Manualios.com

Philips PL1 Installation & User Manual

Philips PL1 Manual Online:

3.75, 2628 votes
Philips PL1 User Manual
Philips PL1 User Guide
Philips PL1 Online Manual

Text of Philips PL1 User Guide:

  • Philips PL1, Settings 17 PL1 LED Luminaires Installation & User’s Manual Note: To Exit the Settings screen, use the [ESC] key. [ESC] and [OK] can be used to cancel or save changes to an individual parameter. However, once a parameter has been accepted, by pressing [OK] that change cannot be undone/ canceled by pressing the [ESC] key. General 1 Power Limit 30W, 40W, 50W, 70W, 90W, 100W, 120W 120W Sets the maximum power setting of the LED engine. 1 Power-Up Off, Scratch Pad, Warm White, Cool White, Day Light, Preset30, Preset31, Last Set Cool White When the Fixture Powers-Up wha

  • Philips PL1, LCD Menu System 11 PL1 LED Luminaires Installation & User’s Manual 2. LCD Menu System The LCD Display Menu system consists of several categories. Use the four arrow buttons as required (refer to Figure 2 on page 10) to access and make changes to the menu items. When the desired menu item is reached, press [OK] to display the menu options. Use navigation and [OK] buttons to view status and configure the LCD Menu as required. Note: Depending on the security settings, certain menu items may be password protected. You must

  • Infrared Remote Control Overview 29 PL1 LED Luminaires Installation & User’s Manual INFRARED REMOTE CONTROL 1. Infrared Remote Control Overview The PL1IRR infrared preset programming remote (sold separately) allows users convenient access to adjust and program luminaire parameters - presets (1 through 6 and Off), intensity, preset color temperatures, or full color mixing from the fl

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 10 OPERATION AND PROGRAMMING OPERATION AND PROGRAMMING 1. LCD Menu Operation The PL1 LED Luminaire’s LCD Display and Menu System provides local control for accessing all the fixture’s status information, menu options, and settings. Note: If there are multiple luminaires in a system, changes would need to be made at each LCD Menu as desired. Upon power up, the LCD will display the main screen showing the product type/name. If DMX is enabled, the programmed address will appear after power up.

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 28 DMX CONTROL Note: * DMX values 250 to 255 provide smoothing when using console fade timing. DMX value 255 (recommended default) will provide the smoothest timing. 84 214 134 215 135 216 136 85 217 137 218 138 86 219 139 220 140 221 141 87 222 142 223 143 88 224 144 225 145 226 146 89 227 147 228 148 229 149 90 230 150 231 151 91 232 152 233 153 234 154 92 235 155 236 156 93 237 157 238 158 239 159 94 240 160 241 161 95 242 162 243 163 244 164 96 245 165 246 166 97 247 167 248 168 249 169 98 250* 60mS 251* 80mS 99

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 8 INSTALLATION AND SET UP WARNING! Before attempting any installation or service, disconnect all power at power source. Turning off the luminaire does not disconnect power. Installation and service should only be performed by a trained and qualified professional. Be sure to check circuit capacity before installing luminaires. PL1 LED Luminaire - Track Mounted Models PL1 LED Luminaire - Ceiling Mounted Models WARNING! All PL1 LED Luminaires must be mounted - vertically - as shown above to allow proper cooling. Luminaire head may be positioned as desired. PL1 LED

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 2 TABLE OF CONTENTS TABLE OF CONTENTS Philips Selecon Offices................................................................................................................................................................. Inside Front Cover IMPORTANT INFORMATION Warnings and Notices..................................................................................................................................................................

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 6 INSTALLATION AND SET UP INSTALLATION AND SET UP 1. Power Requirements The PL1 LED Luminaire operates on 120 to 240 volts AC (+/- 10%, auto-ranging). The luminaire contains an auto- ranging power supply. Depending on supply voltage, each luminaire can draw up to 1.91 amps. 2. Connecting Power If the unit is supplied with an AC input cable, Table 2 describes how to connect power to your PL1 LED Luminaire . Field wiring of the PL1 LED Luminaire is straight forward. A total of 3 wires/conductors need to be

  • Philips PL1, About this Manual 3 PL1 LED Luminaires Installation & User’s Manual PREFACE 1. About this Manual The document provides installation and operation instructions for the following products: • PL1 LED Luminaires (refer to "Product Descriptions" for individual product models). Please read all instructions before installing or using this product. Retain this manual for future reference. Additional product information and descriptions may be downloaded at www.seleconlight.com 2. Product Descriptions This manual covers the following PL1 LED Luminaire models: PL1 LED Luminaire Spot with Local / DMX512 / IR Control (North American Marke

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 12 OPERATION AND PROGRAMMING Menu Structure Note: See "To navigate and access menu settings/selections:" on page 11 to learn how to access menus. To save changes, hit [OK]. Press [ESC] to cancel any changes you made. MAIN MENU Save as Preset Sub Menu Options Comments Select Preset to Save - (Option) Scrolls and sets current user-defined color mix to various recallable presets in the fixture using arrow buttons. Note: To edit a current (set) preset, see Edit Presets. Off Users can: • Save the current settings (look) to a specific recallable Preset in the fixture’s memory. • Edit the levels (val

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 30 INFRARED REMOTE CONTROL To select and program PL1 LED luminaire with PL1IRR remote: Note: The IR, on the PL1 LED luminaire, must be set to "Enabled" in order for the PL1IRR remote to communicate and control the fixture. Refer to PL1 LED Luminaire Installation & User’s Manual on luminaire menu settings. Step 1. Point PL1IRR programming remote Laser / IR window directly at luminaire IR programming window (as shown in Figure 4) and hit "Enter" button. Note, each luminaire to be programmed/adjusted needs to be selected and programmed/adjusted individually. Figure 4: PL1 LED Luminair

  • Installation & User’s Manual PL1 LED Luminaires 32 CLEANING AND CARE Step 3. Before opening luminaire head cover, note position of lens focus/zoom knob position (to reset focus/zoom position after completion of procedure). Step 4. At luminaire head cover (as shown in Figure 5), using 3 mm Allen hex key, completely loosen three captive screws securing cover. Figure 5: PL1 LED Lumin

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 14 OPERATION AND PROGRAMMING Menu Structure (continued) 3. Security Unwanted changes to the Fixture's Configuration or Setting can be controlled by setting a security level, or Locking the Fixture. Three levels of security are available in addition to completely Locking the Fixture. PL1 luminaires are shipped with default passwords. Users may set their own password (four-digit number). When setting a password, write it down and keep it in a secure location. Note, Philips Selecon does not have records of passwords est

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 18 DMX CONTROL DMX CONTROL This section contains information for operating the luminaire using DMX control in 16-Bit, 8-Bit, or 3-Channel (3- Chan) modes. For Menu options and detailed information, see "Settings" on page 16. Note: These tables assume a DMX start address of 1. When a different starting address is used, this address becomes channel 1 function and other functions follow in sequence. 1. 16-Bit Mode Table 3 provides DMX channe

  • Philips PL1, Presets 15 PL1 LED Luminaires Installation & User’s Manual Step 3. Select a Level to change ( Level 1 PIN / Level 2 PIN / Level 3 PIN). Step 4. Press [OK] to edit using the [UP ARROW], [DOWN ARROW], [LEFT ARROW] or [RIGHT ARROW] keys to enter a four-digit password (using 0 to 9). Step 5. Press [OK] to save changes. If you hit [ESC] (Escape) password will not be stored and process must be repeated. Step 6. Password is set. Note: The current security level is displayed next to the Security heading. Only Passwords at, or below, that level will be di

  • Philips PL1, PL1 LED Luminaire Common Specifications 35 PL1 LED Luminaires Installation & User’s Manual TECHNICAL SPECIFICATIONS 1. PL1 LED Luminaire Common Specifications Source: True RGBW 120 Watt LED chip Beam Spread: 14 to 50+ degrees Light Output: > 2,000 lumens Color Temperature: 3000 - 5600K (user adjustable) Input Voltage: 120V to 240V (+/- 10%, auto-ranging) Current: 1.91 Amps (90V) / 0.72 Amps (240V) Frequency: 50/60Hz Ambient Temperature: 0 to 40 degrees C (32 to 104 degrees F) Humidity: 5%-95% Non condensing Cooling: Forced-Air Weight: 8.0 lbs (3.6 kg) - Luminaire only (no mount, AC input cable or accessor

  • Philips PL1, Special Cleaning and Care Instructions 31 PL1 LED Luminaires Installation & User’s Manual CLEANING AND CARE WARNING! All cleaning should be performed with power completely removed from the luminaire. Never remove protective covers when luminaire is powered. Wear appropriate protective eye wear and gloves when cleaning the fixture. All service and maintenance, other than described herein, should be performed by a qualified technician or Authorized Service Center. 1. Special Cleaning and Care Instructions Being a solid-state fixture, and unlike most fixtures, the PL1 LED Lum

  • Philips PL1, Lighting Console Settings for Preset White 23 PL1 LED Luminaires Installation & User’s Manual 4. Lighting Console Settings for Preset White 16-Bit Mode Below are the DMX512 console values and levels* for Warm White, Cool White, and Day Light presets in 16-bit mode. 8-Bit Mode Below are the DMX512 console values and levels* for Warm White, Cool White, and Day Light presets in 8-bit mode. Note: *Values and levels shown for Preset White (in both 16 and 8-bit modes) are approximate. Due to the characteristics of LED technology, actual values may vary slightly between fixtures. 5. PL1

  • 16-Bit Mode 19 PL1 LED Luminaires Installation & User’s Manual 13 Intensity Time 0 - 255 0 - 100% 255 Allows for luminaire timing of intensity. Profile should default to DMX 255 for smoothest console fade times. Refer to "PL1 Luminaire DMX Timing Channel Detail" on page 23 for more information on timing values. 14 Color Time 0 - 255 0 - 100% 255

  • LCD Menu System 13 PL1 LED Luminaires Installation & User’s Manual Menu Structure (continued) Edit a Preset Sub Menu Options Comments Select Preset to Edit - (Option) Selects a current preset and outputs the preset, so preset can be edited. Note: To save a specific look of the fixture, see Save Presets. Off Users can: • Edit the current settings (look) to a specific recallab

  • Philips PL1, 1 PL1 LED Luminaires Installation & User’s Manual IMPORTANT INFORMATION Warnings and Notices Additional Resources for DMX512 For more information on installing DMX512 control systems, the following publication is available for purchase from the United States Institute for Theatre Technology (USITT), "Recommended Practice for DMX512: A Guide for Users and Installers, 2nd edition" (ISBN: 9780955703522). USITT Contact Information: USITT 315 South Crouse Avenue, Suite 200 Syracuse, NY 13210-1844 Phone: 1.800.938.7488 or 1.315.463.6463 www.usitt.org Philips Selecon Limited Three-Year Warranty Philips

  • Philips PL1, Installation & User’s Manual PL1 LED Luminaires 16 OPERATION AND PROGRAMMING Preset 0, the "off" preset is also Locked to the OFF value. Protected Protected Presets are also Factory Calibrated, and by default are Protected from changes to their Color Mix. Their Intensity can be changed. Protected Presets are Presets 5-25. They can be Un-Protected by setting "Protected" to "No"; see section on Settings. If Un-Protected these presets function like User Presets. The Factory Calibrated values for the protected presets can be re-loaded to the original factory calibration settings by setting "Load Factory" to "Yes" &q

  • Installation & User’s Manual PL1 LED Luminaires 20 DMX CONTROL 2. 8-Bit Mode Table 2-1 provides DMX channel mapping of all DMX512 control values when the PL1 LED Luminaire is in 8-bit DMX512 mode (as set by the luminaire’s menu system). Table 2-1: PL1 LED Luminaire DMX Channel Mapping (8-Bit Mode) DMX Channel Parameter Range DMX Range% Default - recom

Related Products and Documents (Lantern):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kenwood KRC-560 Instruction manual kenwood/krc-560-7M5.pdf 04 Jun 2023 46
2 Combi 9800 Instruction manual combi/9800-D4L.pdf 21 Sep 2022 8 0.35 Mb
3 Insignia NS-5HTV Operation & user’s manual insignia/ns-5htv-X31.pdf 11 Aug 2022 78
4 Lathem PC3500TX Installation & user manual lathem/pc3500tx-UEH.pdf 23 Jan 2024 33
5 Cypress Semiconductor CY7C1443AV33 Specification sheet cypress-semiconductor/cy7c1443av33-Z2F.pdf 01 May 2023 31 0.93 Mb
6 Acer Extensa 5630G Manual  acer/extensa-5630g-NV6.pdf 18 Oct 2022 14

Similar Resources:

  • Midstream

    Titan Series

    (7 pages)
    INSTALLATION GUIDANCETitan Series1R23 4 567 89101112 1314 15 16 171819 2021 22 23 24QPONMLIHGFEDCBA12 34567 8 9 10 1112 13141516171819 20212223 24ILMNOPQRGFEDCBAHMIDSTREAMREV. DOCUMENT N° DESCRIPTION ZONE DATE DRAWN CHECKEDThis drawing is property of MIDSTREAM LIGHTING LTD. All rights reserved the partial or total reproduction of it is forbidden without e …
  • Clas Ohlson

    ZK7029

    (2 pages)
    GREAT BRITAIN • customer service tel: 020 8247 9300 e-mail [email protected] internet www.clasohlson.co.uk postal: 10 – 13 Market Place, Kingston Upon Thames, Surrey, KT1 1JZSVERIGE • kundtjänst tel. 0247/445 00 fax 0247/445 09 e-post kundservice@claso hlson.se internet www.clasohlson.se brev: Clas Ohlson AB, 793 85 INSJÖNNORGE …
  • P4

    KLIPPA Bulkhead Series

    (2 pages)
    Ambient temperatureConformityBSEN 60.598-2-22Leading the way in self testing emergency lightingInstallation and Operating Instructions forKLIPPA LED Bulkhead & KLIPPA 8W BulkheadK-LED/N/M3, K-LED/N/M3-SRMK8/N/M3 & K8/N/M3-SRMP4 Limited1 Wymans Way, Fakenham, Norfolk NR21 8NTT: 01328-850555F: 01328-850559E: info@ …
  • Inspire

    Nanuta

    (25 pages)
    NanutaEAN CODE: 32760007009822Manual de Instruções Руководства поЭксплуатацииManuel d'InstructionsΕγχειρίδιο ΟδηγιώνІнструкція З Експлуатації Manual de InstruccionesInstrukcją ObsługiManual de InstrucţiuniFR ES PT ITEL PLUARUKZManual de InstruçõesROManuale di IstruzioniПайдал� …
  • Eaton

    Crouse-hinds series

    (12 pages)
    SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCEIF 1767ACE-DG1 Variable Frequency Drive SystemInstallation & Maintenance InformationIF 1767 • 09/15 Copyright© 2015, Eaton’s Crouse-Hinds Division Page 1TABLE OF CONTENTS1. Safety Instructions 1.1 Appl …
  • BJ TAKE

    LWSL Series

    (3 pages)
    BJ Take Inc 220 Ramsey Drive Dunnville, ON N1A 0A7 1 of 3 LWSL Series LED Surface/Suspended Ambient Luminaire Important Safeguards: When using electrical equipment, basic safety precautions should always be followed including the following: Read and follow all safety instructions 1. Danger - Risk of shock - Disconnect pow …

Comments, Questions and Opinions: