  • Bacchus BCS1000, 1 Installation Manual BCS 1000/1500 Supplies Needed for Installation 1. Double insulated refrigerant line set. 2. 1/4” copper water supply 3. 1/4” condensate vinyl drain tube/tube clamps 4. Provide 120V 15A circuit for indoor evaporator, and 120V/230V 30A, single or three phase (dependent upon your condensing unit) for outdoor condensing unit. Check local codes. 5. 18-2 stat wire; to be used to extend temperature sensor, humidity sensor cable, keyboard. 6. Condensing unit pad Condensing Unit Set Up 1. Place a (suggested model) on a firm level location (pad) for outdoor a

  • 2 3. Run the recommended double insulated line set from the condensing unit to the evaporator opening (50 foot max.). 4. Power from disconnect (recommended) 12-2/with ground to the condensing unit. 5. Check low pressure control for the correct 25 psi setting, with a 15 psi differential. Diagram 1 Evaporator Set Up

  • 3 EVAPORATOR SET UP, continued 6. Wrap the TXV and refrigeration solenoid with ESP Heat block (#HB34) or comparable product. Braze the refrigerant solenoid to the liquid line. Remove the TXV bulk and braze in the suction line to the line exiting the condenser. Re-attach the bulb when cool. 7. Locate the nearest water supply. Shut off water suppl

  • Bacchus BCS1000, 4 Controller Display Set Up 1. Install double gang box and cut out the blank plate to accept the Bacchus Temp/Humidity Keyboard (VH620). The keyboard can be mounted inside or outside of the room. Run 18-2 stat wire from the monitor back to the evaporator above the ceiling opening, and attach to the yellow and green lead wires indicated. The keyboard can be mounted up to 75 feet from the microprocessor inside the evaporator. 2. Mount the humidit

  • Bacchus BCS1000, 5 11. Alarm Signaling Message Cause Outputs “P1” Thermostat probe failure compressor and heating outputs off (on dehumidification system only) “P3” Humidity probe failure humidity regulation off “HA” High temp alarm outputs unchanged “LA” Low temperature alarm outputs unchanged “HHA” High humidity alarm outputs unchanged “HLA” Low humidity alarm outputs unchanged In the instance of any of these alarms, call Bacchus Tech Services, or your installation contractor. Power to the Evaporator 1. Bring

  • Bacchus BCS1000, 6 Charging the System 1. Evacuate and pressure test the system. This can be accomplished by charging with nitrogen to 75 lbs and checking your gauges for any sign of a leak. Evacuate the system to 500 microns. 2. Charge the system with R134A until the sight glass goes clear. It is very important not to over- charge this system. As soon as the bubbles in the sight glass disappear, discontinue charging. Over- charge will result in an ice block in the evaporator. 3. Adjust the TXV to 12-14 degrees of superh

  • Bacchus BCS1000, 7 Troubleshooting Alarm conditions on the electronic controller, Call BCS Tech Services at 937-665-0424 Unit will not reach temperature Call your installation contractor to Determine proper refrigerant charge. Dirty condenser? Unit has shut off Call BSC tech services or field Service; could be bad Compressor, fans, controller or Pump Alarm Signaling Message Cause Outputs “P1” Thermostat probe failure compressor and heating outputs off (on dehumidification system only) “P3” Humidity probe failure humidity regulation off “HA” High temp

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG LG357 Brochure lg/lg357-JYL.pdf 28 Feb 2024 2
2 Socket Wireless LAN CF Card 11Mbps Operation & user’s manual socket/wireless-lan-cf-card-11mbps-ZBO.pdf 10 Nov 2022 53 1.88 Mb
3 HP D5970A - NetServer - LCII Configuration manual hp/d5970a-netserver-lcii-ZYR.pdf 07 Aug 2023 82 0.71 Mb
4 Husqvarna 122LDx Operator's manual husqvarna/122ldx-318.pdf 10 Jun 2023 76
5 Philips DLA66001D Brochure philips/dla66001d-K7B.pdf 30 Dec 2022 2
6 Universal Remote Control MX-350 Owner's manual universal-remote-control/mx-350-H17.pdf 09 Jul 2023 33 2.38 Mb

Similar Resources:

  • Toshiba

    RAV-SM562BT-E

    (194 pages)
    R410AFILE NO. A05-018Revised: Jul/25/2005PRINTED IN JAPAN, Jan.,2006 ToMoSERVICE MANUAL/INTEGRATIONSPLIT TYPEINDOOR UNIT<DIGITAL INVERTER>RAV-SM562UT-E RAV-SM562BT-E RAV-SM562CT-ERAV-SM802UT-E RAV-SM802BT-E RAV-SM802CT-ERAV-SM1102UT-E RAV-SM1102BT-E RAV-SM1102CT-ERAV-SM1402UT-E RAV-SM1402BT-E RAV-SM1402CT-E<SUPER DIGITAL INVERTER>RAV-SP1102UT-E …
  • Carrier

    GAS FURNACE 58MVP

    (46 pages)
    58MVPVariable-Speed 2-StageElectronic Condensing FurnaceTroubleshooting GuideINDEXPAGEInstructions .....................................................................................1Example..........................................................................................1Sequence of Operation........................................................ …
  • Kenmore

    580.73083

    (40 pages)
    Owner's ManualManual del Propietario®THROUGH-THE-WALLAIR CONDITIONERACONDICIONADODEAIREA TRAVESDE PAREDModel, Modelo 580.73083 580.74103 580.74123Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.www.sears.com …
  • EWC Controls

    ULTRAZONE MRK

    (4 pages)
    EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-635-8646 E-Mail- [email protected]:(1) MA-ND3 Motor Actuator(1) ND/ND2 Anti-Rotation Bracket(1) URD/RDN (1) Shaft Adaptor(4) 11/32 hex nuts(2) #8 x 1/2” self tap screws(2) Flat washers(4) #6 phillips screwsTools Required:1/4” Nut Driver5/16” Nut Driver1 …
  • Danby

    DAC145EB6WDB-6

    (76 pages)
    DANBY PRODUCTS LIMITED, ONTARIO, CANADA N1H 6Z9DANBY PRODUCTS INC., FINDLAY, OHIO, USA 45840OWNER’S MANUALMANUEL DU PROPRIÉTAIREMANUAL DEL PROPIETARIOwww.Danby.com**2021.03.08MODEL • MODÈLE • MODELODAC145EB6WDB-6AIR CONDITIONEROwner’s Manual.............................1 - 24CLIMATISEURManual du propriétaire............. …
  • GE

    ASF24

    (40 pages)
    Safety Instructions . . . . . . . . . .2, 3Operating InstructionsControls—Control Knobs . . . . .6, 7Controls—Touch Pads . . . . . . .4, 5Care and CleaningAir Filter . . . . . . . . . . . . . . . . . . . . .8Batteries . . . . . . . . . . . . . . . . . . . . .8Grille and Case . . . . . . . . . . . . . . .8Outdoor Coils . . . . . . . . . . . . . . . …

Comments, Questions and Opinions: