Data-Linc Group DLM4500 Operation & User’s Manual
|
Data-Linc Group DLM4500, DATA-LINC GROUP 30 PN 161-10008-001A rev 4/04 DLM4500 User Guide Terse and Verbose Result Codes 0 OK Command executed 1 CONNECT Modem connected to line 2 RING Ring signal detected 3 NO CARRIER Carrier signal lost or not detected 4 ERROR Invalid command 5 * CONNECT 1200 Connected at 1200 bps 6 NO DIALTONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER No answer at remote end 10* CONNECT 2400 Connected at 2400 bps 11* CONNECT 4800 Connected at 4800 bps 12* CONNECT 9600 Connected at 9600 bps 13* CONNECT 14400 Connected at 14400 bps 14* CONNECT 19200 Connected at 19200 bps 24* CONNECT 7200 Connected at 7200 bps 25* CONNECT 12000 Connected at 12000 bps 26* CONNECT 16800 Con
Data-Linc Group DLM4500, DATA-LINC GROUP 12 PN 161-10008-001A rev 4/04 DLM4500 User Guide Technical Specifications ecafretnI232SRECDelameF9-BD setaRataDtroPlaireS ,002,511,006,75,004,83,002,91,006,9,008,4,004,2,002,1,003 spb004,032dna )lanoitpO(ecafretnI584-EAcn/+/-/cn-pirtSreirraBnoitisoP4 )lanoitpO(ecafretnI224-EA +ID/-ID/+OD/-OD-pirtSreirraBnoitisoP4 krowten224-SRnommocano224-EA/0054MLD6fomumixaM egnaR224dna584-EA daoLdnaeziSeriWnosdnepeD-mumixam.tf0001 etaRataD224dna584-EAspb002,511otpU tamroFataD .stib11ro01suonorhcnysa,yranib,laireS srotacidnIDEL )neerg(TUOataDdna,)wolleY(NIataD,)reb
Data-Linc Group DLM4500, DATA-LINC GROUP 9 DLM4500 User Guide PN 161-10008-001A rev 4/04 8. The DLM4500 will be configured to your application if the information was supplied to Data-Linc Group during the order process. if not the Modem Mode (ie Master or Remote), Baud Rate and other paramater should be checked before connecting the modems (See Quick Configuration for help) 9. Connect a Master configured DLM4500 to a Remote configured DLM4500 using a phone RJ-11 cord. The modems will automatically connect after approximately 30 seconds. The carrier LED on both modems should li
DATA-LINC GROUP 17 DLM4500 User Guide PN 161-10008-001A rev 4/04 AT Commands AT Attention Code Values: n/a Description: The attention code precedes all command lines except A/, A:, and escape sequences. ENTER Key Values: n/a Description: Press the ENTER (RETURN) key to execute most commands. A Answer Values: n/a Description: Answer call before final ring. A/ Repeat Last Command Values: n/a Descrip
Data-Linc Group DLM4500, DATA-LINC GROUP PN 161-10008-001A Rev 4/04 DLM4500 User Guide Patents This device covered by one or more of the following patents: 6,031,867; 6,012,113; 6,009,082; 5,905,794; 5,864,560; 5,815,567; 5,815,503; 5,812,534; 5,809,068; 5,790,532; 5,764,628; 5,764,627; 5,754,589; D394,250; 5,724,356; 5,673,268; 5,673,257; 5,644,594; 5,628,030; 5,619,508; 5,617,423; 5,600,649; 5,592,586; 5,577,041; 5,574,725; D374,222; 5,559,793; 5,546,448; 5,546,395; 5,535,204; 5,500,859; 5,471,470; 5,463,616; 5,453,986; 5,452,289; 5,450,425; D361,764; D355,658; D355,653; D353,598; D353,144; 5,355,365; 5,309,562; 5,301,274 Other Patents Pending.
Data-Linc Group DLM4500, DATA-LINC GROUP 10 PN 161-10008-001A rev 4/04 DLM4500 User Guide Quick Configuration ***For Most Applications the DLM4500 Comes Preconfigured Note: The Enter key produces the ASCII character ‘cr’ carriage return (decimal 13, hex 0d). Note also that there are no ‘O’s (ohs) in any of the following AT command string. All round characters are the number zero (0). To verify the settings before and after changing parameters type the command string: AT&V (Enter) then examine the settings and registers displayed on the screen. A. Set to Chipset’s default AT&F0 (Enter) Responds OK B. Set Connection and Correction Modes AT&D0&K0#P0%C0\K3\N4%E0$LB=3&W
Data-Linc Group DLM4500, DATA-LINC GROUP 26 PN 161-10008-001A rev 4/04 DLM4500 User Guide $LB= n Lenth of Break Values: n = 0-255 (1 = 10ms) Default: 003 (30 ms) $MB n Online BPS Speed Values: n = speed in bits per second Default: 28,800 Description: $MB75 Selects CCITT V.23 mode $MB300 Selects 300 bps on-line $MB1200 Selects 1200 bps on-line $MB2400 Selects 2400 bps on-line $MB4800 Selects 4800 bps on-line $MB9600 Selects 9600 bps on-line $MB14400 Selects 14,400 bps on-line $MB19200 Selects 19,200 bps on-line $MB28800 Selects 28,800 bps on-line $MB33600 Selects 33,600 bps on-line $SB n Serial Port Baud Rate
Data-Linc Group DLM4500, DATA-LINC GROUP 13 DLM4500 User Guide PN 161-10008-001A rev 4/04 Technical Specifications Cont. sedoM A121lleB;22.V,siv22.V,23.V,sib23.V,43.V,43.V,decnahne43.V 311/301dna setaRataDtneilC-ot-tneilC ,008,61,002,91,006,12,000,42,004,62,008,82,002,13,006,33 spb003-0,002,1,004,2,008,4,002,7,006,9,000,21,004,41 thgieW)gk67.(.bl86.1 noisnemiDerusolcnE segnalfgnitnuomrevo)mc49.3x54.21x68.22("45.1x"9.4x"0.9 lairetaMerusolcnEleetseguag81 noitartsigeRCCFE-5M-41852-ASU-7UAgeRCCF
Data-Linc Group DLM4500, USER GUIDE I NDUSTRIAL D ATA C OMMUNICATIONS It is essential that all instructions contained in the User Guide are followed precisely to ensure proper operation of equipment. Dial-Up/Leased Line Modem DLM4500
Data-Linc Group DLM4500, DATA-LINC GROUP 4 PN 161-10008-001A rev 4/04 DLM4500 User Guide Connection Points and LED Descriptions Figure 1 Front Panel Connections – (Left to Right) RJ-11 — Phone Line DB-9 — Data Port RS232 pin 1 CD Out (Carrier Detect) pin 2 Data Out pin 3 Data In pin 4 DTR In (Data terminal ready) pin 5 Signal Ground pin 6 DSR Out (Data set ready) pin 7 RTS In (Request to send) pin 8 CTS (Clear to send) pin 9 N/C Push-Button Switch — Modem Reset Led Array O - Green (data out/line i
DATA-LINC GROUP 1 DLM4500 User Guide PN 161-10008-001A rev 4/04 Table of Contents Page Introduction 3 Connection Points and LED Descriptions 4 Equipment Connections and Interface Descriptions 5 Quick Start 7 Quick Configuration 10 Technical Specifications 12 Technical Support 14 Return Material Authorization 14 Contact Information 14 Appendix A Enclosure Dimensions 15 Appendi
Data-Linc Group DLM4500, DATA-LINC GROUP 21 DLM4500 User Guide PN 161-10008-001A rev 4/04 X n Result Code Selection Values: n = 0–7 Default: 4 Description: X0 Basic result codes ( e.g., CONNECT ); does not look for dial tone or busy signal. X1 Extended result codes ( e.g., CONNECT 46000 V42bis ); does not look for dial tone or busy signal. X2 Extended result codes with NO DIALTONE ; does not look for busy signal. X3 Extended result codes with BUSY ; does not look for dial tone. X4 Extended result codes with NO DIALTONE and BUS
Data-Linc Group DLM4500, DATA-LINC GROUP 14 PN 161-10008-001A rev 4/04 DLM4500 User Guide Technical Support Data-Linc Group maintains a fully trained staff of service personnel who are capable of providing complete product assistance. They can provide you with technical, application, troubleshooting, and warranty assistance. Our technical staff is based in Bellevue, Washington USA and may be reached at (425) 882-2206 or e-mail [email protected] Product Warranty Data-Linc Group warrants equipment of its own manufacture t
Data-Linc Group DLM4500, DATA-LINC GROUP 29 DLM4500 User Guide PN 161-10008-001A rev 4/04 S48 decimal 7 or 128 7 Enables (7) or disables (128) LAPM negotiation. The following table lists the S36 and S48 configuration settings for certain types of connections. S48=7 S48=128 S36=0, 2 LAPM or hang up Do not use S36=1, 3 LAPM or async Async S36=4, 6 LAPM, MNP, or hang up MNP or hang up S36=5, 7 LAPM, MNP, or async MNP or async S89 seconds 0, 5–255 10 Sets the length of time in the off-line command mode before the modem goes into standby mode. A
Data-Linc Group DLM4500, DATA-LINC GROUP 25 DLM4500 User Guide PN 161-10008-001A rev 4/04 C\T n Inactivity Timer Values: n = 0, 1–255 Default: 0 Description: Sets the time (in minutes) after the last character is sent or received that the modem waits before disconnecting. A value of zero disables the timer. Applies only in buffer mode. Note: You can also set the inactivity timer by changing the value of S30 . \V n Protocol Result Code Values: n = 0, 1, or 2 Default: 1 Description: \V0 Disables the appending of the protocol result code to the DC
Data-Linc Group DLM4500, DATA-LINC GROUP 23 DLM4500 User Guide PN 161-10008-001A rev 4/04 &T n Loopback Test (V.54 Test) Commands Values: n = 0, 1, 3, 6 Default: None Description: The modem can perform selected test and diagnostic functions. A test can be run only when the modem is operating in non-error-correction mode (normal or direct mode). For tests 3 and 6, a connection between the two modems must be established. To terminate a test in progress, the escape sequence ( +++) must be entered. &T0 Stops any test in progress
Data-Linc Group DLM4500, DATA-LINC GROUP 20 PN 161-10008-001A rev 4/04 DLM4500 User Guide X n Result Code Selection Values: n = 0–7 Default: 4 Description: X0 Basic result codes ( e.g., CONNECT ); does not look for dial tone or busy signal. X1 Extended result codes ( e.g., CONNECT 46000 V42bis ); does not look for dial tone or busy signal. X2 Extended result codes with NO DIALTONE ; does not look for busy signal. X3 Extended result codes with BUSY ; does not look for dial tone. X4 Extended result codes with NO DIALTONE and BUSY . X5 Extended result codes with NO DIALTONE and BUSY . X6 Extended result codes with NO DIALTONE and BU
DATA-LINC GROUP 22 PN 161-10008-001A rev 4/04 DLM4500 User Guide &G n V.22bis Guard Tone Control Values: n = 0, 1, or 2 Default: 0 Description: &G0 Disable guard tone. &G1 Set guard tone to 550 Hz. &G2 Set guard tone to 1800 Hz. Note: The &G command is not used in North America. &K n Flow Control Selection Values: n = 0, 3, or 4 Defaults:
Data-Linc Group DLM4500, DATA-LINC GROUP 15 DLM4500 User Guide PN 161-10008-001A rev 4/04 Appendix A Enclosure Dimensions 2.45 in 6.22 cm Reference 9.00 in 22.86 cm 4.90 in 12.45 cm 2.75 in 6.99 cm Slot Center Reference 1.08 in 2.74 cm 4 Places Ø 0.25 in 64 cm Two Places 1.00 in 2.54 cm 4 Places 8.30 in Center Reference 1.54 in 3.94 cm 0.06 in .15 cm 7.75 in 19.69 cm 0.35 in .89 cm 4 Places 21.08 cm
Data-Linc Group DLM4500, DATA-LINC GROUP 11 DLM4500 User Guide PN 161-10008-001A rev 4/04 Short Description of AT Commands Used in Quick Configure Sections Reconfiguring a DLM4500 after setting it to Leased Line mode Since there is no jumper or switch to change between Leased Line and Dial-Up/Command Mode on the DLM4500, a special AT command is used during a 10 second time window after powering up or pressing the reset switch to allow changing modem settings. To get a Leased Line configured DLM4500 modem into Command Mode follow these steps: -Remove power from DLM4500 -Connect PC to RS232
Data-Linc Group DLM4500, DATA-LINC GROUP 3 DLM4500 User Guide PN 161-10008-001A rev 4/04 Introduction The Data-Linc Group DLM4500 modem is designed to work on public dial-up telephone systems. The modem will work on both dial-up voice grade phone lines and leased lines. It connects to a normal telephone service using a RJ-11 jack (2 wire) and connects to the users equipment via a 9-pin DB-9 connector utilizing RS232 signals and screw terminals if a AE-485 (2-wire) or AE-422 (4-wire) unit. The Data-Linc Group DLM4500 is a compact modem designed and manufactured to operate in industrial applications. It has a wide D
DATA-LINC GROUP 28 PN 161-10008-001A rev 4/04 DLM4500 User Guide S37 decimal 0–19 0 Sets the maximum V.34 “upstream” speed at which the modem attempts to connect. 0 = maximum speed 1 = reserved 2 = 1200/75 bps 3 = 300 bps 4 = reserved 5 = 1200 bps 6 = 2400 bps 7 = 4800 bps 8 = 7200 bps 9 = 9600 bps 10 = 12000 bps 11 = 14400 bps 12 = 16800 bps 13 = 19200 bps 14 = 21600 b
Data-Linc Group DLM4500, DATA-LINC GROUP 19 DLM4500 User Guide PN 161-10008-001A rev 4/04 O n Return Online to Data Mode Values: 0, 1, 3 Default: None Description: O0 Exit online command mode and return to data mode. O1 Issue a retrain and return to online data mode. O3 Issue a rate renegotiation and return to data mode. P Pulse Dialing Values: P, T Default: T Description: Configures the modem for pulse (non-touch-tone) dialing. Dialed digits are pulsed until a T command or dial modifier is received. Q n Result Codes Enable/Disable Values: n = 0 or 1 De
DATA-LINC GROUP 7 DLM4500 User Guide PN 161-10008-001A rev 4/04 Dial Up Quick Start and Testing The following setup procedure is for a DLM4500 in Dial-Up mode. It assumes that two phone jacks of dial-up lines are available 1. Unpack the modem(s). 2. Verify that you have all of the parts and cables to power and connect the modem to your equipment. You must be using
Data-Linc Group DLM4500, DATA-LINC GROUP 16 PN 161-10008-001A rev 4/04 DLM4500 User Guide Appendix B AT Commands, S-Registers and Result Codes The AT commands are used to control the operation of your modem. They are called AT commands because the characters AT must precede each command to get the attention of the modem. AT commands can be issued only when the modem is in command mode or on-line command mode. The modem is in command mode whenever it is not connected to another modem. The modem is in data mode whenever it is connected to another modem and ready to exchange data. On-line command mode is a temporary
Data-Linc Group DLM4500, DATA-LINC GROUP 6 PN 161-10008-001A rev 4/04 DLM4500 User Guide AE-485 The AE-485 connection is made with one wire pair. This pair has a plus (+) and a minus (-) polarity. After connecting the wire pair, send some data out of the connected equipment. The Data-In LED on the front panel should flash. If it does not, invert the wire pair and try again. Data-Linc Group AE-485 usually connects the ‘+’ to an A contact and connects the ‘–‘ wire to a B contact. If no LED’s blink, then some things that could be wrong. (Note
Data-Linc Group DLM4500, DATA-LINC GROUP 8 PN 161-10008-001A rev 4/04 DLM4500 User Guide 11. The modem will now take the phone line Off- hook and dial when the dial tone is received. The speaker will make several noises including the dial tone. If a connection is made the modems speaker will go off, the Amber (carrier) LED will illuminate and ‘Connect xxxx’ will display, where xxxx is the baud rate, and after that will display the error correction modes if any is used.. If using a terminal program the modem will automatically be set in data transfer mode. Failure to make a connection can be the result of: a. Wrong phone number. Use a regular
Patton electronics 2192 Modem Operation & user’s manual
2192 |
D-Link DSL-302G Modem Quick installation manual
DSL-302G |
Olitec Speed'Com 56000 Modem Operation & user’s manual
Speed'Com 56000 |
Data-Linc Group DLM4000 Modem Operation & user’s manual
DLM4000 |
Aztech WIPC302 Modem Manual
WIPC302 |
Data-Linc Group PLR5000 Modem Operation & user’s manual
PLR5000 |
Surfing Machine SM-100 Modem Installation manual
SM-100 |
Campbell COM210 Modem Instruction manual
COM210 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Brother | HL-3450CN | Parts reference list | brother/hl-3450cn-4Z1.pdf | 30 Jul 2023 | 25 | 0.58 Mb |
2 | Bosch | MCM 5000m | Owner's manual | bosch/mcm-5000m-2R8.pdf | 24 Oct 2022 | 28 | 1.55 Mb |
3 | Crest Audio | FXA3601 | Specifications | crest-audio/fxa3601-9N9.pdf | 21 Mar 2023 | 2 | 0.06 Mb |
4 | Indesit | IWD 6125 | User manual manual | indesit/iwd-6125-N42.pdf | 10 May 2023 | 16 | |
5 | Duerkopp Adler | 467 | Spare parts | duerkopp-adler/467-FD8.pdf | 28 Aug 2022 | 47 | 18.45 Mb |
6 | MasterForce | 241-0300 | Operator's manual | masterforce/241-0300-PK5.pdf | 08 Sep 2022 | 24 |
Clas Ohlson
EnglishSvenskaNorskSuomiWireless USB Network AdaptorTrådlöst nätverkskort USBTrådløst nettverkskort USBLangaton verkkokortti USBArt.no. Model38-4444 GN-WB32L-RHVer. 201101
…
GN-WB32L-RH(52 pages) |
NETGEAR
Connect any device with a network port to your existing home wireless network• Wirelessly connects networked home theater devices such as Xbox 360®, PS3™, TiVo®, VUDU, Blu-ray player, and Internet TVs to your home network.• Universal—works with any network enabled device. No need to buy a Wi-Fi adapter that only works with one type of device• P …
WNCE2001 - Ethernet to Wireless Adapter(2 pages) |
Tenda
Table of Contents Chapter One TED8620R+ Introduction .................................. 1 1.1 Product Features ....................................................................................1 1.2 Unpacking..............................................................................................2 1.3 Physical Environmental Requirements .......... …
TED8620R(29 pages) |
Hitachi
ANGLOPACK Quick Setup Guide Required configuration - A standard line: non-shared analog (excluding “Numeris” and switchboard) - A subscription to the ADSL service AngloPack from Teleconnect - A standard telephone (optional) - A computer with the following characteristics: • PC running Windows 98SE, 2000, Me, XP, Vista • Memory: 64 M …
H4021(6 pages) |
DStv
ARRIS Global LimitedVictoria RoadSaltaireBD18 3LFUnited Kingdomwww.arris.com© ARRIS Enterprises, LLC. 2016 All rights reserved. No part of this publication may be reproduced in any form or by any means or used to make any derivative work (such as translation,transformation, or adaptation) without written permission from ARRIS Enterprises, Inc. (“ARRIS”) …
USB3000(2 pages) |
Tenda
Copyright Declaration is the registered trademark of Shenzhen Tenda Technology Co., Ltd. Other trademark or trade name mentioned herein are the trademark or registered trademark of the company. Copyright of the whole product as integration, including its accessories and software, belongs to Shenzhen Tenda Technology Co., Ltd. Without the permission of Shenz …
TED8620B+(18 pages) |
Altec Lansing Other 409-8C CEILING SPEAKERManual: Altec Lansing 409-8C CEILING SPEAKER (4FK73S, Upd.Mon 01.2024) 409-8C CEILING SPEAKER, 2 |
Danfoss Thermostat 088U0215Danfoss Thermostat Instruction (File: danfoss-088u0215-instruction-16, 09.01.2024) 088U0215, 16 |
Kleenmaid Cooktop CH311XFFUser Manual: Kleenmaid CH311XFF (2CXF38, Upd.Wednesday 07-02-2024) CH311XFF, 18 |
Sealife Camera Lens SL320Sealife SL320 Camera Lens Instruction manual SL320, 12 |
Native Instruments Drums AbbeyRoad 60sDrums Operation & user’s manual (Native Instruments AbbeyRoad 60s) AbbeyRoad 60s, 26 |
Heli-Max Toy AXE Mini EP RTFAXE Mini EP RTF (Toy ePDF User Manual, #2TTI74) AXE Mini EP RTF, 20 |
Seagull Models Toy ZERO FIGHTERAssembly manual for Seagull Models ZERO FIGHTER Toy ZERO FIGHTER, 22 |
Kenwood Amplifier Basic C2Kenwood Amplifier Basic C2 Instruction manual Basic C2, 11 |
ViewSonic Camcorder 3DV5#CAIX8H 3DV5: ViewSonic Camcorder Owner Documentation 3DV5, 23 |
Compaq Network Card 11241124 (Network Card ePDF Guide, #256134) 1124, 30 |
Tricity Bendix Microwave Oven TRIC750EGMicrowave Oven Operating & installation instructions manual (Tricity Bendix TRIC750EG) TRIC750EG, 20 |
Philips Amplifier 32PW9523 - annexe 1Philips Product User Guide: 32PW9523 - annexe 1 PDF Manual - HLJDQT 32PW9523 - annexe 1, 22 |