Bongioanni Multidea Evo, The appliance must be installed by qualified personnel in conformity with current Technical Standards and national and/or local legislation. All safety, installation and maintenance instructions must also be strictly observed, as stated in this manual. Dear Client, Thank you for purchasing this condensing appliance, a technically advanced and high quality product, offering high efficiency and extremely low pollutant emissions and therefore complete respect of the environment, designed to meet all your needs for comfort at low operating costs. Please read this manual with care before
INDEX SAFETY WARNINGS AND REGULATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 PROHIBITED ACTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . .
Bongioanni Multidea Evo, • After unpacking the appliance, ensure that all parts are intact and complete as per the supply specifications, and if any non-conformities are found, contact the Representative that sold the appliance. • The appliance must be installed by professionally qualified personnel, in conformity with current national and local standards and the instructions in the manual supplied with the product. • The appliance must only be used as envisaged in the design. The manufacturer declines all liability for physical injury or damage to animals or objects caused by errors in i
The aluminium boilers in the range Multidea Evo are condensing heat generators, designed to heat rooms, and in combination with a storage tank, for the production of domestic hot water. They comprise: - a steel heat exchanger, with low water content and generously sized exchange surface to optimise energy efficiency and heating output; - a full pre-mix microflame burner in stainless steel, to
Bongioanni Multidea Evo, CONTROL PANEL DSP eco esc menu ok Monday, 24. September 2012 09.37 Key Description offunction Display H ON/STAND-BY STAND-BY: This shuts down the appliance, inhibiting the use of DSP keys ON: This enables start-up of the appliance, enabling use of DSP keys date time date OUTSIDE 7 o C 69 o 0.0 OFF OFF time Key functions DESCRIPTION OF SYMBOLS ON DISPLAY Monday, 24. September 2012 OUTSIDE 5 o C 80 o 0.0 ON ON 09.37 HEATING D.H.W. SET DATE SUPPLY TEMPERATURE READING DOMESTIC HOT WATER REQUEST ACTIVE OUTSIDE SENSOR TEMPERATURE READING OPERATING M
Bongioanni Multidea Evo, Key Description offunction Display I OPERATING MODES SUMMER: DHW production only WINTER: heating only or heating and DHW NONE: no heating or DHW Anti-freeze or “Manual Test” function active Monday, 24. September 2012 OUTSIDE 7 o C 69 o 0.0 ON OFF 09.37 Monday, 24. September 2012 OUTSIDE 7 o C 69 o 0.0 OFF 09.37 ON Monday, 24. September 2012 OUTSIDE 7 o C 69 o 0.0 ON ON 09.37 date OUTSIDE 7 o C 69 o 0.0 OFF OFF time J ECO - Manual This reduces, by the set value, the temperature of domestic water supply and heating water (energy saving mode) Monday, 24. September 2012 OUTSIDE 7 o C 69 o 0.0 ECO ECO 09.37 eco E ESC Interrupts the current action and returns to the in
Bongioanni Multidea Evo, Key Description offunction Display G HOLIDAY This enables entry of the holiday dates (start/end) and values for the supply of domestic hot water and heating water during this period Holiday start 20 / 10 2012 oK to confirm Holiday end 2012 to confirm oK 30 / 10 B D UP Enables the user to scroll up through the lines on screen DOWN Enables the user to scroll down through the lines on screen Keep pressed to speed up the scrolling action. oK User menu 1. HEATING 2. DOMESTIC HOT WATER 3. HOLIDAY 4. MAINTENANCE 5. SETTINGS 6. DIAGNOSTICS to confirm oK User menu 1. HEATING 2. DOMESTIC HOT WATER 3. HOLIDAY 4. MAINTENANCE 5. SETTINGS 6. DIAGNOSTICS to confirm C O
Bongioanni Multidea Evo, The initial commissioning of the appliance must be performed by the Technical Services, after which the appliance can operate automatically. The system supervisor can turn the appliance on and off as follows: IGNITION AND SHUTDOWN INITIAL COMMISSIONING - Power up the boiler from the electrical mains by setting the main system switch (IG) to “ON”. - The display returns to the stand-by screen. - Press H to activate the keypad for the DSP. date time date OUTSIDE 7 o C 69 o 0.0 OFF OFF time Key Description offunction Display A RED (at bottom) Enables return to the selected line without saving/ storing the modified data. DHW setpoint 50 oK to confirm A A a DHW s
MENU NAVIGATION TREES AND PROCEDURES date time date OUTSIDE 7 o C 69 o 0.0 OFF OFF time MENU H A F A oK A oK A DB C C User menu 1. HEATING 2. DOMESTIC HOT WATER 3. HOLIDAY 4. MAINTENANCE 5. SETTINGS 6. DIAGNOSTICS to conrm User menu 1. HEATING 2. DOMESTIC HOT WATER 3. HOLIDAY 4. MAINTENANCE 5. SETTINGS 6. DIAGNOSTICS to conrm USER TECHNICIAN See NAVIGATION TREE STAND-B
Bongioanni Multidea Evo, USER MENU Keys Sub-menu Keys Lines Keys Factory settings Field 1. HEATING C 1. CH temperature/OTC set C 1. CH temperature C 75°C 20 - max. absolute T. (*) D B D 2. Outside temperature for CH off C OFF OFF / 7 - 30°C D 2. ECO setpoint reduction C ---> ---> 50°C 0 - 50°C D 3. Scheduler set C 1. Enable/disable scheduler C Enabled Enabled/ disabled D 2. Scheduler settings C Monday week days 2. DOMESTIC HOT WATER C 1. DHW setpoint C ---> ---> 80°C (**) 35 - 85°C D B D 2. ECO setpoint reduction C ---> ---> 20°C 0 - 50°C D 3. Scheduler set C 1. Enable/disable scheduler C Enabled Enabled/ disabled D 2. Scheduler settings C Monday week days 3. HOLIDAY C 1. CH ho
Bongioanni Multidea Evo, Key to the USER menu LINES Ref. menu line Line title Meaning 1. HEATING 1.1.1 CH temperature/OTC set Entry of setpoint of supply temperature (heating) 1.1.2 Outside temperature for CH off Entry of setpoint of outside temperature for automatic switchover to "Summer mode" 1.2 ECO setpoint reduction Entry of value to reduce temperature on supply in "energy saving" mode (day or night time) 1.3.1 Enable/disable on board scheduler Enable or Disable implementation of the "heating time bands" set for the various week days 1.3.2 Scheduler set Settings of the "heating time bands" applied for the various week days 2. DOMESTI
Bongioanni Multidea Evo, The system also envisages the option of setting time bands during which the boiler is set to operate, if there is a demand for heat, and those during which it remains off, or in ECO mode when fitted with an outside sensor. There is a maximum of 6 programmable time bands within 24 hours, each of which must be identified by a start time (ON), and end time (OFF). The minimum interval between each time is half an hour. SCHEDULER SETTINGS Key to press Description Display F A to display the MENU screens to enter the USER MENU date OUTSIDE 7 o C 69 o 0.0 OFF OFF time ME
Bongioanni Multidea Evo, Key to press Description Display B D C to select the single day or group of days in the week to confirm and access the selected line oK Scheduler set 5. Friday 6. Saturday 7. Sunday 8. Monday-Friday 9. Monday-Sunday 10.Saturday-Sunday to confirm oK 1. --:-- - --:-- -- 2. --:-- - --:-- -- 3. --:-- - --:-- -- 4. --:-- - --:-- -- 5. --:-- - --:-- -- 6. --:-- - --:-- -- Monday-Friday to confirm to select Save & Exit A OR A D D D to set the “start” time of the first band to set the “end” time of the first band to select the operating mode of the first time band, from ON, ECO or -- (boiler OFF) to go to the second time band To ente
TEMPORARY SHUTDOWN OR HOLIDAY SCHEDULE This function enables a reduction in the operating regime of the boiler in the case of temporary absences, weekends, holidays and above all automatic restart after the set time interval. b WARNINGS • During the holiday period, it is essential to leave the electrical and gas mains supplies to the appliance powered, to
Bongioanni Multidea Evo, Key to press Description Display E G to return to the initial screen to display the “Holiday start” date date OUTSIDE 7 o C 69 o 0.0 OFF OFF time Holiday start 20 / 10 2012 oK to confirm a a A A OR A D A OR A D A OR A C to set the holiday start day to select the month to set the month to select the year to set the year to confirm the settings made and enter the "Holiday end" screen. NOTE: to make the settings for the day, month and year of the holiday end, f
Bongioanni Multidea Evo, ROUTINE CLEANING Internal cleaning of the appliance and removal of combustion residue from the exchange surfaces are operations required at least once a year, to be performed by professionally qualified personnel. This is an essential condition to reduce consumption, pollutant emissions and to keep the stated efficiency and reliability of the boiler over time. Before cleaning: - Set the main system switch (IG) to “OFF” - Close the fuel shut-off valves. EXTERNAL CLEANING The outer casing should be cleaned with cloths dampened with water and detergent.
Bongioanni Multidea Evo, Professional Bongioanni Caldaie S.r.l. Offices - Services and Facilities: Via Piave, 14 12011 Borgo San Dalmazzo (CN) Tel. +39-0171-687816 - Fax +39-0171-857008 www.bongioannicaldaie.it - [email protected] For purposes of improvements, Bongioanni Caldaie reserves the right to make modifications to product characteristics at any time without notice. Bongioanni Caldaie declines all liability for any errors or inaccuracies in this catalogue, which may not be considered as a form of agreement with any third parties. 008274139 1015 20A4 IT
Vaillant ecoTEC plus SERIES Boiler Installation and maintenance instructions manual
ecoTEC plus SERIES |
Viessmann VITOCROSSAL 200 Boiler Service instructions manual
VITOCROSSAL 200 |
Viessmann Vitodens 100-W WB1B Series Boiler Service and maintenance manual
Vitodens 100-W WB1B Series |
Bongioanni Multidea Evo 60 Boiler Installation and maintenance instructions manual
Multidea Evo 60 |
Siemens DO05705 Boiler Installation & operating instruction
DO05705 |
Allied Engineering 6MSE Boiler Installation and service manual
6MSE |
Glow-worm Ultracom 24cxi Boiler User manual manual
Ultracom 24cxi |
Vulcan-Hart VSX24G Boiler Specifications
VSX24G |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Ematic | E4 series | Operation & user’s manual | ematic/e4-series-59N.pdf | 26 Dec 2022 | 40 | 2.96 Mb |
2 | TANDBERG | ENTRYPOINT | Administrator's manual | tandberg/entrypoint-8A7.pdf | 28 Dec 2023 | 53 | 7.58 Mb |
3 | ViewSonic | PJD6220 | Brochure & specs | viewsonic/pjd6220-5A2.pdf | 05 Aug 2022 | 2 | 1.05 Mb |
4 | Philips | 32PFL8404H | Operation & user’s manual | philips/32pfl8404h-D19.pdf | 18 Mar 2023 | 230 | 3.12 Mb |
5 | Yamaha | SY-35 | Owner's manual | yamaha/sy-35-6Q6.pdf | 06 Feb 2024 | 100 | 4.77 Mb |
6 | Hitachi | VT-FX623A | Owner's manual | hitachi/vt-fx623a-HVG.pdf | 07 Feb 2023 | 65 | 2.28 Mb |
Dettson
ELECTRIC BOILERELECTRONIC CONTROL2013-09-25 X40218 Rev. Cwww.dettson.caHYDRAR15-E2401MHYDRAR18-E2401MHYDRAR20-E2401MHYDRAR24-E2401MHYDRAR27-E2401MHYDRAR29-E2401MModels:Installation Instructions and Homeowner’s ManualDettson Industries IncManufactured by:3400, Industrial BoulevardSherbrooke, Qc, Canada, J1L 1V8AttentionDo not tamper with the unit or its co …
HYDRAR15-E2401M(20 pages) |
UTICA BOILERS
installation, operation and maintenance manUalAn ISO 9001-2000 Certied CompanyMEMBER: The Hydronics InstituteUB90 125-200 GAS-FIRED, DIRECT VENT, CONDENSING, HOT WATER BOIlERUTICA BOILERSP.O. Box 4729 Utica, NY 13504-4729 www.uticaboilers.com P/N 240004826U, Rev. A [10/08]
…
UB90125(44 pages) |
Bmax Technology
Bmax Technology - a Division of Elmec Group S.r.l. Localition Cà D’Oro 36020 - Asigliano Veneto (VICENZA) - ITALY TEL. +39 0444-772023 - FAX +39 0444-773129 E-mail: [email protected] - Web: www.b-max.com Elmec Group S.r.l. Tax Code and VAT no.: 03725780245 - THE PRESENT MANUAL FORMS AN INTEGRAL PART OF THE BOILER AND MUST BE KEPT FOR FUTURE REFERENCE Pel …
B-MAX 25(12 pages) |
Smith
19BAI-119HE SERIES BOILERBOILER SECTION ASSEMBLY INSTRUCTIONSWhen boilers are delivered to the job site, each itemshould be inspected closely for possible shipping damage. Scars or nicks in the port sealing surfacesmay allow leakage. Do not attempt to use any sectionthat has been damaged in the port seal area. Cleanhydronic gasket (port) recesses and rope g …
19HE series(2 pages) |
Immergas
Manual de instrucciones y advertenciasPodręcznik obsługi wraz z instrukcjamiTalimat ve uyarılar kitapçığı Návod k použití a upozornění Priročnik z navodili in o pozoriliHasználati utasítás és gyelmeztetésekРуководство по эксплуатацииManual de instrucţiuni şi recomandăriInstruction booklet and warningNá …
MINI NIKE 24 3 E(198 pages) |
sylber
Installer and user manualDEVYL 11 D ie FF - 13 D ie FF - 17 D ie FFENFRESPTGRITMANUALE INSTALLATORE E UTENTEINSTALLER AND USER MANUALMANUEL D’INSTALLATION ET D’UTILISATIONMANUAL DE INSTALACIÓN Y USOMANUAL PARA INSTALAÇÃO E USOΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΤΗ ΚΑΙ ΧΡΗΣΤΗ
…
DEVYL 11 D ie FF(92 pages) |
Lenovo Desktop PC 300PC 300 (Desktop ePDF User Guide, #Y6QK4Z) PC 300, 54 |
Lenovo Desktop ThinkStation E20#GX5U42: ThinkStation E20 Desktop Operation & user’s manual ThinkStation E20, 94 |
Multitech Chassis CC9648Multitech CC9648 User Manual (Operation & user’s manual), @164531 CC9648, 26 |
IEI Technology Motherboard KINO-PV-D4253-R10PDF User Manual (@1534K7), IEI Technology KINO-PV-D4253-R10 Motherboard (18.08.2023) KINO-PV-D4253-R10, 11 |
Skil Power Tool 74907490 Operating/safety instructions manual - GP2JS2 7490, 28 |
FlyTech Toy DragonflyToy #9MXCXF Dragonfly, 10 |
Pyle Car Receiver PLCD46Pyle PLCD46 Guide (Instruction manual), @88P87M PLCD46, 6 |
Panasonic Security Camera WV-Q167Panasonic WV-Q167 User Guide (Operating instructions), @J6S3X6 WV-Q167, 2 |
Norlake Refrigerator NSPR241WWGNorlake NSPR241WWG User Guide (Specifications), @44CB97 NSPR241WWG, 2 |
Black Box Switch ServSwitch EC 26614PDF User Manual (@OZC837), Black Box ServSwitch EC 26614 Switch (12/12/2023) ServSwitch EC 26614, 2 |
Edelbrock Automobile Parts 15022Automobile Parts Installation instructions (Edelbrock 15022) 15022, 2 |
LEGO Toy Starwars 75111Assembly manual for LEGO Starwars 75111 Toy Starwars 75111, 48 |