Manualios.com

Borri 1Kva Operation & User’s Manual

Borri 1Kva Manual Online:

3.15, 1659 votes
Borri 1Kva User Manual
Borri 1Kva User Guide
Borri 1Kva Online Manual

Text of Borri 1Kva User Guide:

  • Borri 1Kva, 2 Chapter 1. IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries. An Important Notice • To ensure safety in all applications where a UPS is hard wired to the Electrical Supply, ensure that the system is installed by a Qualified Electrical Contractor. • The UPS systems which are supplied with a factory input plug can be safely connected to the w

  • 4 Chapter 2. Product Introduction 2.1. General Characteristics • True online, Double Conversion architecture continuously supplies to your critical device with a stable, regulated, transient-free pure sine-wave AC Power. • 50KHz PWM sine-wave topology yields an excellent overall performance. • The high crest factor of the inverter handles all high-inrush current lo

  • Borri 1Kva, 6 Chapter 3. Introduction to the Front and Rear Panel 3.1. Front Display Panel Descriptions 7 1. Main Switch Button To Switch on/off the UPS 2. Self Test OK LED Green LED lights up if self test is satisfactory. 3. Test/Silence Button a. To silence the alarm buzzer. b.1. Applicable for Standard Unit To execute the self test of the UPS by pressing the button over 10 sec. b.2. Applicable for Unit with Manual Bypass function (Special order required) To press the button over 5 seconds, the UPS will be switched to Bypass mode and vice versa. c. To illustrate the percentage of output load level at AC Mode, and th

  • Borri 1Kva, 8 3.2. Rear Panel Descriptions 9 1) AC Inlet This is to be connected with an AC power cord for plugging into the wall receptacle. This is to disconnect line input to protect application from Output overload or short circuit. Fuse/Breaker Rating for 120Vac/230Vac systems 1Kva 2Kva 3Kva 2) AC Input Fuse/ Breaker 120Vac: 20A/250V 230Vac: 10A/250V 120Vac: 25A/250V 230Vac: 20A/250V 120Vac: 50A/250V 230Vac: 25A/250V 3) External Battery Terminal This is a battery terminal to be connected with additional battery banks for longer backup time applications. Only a

  • Borri 1Kva, 10 3.2.1. Terminal Layouts and Descriptions a) For 3Kva 120Vac b) For 3Kva 230Vac 11 3.3. Communication Port Descriptions The communication port on the rear panel of the UPS is a true RS232 serial type. It may be connected to a computer and allows the computer to monitor the status of UPS, and controls the operation of the UPS, via an additional UPS software kit. The bundled software of the UPS is for Windows environment, such as Windows 3.1, Windows 95, 98 & Windows NT. For other applications, such as Novell NetWare, Unix, etc., please contact your

  • 12 Chapter 4. Installation and Operation Note: The packing condition and the external outlook of the unit should be inspected carefully before installation. Retain the packing material for future use. 4.1. Unpacking 1. Take the UPS out of the PE foam. 2. Remove the packing materials. Note: The UPS module is approx. 12.5~39 kgs, be cautious when unpacking an

  • Borri 1Kva, 14 4.3. Installation Instructions 4.3.1. Tower installation Stand alone unit Step 1 Step 2 15 Use with extended battery bank Step 1 Step 2 www.upsdirect.com

  • Borri 1Kva, 16 4.3.2. Rack Mount installation Step 1 Step 2 Step 3 17 Step 4 Step 5 www.upsdirect.com

  • Borri 1Kva, 18 4.4. Operation Test All installation should be conducted or supervised by a qualified technician. Charge the UPS for more than 8 hours after unpacking to ensure the batteries of the UPS are fully charged before usage. 1. Make sure there is a proper grounding of the wall receptacle. 2. Verify if the voltage and frequency ratings match that of Utility, connect the AC Input power cord to a verified grounded 3-wire receptacle. 3. Push on the Main switch on the front panel to start the UPS, the ventilation fan should start ind

  • Borri 1Kva, 22 Chapter 5. UPS Working Principle 5.1. When Utility is Normal The working principle of the UPS under Utility normal condition is illustrated as follows, When Utility is normal, the AC source is rectified to DC, partially fed into the charger to charge battery and partially fed into inverter. The inverter reverts the DC to a cleaned and pure AC to supply energy to the load connected. The Utility LED and Inverter LED Light up. 5.2. When Utility is Abnormal The working principle of the UPS under Utility abnormal condition is illustrated as follows,

  • Borri 1Kva, 24 5.4. Inverter Failure 5.4.1. Output short circuit under inverter mode If output load is short circuited under inverter mode, the UPS will turn off the output to prevent damage to its Inverter and the connected load. The Fault LED lights up and the buzzer sound continuously. The UPS will not turn on automatically after short circuit condition is eliminated. You are required to re-start the UPS manually. To re-start the UPS after short circuit condition is removed, you should push the Main Switch on

  • Borri 1Kva, 26 Situation Check Items Solution Battery Low LED lights up Battery is running low. Please proceed to shutdown your load immediately. Recharge the battery. Fault LED lights up Disconnect the output load immediately. Switch Off and On the UPS to see if the "Fault" LED is still on. If not, your output load has probably been shorted. Otherwise, call for service. System fails to backup when Utility fails. Check UPS to Battery connection (for extended battery configuration). Check the Battery Terminal voltage if is within its rating (12V) Switch Off the UPS. Disconnect t

  • Borri 1Kva, 28 C. RUPS II for Novell Netware (Optional) 1. Login the File Server as a SUPERVISOR or a USER with Access Right in sub-directory SYS:SYSTEM. F:\>LOGIN SUPERVISOR 2. Insert the system diskette into the floppy disk Driver A (or your PC designated drive). 3. Execute INSTALL.EXE in Driver A. F:\>A: A:\>INSTALL 4. After the installation is complete, please shutdown your NetWare Operating System and re-start it. The system will load the PowerMan.NLM and execute it. 5. When the RUPS II for NetWare Is loaded, the Filer Server will broadcast a successful load

  • Borri 1Kva, 30 Chapter 8. Appendix 8.1. Specifications MODEL 1Kva 2Kva 3Kva INPUT Voltage (Vac) 80~140 or 160~280 Frequency (Hz) 50 / 60±5%(Auto Sensing) Phase Single Input Power Factor > 0.98(Full Load) OUTPUT Voltage (Vac) 100/110/115/120 or 200/220/230/240 DIP Switch Selectable Capacity(VA/W) 1000/700 3000/2100 3000/2100 Wave Form Sine Wave, THD<3%(no load to full load) Voltage Regulation ±2% Frequency Stability ±0.5Hz (Free Running) Transient Response(ms) +/-4% Under full load step and corrected within 60ms Synchronization 1 Hz/S

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Hunter 30374 Operation & user’s manual hunter/30374-593.pdf 03 Sep 2023 8
2 Magnavox MDV2300 Owner's manual magnavox/mdv2300-597.pdf 15 Sep 2022 19
3 Chase-durer Conquest Chronograph Operation manual chase-durer/conquest-chronograph-E32.pdf 23 Jul 2023 11 1.5 Mb
4 Oki B6300 Series Safety and warranty manual oki/b6300-series-9X8.pdf 21 Dec 2023 36
5 Dyson DC54 Operating manual dyson/dc54-8S1.pdf 20 Jul 2022 12 1.26 Mb
6 Jabra GN2100 Datasheet jabra/gn2100-5F5.pdf 17 Jan 2023 2

Similar Resources:

  • Xtreme Power Conversion

    700VA

    (37 pages)
    T90 Online UPS700VA, 1000VA, 1500VA, 2000VA, 3000VA ModelsUser & Installaon Manualwww.xpcc.com | © 2014 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 9/15/14) …
  • GE

    Uninterruptible Power Supply

    (10 pages)
    GE USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 – 600 – 800 – 1000 – 1500 VA GE Consumer & Industrial SA General Electric Company CH – 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com g imagination at work …
  • Tripp Lite

    BP192V557C-16K

    (2 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: BP192V557C-16K External battery pack for use with select Tripp Lite UPS SystemsHighlightsExtends runtime of compatible Tripp Lite UPS Systems using 192VDC configurationIncludes built in 7A chargerIncludes UPS connection cablingHardwire insta …
  • CyberPower

    CPS1000EI

    (8 pages)
    EN CPS1000EI/CPS2000EI User’s Manual K01-C000028-02 IMPORTANT SAFETY INFORMATION (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate …
  • Bay Networks

    UPS45

    (9 pages)
    990-7065 Revision 1, 7/98BayStack UPS45Uninterruptible Power SupplyUser’s ManualEnglish202526-AInstallationTo obtain warranty coverage, please fill out andreturn the warranty registration card now.InspectionInspect the BayStack UPS45 Uninterruptible PowerSupply (UPS) upon receipt. Notify the carrier anddealer if there is damage. The packaging isrecyclable; …
  • Liebert

    Series 600

    (113 pages)
     …

Comments, Questions and Opinions: