRES ONLY. 3. IF EV1 IS FACTORY INSTALLED, PLEASE READ BROKEN LINES AS CONTINUOUS LINES. 4. FM2 NOT REQUIRED FOR SINGLE MOTOR AHU. IF FM2 IS FACTORY INSTALLED, PLEASE READ BROKEN LINES
Cooline VWL series, VALVE PACKAGES VALVE PACKAGE 3-D (COOL ONLY) VALVE PACKAGE 4-D (COOL & HEAT) 1 2 3 Two gate shut off valves One balancing valve One 3-way motor valve 1 2 3 Four gate shut off valves Two balancing valves Two 3-way motor valves PARTS LIST MODEL NUMBER VWL03 VWL04 VWL06 VWL08 VWL10 BLOWER WHEEL 800-707-58 800-707-57 & 58 800-707-57 & 58 800-707-57 & 58 800-707-57 & 58 BLOWER MOTOR 800-827-17 800-827-08 800-827-11 800-827-08 800-827-11 RETURN AIR FILTER 800-248-20 800-248-22 800-248-23 800-248-25 800-248-26 VALVE PACKAGE (3D), COOL ONLY 700-361-62 700-361-62 700-361-62 700-361-62 700-361-62
Cooline VWL series, THERMOSTAT OPERATION & SPECIFICATION DATA OFF mode switch position COOL mode switch position FAN mode switch position HEAT mode switch position Temperature set button (increasing) Temperature set button (decreasing) LOW fan speed switch position MEDIUM fan speed switch position HIGH fan speed switch position FUNCTIONSYMBOL OPERATING INSTRUCTIONS COOLING MODE - Position the switch S1 to COOL mode function. - Set desired temperature setting by pressing the (+) or (-) button to increase or decrease the set value displayed on the LC
Cooline VWL series, PRODUCT DATA Part Number : 800-646-20 Switches : Fan speed high/med/low Heat/Fan/Cool/Off Outputs : Heat Cool Fan speed high/med/low Inputs : Remote sensor (optional) TECHNICAL DATA Operating voltage : 230V + 10%; AC 50/60 Hz Operating ambient : 0 0 C to 40 0 C Temperature range : 5 0 C to 30 0 C Selectivity of set value : 0.5K Display range (actual value) : 0... + 40 0 C Selectivity of actual value : 0.1K Hysteresis : ~0.5K Switching current at 250 VAC : 3 (2)A Maximum fan current : 6 (3)A Sensor system : NTC (in housing) Optional Remote Sensor 193720 Switches : Heat/Off/Cool/Fan 3 Fan Speed Indicator lamps :
Cooline VWL series, MAINTENANCE Warning: Before you attend to any routine maintenance, make sure that the electrical power is disconnected. - Avoid spilling any liquid on the thermostat - Always allow for 1 to 2 minutes before activating different commands. COIL CLEANING Coil may be cleaned by removing and brushing between fins with a stiff wire brush. Brushing should be followed by cleaning with vacuum cleaner. The coil may also be cleaned by using a high pressure air, if compressed air source is available. It should be pointed out that if air filters are used and periodically cleaned, the coils w
Cooline PT036 Air Conditioner Installation, operation & maintenance manual
PT036 |
Bard WL4822 Air Conditioner Installation instructions manual
WL4822 |
Pioneer KJR-12BP-F Air Conditioner Owner's manual
KJR-12BP-F |
Sanyo KMHS0972 Air Conditioner Brochure & specs
KMHS0972 |
Cooline DWL SERIES Air Conditioner Installation, operation & mainenance manual
DWL SERIES |
Panasonic CS-MKS12NKU Air Conditioner Submittal data
CS-MKS12NKU |
LG LFU480CE Air Conditioner Owner's manual
LFU480CE |
LG A2UN186FA0 Air Conditioner Service manual
A2UN186FA0 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | 3Com | NBX 1105 | Telephone manual | 3com/nbx-1105-5WI.pdf | 05 Feb 2024 | 98 | 0.96 Mb |
2 | Accu-Chek | Softclix | Instructions for use | accu-chek/softclix-78J.pdf | 24 Jul 2022 | 2 | |
3 | AEG | 68001KF-N | Installation and operating instructions manual | aeg/68001kf-n-869.pdf | 05 Feb 2023 | 32 | 0.24 Mb |
4 | Ibiza sound | DJM250BT-MKII | Operation & user’s manual | ibiza-sound/djm250bt-mkii-YW5.pdf | 04 Nov 2023 | 28 | |
5 | RCA | RCR815 - Universal Remote Control | Operation & user’s manual | rca/rcr815-universal-remote-control-3Q5.pdf | 16 Jun 2023 | 25 | 3.86 Mb |
6 | Samsung | ML-1210 | Operation & user’s manual | samsung/ml-1210-8TM.pdf | 29 Jul 2023 | 54 | 4.43 Mb |
HTW
OWNER’S MANUALEVAPORATIVE AIR COOLERENGLSIHALPC./ Industria, 13 l Polígono Industrial El Pedregar 08160 MontmelóBarcelona (Spain)Phone: (0034) 93 390 42 20Fax: (0034) 93 390 42 [email protected] This product is only suitable for well insulated spaces or occasional use. Thanks for choossing our evaporative air cooler. Ple …
ALP(12 pages) |
SCE
B1SAGINAW CONTROL & ENGINEERING • A/C USER MANUAL 1. User Manual ............................................................................................p. 2 2. Legal Regulations ...................................................................................p. 2 3. Safety Instructions ...................................................... …
SCE-AC1870B230V(14 pages) |
Frigidaire
Installation InstructionsFor Heavy DutyPlease read ALL instructions before installing. Two people arerecommended to install this product. Ifa new electrical outletis required, have the outlet installed by a qualified electricianbefore installing unit. See#5 in Preliminary Instructionsfollowing.Preliminary InstructionsDo the following before starting to insta …
FAS156N1A2(8 pages) |
Viessmann
Please file in Service Binder5680 011 - 10 06/2016Viessmann Airfl owPLUSInstallation, Service and Operating Instructionsfor use by heating contractorViessmann AirflowPLUS AH2A seriesHydronic forced air handlerProduct may not be exactly as shownRead and save these instructionsfor future reference.IMPORTANT
…
AirflowPLUS AH2A-213(60 pages) |
Enviro
HP SERIES FAN COILSSupersedes ET115.24-NOM1 (0420)Form ET115.24-NOM1 (0520)INTRODUCTION ENVIRO-TEC fan coils represent a prudent investment which can, with proper installation, operation, and regular maintenance, give trouble-free operation and long service.Your equipment is initially protected under the manufacturer’s standard warranty; however, this warr …
HP Series(34 pages) |
Kenmore
REPAIRPARTSLISTModel No.580.75135501◆ Product Type ◆ Part Number◆ Model Number ◆ Part DescriptionTo CallToll FreeFor Parts:1-800-366-PART(1-800-366-7278)1-800-4-MY-HOME(1-800-469-4663)For Service:The model number of your Air Conditioner can be found on the right side of the cabinet.All repair parts listed are available for immediate purchase or speci …
580.75135501(12 pages) |
Sony Portable Multimedia Player SMP-NX20Sony Product User Guide: SMP-NX20 PDF Quick setup manual - 3K33A9 SMP-NX20, 2 |
Thor Digital Media Converter HDV-S001Thor Digital Media Converter Operation manual (File: thor-digital-hdv-s001-operation-manual-7, 12.01.2024) HDV-S001, 7 |
RS PRO Test Equipment RSHS800 Series#5UNFD2 RSHS800 Series: RS PRO Test Equipment Owner Documentation RSHS800 Series, 208 |
American Standard Plumbing Product WILLIAMSBURG 2804American Standard WILLIAMSBURG 2804 User Manual (Installation instructions), @6WV5M8 WILLIAMSBURG 2804, 4 |
Siemens Protection Device 7UM515Siemens Protection Device 7UM515 Instruction manual 7UM515, 232 |
Air King Fan AKF100LSOperating manual for Air King AKF100LS Fan AKF100LS, 12 |
HP Laptop LaptopHP Laptop Operation & user’s manual (File: hp-laptop-operation-user-s-manual-126, Wednesday 20-09-2023) Laptop, 126 |
Whirlpool Washer WTW4950XW2Washer Use and care manual (Whirlpool WTW4950XW2) WTW4950XW2, 36 |
SymNet Stereo System ExpressCobra Series#I7N861: ExpressCobra Series Stereo System Quick start manual ExpressCobra Series, 20 |
Texas Instruments Computer Hardware OMAP35 SeriesTexas Instruments OMAP35 Series User Manual (Operation & user’s manual), @B8WFQ1 OMAP35 Series, 238 |
powersoft Amplifier M50Qpowersoft M50Q User Guide (Operation & user’s manual), @F45691 M50Q, 39 |
DOD Dash Cameras LS475WDOD Product Manual: LS475W PDF Operation & user’s manual - 5U1C68 LS475W, 33 |