  • bsg Savio FP, Savio FP Savio FP USER MANUAL AND INSTRUCTIONS WALL HUNG GAS BOILER FOR CENTRAL HEATING SUPPLY Please Read Instructions Carefully Save for Future Reference Do not store or use gasoline or other fl ammable vapors and liquids — in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS — Do not try to light any appliance.• Do not touch any electric switch; do not use any phone in your • building. Immediately call your gas supplier from a neighbor’s phone. Fol-• low the gas supplier’s instruct

  • bsg Savio FP, 2 SAVIO FP USER MANUAL Dear Customer: Thank you for buying a SAVIO FP Boiler System. The SAVIO FP is a high effi ciency, non-condensing, wall mounted gas boiler which provides central heat and domestic hot water. We realize that it is not possible to answer all questions about the SAVIO boiler system in this manual. Reading this installation manual does not make the reader an expert in all aspects of installation and operation, and does not replace the need for a qualifi ed, licensed heating contractor. We urge you to contact your installing contractor or distributor if you are

  • bsg Savio FP, SAVIO FP USER MANUAL 3 Table of Contents Section Title Section Number Page Number Warnings - 4-5 Important Information - 6 General Information 1 7 Technical Information 2 7-8 Appliance Description 3 9 Operation Lights 4 10 Instructions for Use 5 11-14 Warnings 5.1 11 Refi lling Procedure 5.2 11 Lighting/Operation Instruction 5.3 12 Central Heating Circuit Temp. 5.4 12-13 Extinguishing Instructions 5.5 13 Domestic hot water 5.6 14 Useful Advice 6 15-17 Central Heating 6.1 15 Frost Protection 6.2 15 Periodic Maintenance 6.3 15 Exte

  • bsg Savio FP, 4 SAVIO FP USER MANUAL WARNING DANGER Boiler is certifi ed as an indoor appliance. Do not install boiler outdoors or locate where it will be exposed to freezing temperatures. Caution: Do not store or use fl ammable materials, chemicals or fl ammable liquids, especially gasoline, in the vicinity of this heating appliance. Caution: Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. Caution: Do not use this boiler if any part has been under water. Immediately call a qualifi ed se

  • SAVIO FP USER MANUAL 5 WARNING Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of pro- ducing carbon monoxide (CO). Carbon Monoxide (CO) is a gas which is odorless, colorless and tasteless but is very toxic. CO is lighter than air and thus may travel throughout the building. BRIEF EXPOSURE TO HIGH CONCENTRATIONS OF CO, OR PROLONGED EXPOSUR

  • bsg Savio FP, 6 SAVIO FP USER MANUAL IMPORTANT INFORMATION Please read this page carefully. ALL BOILERS MUST BE INSTALLED IN ACCORDANCE WITH NATIONAL, • STATE AND LOCAL PLUMBING, HEATING AND ELECTRICAL CODES AND ORDINANCES, AS WELL AS THE REGULATIONS OF THE SERVING ELECTRICAL, WATER AND GAS UTILITIES. All systems should be designed by competent contractors, and only persons • knowledgeable in the layout and installation of heating systems should attempt the installation of any boiler. It is the responsibility of th

  • bsg Savio FP, SAVIO FP USER MANUAL 7 General Information1. Technical Information (M130.30CM)2. The SAVIO FP is a high effi ciency, non-condensing, wall mounted gas boiler which pro- vides central heat. The boiler features a gas valve which modulates the energy input from 49,476BTU/h to 122,837 BTU/h. The boiler is shipped fully assembled. All units are pressure and combustion tested at the factory prior to shipping. Key Features: Wall mountable - saving valuable fl oor • space. Several fl ue options available• El

  • bsg Savio FP, 8 SAVIO FP USER MANUAL 2. Technical Information Cont. ENERGY CAPACITY Nominal heat input (0/2000ft) MBH 122.8 Nominal heat input (2000/4500ft) MBH 116.7 Minimum heat input MBH 49.5 Maximum useful output (0/2000ft) MBH 100.7 Maximum useful output (2000/4500ft) MBH 95.9 Minimum useful output MBH 37.0 GAS SUPPLY PRESSURE Gas Normal Min Max Natural inwc 7.0 3.5 10.5 Propane inwc 11.0 8.0 13.0 GAS PRESSURE AT BURNER Gas Min Max Ignition Natural inwc 0.8 5.3 2.4 Propane inwc 1.4 9.0 5.2 FLUE DESIGN Min

  • SAVIO FP USER MANUAL 9 Appliance Description3. Overview:3.1 1 Case front panel 2 Control panel 3 Control panel cover Control Panel:3.2 4 Central heating circuit temperature and pressure gauge 5 Lock-out signal lamp 6 Boiler reset button 7 Function selector knob and radiator temperature control 8 Domestic hot water, temperature control knob 9 Appliance operation ligh

  • bsg Savio FP, 10 SAVIO FP USER MANUAL Operation Lights4. Three lights (8 in Fig. 3.2) give detailed indication regarding the operation of the boiler. The following table gives the relationship between each of the possible light combinations and their meaning. A short pulse every 4 seconds: stand-by condition Function selector in position. Anti-freeze system active 1 second pulse every 2 seconds: normally operating boiler. Function selector in on position Central heating operation Frost protec

  • bsg Savio FP, SAVIO FP USER MANUAL 11 Instructions For Use5. Warnings:5.1 In order to guarantee safety and correct operation, it is essential that all the tests are carried • out by a competent and responsible licensed service person before lighting up the boiler. The tests are described in the installation, operation and service instructions manual in Sec-• tion 15 Commissioning. Ensure that the Central Heating circuit is regularly fi lled with water checking that the pres-• sure indicated on the temperature and pressure gauge (4 on fi gure 3.2) is not lower than 1 bar (14.5 psi) as shown on fi gure 5.1. If the pressure reading on the

  • bsg Savio FP, 12 SAVIO FP USER MANUAL 5. Instructions For Use Cont. Lighting/Operating Instructions:5.3 Warnings: Do not attempt to start the boiler unless all cleanout doors are secured and sealed. Do not attempt to light the burner by hand. 1 Check that the cocks connected to the gas inlet pipe and to the supply cold wa- ter inlet pipe (see section 3.3 for pipes) are open. 2 Turn on the electricity supply to the boiler, switching on the circuit breaker. The appli- ance operation light A (fi gure 5.2) will fl ash every 4 seconds (stand-by condition). Figure 5.2 A B C D E 3 If the boiler is t

  • bsg Savio FP, SAVIO FP USER MANUAL 13 5. Instructions For Use Cont. Adjustment: In order to achieve optimal settings for • economy and comfort, we recommend adjusting the operating temperature of the central heating water according to the outside temperature, positioning the knob as in fi gure 5.4 Your installer may have installed addi-• tional energy saving equipment and will be able to recommend the most suitable adjustment for your system. The temperature and pressure gauge (Fig. • 5.1 on page 11) will allow you to check that the set temperature is obtained. Figure 5.4 From 41 to 59°F Lower than 23°F Between 23 and 41°F Extinguishing Instructions:5.5 To turn

  • bsg Savio FP, 14 SAVIO FP USER MANUAL 5. Instructions For Use Cont. Domestic hot water temperature:5.6 The temperature of the domestic hot water coming out from the boiler can be regulated from a minimum of approximately 95° F to a maximum of approximately 131° F by turning the control shown in fi g. 5.6 Figure 5.6 Minimum Maximum Figure 5.7 Adjustment of the d.h.w. temperature is completely separate from that of the c.h. circuit. The adjustment system integrated within the boiler automatically controls the fl ow of gas to the burner in order to keep the temperat

  • bsg Savio FP, SAVIO FP USER MANUAL 15 Useful Advice6. Central Heating:6.1 For reasonably economical service install • a room thermostat. Never shut off the radiator in the area • where the room thermostat is installed. If a radiator (or a convector) does not heat • up, check that no air is present in it and that its valve is open. If the ambient temperature is too high, do • not alter the radiator valves. Reduce the central heating temperature instead by means of the room thermostat and the knob (C in Fig. 6.1). Figure 6.1 C Frost Protection:6.2 The built in antifreeze system and any additional system protect the boiler from possible • damages due to the

  • 16 SAVIO FP USER MANUAL 6. Useful Advice Cont. External Cleaning:6.4 Before performing any cleaning, disconnect the appliance from the electrical mains, using • the dedicated circuit breaker or serviceman’s switch located adjacent to the appliance. To clean the external panels, use a cloth soaked in soapy water. Do not use solvents, abra-• sive powders or sponges. Do not carry out clea

  • bsg Savio FP, SAVIO FP USER MANUAL 17 6. Useful Advice Cont. If water comes out of the pressure relief valve pipe 3 in Fig. 6.3: Check on the temperature and pressure • gauge (fi gure 5.1 on page 11) that the pressure in the central heating circuit is not close to 3 bars (43.5 psi). In this case, temperature rise in the circuit can cause the pressure relief valve to open. So that this does not happen and to de-• crease the pressure to a normal value, it is advisable to vent some of the water in the appliance through the bleed valves present in the heating system. Figure 6.3 If water should occa

  • bsg Savio FP, 18 SAVIO FP USER MANUAL Warranty For SAVIO Residential Wall Hung Gas Boilers FIRST 2 YEARS-WARRANTY FOR SAVIO SERIES RESIDENTIAL HOT WATER BOILERS: BOYERTOWN warrants that itswall hung boiler and casing are free from defects in material and workmanship for 2 years from the date of installation. If any part on the boiler is found to be defective within this period, BOYERTOWN will replace the part free of charge. FIRST 10 YEARS-WARRANTY FOR SAVIO SERIES RESIDENTIAL HOT WATER BOILERS: SAVIO war- rants that the copper tube heat exchanger of

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 VOGELS CFM 060 - VOGEL'S COMPSE CONSUMER SEPTEMBER 2007 Brochure vogels/cfm-060-vogel-s-compse-consumer-september-2007-P6B.pdf 23 Jun 2023 12 11.66 Mb
2 Q-See QCW3MP16 Quick start manual q-see/qcw3mp16-69P.pdf 09 Aug 2022 12
3 Vax Energise Vibe C85-E2-Be Let's get started vax/energise-vibe-c85-e2-be-YM9.pdf 29 Jun 2022 16
4 Lenovo A600e Operation & user’s manual lenovo/a600e-KIC.pdf 19 Dec 2022 59
5 BALAY 3KIB4850 User manual manual balay/3kib4850-MK5.pdf 18 Aug 2023 46 0.8 Mb
6 FremantleMedia 600 Operation & user’s manual fremantlemedia/600-7M9.pdf 19 Mar 2024 15 1.35 Mb

Similar Resources:

  • IBC Technologies

    SL 30-175

    (78 pages)
    INSTALLATION AND OPERATING INSTRUCTIONSwww.ibcboiler.comSL 30-175, SL 45-260 MODULATING GAS BOILERS (Natural Gas or Propane)WARNING: If the information in this manual is not followed exactly, a re or explosion may result causing property damage, personal injury, or loss of life.Do not store or use gasoline or other ammable vapours and liquids or other …
  • PEERLESS

    Combi 160

    (79 pages)
    BoilerPeerless®GasInstallation,Operation &MaintenanceManualCombi 160As an ENERGY STAR®Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency. …
  • Windhager

    FireWIN

    (52 pages)
    Assembly instructionsFireWIN windhager.comFully automatic pellet central heating boilerfor the living room and entire apartmentPerformance range: 4,7 to 12 kWPellets07/2012 092125/05 …
  • Slant/Fin

    VICTORY VSPH SERIES

    (36 pages)
    HOT WATER MODELS VHS-30 THROUGH VHS-180GAS-FIRED CAST-IRON BOILERS FOR NATURAL AND L.P. PROPANE GASESThe installation must conform to the requirements of theauthority having jurisdiction or, in the absence of suchrequirements, to the National Fuel Gas Code, ANSI Z223.1-latest edition. The installation must also conform to the addi-tional requirements in thi …
  • Viessmann

    Vitotronic 300 KW3

    (28 pages)
    VITOTRONIC 300Installation InstructionsVitotronic 300Model KW3Weather-responsive indoor/outdoor, digital boiler controlfor heating systems with one or more heating circuitsPart No. Z001 231Certified as a component partof Viessmann boilers only5303 269v1.3 10/2011 …
  • Delta

    35

    (20 pages)
    INSTALLATION OPERATING ANDSERVICING INSTRUCTIONSNOTICE D’INSTALLATION,D’UTILISATION ET D’ENTRETIENGEBRUIKSHANDLEIDING ENINSTALLATIEVOORSCHRIFTdeltaexcellence in hot waterENNLFRdeltaperformanceperformanceventouse FV15/06/2004 - 664Y1600 …

Comments, Questions and Opinions: